Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “TIME MEASUREMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

System Measures Errors Between Time-Code Signals

System measures timing errors between signals produced by three asynchronous time-code generators. Errors between 1-second clock pulses resolved to 2 microseconds. Basic principle of computation of timing errors as follows: central processing unit in microcontroller constantly monitors time data received from time-code generators for changes in 1-second time-code intervals. In response to any such change, microprocessor buffers count of 16-bit internal timer.

Cree, David↗

TH-CD-207B-07: Noise Modeling of Single Photon Avalanche Diode (SPAD) for Photon Counting CT Applications

Purpose: Silicon photomultiplier (SiPM) has recently emerged as a promising photodetector for biomedical imaging applications. Due to its high multiplication gain (comparable to PMT), fast timing, low cost and compactness, it is considered a good candidate for photon counting CT. Dark noise is a limiting factor which impacts both energy resolution and detection dynamic range. Our goal is to develop a comprehensive model for noise sources for SiPM sensors. Methods: The physical parameters used in this work were based upon a test SPAD fabricated in 130nm CMOS process. The SPAD uses an n+/p-well junction, which is isolated from the p-substrate by a deep n-well junction. Inter-avalanche time measurement was used to record the time interval between two adjacent avalanche pulses. After collecting 1×106 counts, the histogram was obtained and multiple exponential fitting process was used to extract the lifetime associated with the traps within the bandgap. Results: At room temperature, the breakdown voltage of the SPAD is ∼11.4V and shows a temperature coefficient of 7.7mV/°C. The dark noise of SPAD increases with both the excess biasing voltage and temperature. The primary dark counts from the model were validated against the measurement results. A maximum relative error of 8.7% is observed at 20 °C with an excess voltage of 0.5V. The probabilities of after-pulsing are found to be dependent of both temperature and excess voltage. With 0.5V excess voltage, the after-pulsing probability is 63.5% at - 30 °C and drops to ∼6.6% at 40 °C. Conclusion: A comprehensive noise model for SPAD sensor was proposed. The model takes into account of static, dynamic and statistical behavior of SPADs. We believe that this is the first SPAD circuit simulation model that includes the band-to-band tunneling dark noise contribution and temporal dependence of the after-pulsing probability.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A simple technique for high resolution time domain phase noise measurement

A new time domain phase comparator is described. The device uses a novel technique to allow time domain phase measurements to be made with period and time interval counters without the use of offset reference oscillators. The device uses a single reference oscillator and allows measurements with a phase resolution greater than the noise floor of the reference. Data is presented showing a phase resolution of 0.02ps at 5 MHz with a crystal reference. The device has application in measuring the phase stability of systems where approximate phase quadrature can be maintained.

Reinhardt, V. S.↗

Time resolution of a 1-inch cylindrical CeBr{sub 3} crystal at {sup 60}Co energies

We have measured time resolutions of a cylindrical CeBr{sub 3} scintillator of 1-inch in height and 1-inch in diameter coupled to two different fast photomultiplier tubes, Hamamatsu R9779 and Photonis XP20D0, as a function of applied high voltages and different settings of a Constant Fraction Discriminator ORTEC 935. The time resolution was measured using a time-delayed coincidence set-up involving a fast reference detector. The best result of 119(2) ps at {sup 60}Co energies was obtained for the CeBr{sub 3} crystal coupled to the Hamamatsu PMT. This result is comparable to the resolution of 107 ps reported for a LaBr{sub 3}(Ce) crystal of the same size. For the coupling of the CeBr{sub 3} scintillator to the Photonis PMT we got the time resolution of 146(2) ps.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Retrospective Imaging and Characterization of Nuclear Material

