Use of high throughput screening methods to study dual-functional crosslinkable latexes

Herein, structure-formulation-property relationships for crosslinkable core-shell latexes were studied initially using high throughput screening methods and then using conventional experimental methods to determine optimum coating formulations. Two approaches that are used within coatings technology to improve sustainability are reduction in volatile organic compounds (VOC) and reduction in energy needed to cure coatings. Hybrid crosslinkable core-shell latexes have shown potential in meeting these challenges where film properties provided by particle coalescence are not sufficient and chemical crosslinking is needed. However, with numerous parameters involved such as latex particle architecture, nature and amount of crosslinker, and curing conditions, the screening of formulations via conventional coating testing methods becomes laborious and time-consuming. The results from high-throughput dye extraction and puncture testing were compared to data from conventional testing methods such as chemical resistance (MEK double rubs), pendulum hardness, and tensile testing to identify correlations. The dye extraction results have shown a strong correlation to solvent resistance and pendulum hardness data whereas toughness from puncture testing data correlated to tensile testing. Both high throughput dye extraction and puncture testing methods can be used for the accelerated screening of crosslinkable coating formulations to optimize curing parameters to achieve the best coating performance.

36 MATERIALS SCIENCE↗

An Investigation to Improve Quality Evaluations of Primers and Propellant for 20mm Munitions

To reduce the frequency of electrically initiated, 20mm munition hangfires (delayed ignitions), a joint Army/NASA investigation was conducted to recommend quality evaluation improvements for acceptance of both primers and gun propellant. This effort focused only on evaluating ignition and combustion performance as potential causes of hangfires: poor electrical initiation of the primer, low output performance of the primer, low ignition sensitivity of the gun propellant, and the effects of cold temperature. The goal was to determine the "best" of the Army and NASA test methods to assess the functional performance of primers and gun propellants. The approach was to evaluate the performance of both high-quality and deliberately defective primers to challenge the sensitivity of test methods. In addition, the ignition sensitivity of different manufacturing batches of gun propellants was evaluated. The results of the investigation revealed that improvements can be made in functional evaluations that can assist in identifying and reducing ignition and performance variations. The "best" functional evaluation of primers and propellant is achieved through a combination of both Army and NASA test methods. Incorporating the recommendations offered in this report may provide for considerable savings in reducing the number of cartridge firings, while significantly lowering the rejection rate of primer, propellant and cartridge lots. The most probable causes for ignition and combustion-related hangfires were the lack of calcium silicide in the primer mix, a low output performance of primers, and finally, poor ignition sensitivity of gun propellant. Cold temperatures further reduce propellant ignition sensitivity, as well as reducing burn rate and chamber pressures.

Bement, L. J.↗

Dynamic Thermal Performance Analysis of PCM Products Used for Energy Efficiency and Internal Climate Control in Buildings

PCMs are attractive for the future generation of buildings, where energy efficiency targets and thermal comfort expectations are increasingly prioritized. Experimental analysis of local thermal processes in these dynamic components and whole-building energy consumption predictions are essential for the proper implementation of PCMs in buildings. This paper discusses the experimental analysis of the thermophysical characteristics of both a latent heat storage material (PCM) and a product containing this PCM. The prototype product under investigation is a panelized PCM technology containing inorganic, salt-hydrate-based PCM. The thermal analysis includes studies of melting and freezing temperatures, enthalpy changes during phase change processes, nucleation intensity, sub-cooling effects, and PCM stability. The PCM’s stability is also investigated, as is the ability of PCM products to control local temperatures and peak load transmission times. Two inorganic PCM formulations based on calcium chloride hexahydrate (CaCl 2 .6H 2 O) were prepared and tested in laboratory conditions. Material-scale testing results were compared with outcomes from the system-scale analysis, using both laboratory test methods as well as field exposure in test huts. This work demonstrates that PCM technologies used in buildings can effectively control both the magnitude of thermal storage capacity as well as the time of the peak thermal load. It was found that commonly used material-scale testing methods may not always be beneficial in assessing the dynamic thermal performance characteristics of building technologies containing PCMs.

