Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Source identification”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Sparse and Random Sampling Techniques for High-Resolution, Full-Field, BSS-Based Structural Dynamics Identification from Video

Video-based techniques for identification of structural dynamics have the advantage that they are very inexpensive to deploy compared to conventional accelerometer or strain gauge techniques. When structural dynamics from video is accomplished using full-field, high-resolution analysis techniques utilizing algorithms on the pixel time series such as principal components analysis and solutions to blind source separation the added benefit of high-resolution, full-field modal identification is achieved. An important property of video of vibrating structures is that it is particularly sparse. Typically video of vibrating structures has a dimensionality consisting of many thousands or even millions of pixels and hundreds to thousands of frames. However the motion of the vibrating structure can be described using only a few mode shapes and their associated time series. As a result, emerging techniques for sparse and random sampling such as compressive sensing should be applicable to performing modal identification on video. This work presents how full-field, high-resolution, structural dynamics identification frameworks can be coupled with compressive sampling. The techniques described in this work are demonstrated to be able to recover mode shapes from experimental video of vibrating structures when 70% to 90% of the frames from a video captured in the conventional manner are removed.

47 OTHER INSTRUMENTATION↗

Electronics System for the GammaTracker Handheld CdZnTe Detector

We are currently developing a handheld radioisotope identifier containing eighteen position-sensitive CdZnTe crystals. In addition to isotope identification, the device performs basic Compton imaging to determine the location of suspected sources. This paper gives an overview of the electronics system we have designed for this instrument. We use specialized application-specific integrated circuits to preprocess the outputs of each CdZnTe crystal. A low-power microprocessor running Windows CE drives the user interface and implements the isotope identification and directionality computations. Finally, we use a field-programmable gate array to perform the computationally intensive imaging tasks in real time.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

THE SPITZER SURVEY OF INTERSTELLAR CLOUDS IN THE GOULD BELT. II. THE CEPHEUS FLARE OBSERVED WITH IRAC AND MIPS

We present Spitzer Infrared Array Camera (IRAC; {approx}2 deg{sup 2}) and Multiband Imaging Photometer for Spitzer (MIPS; {approx}8 deg{sup 2}) observations of the Cepheus Flare, which is associated with the Gould Belt, at an approximate distance of {approx}300 pc. Around 6500 sources are detected in all four IRAC bands, of which {approx}900 have MIPS 24 {mu}m detections. We identify 133 young stellar object (YSO) candidates using color-magnitude diagram techniques, and a large number of the YSO candidates are associated with the NGC 7023 reflection nebula. Cross-identifications were made with the Guide Star Catalog II and the IRAS Faint Source Catalog, and spectral energy distributions (SEDs) were constructed. SED modeling was conducted to estimate the degree of infrared excess. It was found that a large majority of disks were optically thick accreting disks, suggesting that there has been little disk evolution in these sources. Nearest-neighbor clustering analysis identified four small protostellar groups (L1228, L1228N, L1251A, and L1251B) with 5-15 members each and the larger NGC 7023 association with 32 YSO members. The star-formation efficiency for cores with clusters of protostars and for those without clusters was found to be {approx}8% and {approx}1%, respectively. The cores L1155, L1241, and L1247 are confirmed to be starless down to our luminosity limit of L {sub bol} = 0.06 L {sub sun}.

79 ASTRONOMY AND ASTROPHYSICS↗

Around 200 new X-ray binary IDs from 13 YR of Chandra observations of the M31 center

We have created 0.3-10 keV, 13 yr, unabsorbed luminosity lightcurves for 528 X-ray sources in the central 20' of M31. We have 174 Chandra observations spaced at ∼1 month intervals due to our transient monitoring program, deeper observations of the M31 nucleus, and some public data from other surveys. We created 0.5-4.5 keV structure functions (SFs) for each source for comparison with the ensemble SF of active galactic nuclei (AGN). We find 220 X-ray sources with luminosities ≳10{sup 35} erg s{sup –1} that have SFs with significantly more variability than the ensemble AGN SF, and which are likely X-ray binaries (XBs). A further 30 X-ray sources were identified as XBs using other methods. We therefore have 250 probable XBs in total, including ∼200 new identifications. This result represents great progress over the ∼50 XBs and ∼40 XB candidates previously identified out of the ∼2000 X-ray sources within the D {sub 25} region of M31; it also demonstrates the power of SF analysis for identifying XBs in external galaxies. We also identify a new transient black hole candidate, associated with the M31 globular cluster B128.