Modern techniques for detection of covert nuclear ma-terial requires some combination of real time measurement and/or sampling of the material. More common is real time measure-ment of the ionizing emission caused by radioactive decay or through the materials measured in response to external interroga-tion radiation. One can expose the suspect material with various radiation types, including high energy photons such as x rays or with larger particles such as neutrons and muons, to obtain images or measure nuclear reactions induced in the material. Stand-off detection using imaging modalities similar to those in the medical field can be accomplished, or simple collimated detec-tors can be used to localize radioactive materials. In all such cases, the common feature is that some or all of the nuclear materials have to be present for the measurement, which makes sense; as one might ask, “How you can measure something that is not there?” The current work and results show how to do exactly that: characterize nuclear materials after they have been removed from an area leaving no chemical trace. This new approach is demon-strated to be fully capable of providing both previous source spa-tial distribution and emission energy grouping. The technique uses magnetic resonance for organic insulators and/or lumines-cence techniques on ubiquitous refractory materials similar in theory to the way the nuclear industry carries out worker person-nel dosimetry. Spatial information is obtained by acquiring gridded samples for dosimetric measurements, while energy infor-mation comes through dose depth profile results that are func-tions of the incident radiation energies.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Oscillation Detection Algorithm Development Summary Report and Test Plan

Small signal stability problems are one of the major threats to grid stability and reliability in California and the western U.S. power grid. An unstable oscillatory mode can cause large-amplitude oscillations and may result in system breakup and large-scale blackouts. There have been several incidents of system-wide oscillations. Of them, the most notable is the August 10, 1996 western system breakup produced as a result of undamped system-wide oscillations. There is a great need for real-time monitoring of small-signal oscillations in the system. In power systems, a small-signal oscillation is the result of poor electromechanical damping. Considerable understanding and literature have been developed on the small-signal stability problem over the past 50+ years. These studies have been mainly based on a linearized system model and eigenvalue analysis of its characteristic matrix. However, its practical feasibility is greatly limited as power system models have been found inadequate in describing real-time operating conditions. Significant efforts have been devoted to monitoring system oscillatory behaviors from real-time measurements in the past 20 years. The deployment of phasor measurement units (PMU) provides high-precision time-synchronized data needed for estimating oscillation modes. Measurement-based modal analysis, also known as ModeMeter, uses real-time phasor measure-ments to estimate system oscillation modes and their damping. Low damping indicates potential system stability issues. Oscillation alarms can be issued when the power system is lightly damped. A good oscillation alarm tool can provide time for operators to take remedial reaction and reduce the probability of a system breakup as a result of a light damping condition. Real-time oscillation monitoring requires ModeMeter algorithms to have the capability to work with various kinds of measurements: disturbance data (ringdown signals), noise probing data, and ambient data. Several measurement-based modal analysis algorithms have been developed. They include Prony analysis, Regularized Ro-bust Recursive Least Square (R3LS) algorithm, Yule-Walker algorithm, Yule-Walker Spectrum algorithm, and the N4SID algo-rithm. Each has been shown to be effective for certain situations, but not as effective for some other situations. For example, the traditional Prony analysis works well for disturbance data but not for ambient data, while Yule-Walker is designed for ambient data only. Even in an algorithm that works for both disturbance data and ambient data, such as R3LS, latency results from the time window used in the algorithm is an issue in timely estimation of oscillation modes. For ambient data, the time window needs to be longer to accumulate information for a reasonably accurate estimation; while for disturbance data, the time window can be significantly shorter so the latency in estimation can be much less. In addition, adding a known input signal such as noise probing signals can increase the knowledge of system oscillatory properties and thus improve the quality of mode estimation. System situations change over time. Disturbances can occur at any time, and probing signals can be added for a certain time period and then removed. All these observations point to the need to add intelligence to ModeMeter applications. That is, a ModeMeter needs to adaptively select different algorithms and adjust parameters for various situations. This project aims to develop systematic approaches for algorithm selection and parameter adjustment. The very first step is to detect occurrence of oscillations so the algorithm and parameters can be changed accordingly. The proposed oscillation detection approach is based on the signal-noise ratio of measurements.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Neutron Time-of-Flight Measurements of Charged-Particle Energy Loss in Inertial Confinement Fusion Plasmas

