Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Simulation of distributed computing systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Distributed Optimal Power Management for Battery Energy Storage Systems: A Novel Accelerated Tracking ADMM Approach

Optimal power management (OPM) is critical for large-scale battery energy storage systems. Today’s methods often require formidable computational effort due to the design based on centralized numerical optimization. Thus, this paper investigates computationally distributed OPM where the agents based on the cells communicate over a network to cooperatively solve the OPM problem. We propose an accelerated tracking alternating direction method of multipliers (ADMM) algorithm to solve the distributed OPM. The proposed algorithm embeds dynamic average consensus and Nesterov’s acceleration technique in the ADMM algorithm. Not only is the proposed algorithm fully distributed without a need for fusion or aggregating nodes, but it also accelerates convergence. The paper formulates the OPM in a model predictive control framework where it seeks to regulate the charging/discharging power of each battery cell to minimize the total power losses and promote balanced use of the constituent cells while complying with the safety constraints. The paper provides ample simulation results to demonstrate the effectiveness and advantages of the proposed distributed OPM in terms of computation and convergence.

Farakhor, Amir↗

Modeling of H2 Dispersion at ARIES

Hydrogen is a versatile and clean energy carrier that can be produced from various renewable sources such as wind, solar, and hydropower and help decarbonize electricity grids, industry, and transportation. Using the Hydrogen Research Facility under Advanced Research on Integrated Energy Systems (ARIES) at the National Renewable Energy Laboratory's (NREL) Flatirons campus as a test bench, the study examines the feasibility, useability, and value of using computational fluid dynamics (CFD) techniques to model hydrogen dispersion. The ARIES facility was chosen because controlled hydrogen releases can be performed at a rate of 27 kg-H2/hr. Site-specific atmospheric and weather condition data such as wind speed and temperature were used as inputs to the model. The results show statistical distributions and ranges of hydrogen concentrations at locations throughout the domain. Wind conditions are found to significantly impact the release behavior, including the hydrogen cloud's direction and concentrations. At low wind speeds (below 1 mph), hydrogen forms a cloud and at higher wind speeds (> 2-4 mph) hydrogen plume stretches in the direction of wind momentum. From >100 simulations for ARIES site-specific conditions, statistical quantities combined with a clustering algorithm were used to propose sensor location at various elevations from ground.

dispersion↗

Experimental Setup and Learning-Based AI Model for Developing Accurate PV Inverter Models [Slides]

The integration of power electronics-based interfaces presents challenges due to the absence of detailed models and the high computational complexity. Generic models used in system studies lack accuracy in capturing converter dynamics. This paper proposes a data-driven approach developed from experimental setup data. This approach enhances accuracy in photovoltaic inverter modeling. We used two types of PV inverters in the experiment. The recorded experimental data undergo processing through a machine learning model. Results from the model trained through machine learning is also presented.

14 SOLAR ENERGY↗

Neural Networks-Based Inverter Control: Modeling and Adaptive Optimization for Smart Distribution Networks

The optimal voltage control of inverter-based resources, especially under the high penetration of solar photovoltaics, is critical to the stability of the distribution power system. However, the computational complexity as well as the coordinated operation performance of the voltage control optimization in the distribution power system limits the real-time applications. To mitigate this issue, a model-free based adaptive optimal control scheme for the smart inverter is proposed to maximize the active power generation, minimize the power loss, and maintain the bus voltages in smart distribution networks. An inverter-based optimization model for coordinated operation is first established, considering the uncertainties of renewable power generation. Subsequently, by collecting the data and control strategies, the neural networks (NNs) based algorithm is proposed to efficiently predict the best possible control strategy. The main objective of this scheme is to accurately predict candidate optimal solutions with near-negligible feasibility and optimization gaps, with the advantage of avoiding complicated iteration-based numerical algorithms. Thereafter, the co-simulation among OpenDSS, MATLAB, and Python is set up to fully take advantage of the three individual software. Experiments are conducted based on different control parameter characteristics and structures of NNs. Finally, the results reveal that an average mean squared error of 0.013 and 1 ms response time are achieved, which is lower than some state-of-the-art methods.