79 ASTRONOMY AND ASTROPHYSICS↗

A search for the lenses in the Herschel Bright Sources (HerBS) sample

ABSTRACT Verifying that sub-mm galaxies are gravitationally lensed requires time-expensive observations with oversubscribed high-resolution observatories. Here, we aim to strengthen the evidence of gravitational lensing within the Herschel Bright Sources (HerBS) by cross-comparing their positions to optical (SDSS) and near-infrared (VIKING) surveys, in order to search for the foreground lensing galaxy candidates. Resolved observations of the brightest HerBS sources have already shown that most are lensed, and a galaxy evolution model predicts that ∼76 per cent of the total HerBS sources are lensed, although with the SDSS survey we are only able to identify the likely foreground lenses for 25 per cent of the sources. With the near-infrared VIKING survey, however, we are able to identify the likely foreground lenses for 57 per cent of the sources, and we estimate that 82 per cent of the HerBS sources have lenses on the VIKING images even if we cannot identify the lens in every case. We find that the angular offsets between lens and Herschel source are larger than that expected if the lensing is done by individual galaxies. We also find that the fraction of HerBS sources that are lensed falls with decreasing 500-micron flux density, which is expected from the galaxy evolution model. Finally, we apply our statistical VIKING cross-identification to the entire Herschel-ATLAS catalogue, where we also find that the number of lensed sources falls with decreasing 500-micron flux density.

Bakx, Tom J. L. C.↗

VLBI OBSERVATIONS OF 10 COMPACT SYMMETRIC OBJECT CANDIDATES: EXPANSION VELOCITIES OF HOT SPOTS

Observations of 10 Compact Symmetric Object (CSO) candidates have been made with the Very Long Baseline Array (VLBA) at 8.4 GHz in 2005 and with a combined Chinese and European Very Long Baseline Interferometry (VLBI) array at 8.4 GHz in 2009. The 2009 observations incorporate for the first time the two new Chinese telescopes at Miyun and Kunming for international astrophysical observations. The observational data, in combination with archival VLBA data from previous epochs, have been used to derive the proper motions of the VLBI components. Because of the long time baseline of {approx}16 years of the VLBI data sets, the expansion velocities of the hot spots can be measured at an accuracy as high as {approx}1.3 {mu}as yr{sup -1}. Six of the ten sources are identified as CSOs with a typical double or triple morphology on the basis of both spectral index maps and their mirror symmetry of proper motions of the terminal hot spots. The compact double source J1324+4048 is also identified as a CSO candidate. Among the three remaining sources, J1756+5748 and J2312+3847 are identified as core-jet sources with proper motions of their jet components relating to systemic source expansion. The third source J0017+5312 is likely also a core-jet source, but a robust detection of a core is needed for an unambiguous identification. The kinematic ages of the CSOs derived from proper motions range from 300 to 2500 years. The kinematic age distribution of the CSOs confirm an overabundance of compact young CSOs with ages less than 500 years. CSOs with known kinematic ages may be used to study the dynamical evolution of extragalactic radio sources at early stages.

79 ASTRONOMY AND ASTROPHYSICS↗

A method for verification of treatment delivery in HDR prostate brachytherapy using a flat panel detector for both imaging and source tracking