Neutron spectra from secondary 3 H(d,n)α reactions produced by an implosion of a deuterium-gas capsule at the National Ignition Facility have been measured with order-of-magnitude improvements in statistics and resolution over past experiments. Furthermore, these new data and their sensitivity to the energy loss of fast tritons emitted from thermal 2 H(d,p) 3 H reactions enable the first statistically significant investigation of charged-particle stopping via the emitted neutron spectrum. Radiation-hydrodynamic simulations, constrained to match a number of observables from the implosion, were used to predict the neutron spectra while employing two different energy loss models. This analysis represents the first test of stopping models under inertial confinement fusion conditions, covering plasma temperatures of k B T ≈ 1–4 keV and particle densities of n ≈ (12–2) × 10 24 cm –3 . Under these conditions, we find significant deviations of our data from a theory employing classical collisions whereas the theory including quantum diffraction agrees with our data.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Bioelectric signal analysis and measurement

Nonstationary time series techniques are used to analyze EEG signals for the estimation of alertness. A time varying order is extracted in sequential time series measurement of these data and strategies are devised for obtaining optimal representation of the EEG signal.

Lai, D. C.↗

On the measurement of pilot perceptual workload - A comparison of assessment techniques addressing sensitivity and intrusion issues

A flight simulator-based study was conducted to examine fourteen distinct mental workload estimation measures, including opinion, secondary task, physiological, and primary task measures. Both the relative sensitivity of the measures to changes in mental workload and the differential intrusion of the changes on primary task performance were assessed. The flight task was varied in difficulty by manipulation of the presentation rate and complexity of a hazard-perception task that required each of 48 licensed pilots to rely heavily on their perceptual abilities. Three rating scales (Modified Cooper-Harper, Multi-descriptor, and Workload-Compensation-Interference/Technical Effectiveness), two secondary task measures (time estimation and tapping regularity), one physiological measure (respiration frequency), and one primary task measure (danger-condition response time) were reliable indicants of workload changes. Recommendations for applying the workload measures are presented.

Casali, J. G.↗

Stability and Phase Noise Tests of Two Cryo-Cooled Sapphire Oscillators

A cryocooled Compensated Sapphire Oscillator (CSO), developed for the Cassini Ka-band Radio Science experiment, and operating in the 8K - 10K temperature range was previously demonstrated to show ultra-high stability of sigma(sub y) = 2.5 x 10 (exp -15) for measuring times 200 seconds less than or equal to tau less than or equal to 600 seconds using a hydrogen maser as reference. We present here test results for a second unit which allows CSO short-term stability and phase noise to be measured for the first time. Also included are design details of a new RF receiver and an intercomparison with the first CSO unit. Cryogenic oscillators operating below about 10K offer the highest possible short term stability of any frequency sources. However, their use has so far been restricted to research environments due to the limited operating periods associated with liquid helium consumption. The cryocooled CSO is being built in support of the Cassini Ka-band Radio Science experiment and is designed to operate continuously for periods of a year or more. Performance targets are a stability of 3-4 x 10 (exp -15) (1 second less than or equal to tau less than or equal to 100 seconds) and phase noise of -73dB/Hz @ 1Hz measured at 34 GHz. Installation in 5 stations of NASA's deep space network (DSN) is planned in the years 2000 - 2002. In the previous tests, actual stability of the CSO for measuring times tau less than or equal to 200 seconds could not be directly measured, being masked by short-term fluctuations of the H-maser reference. Excellent short-term performance, however, could be inferred by the success of an application of the CSO as local oscillator (L.O.) to the JPL LITS passive atomic standard, where medium-term stability showed no degradation due to L.O. instabilities at a level of (sigma)y = 3 x 10 (exp -14)/square root of tau. A second CSO has now been constructed, and all cryogenic aspects have been verified, including a resonator turn-over temperature of 7.907 K, and Q of 7.4 x 10 (exp 8). These values compare to a turn-over of 8.821 K and Q of 1.0 x 10 (exp 9) for the first resonator. Operation of this second unit provides a capability to directly verify for the first time the short-term (1 second less than or equal to tau less than or equal to 200 seconds) stability and the phase noise of the CSO units. The RF receiver used in earlier tests was sufficient to meet Cassini requirements for tau greater than or equal to 10 seconds but had short-term stability limited to 2-4 x 10 (exp -14) at tau = 1 second, a value 10 times too high to meet our requirements. A new low-noise receiver has been designed to provide approximately equal to 10-15 performance at 1 second, and one receiver is now operational, demonstrating again short-term CSO performance with H maser-limited stability. Short-term performance was degraded in the old receiver due to insufficient tuning bandwidth in a 100MHZ quartz VCO that was frequency-locked to the cryogenic sapphire resonator. The new receivers are designed for sufficient bandwidth, loop gain and low noise to achieve the required performance.