42 ENGINEERING↗

VLA stereoscopy of solar active regions. 1: Method and tests

We develop a new technique for extracting three-dimensional information from multiday solar Very Large Array (VLA) observations. While standard stereoscopic methods provide a three-dimensional view of an object by combining simultaneous observations from two different aspect angles, we relax the condition of simultaneity and exploit solar rotation to vary the aspect angle. The solar radio images are decomposed into Gaussian source components, which are then cross-correlated in maps from preceding and following days. This provides measurements of the three-dimensional position of correlated source centroids. In this first paper, we describe the stereoscopic method and perform tests with simulated and real radio maps (from the VLA at 20 cm), in order to study the accuracy of altitude measurements, and the limitations introduced by (i) source confusion, (ii) source motion, and (iii) the assumed differential rotation rate. The tests demonstrate that (i) the information content of a VLA map relevant for stereoscopic correlation can be conveniently represented in terms of a small number of Gaussian components; (ii) the fitting of the three-dimensional source position is stable within a numerical accuracy of less than or approximately equal to 0.02 map pixels, (iii) the relative accuracy of the altitude determination is uniform over the solar disk, and (iv) source confusion does not affect the accuracy of stereoscopic position measurements for sources with a signal-to-noise ratio of greater than or approximately equal to 36.

Aschwanden, Markus J.↗

Convective Heat Transfer Scaling of Ignition Delay and Burning Rate with Heat Flux and Stretch Rate in the Equivalent Low Stretch Apparatus

To better evaluate the buoyant contributions to the convective cooling (or heating) inherent in normal-gravity material flammability test methods, we derive a convective heat transfer correlation that can be used to account for the forced convective stretch effects on the net radiant heat flux for both ignition delay time and burning rate. The Equivalent Low Stretch Apparatus (ELSA) uses an inverted cone heater to minimize buoyant effects while at the same time providing a forced stagnation flow on the sample, which ignites and burns as a ceiling fire. Ignition delay and burning rate data is correlated with incident heat flux and convective heat transfer and compared to results from other test methods and fuel geometries using similarity to determine the equivalent stretch rates and thus convective cooling (or heating) rates for those geometries. With this correlation methodology, buoyant effects inherent in normal gravity material flammability test methods can be estimated, to better apply the test results to low stretch environments relevant to spacecraft material selection.

Olson, Sandra↗

Explosive decomposition of hydrazine due to rapid gas compression

Results from tests which attempt to determine conditions which cause explosive decomposition of hydrazine from rapid gas compression are described. Hydrazine was initiated by pressure in combination with shock waves from the pressurant gas. A new test method was developed at the White Sands Test Facility which subjects a gas bubble in contact with liquid hydrazine to pure adiabatic compression. Results from this new test method are compared to those from the U-tube method.

Briles, O.↗

Quiet Sonic Booms: A NASA and Industry Progress Report

The purpose of this Oral Presentation is to present a progress report on NASA and Industry efforts related to Quiet Sonic Boom Program activities. This presentation will review changes in aircraft shaping to produce quiet supersonic booms and associated supersonic flight test methods and results. In addition, new flight test profiles have been recently developed that have allowed for the generation of sonic booms of varying intensity. These new flight test profiles have allowed for ground testing of the response of various building structures to sonic booms and the associated public acceptability to various sonic boom intensities. The new flight test profiles and associated ground measurement test methods will be reviewed. Finally, this Oral Presentation will review the International Regulatory requirements that would be involved to change aviation regulation and allow for overland quiet supersonic flight.