42 ENGINEERING↗

BEEAM (Building Electrical Efficiency Analysis Model) [SWR-20-107]

Modern high-performance buildings exhibit an increasing number of building loads that use direct current (DC) electricity internally, rather than alternating current (AC), due to the advent of low-cost computing and advanced power electronics. Powering DC devices from the AC grid requires AC/DC power conversion, which introduces energy losses and reduces efficiency. As DC loads proliferate, the cumulative wasted energy associated with hundreds of millions of AC/DC converters has become one of the broadest energy savings opportunities in buildings. DC power distribution systems have been proposed as an elegant and transformative solution to the problem of DC devices. In a DC distribution system, the building's wires carry DC electricity, rather than AC; and a few centralized, highly efficient AC/DC converters replace the many smaller, less efficient converters that serve individual DC loads. Unfortunately, the trade-offs associated with DC distribution systems are not well understood. Reported energy savings associated with DC power distribution differ widely and have not been well validated. The Building Electrical Efficiency Analysis Model (BEEAM) is a Modelica library that simulates the efficiency of building electrical distribution systems using harmonic power flow. BEEAM can model a wide variety of building distribution topologies, including three-phase AC, single-phase AC, unipolar DC, bipolar DC, and hybrid networks under both balanced and unbalanced load conditions. BEEAM accurately models power electronic converter losses, provides granular estimates of losses throughout the distribution system, and properly models efficiency at part load conditions. Users can package BEEAM within a functional mockup unit (FMU), enabling co-simulation with other modeling platform, such as EnergyPlus. In summary, BEEAM provides a tool suite for fair and accurate comparison of the efficiency of building electrical distribution systems, including AC, DC, and hybrid systems.

Frank, Stephen↗

Powered by dGen Webinar [Slides]

NLR's Powered By Webinar Series featuring NLR's dGen Modeling Tool. The Distributed Generation Market Demand (dGenTM) model simulates customer adoption of distributed energy resources for residential, commercial, and industrial entities in the United States or other countries through 2050. The model enables analysis at multiple geographic levels (national, state, and utility, or below) and offers sophistication in representation of decision-making regarding economic and behavioral considerations. Analysts have used dGen to answer questions about load forecasting and integrated resource planning, policy analysis, locational value of distributed energy resources, and more. dGen is open source, and various energy organizations - including independent system operators, regional transmission organizations, and the California Energy Commission - use the model internally.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Harmonized Automatic Relay Mitigation of Nefarious Intentional Events (HARMONIE) - Special Protection Scheme (SPS)

The harmonized automatic relay mitigation of nefarious intentional events (HARMONIE) special protection scheme (SPS) was developed to provide adaptive, cyber-physical response to unpredictable disturbances in the electric grid. The HARMONIE-SPS methodology includes a machine learning classification framework that analyzes real time cyber-physical data and determines if the system is in normal conditions, cyber disturbance, physical disturbance, or cyber-physical disturbance. This classification then informs response, if needed and/or suitable, and included cyber-physical corrective actions. Beyond standard power system mitigations, a few novel approaches were developed that included a consensus algorithm-based relay voting scheme, an automated power system triggering condition and corrective action pairing algorithm, and a cyber traffic routing optimization algorithm. Both the classification and response techniques were tested within a newly integrated emulation environment composed of a real-time digital simulator (RTDS) and SCEPTRE™. This report details the HARMONIE-SPS methodology, highlighting both the classification and response techniques, and the subsequent testing results from the emulation environment.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Optimal Energy Scheduling and Sensitivity Analysis for Integrated Power-Water-Heat Systems

The conventionally independent power, water, and heating networks are becoming more tightly connected, which motivates their joint optimal energy scheduling to improve the overall efficiency of an integrated energy system. However, such a joint optimization is known as a challenging problem with complex network constraints and couplings of electric, hydraulic, and thermal models that are nonlinear and nonconvex. We formulate an optimal power-water-heat flow (OPWHF) problem and develop a computationally efficient heuristic to solve it. The proposed heuristic decomposes OPWHF into subproblems, which are iteratively solved via convex relaxation and convex-concave procedure. Simulation results validate that the proposed framework can improve operational flexibility and social welfare of the integrated system, wherein the water and heating networks respond as virtual energy storage to time-varying energy prices and solar photovoltaic generation. Moreover, we perform sensitivity analysis to compare two modes of heating network control: by flow rate and by temperature. Our results reveal that the latter is more effective for heating networks with a wider space of pipeline parameters.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Evaluating MPI resource usage summary statistics

