At least 577 records · Page 32

Effects of gas–wall partitioning in Teflon tubing and instrumentation on time-resolved measurements of gas-phase organic compounds

Recent studies have demonstrated that organic compounds can partition from the gas phase to the walls in Teflon environmental chambers and that the process can be modeled as absorptive partitioning. Here these studies were extended to investigate gas–wall partitioning of organic compounds in Teflon tubing and inside a proton-transfer-reaction mass spectrometer (PTR-MS) used to monitor compound concentrations. Rapid partitioning of C 8 –C 14 2-ketones and C 11 –C 16 1-alkenes was observed for compounds with saturation concentrations ( c * ) in the range of 3 × 10 4 to 1 × 10 7 µg m -3 , causing delays in instrument response to step-function changes in the concentration of compounds being measured. These delays vary proportionally with tubing length and diameter and inversely with flow rate and c * . The gas–wall partitioning process that occurs in tubing is similar to what occurs in a gas chromatography column, and the measured delay times (analogous to retention times) were accurately described using a linear chromatography model where the walls were treated as an equivalent absorbing mass that is consistent with values determined for Teflon environmental chambers. The effect of PTR-MS surfaces on delay times was also quantified and incorporated into the model. The model predicts delays of an hour or more for semivolatile compounds measured under commonly employed conditions. These results and the model can enable better quantitative design of sampling systems, in particular when fast response is needed, such as for rapid transients, aircraft, or eddy covariance measurements. They may also allow estimation of c * values for unidentified organic compounds detected by mass spectrometry and could be employed to introduce differences in time series of compounds for use with factor analysis methods. Best practices are suggested for sampling organic compounds through Teflon tubing.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Hand tool permits shrink sizing of assembled tubing

Portable tool sizes tubing ends without disassembling the tubing installation. The shrink sizing tool is clamped to the tubing and operated by a ratchet wrench. A gear train forces the tubing end against an appropriate die or mandrel to effect the sizing.

Millett, A.↗

High pressure tube coupling requires no threads or flares

High pressure tube coupling connects to any straight, unthreaded, and unflared tubing end without deforming or damaging the tubing. The coupling grips the tube wall tightly between an external compression sleeve and an internal hollow mandrel. It is adaptable to standard screw fittings for test stand attachment.

Stein, J. A.↗

Gage tests tube flares quickly and accurately

Flared tube gage with a test cone that is precisely made with a tapering surface to complement the tube flare is capable of determining the accuracy of a tube flare efficiently and economically. This device should improve the speed, efficiency, and accuracy of tube flare inspections.

Griffin, F. D.↗

Tensile testing grips ensure uniform loading of bimetal tubing specimens

Tensile testing grip uniformly distributes stresses to the internal and external tube of bimetal tubing specimens. The grip is comprised of a slotted external tube grip, a slotted internal tube grip, a machine bolt and nut, an internal grip expansion cone, and an external grip compression nut.

Driscol, S. D.↗

Observations of actively forming lava tubes and associated structures, Hawaii, part 2

A ground examination is made of lave tubes and channels. The surface morphology and the changes noted through lava flow activity are cited, and compared to earlier aerial observations. The lava activity was believed to be caused by a small lava lake exposed by the collapse of a crust covering it. Drainage of the lake was caused by a fissure erruption. New tubes or extensions of existing ones were noted from the flow. Molten lava was not seen in any tubes examined on the ground, but some of the flows were not sufficiently cooled to allow subsurface examination and survey of the tubes.

Greeley, R.↗

Some important aspects in testing high-modulus fiber composite tubes designed for multiaxial loading

Tubular specimens were potted in metal grips to determine the feasibility of this gripping method in applying multiaxial loads. Strain gage rosettes were used to assess grip transitional strains, through thickness strain variation and strain variations along the tube length and circumference. The investigation was limited to loading 0 deg, + or - 45 deg, and 90 deg graphite/epoxy and glass/epoxy tubes in axial tension. Results include modifications made to the grips to reduce transitional strains, illustrations of the tube failure modes, and some material properties. The gripping concept shows promise as a satisfactory technique for applying multiaxial loads to high strength, high modulus fiber composite tubes.

