Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Spares”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

SU-F-T-447: The Impact of Treatment Planning Methods On RapidPlan Modeling for Rectum Cancer

Purpose: To investigate the dose volume histogram (DVH) prediction varieties based on intensity modulate radiotherapy (IMRT) plan or volume arc modulate radiotherapy (VMAT) plan models on the RapidPlan. Methods: Two DVH prediction models were generated in this study, including an IMRT model trained from 83 IMRT rectum plans and a VMAT model trained from 60 VMAT rectum plans. In the internal validation, 20 plans from each training database were selected to verify the clinical feasibility of the model. Then, 10 IMRT plans (PIMRT-by-IMRT-model) generated from IMRT model and 10 IMRT plans generated from VMAT model (PIMRT-by-VMAT-model) were compared on the dose to organs at risk (OAR), which included bladder, left and right femoral heads. The similar comparison was also performed on the VMAT plans generated from IMRT model (PVMAT-by-IMRT-model) and VMAT plans generated from VMAT (PVMAT-by-VMAT-model) model. Results: For the internal validation, all plans from IMRT or VMAT model shows significantly improvement on OAR sparing compared with the corresponded clinical ones. Compared to the PIMRT-by-VMAT-model, the PIMRT-by-IMRT-model has a reduction of 6.90±3.87%(p<0.001) on V40 6.63±3.62%(p<0.001) on V45 and 4.74±2.26%(p<0.001) on V50 in bladder; and a mean dose reduction of 2.12±1.75Gy(p=0.004) and 2.84±1.53Gy(p<0.001) in right and left femoral head, respectively. There was no significant difference on OAR sparing between PVMAT-by-IMRT-model and PVMAT-by-VMAT-model. Conclusion: The IMRT model for the rectal cancer in the RapidPlan can be applied to for VMAT planning. However, the VMAT model is not suggested to use in the IMRT planning. Cautions should be taken that the planning model based on some technique may not feasible to other planning techniques.

60 APPLIED LIFE SCIENCES↗

SU-F-T-515: Increased Skin Dose in Supine Craniospinal Irradiation Due to Carbon Fiber Couch and Vacuum Bag Immobilization Device

Purpose: To measure the surface dose for supine craniospinal irradiation employing posterior beams, treating through an imaging couch and BlueBag immobilization device. Methods: The percentage depth dose (PDD) in the buildup region of a clinical 6 MV photon beam was measured using an Advanced Markus parallel plate ionization chamber in a solid water phantom. The PDD from a 10×10 cm{sup 2} anterior beam was measured at 100 cm SSD, simulating a traditional prone craniospinal technique. The measurements were compared to commissioning and treatment planning system data. The PDD was also measured in a posterior setup with the phantom surface laying directly on the Brainlab carbon fiber imaging couch, with the phantom surface 100 cm from the source, simulating a supine craniospinal setup. The posterior measurements were repeated with a BlueBag vacuum immobilization device between the couch and phantom, with thicknesses of 1.7 cm and 5 cm. The PDD from a 10×10 cm{sup 2} field and a typical 6×30 cm{sup 2} craniospinal field were also compared. The PDDs were normalized at 5 cm to reflect typical craniospinal prescription dose normalization. Results: The measured PDD curve from the anterior setup agreed well with commissioning and treatment planning data, with surface doses of 19.9%, 28.8% and 27.7%, respectively. The surface doses of the 10×10 cm{sup 2} and 6×30 cm{sup 2} fields delivered through the imaging couch were both 122.4%. The supine setup yielded surface doses of 122.4%, 121.6%, and 119.6% for the couch only, 1.7 cm bag, and 5 cm bag setups, respectively. Conclusion: Delivering craniospinal irradiation through a carbon fiber couch removes the majority of skin sparing. The addition of a vacuum bag immobilization device restores some skin sparing, but the magnitude of this effect is negligible.