The Message Passing Interface (MPI) remains the dominant programming model for scientific applications running on today’s high-performance computing (HPC) systems. This dominance stems from MPI’s powerful semantics for inter-process communication that has enabled scientists to write applications for simulating important physical phenomena. MPI does not, however, specify how messages and synchronization should be carried out. Those details are typically dependent on low-level architecture details and the message characteristics of the application. Therefore, analyzing an application’s MPI resource usage is critical to tuning MPI’s performance on a particular platform. The result of this analysis is typically a discussion of the mean message sizes, queue search lengths and message arrival times for a workload or set of workloads. While a discussion of the arithmetic mean in MPI resource usage might be the most intuitive summary statistic, it is not always the most accurate in terms of representing the underlying data. In this paper, we analyze MPI resource usage for a number of key MPI workloads using an existing MPI trace collector and discrete-event simulator. Our analysis demonstrates that the average, while easy and efficient to calculate, is a useful metric for characterizing latency and bandwidth measurements, but may not be a good representation of application message sizes, match list search depths, or MPI inter-operation times. Additionally, we show that the median and mode are superior choices in many cases. We also observe that the arithmetic mean is not the best representation of central tendency for data that are drawn from distributions that are multi-modal or have heavy tails. Furthermore, the results and analysis of our work provide valuable guidance on how we, as a community, should discuss and analyze MPI resource usage data for scientific applications.

97 MATHEMATICS AND COMPUTING↗

Thermal Hydraulic Experimental Test Article - Fiscal Year 2023 (Final Report)

The Thermal Hydraulic Experimental Test Article (THETA) is a facility that is used to develop sodium components and instrumentation as well as acquire experimental data for validation of reactor thermal hydraulic and safety analysis codes. The facility simulates nominal conditions as well as protected/unprotected loss of flow accidents in a sodium-cooled fast reactor (SFR). High fidelity distributed temperature profiles of the developed flow field may be acquired with Rayleigh backscatter based optical fiber temperature sensors. The facility was designed in partnership with systems code experts to tailor the experiment to ensure the most relevant and highest quality data for code validation. THETA is comprised of a traditional primary coolant and secondary coolant system. The primary system is submerged in the pool of sodium and consists of a pump, electrically heated core, intermediate heat exchanger, and connected piping and thermal barriers (redan). The secondary system, located outside of the sodium pool, consists of a pump, sodium to air heat exchanger, and connected piping and valves. To date a test matrix has been completed utilizing the primary system of THETA. These tests, along with computational fluid dynamics and systems code models, determined the heat transfer across the core barrel and intermediate heat exchanger outlet was too great to effectively represent scaled thermal hydraulic phenomena of a liquid metal cooled reactor. Therefore, a significant effort was made to remove the primary system from the METL 28” test vessel #4 and clean the residual sodium from the primary system to facilitate upgrades. Thermal insulation was then incorporated in the core barrel and intermediate heat exchanger outlets. The primary system was then replaced, and a series of tests were performed to assess the performance of the thermal insulation. With primary system testing and upgrades complete, the secondary system could then be brought online. The tube side of the shell-and-tube intermediate heat exchanger was installed onto the primary system flange to begin installing the secondary system. The support structure for the secondary system was then erected on the METL mezzanine alongside the THETA primary system to facilitate installation of the secondary system components (sodium-to-air heat exchanger, flowmeter and pump). The piping and expansion tank were welded into the secondary system. Non-destructive examination of the secondary system welds was completed in order to satisfy ASME B31.3 pipe code for class M process fluids. The heating system and insulation were then added to prepare the system to be filled with sodium. The ancillary electrical equipment was installed which included the pump control box, blower VFD, pipe heater control system, etc. The secondary system will be filled, and a test matrix will be completed in early FY2024.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Multi-parametric analysis for mixed integer linear programming: An application to transmission upgrade and congestion management

Upgrading the capacity of existing transmission lines is essential for meeting the growing energy demands, facilitating the integration of renewable energy, and ensuring the security of the transmission system. This study focuses on the selection of lines whose capacities and by how much should be expanded from the perspective of the Independent System Operators (ISOs) to minimize the total system cost. We employ advanced multi-parametric programming and an enhanced branch-and-bound algorithm to address complex mixed-integer linear programming (MILP) problems, considering multi-period time constraints and physical limitations of generators and transmission lines. To characterize the various decisions in transmission expansion, we model the increased capacity of existing lines as parameters within a specified range. This study first relaxes the binary variables to continuous variables and applies the Lagrange method and Karush-Kuhn-Tucker (KKT) conditions to obtain optimal solutions and identify critical regions associated with active and inactive constraints. Moreover, we extend the traditional branch-and-bound (B&B) method by determining the problem’s upper and lower bounds at each node of the B&B decision tree, helping to manage computational challenges in large-scale MILP problems. Here, we compare the difference between the upper and lower bounds to obtain an approximate optimal solution within the decision-makers’ tolerable error range. In addition, the first derivative of the objective function on the parameters of each line is used to inform the selection of lines for easing congestion and maximizing social welfare. Finally, the capacity upgrades are selected by weighing the reductions in system costs against the expense of upgrading line capacities. The findings are supported by numerical simulations and provide transmission-line planners with decision-making guidance.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Scalable PDC Placement Technique for Fast and Resilient Monitoring of Large Power Grids