Larson, David Nils↗

ORNL Quasi-Static Mechanical Characterization and Analysis: FY09 Annual Report to TARDEC

The testing and evaluation of candidate glasses for transparent armor served as a primary goal. Other armor ceramics were evaluated too, in support of the development of innovative test methods, whose use will ultimately help in the improvement of armor ceramics or help in better predicting their ballistic performance. The following summarizes this report and this year's work: (1) The elastic properties of a spherical indenter affect the forces necessary to initiate fracture in a target ceramics. The lower the elastic modulus of an indenter material, the easier (i.e., lower forces required) it is to initiate fracture. This implies the fracture initiation of an armor ceramic will depend on the elastic properties of a projectile material, and that this effect, represented by the Dundurs Parameter, can be managed to guide improvement of both armor and projectile materials. (2) The largest flaws in a population dictate both contact damage and fracture initiations. This implies the ballistic response of armor ceramics will improve if those large flaws are precluded from appearing in the materials during their processing. (3) Failure stress dependence on effective area for Hertzian indentation was developed. Such analysis is adaptable to predict ballistically produced fracture initiation as a function of projectile material and projectile size. (4) A simple, quick, and inexpensive test method was developed to measure the apparent yield stress of armor ceramics. This is significant because yield stress is used as input in ballistic models, and yield stress is traditionally measured using (complex, timeconsuming, and expensive) shock physics experiments. (5) Radial confinement increases the necessary indentation forces to initiate fracture and yield-like responses in ceramics. Ballistic improvement of an armor ceramic will occur if the ceramic can be compressively pre-stressed. (6) The median crack produced by a Hertzian indent is associated with a dramatic increase in target ceramic compliance. More so than any other produced damage mechanism. This suggests that a ballistically induced median crack in an armor ceramic may be associated with the dwell penetration event. (7) Glass exhibits tensile strength that is very much dependent on the amount of material, the side being tested (air versus tin if a float glass), and where it is being tensile stressed (in the middle or near an edge). The management of these effects will improve ballistic resistance of transparent armor (or any ceramic armor that is undergoing deflection as a consequence of a ballistic impact). (8) Plasma-arc heat treatment is a quick and relatively inexpensive method to improve the strength of glass. It is implementable into the production line for the mass production of glass. Increased strain-to-failure and bending deflections are concomitant with increased strength, and therefore, ballistic resistance is improvable using this method. (9) The Hertzian stress field at high contact stresses is very similar to the stress field from a ballistic impact. This is significant because the results from Hertzian indentation measurements have the prospect of being used as input in ballistic models to predict dwell conditions. (10) The understanding of glass densification and fragmentation behaviors are aided by piezo-Raman spectroscopy and quasi-static, high-energy fracture. Continued refinement of these test methods will improve the understanding of glass impact resistance. (11) In addition to glass, strength-size scaling was evident in SiC and B{sub 4}C. Previously proposed strength dependencies on rate from shock experiments may instead be explained by this strength-size scaling effect. (12) The quantification of strength-size scaling in armor ceramics clearly shows there is no single strength value that can be used to describe that ceramic. A ballistic modeler can therefore use more appropriate failure stress value(s) as input to predict deflection and expanding cavity responses in the ceramic target. These follow-on efforts are recommended based on the above statements: (1) Dynamic Hertzian indentation using a dynamic hardness tester; (2) Quantify flaw population size in strategic armor ceramics; (3) Refine and increase robustness of apparent yield stress measurement; (4) Quantify fracture and yield processed in armor ceramics as a function of confined stress; (5) Develop test method to accurately measure stress condition of median crack formation; (6) Measure strength-size scaling in glass ceramic candidates for transparent armor; (7) Refine plasma-arc heat treating to maximize strengthening of glasses and glass ceramics; (8) Refine ballistic modeling analysis to improve adaptability of Hertzian indentation results; (9) Refine densification and fragmentation test methods and interpretations; and (10) Predict ballistically-induced armor deflection and expanding cavity performance using strength-size scaling results.

36 MATERIALS SCIENCE↗

Blower-door techniques for measuring interzonal leakage

Abstract The standard blower door test methods, such as ASTM E779, describe how to use a single blower door to determine the total leakage of a single-zone structure such as a detached single-family home. There are no standard test methods for measuring interzonal leakage in a two-zone or multi-zone building envelope such as might be encountered in with an attached garage or in a multifamily building. Some practitioners have been using techniques that involve making multiple measurements with a single blower door as well as combined measurements using multiple blower doors. Even for just two zones there are dozens of combinations of one-door and two-door test protocols that could conceivably be used to determine the interzonal air tightness. We examined many of these two-zone configurations using both simulation and measured data to estimate the accuracy and precision of each technique for realistic measurement scenarios. We also considered the impact of taking measurements at a single pressure versus over multiple pressures. We compared the various techniques and evaluated them for specific uses. Some techniques work better in one leakage regime; some are more sensitive to wind and other noise; some are more suited to determining only a subset of the leakage values. This paper makes recommendations on which techniques to use or not use for various cases and provides data that could be used to develop future test methods.