Purpose: Verification of high dose rate (HDR) brachytherapy treatment delivery is an important step, but is generally difficult to achieve. A technique is required to monitor the treatment as it is delivered, allowing comparison with the treatment plan and error detection. In this work, we demonstrate a method for monitoring the treatment as it is delivered and directly comparing the delivered treatment with the treatment plan in the clinical workspace. This treatment verification system is based on a flat panel detector (FPD) used for both pre-treatment imaging and source tracking. Methods: A phantom study was conducted to establish the resolution and precision of the system. A pretreatment radiograph of a phantom containing brachytherapy catheters is acquired and registration between the measurement and treatment planning system (TPS) is performed using implanted fiducial markers. The measured catheter paths immediately prior to treatment were then compared with the plan. During treatment delivery, the position of the {sup 192}Ir source is determined at each dwell position by measuring the exit radiation with the FPD and directly compared to the planned source dwell positions. Results: The registration between the two corresponding sets of fiducial markers in the TPS and radiograph yielded a registration error (residual) of 1.0 mm. The measured catheter paths agreed with the planned catheter paths on average to within 0.5 mm. The source positions measured with the FPD matched the planned source positions for all dwells on average within 0.6 mm (s.d. 0.3, min. 0.1, max. 1.4 mm). Conclusions: We have demonstrated a method for directly comparing the treatment plan with the delivered treatment that can be easily implemented in the clinical workspace. Pretreatment imaging was performed, enabling visualization of the implant before treatment delivery and identification of possible catheter displacement. Treatment delivery verification was performed by measuring the source position as each dwell was delivered. This approach using a FPD for imaging and source tracking provides a noninvasive method of acquiring extensive information for verification in HDR prostate brachytherapy.

60 APPLIED LIFE SCIENCES↗

TU-AB-201-09: Calibration of An Element of a New Directional Pd-103 Planar Source Array

Purpose: The CivaSheet™ is a new directional Pd-103 planar source array, with a variable number of discrete source elements referred to as “dots”. Each dot consists of a polymer capsule containing {sup 103}Pd and a gold shield that attenuates radiation on one side of the device to define hot and cold dose regions. Fluorescence from the gold shield is observed in the dot spectrum. Since CivaSheet™ is a planar directional source, conventional methods used for calibration of azimuthally symmetric sources are not applicable. The purpose of this work is to establish an air-kerma-strength standard and a transfer to a well chamber for clinical calibration. Methods: Primary air-kerma strength measurement of the dots was performed using a variable-aperture free-air chamber (VAFAC). Charge measurements were recorded using a well chamber with a custom insert. Anisotropy measurements were performed using a Sodium-Iodide detector. Spectral measurements were performed using a low-energy germanium detector and compared to a source without gold. The dot geometry was modeled using the MCNP6 radiation transport code. Results: Air-kerma strength measurements of a batch of four dots performed with the VAFAC were within ±1.5% of the average measured value and the measurement precision was within ±0.5%. Anisotropy measurements indicated uniform emission within the measurement uncertainty for the solid angle defining the VAFAC aperture used. Charge measurements of each dot using the well chamber in four cardinal angle source orientations were within ±1.5% of the average measured values. The spectral study of a dot resulted in identification of fluorescence from the gold shield and primary spectral energies that were compared to MCNP6 simulations. Conclusion: Calibration procedures for the new directional Pd-103 source dot were established for future clinical use, based on the results of experimental and Monte Carlo investigations. This work was partially supported by NCI contract (HHSN261201200052C) through CivaTech Oncology Inc.

60 APPLIED LIFE SCIENCES↗

Impact of Organic-Liquid Distribution and Flow-Field Heterogeneity on Reductions in Mass Flux

A series of flow-cell experiments was conducted to investigate the impact of organic-liquid distribution and flow-field heterogeneity on the relationship between source-zone mass removal and reductions in contaminant mass flux from the source zone. Changes in source-zone architecture were quantified using image analysis, allowing explicit examination of their impact on the mass-flux-reduction/mass-removal behavior. The results showed that there was minimal reduction in mass flux until a large fraction of mass was removed for systems wherein organic liquid was present solely as residual saturation in regions that were hydraulically accessible. Conversely, significant reductions in mass flux occurred with relatively minimal mass removal for systems wherein organic liquid was present at both residual and higher saturations. The latter systems exhibited multi-step mass-flux-reduction/mass-removal behavior, and characterization of the organic-liquid saturation distribution throughout flushing allowed identification of the cause of the nonideal behavior. The age of the source zone (time from initial emplacement to time of initial characterization) significantly influenced the observed mass-flux-reduction/mass-removal behavior. The results of this study illustrate the impact of both organic-liquid distribution and flow-field heterogeneity on mass-removal and mass-flux processes.