The wide-area measurement system (WAMS) is a key enabler of real-time monitoring of power grids. The essential goals of WAMS design are fast and resilient data transfer from phasor measurement units (PMU) to phasor data concentrators (PDC). We propose a scalable two-stage PDC placement technique for minimizing the end-to-end delay while maintaining resiliency. In the prescreening stage, the plausible candidates of PDC configurations are identified based on a graph theory-based multi-median function (MMF). Here, in this article, a computationally efficient meta-heuristic algorithm is used to address scalability. In the candidate selection stage, two different algorithms, namely, Suurballe's and Dijkstra's, are employed to identify the best of those plausible PDC configurations as the final design. This technique not only minimizes the hop paths between PMUs and PDCs, but also ensures network resiliency against single PMU, PDC, or communication link failure by incorporating the roles of PMUs in power grid observability into routing policy. Simulation results on the IEEE 57-bus test power system and the 2000-bus test power system demonstrate the effectiveness and scalability of the proposed technique.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Reactive Transport Modeling with Physics-Informed Machine Learning for Critical Minerals Applications

This study presents a physics-informed neural network (PINN) framework for reactive transport modeling for simulating fast bimolecular reactions in porous media. Accurate characterization of cAhemical interactions and product formation in surface and subsurface environments is essential for advancing critical mineral extraction and related geoscience applications. The proposed methodology sequentially addresses the flow and diffusion–reaction subproblems. The flow field is computed using a mixed formulation, while the diffusion–reaction system is modeled via two uncoupled tensorial diffusion equations reformulated in terms of chemical invariants. PINNs are employed to solve the governing equations, enabling data-efficient, mesh-free prediction of chemical concentration fields. The framework is validated through a series of benchmark problems involving flow in heterogeneous porous media. Initial verification is conducted using patch tests for the flow field, followed by validation of the transport problem with emphasis on preserving non-negativity of concentrations. The complete fast bimolecular reaction scenario is then solved, yielding spatial distributions of reactants and product species. Results demonstrate that the PINNs-based approach effectively captures sharp, mixing-limited reaction fronts and dispersive mixing behavior, offering reliable predictions of reactive plume evolution. These capabilities are crucial for evaluating long-term subsurface behavior in applications such as fluid storage, energy extraction, and efficient extraction of critical minerals.

42 ENGINEERING↗

Dark Matter Velocity Distributions for Direct Detection: Astrophysical Uncertainties Are Smaller Than They Appear

The sensitivity of direct detection experiments depends on the phase-space distribution of dark matter near the Sun, which can be modeled theoretically using cosmological hydrodynamical simulations of Milky Way–like galaxies. However, capturing the halo-to-halo variation in the local dark matter speeds—a necessary step for quantifying the astrophysical uncertainties that feed into experimental results—requires a sufficiently large sample of simulated galaxies, which has been a challenge. In this Letter, we quantify this variation with nearly 100 Milky Way–like galaxies from the tng50 simulation, the largest sample to date at this resolution. Moreover, we introduce a novel phase-space scaling procedure that endows every system with a reference frame that accurately reproduces the local standard-of-rest speed of our Galaxy, providing a principled way of extrapolating the simulation results to real-world data. The ensemble of predicted speed distributions is well characterized by the standard halo model, a Maxwell-Boltzmann distribution truncated at the escape speed, though the individual distributions can deviate from it, especially at high speeds. The dark matter–nucleon cross section limits placed by these speed distributions vary by ∼ 60% about the median. This places the 1⁢𝜎 astrophysical uncertainty at or below the level of the systematic uncertainty of current ton-scale detectors, even down to the energy threshold. The predicted uncertainty remains unchanged when subselecting on those TNG 50 galaxies with merger histories similar to the Milky Way. Tabulated speed distributions, as well as Maxwell-Boltzmann fits, are provided for use in computing direct detection bounds or projecting sensitivities.