Dick, G. John↗

Correlating Time-Resolved Pressure Measurements With Rim Sealing Effectiveness for Real-Time Turbine Health Monitoring

Purge flow is bled from the upstream compressor and supplied to the under-platform region to prevent hot main gas path ingress that damages vulnerable under-platform hardware components. A majority of turbine rim seal research has sought to identify methods of improving sealing technologies and understanding the physical mechanisms that drive ingress. While these studies directly support the design and analysis of advanced rim seal geometries and purge flow systems, the studies are limited in their applicability to real-time monitoring required for condition-based operation and maintenance. As operational hours increase for in-service engines, this lack of rim seal performance feedback results in progressive degradation of sealing effectiveness, thereby leading to reduced hardware life. To address this need for rim seal performance monitoring, this study utilizes measurements from a one-stage turbine research facility operating with true-scale engine hardware at engine-relevant conditions. Time-resolved pressure measurements collected from the rim seal region are regressed with sealing effectiveness through the use of common machine learning techniques to provide real-time feedback of sealing effectiveness. Two modeling approaches are presented that use a single sensor to predict sealing effectiveness accurately over a range of two turbine operating conditions. Here, the results show that an initial purely data-driven model can be further improved using domain knowledge of relevant turbine operations, which yields sealing effectiveness predictions within 3% of measured values.

42 ENGINEERING↗

Correlating Time-Resolved Pressure Measurements With Rim Sealing Effectiveness for Real-Time Turbine Health Monitoring

Purge flow is bled from the upstream compressor and supplied to the under-platform region to prevent hot main gas path ingress that damages vulnerable under-platform hardware components. A majority of turbine rim seal research has sought to identify methods of improving sealing technologies and understanding the physical mechanisms that drive ingress. While these studies directly support the design and analysis of advanced rim seal geometries and purge flow systems, the studies are limited in their applicability to real-time monitoring required for condition-based operation and maintenance. As operational hours increase for in-service engines, this lack of rim seal performance feedback results in progressive degradation of sealing effectiveness, thereby leading to reduced hardware life. To address this need for rim seal performance monitoring, the present study utilizes measurements from a one-stage turbine research facility operating with true-scale engine hardware at engine-relevant conditions. Time-resolved pressure measurements collected from the rim seal region are regressed with sealing effectiveness through the use of common machine learning techniques to provide real-time feedback of sealing effectiveness. Two modelling approaches are presented that use a single sensor to predict sealing effectiveness accurately over a range of two turbine operating conditions. Results show that an initial purely data-driven model can be further improved using domain knowledge of relevant turbine operations, which yields sealing effectiveness predictions within three percent of measured values.

Compressors↗

Measurements of Pilot Time Delay as Influenced by Controller Characteristics and Vehicles Time Delays

A study to measure and compare pilot time delay when using a space shuttle rotational hand controller and a more conventional control stick was conducted at NASA Ames Research Center's Dryden Flight Research Facility. The space shuttle controller has a palm pivot in the pitch axis. The more conventional controller used was a general-purpose engineering simulator stick that has a pivot length between that of a typical aircraft center stick and a sidestick. Measurements of the pilot's effective time delay were obtained through a first-order, closed-loop, compensatory tracking task in pitch. The tasks were implemented through a space shuttle cockpit simulator and a critical task tester device. The study consisted of 450 data runs with four test pilots and one nonpilot, and used three control stick configurations and two system delays. Results showed that the heavier conventional stick had the lowest pilot effective time delays associated with it, whereas the shuttle and light conventional sticks each had similar higher pilot time delay characteristics. It was also determined that each control stick showed an increase in pilot time delay when the total system delay was increased.