54 ENVIRONMENTAL SCIENCES↗

The Development of a Parameterized Scatter Removal Algorithm for NMIS Imaging

Neutron radiography is a powerful investigative technique for analyzing the interior structure of an object. If the true attenuation of neutrons at each position in the object can be measured, the cross-sections can be computed using the exponential attenuation formula. However, scattered neutrons will contribute to the measured neutron flux and reduce the measured attenuation. The Nuclear Materials Identification System (NMIS) uses a time-tagged and electronically collimated DT neutron source to reduce this effect; however, some of the scattering component remains. This work used Monte Carlo simulations to calculate the scattering component for a variety of scenarios. The scattering for each scenario was fit using a Gaussian distribution to derive a point scatter function. These point scatter functions were used to develop a parameterized scatter removal algorithm that can calculate and remove the scattering component for a wide range of scenarios based on operator inputs. The process used to calculate the scatter functions and develop the scatter removal algorithm is discussed in detail. Examples of simulated and experimental measurements are used to test and validate the algorithm.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Locating the Source of Forced Oscillations in Transmission Power Grids

A forced oscillation event in power grids refers to a state where malfunctioning or abnormally operating equipment causes persisting periodic disturbances in the system. While power grids are designed to damp most perturbations during standard operations, some of them can excite normal modes of the system and cause significant energy transfers across the system, creating large oscillations thousands of miles away from the source. Localization of the source of such disturbances remains an outstanding challenge due to a limited knowledge of the system parameters outside of the zone of responsibility of system operators. Here, we propose a new method for locating the source of forced oscillations that addresses this challenge by performing a simultaneous dynamic model identification using a principled maximum likelihood approach. We illustrate the validity of the algorithm on a variety of examples where forcing leads to resonance conditions in the system dynamics. Our results establish that an accurate knowledge of system parameters is not required for a successful inference of the source and frequency of a forced oscillation. We anticipate that our method will find a broader application in general dynamical systems that can be well described by their linearized dynamics over short periods of time.

24 POWER TRANSMISSION AND DISTRIBUTION↗

CF Neutron Time of Flight Transmission for Material Identification for weapons Trainers

The neutron transmission, elastic scattering, and non-elastic reactions can be used to distinguish various isotopes. Neutron transmission as a function of energy can be used in some cases to identify materials in unknown objects. A time tagged californium source that provides a fission spectrum of neutrons is a useful source for neutron time-of-flight (TOF) transmission measurements. Many nuclear weapons trainer units for a particular weapons system (no fissile, but of same weight and center of gravity) in shipping containers were returned to the National Nuclear Security Administration Y-12 National Security Complex in the mid 1990s. Nuclear Materials Identification System (NMIS) measurements with a time tagged californium neutron source were used to verify that these trainers did not contain fissile material. In these blind tests, the time distributions of neutrons through the containers were measured as a function of position to locate the approximate center of the trainer in the container. Measurements were also performed with an empty container. TOF template matching measurements were then performed at this location for a large number of units. In these measurements, the californium source was located on one end of the container and a proton recoil scintillator was located on the other end. The variations in the TOF transmission for times corresponding to 1 to 5 MeV were significantly larger than statistical. Further examination of the time distribution or the energy dependence revealed that these variations corresponded to the variations in the neutron cross section of aluminum averaged over the energy resolution of the californium TOF measurement with a flight path of about 90 cm. Measurements using different thicknesses of aluminum were also performed with the source and detector separated the same distance as for the trainer measurements. These comparison measurements confirmed that the material in the trainers was aluminum, and the total thickness of aluminum through the trainers was determined. This is an example of how californium transmission TOF measurements can be used to identify materials.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

