Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Test Pilots”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Real-Time Stability and Control Derivative Extraction From F-15 Flight Data

A real-time, frequency-domain, equation-error parameter identification (PID) technique was used to estimate stability and control derivatives from flight data. This technique is being studied to support adaptive control system concepts currently being developed by NASA (National Aeronautics and Space Administration), academia, and industry. This report describes the basic real-time algorithm used for this study and implementation issues for onboard usage as part of an indirect-adaptive control system. A confidence measures system for automated evaluation of PID results is discussed. Results calculated using flight data from a modified F-15 aircraft are presented. Test maneuvers included pilot input doublets and automated inputs at several flight conditions. Estimated derivatives are compared to aerodynamic model predictions. Data indicate that the real-time PID used for this study performs well enough to be used for onboard parameter estimation. For suitable test inputs, the parameter estimates converged rapidly to sufficient levels of accuracy. The devised confidence measures used were moderately successful.

Smith, Mark S.↗

Control research in the NASA high-alpha technology program

NASA is conducting a focused technology program, known as the High-Angle-of-Attack Technology Program, to accelerate the development of flight-validated technology applicable to the design of fighters with superior stall and post-stall characteristics and agility. A carefully integrated effort is underway combining wind tunnel testing, analytical predictions, piloted simulation, and full-scale flight research. A modified F-18 aircraft has been extensively instrumented for use as the NASA High-Angle-of-Attack Research Vehicle used for flight verification of new methods and concepts. This program stresses the importance of providing improved aircraft control capabilities both by powered control (such as thrust-vectoring) and by innovative aerodynamic control concepts. The program is accomplishing extensive coordinated ground and flight testing to assess and improve available experimental and analytical methods and to develop new concepts for enhanced aerodynamics and for effective control, guidance, and cockpit displays essential for effective pilot utilization of the increased agility provided.

Gilbert, William P.↗

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Flight test maneuver modeling and control

The use of automated flight test schemes decrease the aircraft flight testing time and pilot work load while enhancing the data quality. Two major elements involved in developing such an automated technique are maneuver modeling to generate command histories from the maneuver specifications and the synthesis of control systems to track these command histories. This paper describes the maneuver modeling for eight flight test trajectories. The control system synthesis with Kosut's suboptimal minimum error excitation linear quadratic regulator approach is presented. The closed-loop simulation results are given.

Menon, P. K. A.↗

Spatial displays as a means to increase pilot situational awareness

Experiences raise a number of concerns for future spatial-display developers. While the promise of spatial displays is great, the cost of their development will be correspondingly large. The knowledge and skills which must be coordinated to ensure successful results is unprecedent. From the viewpoint of the designer, basic knowledge of how human beings perceive and process complex displays appears fragmented and largely unquantified. Methodologies for display development require prototyping and testing with subject pilots for even small changes. Useful characterizations of the range of differences between individual users is nonexistent or at best poorly understood. The nature, significance, and frequency of interpretation errors associated with complex integrated displays is unexplored and undocumented territory. Graphic displays have intuitive appeal and can achieve face validity much more readily than earlier symbolic displays. The risk of misleading the pilot is correspondingly greater. Thus while some in the research community are developing the tools and techniques necessary for effective spatial-display development, potential users must be educated about the issues so that informed choices can be made. The scope of the task facing all is great. The task is challenging and the potential for meaningful contributions at all levels is high indeed.

Fadden, Delmar M.↗

Inflight evaluation of four measures of pilot workload

Four measures of pilot workload were tested in the NASA C-141 Kuiper Airborne Observatory. The measured included a communications analysis, subjective ratings of workload, subjective ratings of additional factors related to workload, and heart rate. Data were collected for 11 flights, each of which lasted approximately seven hours. Heart rate was found to be significantly higher for the pilot who was flying than for the pilot who was not flying and it varied significantly across flight segments, peaking during landing and take off, particularly for the pilot in the left seat who was resonsible for aircraft control. For both left and right seats, the subjective assessment of stress rather than the subjective assessment of workload was significantly correlated with variation in heart rate. Frequencies of different types of communications varied significantly across segments of flight, however, they were not correlated with subjective ratings of workload. There was a significant difference between the left and right seats in the types of activities that contributed to their workload, however, workload was considered to be equivalent for the two.

