Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Spectrometer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Figure-of-Merit for a Cold Coupled Moderator at the SNS Second Target Station suited for Direct Geometry Inelastic Spectrometers

The suite of moderators for the Second Target Station (STS) at the Spallation Neutron Source (SNS) in Oak Ridge is currently undergoing the planning stage at which various options and configurations are being considered. The current plans for the instrument suite include two direct geometry inelastic spectrometers, CHESS and HERTZ, which will receive beam from cold moderators and work mostly in the 1-20 meV incident energy range. CHESS will be a relatively short (wide bandwidth) instrument that is dedicated to studying small samples (∼mm3) with coarse energy resolution (2.5 – 5% of Ei). HERTZ on the other hand will be designed to achieve very good energy resolution, 1 – 3% of Ei, using a long secondary flightpath with a ∼ 4 × 4 cm2 beam on sample. In this contribution, we will discuss the implications of these design requirements for the optimal moderator pulse width, and for the repetition rate that would be best suited for the spectrometers.

Ehlers, Georg↗

Neutron powder di?raction using the ARCS chopper spectrometer at the Spallation Neutron Source

The first neutron powder di raction based atomic pair distribution functions (PDFs) are reported from the new wide angular-range chopper spectrometer ARCS at the Spallation Neutron Source at Oak Ridge National Laboratory. The spectrometer was run in white-beam mode, with no Fermi chopper. The PDF patterns of Si, Ni, and Al2O3 were refined using the PDFfit method and the results compared to data collected at the NPDF diffractometer at Los Alamos National Laboratory. The resulting fits are of high quality demonstrating that quantitatively reliable powder diffraction data can be obtained from ARCS when operated in this configuration.

Bozin, Emil↗

A PbWO 4 -based Neutral Particle Spectrometer in Hall C at 12 GeV JLab

The Neutral Particle Spectrometer is a standalone electromagnetic calorimeter capable of detecting high energy photons from, for instance, DVCS or π 0 decay with good energy and spatial resolution in a high rate environment. It can be used together with the Hall C high-momentum spectrometers for a suite of experiments with the underlying scientific objective of studying quark dynamics through exclusive and semi-inclusive reactions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Commissioning of the pair spectrometer of the GlueX experiment

The main goal of the pair spectrometer of the GlueX experiment at Jefferson Lab is to determine the photon beam flux and to measure beam polarization. Here, we present the design of the pair spectrometer and the performance results during the first commissioning runs of the GlueX experiment.

43 PARTICLE ACCELERATORS↗

Dual crystal x-ray spectrometer at 1.8 keV for high repetition-rate single-photon counting spectroscopy experiments

The recent development of high-repetition rate x-ray free electron lasers (FEL), makes it possible to perform x-ray scattering and emission spectroscopy measurements from thin foils or gasses heated to high-energy density conditions by integrating over many experimental shots. Since the expected signal may be weaker than the typical CCD readout noise over the region-of-interest, it is critical to the success of this approach to use a detector with high-energy resolution so that single x-ray photons may be isolated. We describe a dual channel x-ray spectrometer developed for the Atomic and Molecular Optics endstation at the Linac Coherent Light Source (LCLS) for x-ray spectroscopy near the K-edge of aluminum. The spectrometer is based on a pair of curved PET (002) crystals coupled to a single pnCCD detector which simultaneously measures x-ray scattering and emission in the forward and backward directions. Furthermore, the signals from single x-ray photons are accumulated permitting continuous single-shot acquisition at 120 Hz.

42 ENGINEERING↗

Improved large-energy-range magnetic electron-positron spectrometer for experiments with the Texas Petawatt Laser

We present the design, construction, and first use of a magnetic electron-positron spectrometer at the Texas Petawatt Laser facility. Here, the Global Spectrometer for Positron and Electron Characterization (GSPEC) is capable of detecting electrons and positrons over a large energy range from 3–150 MeV and has been designed to diagnose the electrons and positrons accelerated by high-intensity laser interactions with over-critical targets.

