Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Sample Handling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Emergent Properties of Antiagglomerant Films Control Methane Transport: Implications for Hydrate Management

The relationship between collective properties and performance of antiagglomerants (AAs) used in hydrate management is handled using molecular dynamics simulations and enhanced sampling techniques. A thin film of AAs adsorbed at the interface between one flat sII methane hydrate substrate and a fluid hydrocarbon mixture containing methane and $n$-dodecane is studied. The AA considered is a surface-active compound with a complex hydrophilic head that contains both amide and tertiary ammonium cation groups and hydrophobic tails. At a sufficiently high AA density, the interplay between the surfactant layer and the liquid hydrocarbon excludes methane from the interfacial region. In this scenario, we combine metadynamics and umbrella sampling frameworks to study accurately the free-energy landscape and the equilibrium rates associated with the transport of one methane molecule across the AA film. We observe that the local configurational changes of the liquid hydrocarbon packed within the AA film are associated with high free-energy barriers for methane transport. The time scales estimated for the transport of methane across the AA film can be, in some cases, comparable to those reported in the literature for the growth of hydrates, suggesting that one possible mechanism by which AAs delay the formation of hydrate plugs could be providing a barrier to methane transport. Considering the interplay between the structural design and collective properties of AAs might be of relevance to improve their performance in flow assurance.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Automated Systems for Solvent Extraction

An automated solvent extraction system for the eventual handling of radioactive materials has been designed and procured for rapid, efficient and safe liquid-liquid extraction processes. This system will be configured to carry out liquid-liquid separations from beginning to end, automating tedious and time-consuming tasks such as organic/aqueous phase prep, pH checks, phase separation, and metal ion analysis. The system features advanced liquid handling capabilities, a robotic arm for precise sample transfer, and sophisticated analytical tools including UV-VIS spectrophotometry for real-time monitoring. Additionally, it incorporates automated capping of vials, vortex mixing, and centrifugation to ensure thorough mixing and phase separation. This report provides an overview of the system and general capabilities as well as initial efforts to develop an automated workflow for liquid-liquid separations.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Automatic Calibration and Health Monitoring of Infrastructure Sensors

Smart transportation infrastructure relies on networks of heterogeneous sensors - cameras, radars, and lidars - continuously monitoring traffic conditions. However, executing the initial spatial calibration of multiple sensors and the subsequent health monitoring presents significant operational challenges. Environmental factors, mechanical vibrations, and gradual drift cause spatial misalignment, degrading fusion performance and tracking accuracy. Traditional calibration approaches require manual intervention with specialized targets or survey equipment, resulting in service interruptions and high maintenance costs. This work presents an automated framework for initial calibration and continuous health monitoring without human intervention or service disruption. Our approach addresses two critical problems: (1) detecting when sensors become miscalibrated during operation, and (2) automatically re-establishing spatial alignment using only operational traffic data. The health monitoring component analyzes measurement innovations - differences between sensor observations and predicted object states - to detect systematic biases indicative of calibration drift. By computing bias magnitude, directional consistency, and rejection rates, the system identifies miscalibrations as small as 0.5 meters. Unlike traditional methods requiring known calibration targets, our diagnostic operates continuously on live traffic observations, enabling early detection before fusion quality degrades. The automatic recalibration algorithm leverages overlapping sensor fields-of-view and temporal correlation of vehicle observations. Using graph-based optimization, the system automatically discovers which sensor pairs observe common regions, estimates pairwise spatial transformations using RANSAC-based robust estimation, and jointly optimizes all sensor poses through bundle adjustment. The framework handles practical deployment challenges, including different sensor sampling rates (1-10 Hz), varying installation positions, unknown orientations, and limited overlap regions (>10%). When approximate sensor positions are available from installation surveys (+/-1m accuracy), the algorithm additionally estimates sensor orientations, refining both position and rotation to sub-meter and sub-degree accuracy. We validate the framework on multi-hour traffic datasets from six heterogeneous sensors with sampling rates ranging from 1 Hz to 10 Hz. Results demonstrate successful calibration even with sparse overlap (<20%) and automatic detection of miscalibrations exceeding 0.8 meters. This work enables a "deploy-and-forget" sensor infrastructure that maintains calibration autonomously, reducing maintenance costs while improving tracking accuracy. The techniques generalize beyond transportation to any multi-sensor monitoring application requiring robust spatial alignment, including smart cities, industrial monitoring, and surveillance systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

ROMPS critical design review. Volume 1: Hardware

Topics concerning the Robot-Operated Material Processing in Space (ROMPS) Program are presented in viewgraph form and include the following: a systems overview; servocontrol and servomechanisms; testbed and simulation results; system V controller; robot module; furnace module; SCL experiment supervisor; SCL script sample processing control; SCL experiment supervisor fault handling; block diagrams; hitchhiker interfaces; battery systems; watchdog timers; mechanical/thermal systems; and fault conditions and recovery.