60 APPLIED LIFE SCIENCES↗

SU-F-T-611: Critical Analysis and Efficacy of Linac Based (Beam Modulator) and Cyberknife Treatment Plans for Acoustic Neuroma/schwannoma

Purpose: To study the critical analysis and efficacy of Linac and Cyberknife (CK) treatment plans for acoustic neuroma/schwannoma. Methods: Twelve of acoustic neuroma/schwannoma patients were taken for these study that. Treatment plans were generated in Multiplan treatment planning system (TPS) for CK using 5,7.5 and 10mm diameter collimators. Target volumes were in the range of 0.280 cc to 9.256 cc. Prescription dose (Rx) ranges from 1150cGy to 1950cGy delivered over 1 to 3 Fractions. For same patients stereotactic Volumetric modulated arc plans were generated using Elekta Linac with MLC thickness of 4mm in Monaco TPS. Appropriate calculation algorithms and grid size were used with same Rx and organ at risk (OAR) constrains for both Linac and CK plans. Treatment plans were developed to achieve at least 95% of the target volume to receive the Rx. The dosimetric indices such as conformity index (CI), coverage, OAR dose and volume receiving 50% of Rx (V50%) were used to evaluate the plans. Results: Target volumes ranges from 0.280 cc to 3.5cc shows the CI of 1.16±0.109 and 1.53±0.360 for cyberknife and Linac plans respectively. For small volume targets, the OARs were well spared in CK plans. There are no significant differences in CI and OAR doses were observed between CK and Linac plans that have the target volume >3.5 cc. Perhaps the V50% were lesser in CK plans, and found to be 12.8± 8.4 and 22.8 ± 15.0 for CK and Linac respectively. Conclusion: The analysis shows the importance of collimator size for small volume targets. The target volumes >3.5 cc can be treated in Linac as comparable with CK. For targets <3.5cc CK plans showed superior plan quality with better CI and OAR sparing than the Linac based plans. Further studies may require evaluating the clinical advantage of CK robotic system.

60 APPLIED LIFE SCIENCES↗

SU-F-T-618: Evaluation of a Mono-Isocentric Treatment Planning Software for Stereotactic Radiosurgery of Multiple Brain Metastases

Purpose: To evaluate planning performance of an automated treatment planning software (BrainLAB; Elements) for stereotactic radiosurgery (SRS) of multiple brain metastases. Methods: Brainlab’s Multiple Metastases Elements (MME) uses single isocentric technique to treat up to 10 cranial planning target volumes (PTVs). The planning algorithm of the MME accounts for multiple PTVs overlapping with one another on the beam eyes view (BEV) and automatically selects a subset of all overlapping PTVs on each arc for sparing normal tissues in the brain. The algorithm also optimizes collimator angles, margins between multi-leaf collimators (MLCs) and PTVs, as well as monitor units (MUs) using minimization of conformity index (CI) for all targets. Planning performance was evaluated by comparing the MME-calculated treatment plan parameters with the same parameters calculated with the Volumetric Modulated Arc Therapy (VMAT) optimization on Varian’s Eclipse platform. Results: Figures 1 to 3 compare several treatment plan outcomes calculated between the MME and VMAT for 5 clinical multi-targets SRS patient plans. Prescribed target dose was volume-dependent and defined based on the RTOG recommendation. For a total number of 18 PTV’s, mean values for the CI, PITV, and GI were comparable between the MME and VMAT within one standard deviation (σ). However, MME-calculated MDPD was larger than the same VMAT-calculated parameter. While both techniques delivered similar maximum point doses to the critical cranial structures and total MU’s for the 5 patient plans, the MME required less treatment planning time by an order of magnitude compared to VMAT. Conclusion: The MME and VMAT produce similar plan qualities in terms of MUs, target dose conformation, and OAR dose sparing. While the selective use of PTVs for arc-optimization with the MME reduces significantly the total planning time in comparison to VMAT, the target dose homogeneity was also compromised due to its simplified inverse planning algorithm used.