Privoznik, C. M.↗

James Webb Space Telescope Studies of Dark Energy

The Hubble Space Telescope (HST) has contributed significantly to studies of dark energy. It was used to find the first evidence of deceleration at z=1.8 (Riess et al. 2001) through the serendipitous discovery of a type 1a supernova (SN1a) in the Hubble Deep Field. The discovery of deceleration at z greater than 1 was confirmation that the apparent acceleration at low redshift (Riess et al. 1998; Perlmutter et al. 1999) was due to dark energy rather than observational or astrophysical effects such as systematic errors, evolution in the SN1a population or intergalactic dust. The GOODS project and associated follow-up discovered 21 SN1a, expanding on this result (Riess et al. 2007). HST has also been used to constrain cosmological parameters and dark energy through weak lensing measurements in the COSMOS survey (Massey et al 2007; Schrabback et al 2009) and strong gravitational lensing with measured time delays (Suyu et al 2010). Constraints on dark energy are often parameterized as the equation of state, w = P/p. For the cosmological constant model, w = -1 at all times; other models predict a change with time, sometimes parameterized generally as w(a) or approximated as w(sub 0)+(1-a)w(sub a), where a = (1+z)(sup -1) is the scale factor of the universe relative to its current scale. Dark energy can be constrained through several measurements. Standard candles, such as SN1a, provide a direct measurement of the luminosity distance as a function of redshift, which can be converted to H(z), the change in the Hubble constant with redshift. An analysis of weak lensing in a galaxy field can be used to derive the angular-diameter distance from the weak-lensing equation and to measure the power spectrum of dark-matter halos, which constrains the growth of structure in the Universe. Baryonic acoustic oscillations (BAO), imprinted on the distribution of matter at recombination, provide a standard rod for measuring the cosmological geometry. Strong gravitational lensing of a time-variable source gives the angular diameter distance through measured time delays of multiple images. Finally, the growth of structure can also be constrained by measuring the mass of the largest galaxy clusters over cosmic time. HST has contributed to the study of dark energy through SN1a and gravitational lensing, as discussed above. HST has also helped to characterize galaxy clusters and the HST-measured constraints on the current Hubble constant H(sub 0) are relevant to the interpretation of dark energy measurements (Riess et al 2009a). HST has not been used to constrain BAO as the large number of galaxy redshifts required, of order 100 million, is poorly matched to HST's capabilities. As the successor to HST, the James Webb Space Telescope (JWST; Gardner et al 2006) will continue and extend HST's dark energy work in several ways.

Gardner, Jonathan P.↗

A Combined Neutron and Gamma-Ray Multiplicity Counter Based on Liquid Scintillation Detectors

Multiplicity counters for neutron assay have been extensively used in materials control and accountability for nonproliferation and nuclear safeguards. Typically, neutron coincidence counters are utilized in these fields. In this work, we present a measurement system that makes use not only of neutron (n) multiplicity counting but also of gamma-ray (g) multiplicity counting and the combined higher-order multiples containing both neutrons and gamma rays. The benefit of this approach is in using both particle types available from the sample, leading to a reduction in measurement times needed when using more measurables. We present measurement results of n, g, nn, ng, gg, nnn, nng, ngg, and ggg multiples emitted by Mixed-Oxide (MOX) samples measured at Idaho National Laboratory (INL). The MOX measurement is compared to initial validation of the detection system done using a 252Cf source. The dual radiation measuring system proposed here uses extra measurables to improve the statistics when compared to a neutron-only system and allows for extended analysis and interpretation of sample parameters. New challenges such as the effect of very high intrinsic gamma-ray sources in the case of MOX samples is discussed. Successful measurements of multiples rates can be performed also when using high-Z shielding.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Time-resolved synchrotron light source X-ray detection with Low-Gain Avalanche Diodes