Sullivan, T. L.↗

Analysis and testing of high entrainment single nozzle jet pumps with variable mixing tubes

An analytical model was developed to predict the performance characteristics of axisymmetric single-nozzle jet pumps with variable area mixing tubes. The primary flow may be subsonic or supersonic. The computer program uses integral techniques to calculate the velocity profiles and the wall static pressures that result from the mixing of the supersonic primary jet and the subsonic secondary flow. An experimental program was conducted to measure mixing tube wall static pressure variations, velocity profiles, and temperature profiles in a variable area mixing tube with a supersonic primary jet. Static pressure variations were measured at four different secondary flow rates. These test results were used to evaluate the analytical model. The analytical results compared well to the experimental data. Therefore, the analysis is believed to be ready for use to relate jet pump performance characteristics to mixing tube design.

Hickman, K. E.↗

A program for calculating expansion-tube flow quantities for real-gas mixtures and comparison with experimental results

A computer program written in FORTRAN 4 language is presented which determines expansion-tube flow quantities for real test gases CO2 N2, O2, Ar, He, and H2, or mixtures of these gases, in thermochemical equilibrium. The effects of dissociation and first and second ionization are included. Flow quantities behind the incident shock into the quiescent test gas are determined from the pressure and temperature of the quiescent test gas in conjunction with: (1) incident-shock velocity, (2) static pressure immediately behind the incident shock, or (3) pressure and temperature of the driver gas (imperfect hydrogen or helium). The effect of the possible existence of a shock reflection at the secondary diaphragm of the expansion tube is included. Expansion-tube test-section flow conditions are obtained by performing an isentropic unsteady expansion from the conditions behind the incident shock or reflected shock to either the test-region velocity or the static pressure. Both a thermochemical-equilibrium expansion and a frozen expansion are included. Flow conditions immediately behind the bow shock of a model positioned at the test section are also determined. Results from the program are compared with preliminary experimental data obtained in the Langley 6-inch expansion tube.

Miller, C. G., III↗

Some important aspects in testing high-modulus fiber composite tubes designed for multiaxial loading.

Tubular specimens were potted in metal grips to determine the feasibility of this gripping method in applying multiaxial loads. Strain gage rosettes were used to assess grip transitional strains, through thickness strain variation and strain variations along the tube length and circumference. The investigation was limited to loading 0, 45, plus or minus 45, and 90 deg graphite/epoxy and glass/epoxy tubes in axial tension. Results include modifications made to the grips to reduce transitional strains, illustrations of the tube failure modes, and some material properties. The gripping concept shows promise as a satisfactory technique for applying multiaxial loads to high-strength, high-modulus fiber composite tubes.

Sullivan, T. L.↗

Design, construction and evaluation of a 12.2 GHz, 4.0 kW-CW coupled-cavity traveling wave tube

An analytical and experimental program to study design techniques and to utilize these techniques to optimize the performance of an X-band 4 kW, CW traveling wave tube ultimately intended for satellite-borne television broadcast transmitters is described. The design is based on the coupled-cavity slow-wave circuit with velocity resynchronization to maximize the conversion efficiency. The design incorporates a collector which is demountable from the tube. This was done to facilitate multistage depressed collector experiments employing a NASA designed axisymmetric, electrostatic collector for linear beam microwave tubes after shipment of the tubes to NASA.

Ayers, W. R.↗

Total-pressure-tube averaging in pulsating flows.

A number of total-pressure tubes were tested in a nonsteady flow generator in which the fraction of period that pressure is a maximum is approximately 0.8, thereby simulating turbomachine-type flow conditions. The tests were performed at a pressure level of 1 bar, for Mach numbers up to near 1, and frequencies up to 3 kHz. Most of the tubes indicated a pressure which was higher than the true average. Organ-pipe resonances which further increased the indicated pressure were encountered within the tubes at discrete frequencies. There was no obvious combination of tube diameter, length, and/or geometry variation used in the tests which resulted in negligible averaging error. A pneumatic-type probe was found to measure true average pressure, and is suggested as a comparison instrument to determine whether nonlinear averaging effects are serious in unknown pulsation profiles.