60 APPLIED LIFE SCIENCES↗

SU-F-T-646: SBRT Lung: Moving Beyond the 3D Conformal Paradigm with An Elekta VersaHD Accelerator

Purpose: To develop a volumetric modulated arc therapy (VMAT) planning and delivery methodology for lung stereotactic body radiation therapy (SBRT) that addresses the unique geometric challenges presented when using an Elekta VersaHD linear accelerator. Methods: The Elekta VersaHD imaging panels are fixed at 160cm SID when deployed, limiting the ability to perform non-coplanar treatments due to collisions with the treatment table. The panels can be folded in a stored position for non-coplanar treatments, but in this configuration, longitudinal table travel is restricted by the space required for the folded panels. To overcome these design features, a non-coplanar VMAT technique was designed and evaluated for 6 patients that uses a superiorly placed isocenter near the apex of the lung. A coplanar VMAT technique with isocenter placement within the target was also assessed for each patient. Non-coplanar plans included three arcs, totalling 340° of arc angle, while coplanar plans included two arcs, totalling 280° of arc angle. Each technique avoided the contralateral lung and major overlap on patient skin. Corresponding 3DCRT plans were used as a baseline for each patient in evaluating VMAT plans. Results: Coplanar and noncoplanar VMAT plans yielded a high dose conformity index (CI) improvement of 6% and low dose CI improvements of 9% and 11%, respectively, over corresponding 3DCRT plans. While both VMAT techniques provided greater skin sparing compared to 3DCRT, the non-coplanar technique offered an improvement of 20% over the coplanar approach. Treatment time with for VMAT was ∼2.5 minutes compared to ∼10 minutes for 3DCRT. Conclusion: Two VMAT techniques were developed for lung SBRT that account for machine design limitations and provide greater dose conformity and normal tissue sparing than 3DCRT plans. The non-coplanar VMAT plans showed a marginal improvement over coplanar VMAT plans and may not warrant the additional complexity.

60 APPLIED LIFE SCIENCES↗

SU-G-TeP3-01: A New Approach for Calculating Variable Relative Biological Effectiveness in IMPT Optimization

Purpose: To investigate the impact of a new approach for calculating relative biological effectiveness (RBE) in intensity-modulated proton therapy (IMPT) optimization on RBE-weighted dose distributions. This approach includes the nonlinear RBE for the high linear energy transfer (LET) region, which was revealed by recent experiments at our institution. In addition, this approach utilizes RBE data as a function of LET without using dose-averaged LET in calculating RBE values. Methods: We used a two-piece function for calculating RBE from LET. Within the Bragg peak, RBE is linearly correlated to LET. Beyond the Bragg peak, we use a nonlinear (quadratic) RBE function of LET based on our experimental. The IMPT optimization was devised to incorporate variable RBE by maximizing biological effect (based on the Linear Quadratic model) in tumor and minimizing biological effect in normal tissues. Three glioblastoma patients were retrospectively selected from our institution in this study. For each patient, three optimized IMPT plans were created based on three RBE resolutions, i.e., fixed RBE of 1.1 (RBE-1.1), variable RBE based on linear RBE and LET relationship (RBE-L), and variable RBE based on linear and quadratic relationship (RBE-LQ). The RBE weighted dose distributions of each optimized plan were evaluated in terms of different RBE values, i.e., RBE-1.1, RBE-L and RBE-LQ. Results: The RBE weighted doses recalculated from RBE-1.1 based optimized plans demonstrated an increasing pattern from using RBE-1.1, RBE-L to RBE-LQ consistently for all three patients. The variable RBE (RBE-L and RBE-LQ) weighted dose distributions recalculated from RBE-L and RBE-LQ based optimization were more homogenous within the targets and better spared in the critical structures than the ones recalculated from RBE-1.1 based optimization. Conclusion: We implemented a new approach for RBE calculation and optimization and demonstrated potential benefits of improving tumor coverage and normal sparing in IMPT planning.