Milky Way↗

Realizing mechanical frustration at the nanoscale using DNA origami

Structural designs inspired by physical and biological systems have been previously utilized to develop mechanical metamaterials with enhanced properties based on clever geometric arrangement of constituent building blocks. Here, we use the DNA origami method to realize a nanoscale metastructure exhibiting mechanical frustration, a counterpart of the well-known phenomenon of magnetic frustration. By selectively actuating reconfigurable struts, it adopts either frustrated or non-frustrated states, each characterized by distinct free energy profiles. While the non-frustrated state distributes the strain homogeneously, the frustrated mode concentrates it at a specific location. Molecular dynamics simulations reconcile the contrasting behaviors and provide insights into underlying mechanics. We explore the design space further by tailoring responses through structural modifications. Our work combines programmable DNA self-assembly with mechanical design principles to overcome engineering limitations encountered at the macroscale to design dynamic, deformable nanostructures with potential applications in elastic energy storage, nanomechanical computation, and allosteric mechanisms in DNA-based nanomachinery.

DNA nanostructures↗

Real-Time Distributed Control of Smart Inverters for Network-level Optimization

The limitations of centralized optimization methods in managing electric power distribution systems operations have led to the distributed paradigm of computing and decision-making. Unfortunately, the existing distributed optimization algorithms are limited in their applicability to managing fast varying phenomena such as those resulting from highly variable Distributed Energy Resource (DER) generation patterns. They require a large number of communication rounds (in the order of 10 2 to 10 3 ) among the computing agents to solve one instance of the optimization problem. Related real-time distributed control methods are equally limited in their applications to power distribution systems with fast-changing DER generation; they require hundreds of rounds of communication and thus are slow in tracking the network-level optimal solutions. In this paper, we propose a novel distributed voltage controller that provides a fast-tracking of rapidly varying DER generation profiles while simultaneously converging to network-level optimal solutions within a few communication rounds. The proposed control algorithm leverages the radial topology of the system, which reduces the required communication rounds to reach the network-level optimum solution by order of magnitude. The novelty lies in carefully reducing the electrical network model from the perspective of each distributed controller and enabling appropriate data sharing among upstream and downstream nodes to achieve fast convergence. The simulation results demonstrate the effectiveness of the proposed approach in minimizing the feeder losses while maintaining the node voltage within the pre-specified limits.

voltage control, optimization, reactive power, inv↗

Cooperative fault management for resilient integration of renewable energy

Cooperative fault management (CFM) is designed herein to control different types of renewable energy resources cooperatively during electrical faults. This paper studies systems with a high penetration of photovoltaic (PV) energy and wind energy. First, CFM leverages power converters of PV farms to boost the ride-through capability of nearby doubly-fed induction generators (DFIGs). By controlling PV farms’ output voltages to change smoothly during both fault initiation and fault clearance, the widely used crowbar in DFIGs is less likely to be activated. Crowbar activation adversely makes DFIGs lose controllability and absorb reactive power. The second contribution is the development of a software-defined CFM controller and a controller in-the-loop demonstration of the real-time performance of this optimization-based CFM. CFM capitalizes on distributed optimization formulation to enable flexibility, plug-and-play, and privacy-preserving. Computation time, however, is a major concern for optimization-based dynamics control. Here, real-time controller-in-the-loop simulation results show optimization-based CFM can output reference values around 60 ms and is quick enough for dynamic control.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Role of Dynamic Polarization Interactions in the Electrical Double Layer at Calcite (104) Interfaces with Aqueous Solutions

Reactions at mineral interfaces with aqueous solutions control many geochemical and biogeochemical processes in the Earth’s critical zone. At the molecular level, insights into important properties such as the structure of the electrical double layer (EDL) at specific mineral interfaces continue to improve due to the increasing fidelity of laboratory instrumentation and computational approaches. However, molecular simulation approaches suffer from limited reach into relevant scales of time, length, and system complexity. To span this gap, a novel hybrid approach that couples first principle plane-wave density functional theory (DFT) with classical DFT (cDFT) is demonstrated and applied to calcite (104) interfaces with various electrolytes. In this approach, a region of interest described using DFT interacts with the surrounding medium described using cDFT to arrive at a self-consistent ground state. Benchmarking against experimental observations and entirely first principle DFT simulations demonstrates that this hybrid model efficiently encompasses the key short-range and collective interactions in the EDL. Simulations of calcite (104)/solution interfaces reveal the key static and dynamic polarization interactions that give rise to structuring of ions and water. Ion hydration interactions have the strongest effect on the depth of the first minimum in the density distribution of counterions at the surface, and the position and width of the first density peak is largely determined by the strength of ion-correlation forces. Finer details of ion distributions are controlled by mutual polarization of the calcite surface and interfacial electrolyte. Finally, this new ability to efficiently and rigorously predict EDL structure at mineral surfaces in contact with complex solutions paves the way to accurately modeling sorption, nucleation, dissolution, and growth in realistic systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