Dobbs, M. E.↗

A review of design concepts for the Advanced Fluids Module (AFM) project

This paper reviews preliminary fluid module design concepts for the Advanced Fluids Module (AFM) project. The objective of this effort is to provide a facility that can handle a wide variety of fluids experiments. Sample science requirements were written and conceptual designs were subsequently generated during the last year. Experiments from the following fluid physics subject areas were used as conceptual design drivers: static and dynamic interfacial phenomena; bubble/droplet thermocapillary migration; surface tension convection and instabilities; thermal/solutal convection; pool boiling; and multiphase flow. After the conceptual designs were completed, the next phase attempted to combine experiments capabilities into a multipurpose, multiuser apparatus configured for the Space Station Freedom. It was found that all the fluid subject areas considered could be accommodated by three basic types of fluids modules. These modules are the Static Fluid Cell Module, the Dynamic Fluid Cell Module, and the Multiphase Flow Module. Descriptions of these preliminary modules designs and their particular sub-systems (e.g., fluid and thermal systems) are discussed. These designs will be refined as the nature of the flight program becomes clearer over the next six to twelve months.

Hill, Myron E.↗

Exposure Limits for Hydrogen Sulfide in Spaceflight

Hydrogen sulfide (H 2 S) has not historically been detected in spacecraft, but the possible evolution of volatile components from polar ice on the lunar surface is a potential concern for NASA’s planned Artemis missions. Numerous case reports and occupational epidemiological studies document that exposure to H 2 S at high concentrations has effects on the respiratory system, potentially leading to unconsciousness followed by debilitating neurological effects. Studies in rodents demonstrate sensitivity of the respiratory system to lower concentrations of H 2 S. Adverse respiratory effects have also been indicated in workers chronically exposed to H 2 S. The objective of the present publication is to develop Spacecraft Maximum Allowable Concentrations (SMACs) for H 2 S for all current standard durations of exposure for spaceflight (1-hour, 24-hours, 7-days, 30-days, 180-days, and 1000-days). Summary sources and literature review were used to identify relevant studies to inform SMAC development. Space flight mission specific activities and most probable exposure scenarios were used to determine the relevant toxicity endpoints and supporting studies. SMACs were established for hydrogen sulfide of 5 ppm for 1-hour, 1.3 ppm for 24-hours, 1.3 ppm for 7-days, 1.3 ppm for 30-days, and 0.3 ppm for 180-days. Data are not sufficient currently to establish a 1000-day SMAC value. SMACs for H 2 S will support development of handling protocols and proper containment for lunar sample collection.

hydrogen sulfide↗

Diamond as a solid state micro-fission chamber for thermal neutron detection at the VR-1 research reactor