60 APPLIED LIFE SCIENCES↗

SU-G-TeP4-14: Quality Control of Treatment Planning Using Knowledge-Based Planning Across a System of Radiation Oncology Practices

Purpose: There is potentially a wide variation in plan quality for a certain disease site, even for clinics located in the same system of hospitals. We have used a prostate-specific knowledge-based planning (KBP) model as a quality control tool to investigate the variation in prostate treatment planning across a network of affiliated radiation oncology departments. Methods: A previously created KBP model was applied to 10 patients each from 4 community-based clinics (Clinics A, B, C, and D). The KBP model was developed using RapidPlan (Eclipse v13.5, Varian Medical Systems) from 60 prostate/prostate bed IMRT plans that were originally planned using an in-house treatment planning system at the central institution of the community-based clinics. The dosimetric plan quality (target coverage and normal-tissue sparing) of each model-generated plan was compared to the respective clinically-used plan. Each community-based clinic utilized the same planning goals to develop the clinically-used plans that were used at the main institution. Results: Across all 4 clinics, the model-generated plans decreased the mean dose to the rectum by varying amounts (on average, 12.5, 2.6, 4.5, and 2.7 Gy for Clinics A, B, C, and D, respectively). The mean dose to the bladder also decreased with the model-generated plans (5.4, 2.3, 3.0, and 4.1 Gy, respectively). The KBP model also identified that target coverage (D95%) improvements were possible for for Clinics A, B, and D (0.12, 1.65, and 2.75%) while target coverage decreased by 0.72% for Clinic C, demonstrating potentially different trade-offs made in clinical plans at different institutions. Conclusion: Quality control of dosimetric plan quality across a system of radiation oncology practices is possible with knowledge-based planning. By using a quality KBP model, smaller community-based clinics can potentially identify the areas of their treatment plans that may be improved, whether it be in normal-tissue sparing or improved target coverage. M. Matuszak has research funding for KBP from Varian Medical Systems.

60 APPLIED LIFE SCIENCES↗

MO-FG-BRA-07: Intrafractional Motion Effect Can Be Minimized in Tomotherapy Stereotactic Body Radiotherapy (SBRT)

Purpose: Tomotherapy has unique challenges in handling intrafractional motion compared to conventional LINAC. In this study, we analyzed the impact of intrafractional motion on cumulative dosimetry using actual patient motion data and investigated real time jaw/MLC compensation approaches to minimize the motion-induced dose discrepancy in Tomotherapy SBRT treatment. Methods: Intrafractional motion data recorded in two CyberKnife lung treatment cases through fiducial tracking and two LINAC prostate cases through Calypso tracking were used in this study. For each treatment site, one representative case has an average motion (6mm) and one has a large motion (10mm for lung and 15mm for prostate). The cases were re-planned on Tomotherapy for SBRT. Each case was planned with 3 different jaw settings: 1cm static, 2.5cm dynamic, and 5cm dynamic. 4D dose accumulation software was developed to compute dose with the recorded motions and theoretically compensate motions by modifying original jaw and MLC to track the trajectory of the tumor. Results: PTV coverage in Tomotherapy SBRT for patients with intrafractional motion depends on motion type, amplitude and plan settings. For the prostate patient with large motion, PTV coverage changed from 97.2% (motion-free) to 47.1% (target motion-included), 96.6% to 58.5% and 96.3% to 97.8% for the 1cm static jaw, 2.5cm dynamic jaw and 5cm dynamic jaw setting, respectively. For the lung patient with large motion, PTV coverage discrepancies showed a similar trend of change. When the jaw and MLC compensation program was engaged, the motion compromised PTV coverage was recovered back to >95% for all cases and plans. All organs at risk (OAR) were spared with < 5% increase from original motion-free plans. Conclusion: Tomotherapy SBRT is less motion-impacted when 5cm dynamic jaw is used. Once the motion pattern is known, the jaw and MLC compensation program can largely minimize the compromised target coverage and OAR sparing.

