Research and development study on thermal control by use of fusible materials Final report, Mar. 1964 - Mar. 1966
Packaging techniques and systems design for applying solid-to-liquid phase change concept to spacecraft temperature control subsystems
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Packaging techniques and systems design for applying solid-to-liquid phase change concept to spacecraft temperature control subsystems
Cool-flame-supported quasi-steady droplet combustion was first observed during droplet combustion experiments conducted onboard the International Space Station (ISS) in the Combustion Integrated Rack (CIR) with n-alkane fuels. These cool flames, not visible to the naked eye, result from the existence of the negative-temperature-coefficient (NTC) region during the combustion n-alkane fuels when the chemical-kinetic pathways experience a transition from the low-temperature chemistry to the normal, high-temperature-controlled chemistry. In this study, we present results for the cool-flame-supported droplet burning rates and extinction diameters for n-alkane fuels (n-heptane, n-octane, n-decane, and n-dodecane) in inert-diluent-substituted ambient environments. In these ISS experiments, some of the nitrogen in the ambient gas mixture is replaced by an inert gas, namely, carbon dioxide, helium, or xenon. Different diluents were observed to exert remarkably different influences on the cool-flame combustion of fuel droplets. The results show that the cool-flame extinction diameter is drastically increased with helium dilution compared to N2, CO2 or Xe, and Xe dilution leads to longer burning with a smaller extinction diameter. Unlike hot flames, the cool-flame burning rates are controlled by the cool-flame temperature established in the NTC region by the chemical kinetics, rather than by equilibrium thermodynamics, and the thermo-physical properties of the ambient gases, which control the heat feed back to the liquid droplet. The cool-flame extinction is triggered by the instability that occurs at the low-temperature end of the NTC region, below which cool diffusion flames become statically unstable. A quasi-steady theoretical model, presented earlier, which involves a six-step reduced-chemistry mechanism, valid around the lower end of the NTC region, is shown to explain the observed experimental trends qualitatively.
Mercury pressure suit and space suit design for project gemini, noting temperature control by ventilation distribution system
Automatic temperature control for liquid cooling garments used during astronaut extravehicular activity with external auditory meatus, and skin temperature as input signals
In this work, a novel temperature-reactivity controller is introduced to rotate control drums based on a chamber temperature signal. It consists of two components: (1) a reactivity-driven proportional controller converting the temperature demand into a reactivity signal, and (2) a temperature-driven proportional-derivative controller which relies on a derivative term to anticipate sudden changes in demand and limit temperature overshoot. A weighting function is proposed to continuously transition from one component to the other.
In this work, a novel temperature-reactivity controller is introduced to rotate control drums based on a chamber temperature signal. It consists of two components: (1) a reactivity-driven proportional controller converting the temperature demand into a reactivity signal, and (2) a temperature-driven proportional-derivative controller which relies on a derivative term to anticipate sudden changes in demand and limit temperature overshoot. A weighting function is proposed to continuously transition from one component to the other.
High temperature control surface seals have been identified as a critical technology in the development of future space vehicles. These seals must withstand temperatures of up to 2600 F and protect underlying temperature-sensitive structures (such as actuators and sealing capability by remaining resilient during flight conditions. The current baseline seal, used on the Shuttle orbiters and the X-38 vehicle, consists of a Nextel 312 sheath, an internal Inconel X-750 knitted spring tube, and hand-stuffed Saffil batting. Unfortunately at high temperatures (> 1500 F), the seal resiliency significantly degrades due to yielding and creep of the spring tube element. The permanent set in the seals can result in flow passing over the seals and subsequent damage to temperature sensitive components downstream of the seals. Another shortcoming of the baseline seal is that instances have been reported on Shuttle flights where some of the hand-stuffed Saffil batting insulation has been extracted, thus potentially compromising the seal. In vehicles where the thermal protection systems are delicate (such as with Shuttle tiles), the control surface seals must also limit the amount of force applied to the opposing surfaces. Additionally, in many applications the seals are subjected to scrubbing as control surfaces are actuated. The seals must be able to withstand any damage resulting from this high temperature scrubbing and retain their heat/flow blocking abilities.
Design changes in the thermoelectrically-cooled quartz microbalance, which is used to monitor surface contamination in space simulation chambers, is described in terms of its extended temperature range, increased temperature control, mass sensitivity, and cooling power. The mass sensor uses 20 MHz quartz crystals having a sensitivity of 8.8 x 10 to the minus tenth power g/sq cm - Hz. The crystals are optically polished, metal plated, and overplated with magnesium fluoride to simulate an optical surface. The microbalance temperature circuitry is designed to readout and control surface temperature between 100 C and minus 59 C to plus or minus 0.5 C, and readout only temperature between minus 60 C and minus 199 C using auxiliary liquid nitrogen cooling. Data is included on the measurement of oil contamination of surfaces as a function of temperature in space simulation chambers.