OPTICAL SPECTRA OF CANDIDATE INTERNATIONAL CELESTIAL REFERENCE FRAME (ICRF) FLAT-SPECTRUM RADIO SOURCES

Continuing our program of spectroscopic observations of International Celestial Reference Frame (ICRF) sources, we present redshifts for 120 quasars and radio galaxies. Data were obtained with five telescopes: the 3.58 m European Southern Observatory New Technology Telescope, the two 8.2 m Gemini telescopes, the 2.5 m Nordic Optical Telescope (NOT), and the 6.0 m Big Azimuthal Telescope of the Special Astrophysical Observatory in Russia. The targets were selected from the International VLBI Service for Geodesy and Astrometry candidate International Celestial Reference Catalog which forms part of an observational very long baseline interferometry (VLBI) program to strengthen the celestial reference frame. We obtained spectra of the potential optical counterparts of more than 150 compact flat-spectrum radio sources, and measured redshifts of 120 emission-line objects, together with 19 BL Lac objects. These identifications add significantly to the precise radio-optical frame tie to be undertaken by Gaia, due to be launched in 2013, and to the existing data available for analyzing source proper motions over the celestial sphere. We show that the distribution of redshifts for ICRF sources is consistent with the much larger sample drawn from Faint Images of the Radio Sky at Twenty cm (FIRST) and Sloan Digital Sky Survey, implying that the ultra-compact VLBI sources are not distinguished from the overall radio-loud quasar population. In addition, we obtained NOT spectra for five radio sources from the FIRST and NRAO VLA Sky Survey catalogs, selected on the basis of their red colors, which yielded three quasars with z > 4.

79 ASTRONOMY AND ASTROPHYSICS↗

The selective and efficient laser ion source and trap project LIST for on-line production of exotic nuclides

Laser ion sources based on resonant excitation and ionization of atoms are well-established tools for selective and efficient production of radioactive ion beams. A recent trend is the complementary installation of reliable state-of-theart all solid-state Ti:Sapphire laser systems. To date, 35 elements of the Periodic Table are available at laser ion sources by using these novel laser systems, which complements the overall accessibility to 54 elements including use of traditional dye lasers. Recent progress in the field concerns the identification of suitable optical excitation schemes for Ti:Sapphire laser excitation as well as technical developments of the source in respect to geometry, cavity material as well as by incorporation of an ion guide system in the form of the laser ion source trap LIST.

43 PARTICLE ACCELERATORS↗

Generalized parton distributions obtained with CLAS and CLAS12

Recent promising results obtained with the Jefferson Lab CLAS detector on deeply virtual exclusive processes and their link to the generalized parton distributions, along with the experimental program for studying GPDs at the 12 GeV upgraded JLab using the CLAS12 detector, are discussed here. With its wide acceptance, high luminosity, good resolution and particle identification capabilities, as well as large Q2 and xB coverage (View the MathML source, 0.1 < xB < 0.8), CLAS12 will be the ideal facility to pursue the research on the three-dimensional structure of the nucleon in the valence region.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Whole-genome sequencing and single nucleotide polymorphisms in multidrug-resistant clinical isolates of Mycobacterium tuberculosis from the Philippines

Thousands of cases of multidrug-resistant tuberculosis (TB) have been observed in the Philippines, but studies on the Mycobacterium tuberculosis (MTB) genotypes that underlie the observed drug resistance profiles are lacking. This study aimed to analyse the whole genomes of clinical MTB isolates representing various resistance profiles to identify single nucleotide polymorphisms (SNPs) in resistance-associated genes. The genomes of ten MTB isolates cultured from banked sputum sources were sequenced. Bioinformatics analysis consisted of assembly, annotation and SNP identification in genes reported to be associated with resistance to isoniazid (INH), rifampicin (RIF), ethambutol (ETH), streptomycin, pyrazinamide (PZA) and fluoroquinolones (FQs). The draft assemblies covered an average of 97.08% of the expected genome size. Seven of the ten isolates belonged to the Indo-Oceanic lineage/EA12-Manila clade. Two isolates were classified into the Euro-American lineage, whilst the pre-XDR (pre-extensively drug-resistant) isolate was classified under the East Asian/Beijing clade. The SNPs katG Ser315Thr, rpoB Ser450Leu and embB Met306Val were found in INH- (4/7), RIF- (3/6) and ETH-resistant (2/6) isolates, respectively, but not in susceptible isolates. Mutations in the inhA promoter and in the pncA and gyrA genes known to be involved in resistance to INH, PZA and FQs, respectively, were also identified. This study represents the first effort to investigate the whole genomes of Philippine clinical strains of MTB exhibiting various multidrug resistance profiles. Whole-genome data can provide valuable insights to the mechanistic and epidemiological qualities of TB in a high-burden setting such as the Philippines.