60 APPLIED LIFE SCIENCES↗

TU-H-CAMPUS-TeP1-01: Variable-Beam Fractionation for SAbR

Purpose: In current conventionally-fractionated as well as hypofractionated 3D conformal radiotherapy (CRT), the same beam arrangement is employed from fraction to fraction. We challenge this notion and postulate that by varying the beam arrangement between fractions we can achieve greater sparing of organs at risk (OARs) while maintaining PTV coverage. We use an inverse planning strategy using a swarm intelligence-based global optimization algorithm to exploit the additional degree of freedom represented by inter-fractional variation in beam angles. Methods: To evaluate our variable-beam fractionation (VBF) method, a 10-beam ITV-based conformal stereotactic ablative radiotherapy (CRT-SAbR) plan was optimized. In the clinical plan, 54 Gy was delivered to a 41cc lung tumor over 3 fractions. In VBF, each original clinically-assigned beam was multiplied to a bundle of n α-degree-spaced beams, n being number of fractions. Selection of α was a compromise between retaining similar tumor irradiation and separating inline OAR sub-regions. We optimized the beam fluence weights setting an upper limit for beam delivery duration (and implicitly, monitor units) along with clinical organ-based dose-volume constraints. Zero weights were allowed so that the optimization algorithm could remove unnecessary beams. All fractions in final plan had to deliver identical monitor units (MU) while satisfying a soft constraint on having no more than one beam from every n-beam bundle in each fraction. α was 10 degrees and the dose rate was 600 MU/min. Results: The VBF plan achieved significantly superior OAR sparing compared to the clinical internal target volume (ITV)-based plan. Setting maximum beam delivery duration to 13 seconds (well within breath-hold range), Esophagus Dmax, Heart Dmax, Spinal cord Dmax and Lung V13 were improved by 25%, 81%, 0% and 27%, respectively. Conclusion: We investigated a simple approach to inter-fractional VBF planning and demonstrated its potential in reducing dose to OARs. This work was partially supported through research funding from National Institutes of Health (R01CA169102) and Varian Medical Systems, Palo Alto, CA, USA.

60 APPLIED LIFE SCIENCES↗

TH-AB-BRA-08: Simulated Tumor Tracking in An MRI Linac for Lung Tumor Lesions Using the Monaco Treatment Planning System

Purpose: To simulate tumor tracking in an Elekta MRI-linac (MRL) and to compare this tracking method with our current ITV approach in terms of OAR sparing for lung cancer patients. Methods: Five SABR-NSCLC patients with central lung tumors were selected for reasons of potential enhancement of tumor-tissue delineation using MRI. The Monaco TPS was used to compare the current clinical ITV approach to a simulated, novel tracking method which used a 7MV MRL beam in the presence of an orthogonal 1.5 T magnetic field (4D-MRL method). In the simulated tracking scenario, achieved using the virtual couch shift (VCS), the PTV was defined using an isotropic 5mm margin applied to the GTV of each phase, as acquired from an 8-phase amplitude-binned 4DCT. These VCS plans were optimized and weighted on each phase. The dose weighting was performed using the patient-specific breathing traces. The doses were accumulated on the inhale phase. The two methods were compared by assessing the OAR DVHs. Results: The 4D-MRL method resulted in a reduced target volume (by an average of 29% over all patients). The benefits of using an MRL tracking system depended on the tumor motion amplitude and the relative OAR motion (ROM) to the target. The reduction in mean doses to parallel organs was up to 3 Gy for the heart and 2.1 Gy for the lung. The reductions in maximum doses to serial organs were up to 9.4 Gy, 5.6 Gy, and 8.7 Gy for the esophagus, spinal cord, and the trachea, respectively. Serial organs benefited from MRL tracking when the ROM was ≥ 0.3 cm despite small tumor motion amplitude in some cases. Conclusions: This work demonstrated the potential benefit for an MRL tracking system to spare OARs in SABR-NSCLC patients with central tumors. The benefits are embodied in the target volume reduction. This project was made possible with the financial support of Elekta.