Hart, S. G.↗

DuraMelter 100 Sub-Envelope Changeover Testing Using LAW SubEnvelopes A1 and C1 Feeds in Support of the LAW Pilot Melter (Final Report)

The primary goal of the testing described in this report was to develop and recommend a compliant HLW glass formulation to support the actual waste testing of AZ-101 Envelope D waste (blended with actual pretreatment products including Cs- and Tc-eluates from pretreatment of AP-101 and AZ-101 LAW). Testing of actual waste will be performed at Battelle, Pacific Northwest Division. The test objective was met by the development and recommendation of the glass formulation HLW98-95; the formulation has been transmitted to the WTP to support vitrification of HLW AZ-101 actual waste.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Ignition Delay of Combustible Materials in Normoxic Equivalent Environments

Material flammability is an important factor in determining the pressure and composition (fraction of oxygen and nitrogen) of the atmosphere in the habitable volume of exploration vehicles and habitats. The method chosen in this work to quantify the flammability of a material is by its ease of ignition. The ignition delay time was defined as the time it takes a combustible material to ignite after it has been exposed to an external heat flux. Previous work in the Forced Ignition and Spread Test (FIST) apparatus has shown that the ignition delay in the currently proposed space exploration atmosphere (approximately 58.6 kPa and32% oxygen concentration) is reduced by 27% compared to the standard atmosphere used in the Space Shuttle and Space Station. In order to determine whether there is a safer environment in terms of material flammability, a series of piloted ignition delay tests using polymethylmethacrylate (PMMA) was conducted in the FIST apparatus to extend the work over a range of possible exploration atmospheres. The exploration atmospheres considered were the normoxic equivalents, i.e. reduced pressure conditions with a constant partial pressure of oxygen. The ignition delay time was seen to decrease as the pressure was reduced along the normoxic curve. The minimum ignition delay observed in the normoxic equivalent environments was nearly 30% lower than in standard atmospheric conditions. The ignition delay in the proposed exploration atmosphere is only slightly larger than this minimum. Interms of material flammability, normoxic environments with a higher pressure relative to the proposed pressure would be desired.

Ignition delay time↗

How a pilot looks at altitude

Commerical pilot eye scanning data previously collected were reanalyzed to evaluate how pilot used the drum pointer altimeter. The results of these tests showed that the pilots seldom used the drum window apparently because it was difficult to read as indicated by average drum window dwell times of .6 seconds. It is suggested that pilot scanning data be collected for other type of altimeters in order to find those with good scanning characteristics.

Spady, A. A., Jr.↗

How a pilot looks at altitude

Commercial pilot eye scanning data previously collected were reanalyzed to evaluate how pilots used the drum pointer altimeter. The results of these tests showed that the pilots seldom used the drum window apparently because it was difficult to read as indicated by average drum window dwell times of 0.6 sec. It is suggested that pilot scanning data be collected for other types of altimeters in order to find those with good scanning characteristics.

Spady, A. A., Jr.↗

Manual flying of curved precision approaches to landing with electromechanical instrumentation. A piloted simulation study

A piloted simulation study was conducted to examine the requirements for using electromechanical flight instrumentation to provide situation information and flight guidance for manually controlled flight along curved precision approach paths to a landing. Six pilots were used as test subjects. The data from these tests indicated that flight director guidance is required for the manually controlled flight of a jet transport airplane on curved approach paths. Acceptable path tracking performance was attained with each of the three situation information algorithms tested. Approach paths with both multiple sequential turns and short final path segments were evaluated. Pilot comments indicated that all the approach paths tested could be used in normal airline operations.

Knox, Charles E.↗

Initial Evaluations of LoC Prediction Algorithms Using the NASA Vertical Motion Simulator

Flying near the edge of the safe operating envelope is an inherently unsafe proposition. Edge of the envelope here implies that small changes or disturbances in system state or system dynamics can take the system out of the safe envelope in a short time and could result in loss-of-control events. This study evaluated approaches to predicting loss-of-control safety margins as the aircraft gets closer to the edge of the safe operating envelope. The goal of the approach is to provide the pilot aural, visual, and tactile cues focused on maintaining the pilot's control action within predicted loss-of-control boundaries. Our predictive architecture combines quantitative loss-of-control boundaries, an adaptive prediction method to estimate in real-time Markov model parameters and associated stability margins, and a real-time data-based predictive control margins estimation algorithm. The combined architecture is applied to a nonlinear transport class aircraft. Evaluations of various feedback cues using both test and commercial pilots in the NASA Ames Vertical Motion-base Simulator (VMS) were conducted in the summer of 2013. The paper presents results of this evaluation focused on effectiveness of these approaches and the cues in preventing the pilots from entering a loss-of-control event.