47 OTHER INSTRUMENTATION↗

Absolute calibration of the continuum x-ray spectrometer (ConSpec) at the National Ignition Facility

We illustrate the absolute calibration of the continuum x-ray spectrometer (ConSpec), designed to measure the hot-spot electron temperature of inertial confinement fusion (ICF) implosions at the National Ignition Facility (NIF). The spectrometer measures emission from photon energies of 20 to 30 keV where opacity effects in ICF implosions at the NIF are negligible and provides spatial resolution to separate the hot-spot emission from other x-ray sources, such as the gold emission from the hohlraum wall. Using a combination of x-ray ray tracing and calibration data taken using a well characterized x-ray source, we measure the dispersion, spatial resolution, and absolute sensitivity of the instrument. Finally, we present an example spectrum measured at the NIF and demonstrate the ability to measure the hot-spot electron temperature with uncertainty under 10%.

47 OTHER INSTRUMENTATION↗

Proton reconstruction with the CMS-TOTEM Precision Proton Spectrometer

The Precision Proton Spectrometer (PPS) of the CMS and TOTEM experiments collected 107.7 fb$^{-1}$ in proton-proton (pp) collisions at the LHC at 13 TeV (Run 2). This paper describes the key features of the PPS alignment and optics calibrations, the proton reconstruction procedure, as well as the detector efficiency and the performance of the PPS simulation. The reconstruction and simulation are validated using a sample of (semi)exclusive dilepton events. The performance of PPS has proven the feasibility of continuously operating a near-beam proton spectrometer at a high luminosity hadron collider.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

First full Dalitz plot measurement in neutron 𝛽 decay using the Nab spectrometer and implications for new physics

Precision measurements of observables in neutron 𝛽 decay are used to test the standard model description of the weak interaction and search for evidence of new physics. The Nab experiment at the Fundamental Neutron Physics Beamline at the Spallation Neutron Source was constructed to measure correlations in neutron decay by utilizing an asymmetric spectrometer and novel detection system to accurately reconstruct the proton momentum and electron energy for each 𝛽 decay. This work describes the detection of neutron 𝛽-decay products in the Nab spectrometer and presents the first full Dalitz plot representation of the phase space of neutron 𝛽 decay for all electrons >100 keV. In addition, new constraints are placed on a possible excited neutron state, hypothesized to explain the disagreement between the appearance and disappearance neutron lifetime techniques.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Deciphering Nb 98 β decay with the Modular Total Absorption Spectrometer at ORNL

An assessment done under the auspices of the Organization for Economic Co-operation and Developement Nuclear Energy Agency (OECD-NEA) in 2007 suggested that the β decays of many abundantly produced fission products in nuclear reactors may be incomplete. In this assessment, the fission product 98 Nb was assigned the highest priority for study by total absorption spectroscopy due to its large cumulative fission branching fraction and because the β-decay data from several experiments are discrepant. To obtain the complete β-decay feeding pattern of 98 Nb and determine the impact on the average γ energy per 98 Nb β decay and v¯e emission calculations. The complete 98 Nb β-decay feeding pattern includes ground-state to ground-state β feeding and direct β feeding to the 0 + first-excited state (both have no associated γ rays), and the ground-state to excited-state β transitions followed by γ transitions to the ground state of the daughter nucleus, 98 Mo. The complete β-decay intensities of 98 Nb were measured with the Modular Total Absorption Spectrometer at Oak Ridge National Laboratory (ORNL). Here, the 98 Nb was produced by the β decay of mass 98 fission fragments at ORNL's On-Line Test Facility (OLTF) using proton-induced fission of 238 U. We find that changes to the current ENSDF assessment of 98 Nb β-decay intensity are required. We report improved uncertainties for the β-decay feeding values and report new β feedings to high-energy levels in 98 Mo. A more complete 98 Nb β-feeding pattern with improved accuracy and precision is offered. The impacts of the measured changes to the 98 Nb β-feeding pattern on both reactor decay heat calculations and predicted detection rates of reactor v¯e are presented. The Modular Total Absorption Spectrometer measurements of 98 Nb demonstrate the importance of reexamining and remeasuring complex β-decaying fission products with total absorption spectroscopy, including nuclei very near β stability.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Coherent-Radiation Spectroscopy of Few-Femtosecond Electron Bunches Using a Middle-Infrared Prism Spectrometer