60 APPLIED LIFE SCIENCES↗

WE-A-BRD-00: MR Basics II

Ever since its introduction as a diagnostic imaging modality over 30 years ago, the radiation therapy community has acknowledged the utility of MR imaging as a tool for not only improved visualization of the target volume but also for demarcation of adjacent organs at risk. However, the adaptation of MR imaging in radiation oncology has, until recently been slow due in large part to the inability to image radiation therapy patients in their treatment position. With the introduction of so-called wide bore high field MR scanners, multi element flexible receive only RF coils, high performance imaging gradients and a range of volumetric imaging sequences it is now possible to obtain both high resolution and high signal-to-noise ratio images of in-treatment radiation therapy patients within clinically feasible imaging times. As a Result, there is renewed interest in the use of MR imaging for radiation oncology treatment planning that is being translated into physical siting and integration of these systems into radiation oncology departments. As MR imaging expands into the radiation oncology domain there is a significant and unmet need for radiation therapy physicists to become educated regarding the strengths, limitations and technical challenges associated with MR imaging. The purpose of this presentation is to address this need by providing an educational overview of the techniques and challenges associated with MR imaging of patients for radiation therapy treatment planning. As such this presentation will: 1) describe the fundamental differences between imaging of patients for diagnostic and therapeutic purposes (i.e. radiation therapy planning), 2) describe most commonly used imaging sequences and contrasts for identification of disease for radiation planning, 3) identify the most common sources of image distortion and techniques to reduce their effect on spatial fidelity of the MR data, 4) describe the effects of motion and methods to quantify/correct it, and 5) identify emergent techniques for performing MR only treatment simulation. Upon completion attendees will have a working understanding of the basic methodologies associated with MR imaging in radiation oncology, the unique technical challenges imposed by MR imaging in the treatment position and techniques to address these. Learning Objectives: 1. Understand the differences between MR imaging for diagnostic imaging and for radiation therapy planning. 2. Identify the most common sources of distortion and artifacts and simple methods to correct them. 3. Understand the challenges with MR imaging in the therapy treatment position and appropriate techniques to address them.

60 APPLIED LIFE SCIENCES↗

WE-A-BRD-01: MR Imaging for Treatment Planning: What Every Physicist Should Know

Ever since its introduction as a diagnostic imaging modality over 30 years ago, the radiation therapy community has acknowledged the utility of MR imaging as a tool for not only improved visualization of the target volume but also for demarcation of adjacent organs at risk. However, the adaptation of MR imaging in radiation oncology has, until recently been slow due in large part to the inability to image radiation therapy patients in their treatment position. With the introduction of so-called wide bore high field MR scanners, multi element flexible receive only RF coils, high performance imaging gradients and a range of volumetric imaging sequences it is now possible to obtain both high resolution and high signal-to-noise ratio images of in-treatment radiation therapy patients within clinically feasible imaging times. As a Result, there is renewed interest in the use of MR imaging for radiation oncology treatment planning that is being translated into physical siting and integration of these systems into radiation oncology departments. As MR imaging expands into the radiation oncology domain there is a significant and unmet need for radiation therapy physicists to become educated regarding the strengths, limitations and technical challenges associated with MR imaging. The purpose of this presentation is to address this need by providing an educational overview of the techniques and challenges associated with MR imaging of patients for radiation therapy treatment planning. As such this presentation will: 1) describe the fundamental differences between imaging of patients for diagnostic and therapeutic purposes (i.e. radiation therapy planning), 2) describe most commonly used imaging sequences and contrasts for identification of disease for radiation planning, 3) identify the most common sources of image distortion and techniques to reduce their effect on spatial fidelity of the MR data, 4) describe the effects of motion and methods to quantify/correct it, and 5) identify emergent techniques for performing MR only treatment simulation. Upon completion attendees will have a working understanding of the basic methodologies associated with MR imaging in radiation oncology, the unique technical challenges imposed by MR imaging in the treatment position and techniques to address these. Learning Objectives: 1. Understand the differences between MR imaging for diagnostic imaging and for radiation therapy planning. 2. Identify the most common sources of distortion and artifacts and simple methods to correct them. 3. Understand the challenges with MR imaging in the therapy treatment position and appropriate techniques to address them.

60 APPLIED LIFE SCIENCES↗