60 APPLIED LIFE SCIENCES↗

TH-EF-BRB-03: Significant Cord and Esophagus Dose Reduction by 4π Non-Coplanar Spine Stereotactic Body Radiation Therapy and Stereotactic Radiosurgery

Purpose: To demonstrate significant organ-at-risk (OAR) sparing achievable with 4π non-coplanar radiotherapy on spine SBRT and SRS patients. Methods: Twenty-five stereotactic spine cases previously treated with VMAT (n = 23) or IMRT (n = 2) were included in this study. A computer-aided-design model of a Linac with a 3D-scanned human surface was utilized to determine the feasible beam space throughout the 4π steradian and beam specific source-to-target-distances (STD) required for collision avoidance. 4π radiotherapy plans integrating beam orientation and fluence map optimization were then created using a column-generation algorithm. Twenty optimal beams were selected for each case. To evaluate the tradeoff between dosimetric benefit and treatment complexity, 4π plans including only isocentrically deliverable beams were also created. Beam angles of all standard and isocentric 4π plans were imported into Eclipse to recalculate the dose using the same calculation engine as the clinical plans for unbiased comparison. OAR and PTV dose statistics for the clinical, standard-4π, and isocentric-4π plans were compared. Results: Comparing standard-4π to clinical plans, particularly significant average percent reduction in the [mean, maximum] dose of the cord and esophagus of [41%, 21.7%], and [38.7%, 36.4%] was observed, along with global decrease in all other OAR dose statistics. The average cord volume receiving more than 50% prescription dose was substantially decreased by 76%. In addition, improved PTV coverage was demonstrated with a maximum dose reduction of 0.93% and 1.66% increase in homogeneity index (D95/D5). All isocentric-4π plans achieved dosimetric performance equivalent to that of the standard-4π plans with higher delivery complexity. Conclusion: 4π radiotherapy significantly improves stereotactic spine treatment dosimetry. With the substantial OAR dose sparing, PTV dose escalation is considerably safer. Isocentric-4π is sufficient to achieve the dosimetric gain. The successful implementation of 4π using an FDA approved planning system paves the way for a prospective clinical trial. Varian Medical Systems, NIH R43CA183390 and R01CA188300, NSF graduate research fellowship DGE-1144087.

60 APPLIED LIFE SCIENCES↗

Sci-Fri PM: Radiation Therapy, Planning, Imaging, and Special Techniques - 07: Transitioning from extended-distance total body irradiation to optimized VMAT total marrow irradiation

Purpose: TMI targets only the bone marrow, with the intent of sparing normal tissues. The NSCC has recently implemented a TMI protocol which includes VMAT fields to treat the bone marrow from head to mid-thigh and extended SSD POP fields to treat the lower legs. This work describes the commissioning and initial clinical results of the first reported VMAT TMI treatments in Canada. Methods: Detailed CT simulation, imaging, planning and treatment procedures were developed by a multi-disciplinary team. Patients have 1 cm of bolus over the lower legs and 0.5 cm of bolus around the lower arms. The PTV includes all bone, except mandible, facial bones and hands, with the objective of V(12 Gy) > 90%. Detailed analysis of the influence of field overlap was performed to determine optimal field placement and image-guidance tolerances. Results: PTV coverage was achieved for all cases as V(12 Gy) ranged from 90.4–96.3%. The minimum dose to the PTV, D(99%), ranged from 91.4–97.87% and V(90%Rx=10.8 Gy) ranged from 99.1–100.0%. The lungs, liver and heart had an average D{sub mean} of (7.8±0.3)Gy/(65±2)%, (7.6±0.7)Gy/(63±5)%, and (6.8±0.4)Gy/(56±4)% respectively. Conclusions: Commissioning required input and collaboration from all team members. Transitioning from TBI to TMI requires additional time for contouring, treatment planning, QA, and treatment. Patient benefit can however be seen in the quality of OAR sparing.