Modern, high-brightness electron beams such as those from plasma wakefield accelerators and free-electron laser linacs continue the drive to ever-shorter bunch durations. In low-charge operation ( ~ 20 pC ), bunches shorter than 10 fs are reported at the Linac Coherent Light Source (LCLS). Though suffering from a loss of phase information, spectral diagnostics remain appealing as compact, low-cost bunch duration monitors suitable for deployment in beam dynamics studies and operations instrumentation. Progress in middle-infrared (MIR) imaging has led to the development of a single-shot, MIR prism spectrometer to characterize the corresponding LCLS coherent beam radiation power spectrum for few-femtosecond scale bunch length monitoring. In this Letter, we report on the spectrometer installation as well as the temporal reconstruction of 3 to 60 fs-long LCLS electron bunch profiles using single-shot coherent transition radiation spectra.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Systematic uncertainties in the measurement of the neutron lifetime using the Lunar Prospector neutron spectrometer

The lifetime of free neutrons measured in the laboratory has a longstanding disparity of ≈9 s. A space-based technique has recently been proposed to independently measure the neutron lifetime using interactions between the galactic cosmic rays and a low atmosphere planetary body. This technique has not produced competitive results yet due to constraints of nonoptimized data that contain large systematic errors. We use data from the neutron spectrometer on-board NASA's Lunar Prospector, and study two large systematics in the measurement of neutron lifetime: the lunar subsurface temperature and the lunar surface composition. We use the HeCd and HeSn neutron spectrometer data when the spacecraft was in a highly elliptical orbit during the orbit insertion period. We report the neutron lifetime using four different models that each have different choices of surface temperature and composition. The 5° [Prettyman et al ., J. Geophys. Res.: Planets 111, 2005JE002656 (2006)] and 2° [Wilson et al., Phys. Rev. C 104, 045501 (2021)] rebinned maps result in 777.6±11.7 s and 739.6±10.8 s, respectively. For the 20° map (Prettyman et al., 2006), constant equatorial and a latitude-dependent temperature model result in 738.6±10.8 s and 767.3±11.2 s, respectively. Increasing the complexities of the models accounting for the systematic effects increase the measured lifetime. However, the reported measurements are not competitive with the laboratory results due to large unaccounted systematics resulting from nonoptimized measurements and modeling assumptions. This work serves as a study of systematic uncertainties for future neutron lifetime measurements using the space-based technique. We estimate the effect on the lifetime from the choice of temperature model to be to be 28.7 ±15.5 s, and choice of compositional map (for 20° and 5° maps) to be 10.3 ±12.2 s.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A high-throughput energy-dispersive tender X-ray spectrometer for shot-to-shot sulfur measurements

An X-ray emission spectrometer that can detect the sulfur K α emission lines with large throughput and a high energy resolution is presented. The instrument is based on a large d -spacing perfect Bragg analyzer that diffracts the sulfur K α emission at close to backscattering angles. This facilitates the application of efficient concepts routinely employed in hard X-ray spectrometers towards the tender X-ray regime. The instrument described in this work is based on an energy-dispersive von Hamos geometry that is well suited for photon-in photon-out spectroscopy at X-ray free-electron laser and synchrotron sources. Comparison of its performance with previously used instrumentation is presented through measurements using sulfur-containing species performed at the LCLS. It is shown that the overall signal intensity is increased by a factor of ∼15. Implementation of this approach in the design of a tender X-ray spectroscopy endstation for LCLS-II is also discussed.

36 MATERIALS SCIENCE↗

IRIXS Spectrograph: an ultra high-resolution spectrometer for tender RIXS

The IRIXS Spectrograph represents a new design of an ultra-high-resolution resonant inelastic X-ray scattering (RIXS) spectrometer that operates at the Ru L 3 -edge (2840 eV). First proposed in the field of hard X-rays by Shvyd'ko [(2015), Phys. Rev. A, 91, 053817], the X-ray spectrograph uses a combination of laterally graded multilayer mirrors and collimating/dispersing Ge(111) crystals optics in a novel spectral imaging approach to overcome the energy resolution limitation of a traditional Rowland-type spectrometer [Gretarsson et al. (2020), J. Synchrotron Rad. 27, 538–544]. In combination with a dispersionless nested four-bounce high-resolution monochromator design that utilizes Si(111) and Al 2 O 3 (110) crystals, an overall energy resolution better than 35 meV full width at half-maximum has been achieved at the Ru L 3 -edge, in excellent agreement with ray-tracing simulations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Use of Transition Models to Design High Performance TESs for the LCLS-II Soft X-Ray Spectrometer