Pilot Cue↗

Anthropogenic Markers in Alta Irrigation District Water Supply Wells

In July 2016, LLNL produced a report for the Kings River Watershed Coalition Authority (KRWCA) entitled “Groundwater Age and Nitrate Isotopic Composition in Alta Irrigation District Water Supply Wells” (Esser et al., 2016). That report summarized groundwater age and nitrate isotopic composition data produced by LLNL for Alta Irrigation District (AID) groundwater wells sampled by KRWCA in a pilot project to test the utility of advanced isotopic methods for constraining the timing and source of nitrate in groundwater at selected sites in the Kings River service area. One section of that report made recommendations for follow-on study. The first and strongest recommendation was to measure a wider suite of source tracers including co-contaminants such as herbicides, pesticides, pharmaceuticals, personal care products, and food constituents and additives. KRWCA followed up on this recommendation in Phase II of the pilot study by re-sampling the original set of wells and submitting the samples to a commercial laboratory for analysis of a limited range of co-contaminants (including pharmaceuticals, personal care products , and food constituents and additives, but not including herbicides or pesticides). They have asked that LLNL review and interpret these data in the context of previous LLNL analyses and to evaluate the utility of such co-contaminant analyses in providing additional constraints on the source of groundwater nitrate contamination in Alta Irrigation District water supply wells. The goal of the second phase of this pilot project is to evaluate the utility of co-contaminant occurrence for constraining nitrate source in groundwater at selected sites in the Kings River service area, with special reference to the use of such data in conjunction with advanced isotopic methods such as nitrate isotopic composition and groundwater age. Nitrate isotopic composition alone cannot distinguish nitrate derived from animal manure from nitrate derived from human septic waste. The presence or absence of agricultural chemicals (herbicides, pesticides, veterinary pharmaceuticals) or chemicals associated with people (human pharmaceuticals, artificial sweeteners) can help make this distinction. Co-contaminant analyses using multi-analyte LC-MS-MS protocols are now commercially available and reasonably priced. The feasibility and utility of the using co-contaminants for nitrate source attribution can be evaluated by 1) determining the degree to which co-contaminants occur in distinct and easily attributable groupings (e.g. agricultural chemicals vs personal care products and food additives); 2) determining the degree to which co-contaminant occurrence is consistent with nitrate isotopic composition and groundwater age (e.g. no co-contaminant occurrence in very old groundwater; co-contaminants consistent with animal manure or human septic waste occurring in groundwaters having nitrate isotopic composition also consistent with animal manure or human septic waste); and 3) determining the degree to which co-contaminants provide additional constraint on nitrate source over and beyond nitrate isotopic composition and groundwater age (e.g. distinguishing between animal manure and human septic waste).

58 GEOSCIENCES↗

Terrain Portrayal for Head-Down Displays Experiment

The General Aviation Element of the Aviation Safety Program's Synthetic Vision Systems (SVS) Project is developing technology to eliminate low visibility induced General Aviation (GA) accidents. SVS displays present computer generated 3-dimensional imagery of the surrounding terrain on the Primary Flight Display (PFD) to greatly enhance pilot's situation awareness (SA), reducing or eliminating Controlled Flight into Terrain, as well as Low-Visibility Loss of Control accidents. SVS-conducted research is facilitating development of display concepts that provide the pilot with an unobstructed view of the outside terrain, regardless of weather conditions and time of day. A critical component of SVS displays is the appropriate presentation of terrain to the pilot. An experimental study has been conducted at NASA Langley Research Center (LaRC) to explore and quantify the relationship between the realism of the terrain presentation and resulting enhancements of pilot SA and pilot performance. Composed of complementary simulation and flight test efforts, Terrain Portrayal for Head-Down Displays (TP-HDD) experiments will help researchers evaluate critical terrain portrayal concepts. The experimental effort is to provide data to enable design trades that optimize SVS applications, as well as develop requirements and recommendations to facilitate the certification process. This paper focuses on the experimental set-up and preliminary qualitative results of the TP-HDD simulation experiment. In this experiment a fixed based flight simulator was equipped with various types of Head Down flight displays, ranging from conventional round dials (typical of most GA aircraft) to glass cockpit style PFD's. The variations of the PFD included an assortment of texturing and Digital Elevation Model (DEM) resolution combinations. A test matrix of 10 terrain display configurations (in addition to the baseline displays) were evaluated by 27 pilots of various backgrounds and experience levels. Qualitative (questionnaires) and quantitative (pilot performance and physiological) data were collected during the experimental runs. Preliminary results indicate that all of the evaluation pilots favored SVS displays over standard gauges, in terms of terrain awareness, SA, and perceived pilot performance. Among the terrain portrayal concepts tested, most pilots preferred the higher-resolution DEM. In addition, with minimal training, low-hour VFR evaluation pilots were able to negotiate a precision approach using SVS displays with a tunnel in the sky guidance concept.