60 APPLIED LIFE SCIENCES↗

Complete Genome Sequence and Updated Annotation of Desulfovibrio alaskensis G20

Desulfovibrio alaskensis G20 (formerly desulfuricans G20) is a Gram-negative mesophilic sulfate-reducing bacterium (SRB), known to corrode ferrous metals and to reduce toxic radionuclides and metals such as uranium and chromium to sparingly soluble and less toxic forms. We present the 3.7 Mb genome sequence to provide insights into its physiology.

59 BASIC BIOLOGICAL SCIENCES↗

The Solubility of Tugarinovite (MoO 2 ) in H 2 O at Elevated Temperatures and Pressures

The solubility of tugarinovite (MoO 2 ) in pure water was investigated at temperatures between 400 and 800°C and at pressures ranging between 95 and 480 MPa by using in situ synchrotron X-ray fluorescence (SXRF) to separately analyze high temperature aqueous solutions in a hydrothermal diamond anvil cell (HDAC). The concentration of molybdenum in the fluid at 400 and 500°C was below detection; however, at temperatures between 600 and 800°C, the solubility of tugarinovite increased with increasing temperature by two orders of magnitude. The molybdenum concentration at 600°C and 800°C is 44 ppm and 658 ppm, respectively. The results complement the data of Kudrin (1985) and provide the first measurement of MoO 2 solubility at pressure and temperature conditions comparable to intrusion-related Mo deposit formation. The data are also relevant to the study of water chemistry and corrosion product transport in supercritical-water-cooled reactors, where Mo-bearing steel alloys interact with aqueous solutions at temperatures greater than 600°C. The application of in situ SXRF to solubility measurements of sparingly soluble minerals is recommended because it circumvents analytical uncertainties inherent in determinations obtained by quenching and weight loss measurements.

Saha, Pritam↗

A Comparison of Patient-Reported Outcomes After Breast-Conserving Surgery and Mastectomy with Implant Breast Reconstruction

Background: Many factors influence decisions regarding choice of breast-conserving surgery (BCS) versus mastectomy with reconstruction for early invasive breast cancer. The purpose of this study was to compare patient satisfaction following BCS and mastectomy with implant reconstruction (M-iR) utilizing the BREAST-Q patient-reported outcome measure. Methods: Women with stage I or II breast cancer undergoing BCS or M-iR who completed a BREAST-Q from 2010 to 2016 were identified by retrospective review of a prospective database. Baseline characteristics were compared, and linear mixed models were used to analyze associations with BREAST-Q scores over time. Results: Our study group was composed of 3233 women; 2026 (63%) had BCS, 123 (3.8%) had nipple-sparing mastectomy, and 1084 (34%) had skin-sparing or total mastectomy. Median time from surgery to BREAST-Q was 205 days for BCS and 639 days for M-iR (p < 0.001). Regardless of type of surgery, breast satisfaction scores decreased significantly over time (p < 0.001), whereas psychosocial (p = 0.001) and sexual (p = 0.004) well-being scores increased significantly over time. BCS was associated with significantly higher scores over time compared with M-iR across all subscales (all p < 0.001). Radiation was significantly associated with decreased scores over time across all subscales (all p < 0.05). Conclusions: Breast satisfaction and quality-of-life scores were higher for BCS compared with M-iR in early-stage invasive breast cancer. These findings may help in counseling women who have a choice for surgical treatment. Breast satisfaction scores decreased over time in all women, highlighting the need for further evaluation with longer follow-up.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Update on the Feasibility and Progress on Robotic Breast Surgery