We are designing an array of transition-edge sensor (TES) microcalorimeters for a soft X-ray spectrometer at the Linac Coherent Light Source at SLAC National Accelerator Laboratory to coincide with upgrades to the free electron laser facility. The complete spectrometer will have 1000 TES pixels with energy resolution of 0.5 eV full-width at half-maximum (FWHM) for incident energies below 1 keV while maintaining pulse decay-time constants shorter than 100 μs. In the past, TES pixels have often been designed for a particular scientific application via a combination of simple scaling relations and trial-and-error experimentation with device geometry. We have improved upon this process by using our understanding of transition physics to guide TES design. Using the two-fluid approximation of the phase-slip line model for TES resistance, we observe how the geometry and critical temperature of a TES will affect the shape of the transition. We have used these techniques to design sensors with a critical temperature of 55 mK. The best sensors achieve an energy resolution of 0.75 eV FWHM at 1.25 keV. Building upon this result, we show how the next generation of sensors can be designed to reach our goal of 0.5 eV resolution.

47 OTHER INSTRUMENTATION↗

The High Rigidity Spectrometer at the FRIB: Magnet Development Status

This paper presents the 2025 progress of the High Rigidity Spectrometer (HRS) project at the Facility for Rare Isotope Beams (FRIB). We report on the construction and testing of the first-article HRS-High Transmission BeamLine (HTBL) magnets. An HTBL dipole magnet has successfully completed cold testing, achieving full magnetic performance without quenching, and is now ready for field mapping at FRIBs offline test bench. HTBL quadrupole triplet coils have been fabricated and tested, with all coils reaching their design currents, some following initial training quenches. Furthermore, the preliminary design of the large-scale, large-aperture SPectrometer Section (SPS) magnets has progressed to determine the baseline of the downstream HRS-SPS subproject in 2025. This includes the introduction of novel magnet designs, such as the sweeper dipole magnet, the sector dipole magnet, and iron-free coil-dominated quadrupole magnets, representing a significant scale breakthrough and a first for FRIB.

Choi, Yoonhyuck↗

Data-Driven Optimization of Pixelated CdZnTe Spectrometers for Uranium Enrichment Assay

Here, in recent work [Vavrek et al. (2025)], we developed the performance optimization framework spectre-ml for gamma spectrometers with variable performance across many readout channels. The framework uses non-negative matrix factorization (NMF) and clustering to learn groups of similarly-performing channels and sweep through various learned channel combinations to optimize the performance tradeoff of including worse-performing channels for better total efficiency. In this work, we integrate the pyGEM uranium enrichment assay code with our spectre-ml framework, and show that the U-235 enrichment relative uncertainty can be directly used as an optimization target. We find that this optimization reduces relative uncertainties after a 30 -minute measurement by an average of 20%, as tested on six different H3D M400 CdZnTe spectrometers, which can significantly improve uranium non-destructive assay measurement times in nuclear safeguards contexts. Additionally, this work demonstrates that the spect re-ml optimization framework can accommodate arbitrary end-user spectroscopic analysis code and performance metrics, enabling future optimizations for complex Pu spectra.

Gamma-ray detection↗

Data-Driven Performance Optimization of Gamma Spectrometers With Many Channels

In gamma spectrometers with variable spectroscopic performance across many channels (e.g., many pixels or voxels), a tradeoff exists between including data from successively worse-performing readout channels and increasing efficiency. Brute-force calculation of the optimal set of included channels is exponentially infeasible as the number of channels grows, and approximate methods are required. In this work, we present a data-driven framework for attempting to find near-optimal sets of included detector channels. The framework leverages non-negative matrix factorization (NMF) to learn the behavior of gamma spectra across the detector and clusters similarly-performing detector channels together. Performance comparisons are then made between spectra with channel clusters removed, which is more feasible than brute force. The framework is general and can be applied to arbitrary, user-defined performance metrics depending on the application. We apply this framework to optimizing gamma spectra measured by H3D M400 CdZnTe (CZT) spectrometers, which exhibit variable performance across their crystal volumes. In particular, we show several examples optimizing various performance metrics for uranium and plutonium gamma spectra in non-destructive assay (NDA) for nuclear safeguards, and explore trends in performance versus parameters such as clustering algorithm type. We also compare the NMF + clustering pipeline to several non-machine-learning (ML) algorithms, including several greedy algorithms. Although, we find that the NMF + clustering pipeline tends to find the best-performing set of detector voxels, significantly improving over the unoptimized spectra, but that a greedy accumulation of spectra segmented by detector depth can, in some cases, give similar performance improvements in much less computation time.

Energy resolution↗