Low Gain Avalanche Diodes (LGADs) represent the state-of-the-art in timing measurements and will instrument future timing detectors at the High Luminosity Large Hadron Collider (HL-LHC) experiments. While conceived as a sensor for charged particles, the intrinsic gain of LGADs makes it possible to detect low energy X-rays with good energy resolution and excellent timing (tens of picoseconds). Here, using the Stanford Synchrotron Radiation Lightsource (SSRL) at SLAC, several LGADs designs were characterized with energies from 5 to 35 keV. The SSRL provides 10 ps pulsed X-ray bunches separated by 2.1 ns intervals, and with an energy dispersion (ΔE/E) of 1 X 10 -4 . LGADs fabricated by Hamamatsu Photonics (HPK) and Brookhaven National Laboratory (BNL) with different thicknesses ranging from 20 µm to 50 µm and different gain layer designs were read out a two stage fast amplification circuit and digitized with a high bandwidth, high sampling rate oscilloscope. PIN devices from HPK were characterized as well. A systematic and detailed characterization of the devices’ energy linearity, resolution and timing resolution as a function of X-ray energy was performed for different biasing voltages at room temperature

Charge multiplication↗

Temperature dependent and time-resolved photoluminescence studies of InAs self-assembled quantum dots with InGaAs strain reducing layer structure

Four types of self-assembled InAs/GaAs quantum dots (QDs) were grown by molecular beam epitaxy and studied via temperature-dependent and time-resolved photoluminescence (PL) spectroscopy measurements. A thin InGaAs stain reducing layer (SRL) is adopted which extends the emission wavelength to 1.3 mum and the influence of strain on QDs is investigated. The SRL releases the strain between the wetting layer and QDs, and enlarges the size of QDs, as shown by atomic force microscopy measurements. As the thickness of InAs layer decreases to 1.7 ML, the QDs with the SRL are chained to strings and the density of QDs increases significantly, which leads to an abnormal redshift of 1.3 mum PL peak at room temperature. PL peaks of InAs QDs with the SRL show redshift compared with the QDs directly deposited on GaAs matrix. The dependences of PL lifetime on the QD size, density and temperature (T) are systematically studied. It is observed that the PL lifetime of QDs is insensitive to T below 50 K. Beyond 50 K, increases and then drops at higher temperature, with a peak at T{sub C}, which was determined by the SRL and the thickness of InAs. We have also observed an obvious PL spectral redshift of the QDs with 1.7 ML InAs coverage on SRL at low T as the measuring time delays. The PL lifetime of QDs with the SRL is smaller than that of QDs without the SRL. The QDs with different densities have different PL lifetime dependence on the QDs size. These observations can be explained by the competition between the carrier redistribution and thermal emission.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Probing the lattice structure of dynamically compressed and released single crystal iron through the alpha to epsilon phase transition

In this work, experiments using broadband Laue x-ray diffraction (XRD) were used to examine the lattice structure of dynamically compressed [100]-oriented single crystal iron samples at the Dynamic Compression Sector at the Advanced Photon Source. These experiments used 1 μm thick iron single crystal samples sandwiched between a polyimide ablator and a polycarbonate window. A 100 J, 10 ns duration laser pulse incident on the polyimide ablator was used to shock compress the iron samples to initial stresses greater than 25 GPa, exceeding the ~13 GPa alpha (body-centered-cubic or bcc structure) to epsilon (hexagonal-close-packed or hcp structure) phase transition stress. XRD measurements were performed at various times relative to the shock wave entering the iron sample: early times, <~150 ps while the initial shock waves propagated through the iron; intermediate times, after the iron equilibrated with the ablator and window reaching a plateau stress state (12 or 17 GPa) lasting several nanoseconds; and late times, during uniaxial strain release. The early time measurements show that in <~150 ps, the high-pressure hcp phase is relaxed with a c/a ratio of 1.61, contrary to previous laser shock experiments where a c/a ratio of 1.7 was inferred. In the plateau stress state and partially released states, XRD measurements showed that the hcp structure retained a c/a ratio of 1.61 with no observable changes in the microstructure. Upon stress release at ~1 GPa/ns release rate, the reverse phase transition (hcp to bcc) to the original single crystal orientation (implying a transformation memory effect) was observed to reach completion somewhere between 13 and 11 GPa, indicating little stress hysteresis under rapid uniaxial strain release. A similar memory effect for the reverse hcp to bcc transformation has been previously observed under hydrostatic compression. However, the bcc/hcp orientation relationships differ somewhat between dynamic and static compression experiments, implying that the transformation pathway under uniaxial dynamic strain differs from the Burgers mechanism.

36 MATERIALS SCIENCE↗