Background: Robotic nipple-sparing mastectomy (RNSM) may allow for more precise anatomic dissection and improved cosmetic outcomes over conventional open nipple-sparing mastectomy; however, data regarding the feasibility and safety of the procedure are limited. Objective: The aim of this study was to present and discuss perioperative surgical outcomes and early oncologic follow-up data on consecutive patients undergoing RNSM from June 2014 to January 2019. Methods: Patients underwent RNSM and immediate robotic breast reconstruction through an axillary incision at a single institution. Perioperative data, complications at 3 months postoperatively, pathological data, and adjuvant therapies were recorded. Local recurrence-free, disease-free, and overall survival were analyzed. Results: Overall, 73 women underwent 94 RNSM procedures. Indications were invasive breast cancer in 39 patients, ductal carcinoma in situ in 17 patients, and BRCA mutation in 17 patients. Mean surgery time was 3 h and 32 min. One-step reconstruction with implant occurred in 89.4% of procedures. The rate of complications requiring reoperation was 4.3%, and the rate of flap or nipple necrosis was 1.1%. Median follow-up was 19 months (range 3.1–44.8). No local recurrences occurred. Overall survival at 12, 24, or 60 months was 98% (95% confidence interval 86–100%). Conclusion: We observed a low complication rate in 94 consecutive RNSM procedures, demonstrating the procedure is technically feasible and safe. We found no early local failures at 19 months follow-up. Long-term follow-up is needed to confirm oncologic safety. Future clinical trials to study the advantages and disadvantages of RNSM are warranted.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quantifying Uncertainty of Deep Reinforcement Learning Based Decision Making for Operations and Maintenance of Nuclear Power Plant

This paper summarizes research that integrates condition monitoring and prognostics with decision making for nuclear power plant operations and maintenance. As part of this research, we have developed an online asset management tool to help reduce life-cycle maintenance and repair costs. Using the latest advancements in condition monitoring, supply chain analytics, and deep reinforcement learning, we have created a predictive maintenance tool that can optimize the maintenance and spare-part management of a repairable nuclear system. To demonstrate these methods, preliminary studies were conducted on a simple, representative maintenance system undergoing a stochastic degradation process that requires repairs or replacement to continue operation. Through Monte Carlo simulations, we were able to reduce maintenance spending by approximately 50% compared to optimized, time-based maintenance strategies. Not only does the decision maker reduce the average life-cycle costs, it also minimizes the chance of high cost scenarios, lowering the variance of the expected cost distributions, and reducing overall financial risk. Furthermore, this work also studies the ability of the decision maker to handle various levels of noise from observation uncertainty. By introducing uncertainty into the decision-making process, we have quantified the robustness and resiliency of the decision maker, as well as identified necessary levels of observability to demonstrate cost effectiveness.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Impact Disdrometers Instrument Handbook

To improve the quantitative description of precipitation processes in climate models, the U.S. Department of Energy’s Atmospheric Radiation Measurement (ARM) Climate Research Facility has been collecting observations of the drop size spectra of rain events since early in 2006. Impact disdrometers were the initial choice due to their reliability, ease of maintenance, and relatively low cost. Each of the two units deployed was accompanied by a nearby tipping bucket. In 2010, the tipping buckets were replaced by weighing buckets rain gauges. Five video disdrometers were subsequently purchased and are described in ARM’s VDIS Handbook.1 As of April 2011, three of the weighing bucket instruments were deployed, one was to travel with the second ARM Mobile Facility, and the fifth was a spare. Two of the video disdrometers were deployed, a third was to be deployed later in the spring of 2011, one was to travel with the second ARM Mobile Facility, and the last was a spare. Detailed descriptions of impact disdrometers and their datastreams are provided in this document.

54 ENVIRONMENTAL SCIENCES↗