99 GENERAL AND MISCELLANEOUS↗

A methodology for selection of solid desiccants in energy recovery ventilators

Controlling indoor humidity levels is essential for maintaining acceptable indoor air quality in buildings. The use of energy recovery ventilators (ERVs) is an energy-efficient way to regulate indoor air humidity. Fixed-bed regenerators and rotary wheels are widely used ERVs because of their high sensible and latent effectiveness. These ERVs are made of desiccant-coated substrates, which enable them to transfer moisture between the supply and exhaust air streams. However, the moisture transfer ability of ERVs depends on the physiochemical and sorption properties of desiccants. Extensive, full-scale experiments are required to determine the best desiccant material for these systems. This paper presents a simplified method of selecting suitable desiccant materials for ERVs. The methodology involves important characterization methods, literature correlations for performance prediction, and cost-effective testing methods prior to full-scale testing, and full-scale test methods are discussed in detail. Furthermore, the performance of a few newly derived materials is evaluated and compared with that of conventional desiccants such as silica gel and molecular sieves. The highest latent effectiveness was obtained for composite of super absorbent polymer (SAP) with potassium formate (SAP-HCO2K-50 %), all-polymer porous solid desiccant (APPSD) and metal organic framework (MOF)–MIL–101 (Cr), followed by activated carbon fibre felt (ACFF) Silica sol-LiCl30, SAP, silica gel, MOF–303, and molecular sieve. Researchers and manufacturers would benefit from the proposed methodology and presented data in developing new desiccant materials for ERV applications.

Energy recovery↗

Remotely Administered Psychoacoustic Test for sUAS Noise to Gauge Feasibility of Remote UAM Noise Study

The National Aeronautics and Space Administration (NASA) remotely administered a psychoacoustic test in fall of 2022 as the first of two phases of a cooperative Urban Air Mobility (UAM) vehicle noise human response study. The first phase, the Feasibility Test, described in this paper, determined the feasibility of the remote test method, in contrast to a previous in-person psychoacoustic test that found an annoyance response difference between small unmanned aerial system (sUAS) noise and ground vehicle noise. This paper discusses the Feasibility Test online layout, sound calibration method, remote test software development, stimuli selection, test subject recruitment, and test administration. Test performance is measured through comparison of annoyance response data with the previous in-person test results. The paper also investigates if providing a contextual cue to test subjects influenced their annoyance response. Response differences between test subjects in geographically distinct areas are analyzed. Administrative challenges that were encountered during the test are discussed. The second phase of this study, the implementation phase, will use a remote (web-based) test method and leverage the cooperation of multiple government agencies, academia, and industry to gain human response insights from a wide range of UAM vehicle sounds that would be challenging for a single organization to acquire. Improvements to administering a remote test for the implementation phase of the UAM vehicle noise human response study are recommended.

Remote Psychoacoustic Test↗

Remotely Administered Psychoacoustic Test for sUAS Noise to Gauge Feasibility of Remote UAM Noise Study

The National Aeronautics and Space Administration (NASA) remotely administered a psychoacoustic test in fall of 2022 as the first of two phases of a cooperative Urban Air Mobility (UAM) vehicle noise human response study. The first phase, the Feasibility Test, described in this paper, determined the feasibility of the remote test method, in contrast to a previous in-person psychoacoustic test that found an annoyance response difference between small unmanned aerial system (sUAS) noise and ground vehicle noise. This paper discusses the Feasibility Test online layout, sound calibration method, remote test software development, stimuli selection, test subject recruitment, and test administration. Test performance is measured through comparison of annoyance response data with the previous in-person test results. The paper also investigates if providing a contextual cue to test subjects influenced their annoyance response. Response differences between test subjects in geographically distinct areas are analyzed. Administrative challenges that were encountered during the test are discussed. The second phase of this study, the implementation phase, will use a remote (web-based) test method and leverage the cooperation of multiple government agencies, academia, and industry to gain human response insights from a wide range of UAM vehicle sounds that would be challenging for a single organization to acquire. Improvements to administering a remote test for the implementation phase of the UAM vehicle noise human response study are recommended.