Hughes, Monica F.↗

History Matching and Performance Prediction of a Polymer Flood Pilot in Heavy Oil Reservoir on Alaska North Slope

The first-ever polymer flood pilot to enhance heavy oil recovery on Alaska North Slope (ANS) is ongoing. After more than 2.5 years of polymer injection, significant benefit has been observed from the decrease in water cut from 65% to less than 15% in the project producers. The primary objective of this study is to develop a robust history-matched reservoir simulation model capable of predicting future polymer flood performance. In this work, the reservoir simulation model has been developed based on the geological model and available reservoir and fluid data. In particular, four high transmissibility strips were introduced to connect the injector-producer well pairs, simulating short-circuiting flow behavior that can be explained by viscous fingering and reproducing the water cut history. The strip transmissibilities were manually tuned to improve the history matching results during the waterflooding and polymer flooding periods, respectively. It has been found that higher strip transmissibilities match the sharp water cut increase very well in the waterflooding period. Then the strip transmissibilities need to be reduced with time to match the significant water cut reduction. The viscous fingering effect in the reservoir during waterflooding and the restoration of injection conformance during polymer flooding have been effectively represented. Based on the validated simulation model, numerical simulation tests have been conducted to investigate the oil recovery performance under different development strategies, with consideration for sensitivity to polymer parameter uncertainties. The oil recovery factor with polymer flooding can reach about 39% in 30 years, twice as much as forecasted with continued waterflooding. Besides, the updated reservoir model has been successfully employed to forecast polymer utilization, a valuable parameter to evaluate the pilot test’s economic efficiency. All the investigated development strategies indicate polymer utilization lower than 3.5 lbs/bbl in 30 years, which is economically attractive.

Wang, Xindan↗

UAS Pilot Performance Comparisons with Different Low Size, Weight and Power Sensor Ranges

The present study evaluated the performance of UAS pilots under four simulated low size, weight, and power (SwaP) sensor ranges: 1.5nmi, 2.0nmi, 2.5nmi, and 3.0nmi. Nine active-duty UAS pilots responded to scripted DAA conflicts against non-cooperative intruders while flying a simulated RQ-7 Shadow at varied speeds along a pre-filed flight path in Class E airspace. Findings revealed a linear effect of sensor range on alerting time and separation performance, with nearly every DAA well clear (DWC) violation and all Near Mid-Air Collision (NMAC) events occurring below 2.5nmi. Response time differences at these reduced ranges were negligible due to the high frequency of warning-level alerts that require an immediate response. Since caution alert duration was truncated to some degree by each tested declaration range, pilots were often unable to coordinate their avoidance maneuvers with ATC prior to their uploads. Nonetheless, the 2.5nmi range allowed minimum alerting times that were sufficient for acceptable pilot performance. The study findings will inform DAA system requirements for UAS with alternative surveillance equipment and aircraft performance capabilities. Implications on DAA display and sensor requirements are discussed.

unmanned aircraft systems↗

UAS Pilot Performance Comparisons with Different Low Size, Weight and Power Sensor Ranges

The present study evaluated the performance of UAS pilots under four simulated low size, weight, and power (SwaP) sensor ranges: 1.5nmi, 2.0nmi, 2.5nmi, and 3.0nmi. Nine active-duty UAS pilots responded to scripted DAA conflicts against non-cooperative intruders while flying a simulated RQ-7 Shadow at varied speeds along a pre-filed flight path in Class E airspace. Findings revealed a linear effect of sensor range on alerting time and separation performance, with nearly every DAA well clear (DWC) violation and all Near Mid-Air Collision (NMAC) events occurring below 2.5nmi. Response time differences at these reduced ranges were negligible due to the high frequency of warning-level alerts that require an immediate response. Since caution alert duration was truncated to some degree by each tested declaration range, pilots were often unable to coordinate their avoidance maneuvers with ATC prior to their uploads. Nonetheless, the 2.5nmi range allowed minimum alerting times that were sufficient for acceptable pilot performance. These findings will inform DAA system requirements for UAS with alternative surveillance equipment and aircraft performance capabilities. Implications on DAA display and sensor requirements are discussed.

unmanned aircraft systems↗