The control of mold surface temperature is an important factor that determines surface morphology and its dimension in thickness direction. It can also affect the frozen molecular orientation and the mold surface replicability in injection molded products. In this work, thin thermally active films were used to quickly control the mold surface temperature. In particular, an active high electrical conductivity carbon black loaded polyimide composites sandwiched between two insulating thin polymeric layers was used to condition the mold surface. By controlling the heating time, it was possible to control precisely the temporal variation of the mold temperature surface during the entire cycle. The surface heating rate was about 40°C/s and upon contact with the polymer the surface temperature decreased back to 40°C within about 5 s; the overall cycle time increased only slightly. The effect on cross section sample morphology of samples of iPP were analyzed and discussed on the basis of the recorded temperature evolution.
Test models of spacecraft to investigate thermal behavior, particularly Mariner temperature control model
Design engineer's handbook discusses passive temperature control techniques, selection of control surfaces, and environmental damage mechanisms.
Absorptivity standard instrument to investigate solar absorptance of four surfaces used for spacecraft temperature control for Mariner IV on Mars mission
Ames emissivity experiment on OSO-II to measure thermal radiation properties of temperature control coatings exposed to space environment
Purpose: To compare the single-fraction dose-related incidence of rectal obstruction and/or bleeding in normothermic and hypothermic rectums of a rat model. Methods and Materials: A 1.9-cm length of rectum was irradiated with a single fraction in 57 Sprague-Dawley rats using a dedicated image-guided small animal irradiator and Monte Carlo–based treatment planning system. All rats had a rectal temperature control apparatus placed during irradiation and were stratified to achieve either a normothermic (37°C) or hypothermic (15°C) rectal wall temperature. Radiation was delivered to a 1-cm-diameter cylindrical volume about the cooling device and rectal wall. The radiation dose was escalated from 16 Gy up to 37 Gy to assess the dose response in each arm. The primary endpoint of this study was rectal obstruction and/or bleeding during a follow-up of 180 to 186 days. Histologic scoring was performed on all study rats. Results: Probit analysis showed a dose associated with a 50% incidence of rectal obstruction of 24.6 Gy and 40.8 Gy for normothermic and hypothermic arms, respectively. The occurrence of obstruction and/or bleeding correlated with the posttreatment histologic score for normothermic rats; however, there was no difference in histologic score between normothermic and hypothermic rats at the highest dose levels evaluated. Conclusions: A significant radioprotective effect was observed using local hypothermia during a single large dose of radiation for the functional endpoint of rectal obstruction and/or bleeding. A confirmatory study in a large animal model with anatomic and physiologic similarities to humans is suggested.
Ames emissivity experiment on OSO-II to measure thermal radiation properties of temperature control coatings exposed to space environment
Absorptivity standard instrument to investigate solar absorptance of four surfaces used for spacecraft temperature control for Mariner IV on Mars mission
A robotic sample changer for solution X-ray scattering experiments optimized for speed and to use the minimum amount of material has been developed. This system is now in routine use at three high-brilliance European synchrotron sites, each capable of several hundred measurements per day. Small-angle X-ray scattering (SAXS) of macromolecules in solution is in increasing demand by an ever more diverse research community, both academic and industrial. To better serve user needs, and to allow automated and high-throughput operation, a sample changer (BioSAXS Sample Changer) that is able to perform unattended measurements of up to several hundred samples per day has been developed. The Sample Changer is able to handle and expose sample volumes of down to 5 µl with a measurement/cleaning cycle of under 1 min. The samples are stored in standard 96-well plates and the data are collected in a vacuum-mounted capillary with automated positioning of the solution in the X-ray beam. Fast and efficient capillary cleaning avoids cross-contamination and ensures reproducibility of the measurements. Independent temperature control for the well storage and for the measurement capillary allows the samples to be kept cool while still collecting data at physiological temperatures. The Sample Changer has been installed at three major third-generation synchrotrons: on the BM29 beamline at the European Synchrotron Radiation Facility (ESRF), the P12 beamline at the PETRA-III synchrotron (EMBL@PETRA-III) and the I22/B21 beamlines at Diamond Light Source, with the latter being the first commercial unit supplied by Bruker ASC.