Remote Psychoacoustic Test↗

Integrating Formal Methods and Testing 2002

Traditionally, qualitative program verification methodologies and program testing are studied in separate research communities. None of them alone is powerful and practical enough to provide sufficient confidence in ultra-high reliability assessment when used exclusively. Significant advances can be made by accounting not only tho formal verification and program testing. but also the impact of many other standard V&V techniques, in a unified software reliability assessment framework. The first year of this research resulted in the statistical framework that, given the assumptions on the success of the qualitative V&V and QA procedures, significantly reduces the amount of testing needed to confidently assess reliability at so-called high and ultra-high levels (10-4 or higher). The coming years shall address the methodologies to realistically estimate the impacts of various V&V techniques to system reliability and include the impact of operational risk to reliability assessment. Combine formal correctness verification, process and product metrics, and other standard qualitative software assurance methods with statistical testing with the aim of gaining higher confidence in software reliability assessment for high-assurance applications. B) Quantify the impact of these methods on software reliability. C) Demonstrate that accounting for the effectiveness of these methods reduces the number of tests needed to attain certain confidence level. D) Quantify and justify the reliability estimate for systems developed using various methods.

Cukic, Bojan↗

Nondestructive examination of the Tropical Rainfall Measuring Mission (TRMM) reaction control subsystem (RCS) propellant tanks

This paper assesses the feasibility of using eddy current nondestructive examination to determine flaw sizes in completely assembled hydrazine propellant tanks. The study was performed by the NASA Goddard Space Flight Center for the Tropical Rainfall Measuring Mission (TRMM) project to help determine whether existing propellant tanks could meet the fracture analysis requirements of the current pressure vessel specification, MIL-STD-1522A and, therefore be used on the TRMM spacecraft. After evaluating several nondestructive test methods, eddy current testing was selected as the most promising method for determining flaw sizes on external and internal surfaces of completely assembled tanks. Tests were conducted to confirm the detection capability of the eddy current NDE, procedures were developed to inspect two candidate tanks, and the test support equipment was designed. The non-spherical tank eddy current NDE test program was terminated when the decision was made to procure new tanks for the TRMM propulsion subsystem. The information on the development phase of this test program is presented in this paper as a reference for future investigation on the subject.

Free, James M.↗

Nondestructive examination of the TRMM RCS propellant tanks

This paper assesses the feasibility of using eddy current nondestructive examination of determine flaw sizes in completely assembled hydrazine propellant tanks. The study was performed by the NASA Goddard Space Flight Center for the Tropical Rainfall Measuring Mission (TRMM) project to help determine whether existing propellant tanks could meet the fracture analysis requirements of the current pressure vessel specification, MIL-STD-1522A and, therefore be used on the TRMM spacecraft. After evaluating several nondestructive test methods, eddy current testing was selected as the most promising method for determining flaw sizes on external and internal surfaces of completely assembled tanks. Tests were conducted to confirm the detection capability of the eddy current NDE, procedures were developed to inspect two candidate tanks, and the test support equipment was designed. The non-spherical tank eddy current NDE test program was terminated when the decision was made to procure new tanks for the TRMM propulsion subsystem. The information on the development phase of this test program is presented in this paper as a reference for future investigation on the subject.

Free, James M.↗

Refinements to the Mixed-Mode Bending Test for Delamination Toughness

The mixed-mode bending (MMB) test for delamination toughness was first introduced in 1988. This simple test is a combination of the standard Mode I (opening) test and a Mode II (sliding) test. This MMB test has become widely used in the United States and around the world for mixed-mode toughness measurements. Because of the widespread use of this test method, it is being considered for standardization by ASTM Committee D30. This paper discusses several improvements to the original test method. The improvements to the MMB test procedure include an improved method for calculating toughness from the measured test quantities, a more accurate way of setting the mixed-mode ratio to be tested, and the inclusion of a new alignment criterion for improved consistency in measured values.