Krause, L. N.↗

Some important aspects in testing high-modulus fiber composite tubes in axial tension.

Tubular specimens were potted in metal grips to determine the feasibility of this gripping method in applying multiaxial loads. Strain gage rosettes were used to assess grip transitional strains, through thickness strain variation, and strain variations along the tube length and circumference. The investigation was limited to loading graphite/epoxy and glass/epoxy tubes in axial tension. Results include modifications made to the grips to reduce transitional strains, illustrations of the tube failure modes, and some material properties. The gripping concept shows promise as a satisfactory technique for applying multiaxial loads to high-strength, high-modulus fiber composite tubes.

Sullivan, T. L.↗

Ultrasonic scanning system for in-place inspection of brazed tube joints

A miniaturized ultrasonic scanning system for nondestructive in-place, non-immersion testing of brazed joints in stainless-steel tubing is described. The system is capable of scanning brazed tube joints, with limited clearance access, in 1/4 through 5/8 inch union, tee, elbow and cross configurations. The system has the capability to detect defective conditions now associated with material density changes in addition to those which are depended upon density variations. The system includes a miniaturized scanning head assembly that fits around a tube joint and rotates the transducer around and down the joint in a continuous spiral motion. The C-scan recorder is similar in principle to conventional models except that it was specially designed to track the continuous spiral scan of the tube joint. The scanner and recorder can be operated with most commercially available ultrasonic flaw detectors.

Haynes, J. L.↗

An experimental investigation of wall boundary layer transition Reynolds numbers in an expansion tube

Experimental measurements of boundary-layer transition in an expansion-tube test-gas flow are presented along with radial distributions of pitot pressure. An integral method for calculating constant Reynolds number lines for an expansion-tube flow is introduced. Comparison of experimental data and constant Reynolds number calculations has shown that for given conditions, wall boundary-layer transition occurs at a constant Reynolds number in an expansion-tube flow. Operating conditions in the expansion tube were chosen so that the effects of test-gas nonequilibrium on boundary-layer transition could be studied.

Weilmuenster, K. J.↗

High-efficiency, 200 watt, 12-gigahertz traveling wave tube

Design and performance of a highly efficient experimental 200-watt traveling wave tube for space communications are described. The tube uses a coupled cavity slow wave structure with periodic permanent magnet focusing. A two-step velocity taper is incorporated in the slow wave structure for velocity resynchronization with the modulated beam. The spent beam is reconditioned in a refocusing section before it is collected in a novel multistage depressed collector. The collector is radiation cooled and heat insulated from the tube body. At saturation the tube provides peak output power of 240 watts with a 35-db gain and an overall maximum efficiency of 56 percent.

Kosmahl, H. G.↗

Studies of shock focusing and nonlinear resonance in shock tubes

Some current problems in noise pollution which involve the dynamics of weak shock waves can be succesfully investigated using shock tubes and shock-tube techniques. Two examples presently under study are discussed; in one case the experiments are carried out in a large, conventional shock tube originally designed for studies of rarefied gasdynamics, while in the other case the experimental facility is a less conventional 'repeating' shock tube.

Sturtevant, B.↗

Jupiter entry simulation with the ANAA shock tube

An annular arc accelerator (ANAA) shock tube has been built which produces shock velocities and pressures that simulate entry into the atmosphere of Jupiter. The ANAA driver deposits the energy of an arc discharge into a flowing gas, which then expands and cools without any delay for the opening of a diaphragm. A flow transducer, trigger system, and spark gap switches have been developed to coordinate the flow from a high-pressure helium driver with the discharge from a 300-kJ capacitor bank. Shock velocities up to 47 km/sec have been produced in 1.0 torr of hydrogen with the ANAA shock tube, compared with 35 km/sec velocity produced in a conical arc driver with three times the available energy. Attenuation with the ANAA shock tube is comparable to that of a conical arc driver shock tube, and initial spectroscopic measurements indicate that an impurity-free test slug is formed behind the shock wave.

Leibowitz, L. P.↗