Reeder, James R.↗

Accelerated Testing of Polymeric Composites Using the Dynamic Mechanical Analyzer

Creep properties of IM7/K3B composite material were obtained using three accelerated test methods at elevated temperatures. Results of flexural creep tests using the dynamic mechanical analyzer (DMA) were compared with results of conventional tensile and compression creep tests. The procedures of the three test methods are described and the results are presented. Despite minor differences in the time shift factor of the creep compliance curves, the DMA results compared favorably with the results from the tensile and compressive creep tests. Some insight is given into establishing correlations between creep compliance in flexure and creep compliance in tension and compression. It is shown that with careful consideration of the limitations of flexure creep, a viable and reliable accelerated test procedure can be developed using the DMA to obtain the viscoelastic properties of composites in extreme environments.

Abdel-Magid, Becky M.↗

Radiometric Testing of Germicidal UV Products, Round 1: UV-C Towers and Whole-Room Luminaires (CALiPER Summary Report)

This summary report analyzes the independently tested performance of 13 germicidal ultraviolet (GUV) products purchased between February and July 2022. A companion full report provides additional information and discussion of the tested products, test methods, and results. The products were of three different types: • Seven portable, consumer-oriented GUV towers designed to be placed on the floor or a desk of an unoccupied room to disinfect air and surfaces. Five of these products used LED sources and two products used low-pressure mercury (LPM) sources. • One non-portable GUV whole-room luminaire designed to be installed on a ceiling to disinfect air when a room is occupied. This product used an LED source. • Five non-portable GUV troffer or high-bay style whole-room luminaires designed to be installed in or suspended from a ceiling to disinfect air and surfaces when a room is unoccupied. All five used LPM sources. Radiometric and electrical performance was evaluated for all 13 products. Photobiological safety was also assessed for two of the products because their documentation included testable claims. The test results were compared across products and to manufacturer or vendor claims. The testing identified many issues related to the accuracy of reported GUV product performance. Claims were often untestable, contradictory, ambiguous, or used incorrect units and/or terminology. And when claims were testable, they often did not match test results. For example, three products that claimed to emit UV-C emitted only UV-A. These product claim issues were more numerous with consumer-oriented tower products, but problems with accurate performance claims were found across all products. The UV-C radiant efficiency of the products varied widely, even among similar products using the same source technologies. For example, the UV-C radiant efficiency of LPM products varied by greater than a factor of three for the same product type, indicating a large potential energy savings opportunity for products that are better designed for efficiency. LED products had orders-of-magnitude lower UV-C radiant efficiency than LPM products. Several testing challenges and limitations were identified. Most significant among these is the capability to accurately test and report the performance of larger GUV products. Integrating spheres require a specialized and costly coating to test UV, and the testing laboratory for this round of products had only a 20-inch diameter hemisphere with this capability. Only 2 of the 10 UV-C emitting products could be tested in this sphere. Goniometer testing had a different size limitation in that mirrors typically used to increase goniometer test distance to the far field are not reflective of UV and therefore could not be used to increase test distance. As a result, 7 of 13 products could not be tested far field. The implication is that electronic files of UV-C intensity data typically imported into design software for designing GUV applications may not be reliable for predicting irradiance at arbitrary far-field distances. It is currently unclear if these are industry-wide testing laboratory limitations, and what solutions may exist to address them. Specifiers and buyers of GUV products will need accurate performance claims and data to safely and effectively deploy GUV technology to reduce the transmission of diseases in buildings. This CALiPER GUV Round 1 report demonstrates the significant education and training that is needed for manufacturers and vendors to accurately test and report the performance of their GUV products. Further standards and guidelines are needed to improve test methods, address testing limitations, and improve reporting of product performance. Additionally, the wide range in UV-C radiant efficiency of GUV products means there is a large energy-savings opportunity for more energy efficient GUV products.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