Diamond exhibits a combination of properties which makes it attractive for neutron detection in hostile conditions. In the particular case of detection in a nuclear reactor, it is resilient to radiation, exhibits a natural low sensitivity to gamma rays, and its small size (as compared with that of gas ionisation chambers) enables fluency monitoring with a high position resolution. We report here on the use of synthetic CVD diamond as a solid state micro-fission chamber with U-235 converting material for in-core thermal neutron monitoring. Two types of thin diamond detectors were developed for this application. The first type of detector is fabricated using thin diamond membrane obtained by etching low-cost commercially available single crystal CVD intrinsic diamond, so called 'optical grade' material. Starting from a few hundred of micrometre thick samples, the sample is sliced with a laser and then plasma etched down to a few tenths of micrometre. Here we report the result obtained with a 17 μm thick device. The detection surface of this detector is equal to 1 mm{sup 2}. Detectors with surfaces up to 1 cm{sup 2} can be fabricated with this technique. The second type of detector is fabricated by growing successively two thin films of diamond, by the microwave enhanced chemical vapour deposition technique, on HPHT single crystal diamond. A first, a film of boron doped (p+) single crystal diamond, a few microns thick, is deposited. Then a second film of intrinsic diamond with a thickness of a few tens of microns is deposited. This results in a P doped, Intrinsic, Metal structure (PIM) structure in which the intrinsic volume id the active part of the detector. Here we report the results obtained with a 20 μm thick intrinsic whose detection surface is equal to 0.5 mm{sup 2}, with the possibility to enlarge the surface of the detector up to 1 cm{sup 2}. These two types of detector were tested at the VR-1 research reactor at the Czech Technical University in Prague. The Training Reactor VR-1 is a pool type (light water) reactor based on UO{sub 2} low enriched uranium. It has a nominal power of 1 kW, and can be operated for a short period up to 5 kW. The arrangement of the reactor pool reactor facilitates access to the core, setting and removal of various experimental samples and detectors, and safe and easy handling of fuel assemblies. The reactor is equipped with two horizontal channels (radial and tangential) and 10 vertical channels, of varying diameters, which can be loaded into various core positions, and one pneumatic transfer system. It is also equipped with several specifically designed educational instrumentation systems that can be used to supply complementary measurements and characterization around the reactor. The reactor is operated by the Department of Nuclear Reactors of the Faculty of Nuclear Sciences and Physical Engineering of the Czech Technical University in Prague. The two detectors were placed in-core through one of the vertical insertion channel. They were coupled to remote placed (5 m BNC cable) classical nuclear charge sensitive electronics. Detection properties of both sensors, including: pulse height spectra of U-235 fission fragments (response linearity with neutron flux, count rate, gamma background, were evaluated varying the power of the reactor from 0.005 W to 500 W. The evolution of the counting rate of the thinned optical grade detector as a function of counting rate of a gas ionization chamber used currently for reactor monitoring shows the very good linearity of the detector over the 5 decades. Similar results were obtained with the PIM detector. Additionally fast transient current signals of the detectors were recorded on a digital storage oscilloscope (DSO) using broad-band amplifier and with a simple bias-T, showing potential use of such sensors for neutron counting with no need of an amplification stage, since non-amplified signals from fission fragments exceeded 4 mV in amplitude. Therefore, one can think of simple neutron counting system by feeding diamond detectors signals directly to the low threshold discriminators. The results obtained on the VR1 will be described and discussed in detail in the paper and associated presentation. The results demonstrate that diamond micro-fission chambers can be used for in-core neutron monitoring, where robust, simple and compact devices are required.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Effects of sampling techniques on short-term survival and genotyping success of salmonid fry

ABSTRACT Objective Genetics tools have become an integral part of managing and understanding fish populations. Generally, a small tissue sample, such as a fin clip, is taken and then genotyped, with little effect on survival of the fish. However, tissue sampling may have a larger effect on juvenile fish survival compared to their adult counterparts. We evaluated survival and genotyping success of various genetic sampling techniques for Chinook Salmon Oncorhynchus tshawytscha and Rainbow Trout Oncorhynchus mykiss fry. Methods Three sampling treatments were evaluated including control (anesthetized and handled), fin clipping (partial caudal fin clip), and swabbing (OmniSwab was used to collect external mucus). Survival was monitored for 12 d posttreatment, and genotyping success was evaluated. Results Survival was high in all treatment groups (i.e., 0.93–1.00) but, on average, was lower in the swab treatment group. Genotyping was successful in 100% of the fin clip samples and 11–50% of the swab samples. Conclusions Results of this study suggest that sampling caudal-fin tissue does not negatively affect fry short-term survival and the small tissue samples yield highly successful genotyping results. Swabbing did not produce successful genotyping results, and fish sampled with swabs experienced higher mortality than those that received fin clips. Results indicate that fin clips should be used for collection of genetic samples from fry.

McCarrick, Darcy K.↗

Small Particle Glovebox Experiments - Preliminary Results

A substantial portion of the asteroid samples returned by the HAYABUSA2 and OSIRIS-REx missions will consist of small (submm) components (due to the collection of those particles on the asteroid surface and due to the fragmenting of larger, friable material post-collection). In order to minimize the alteration/oxidation of asteroid regolith, the bulk collections will be stored and curated in nitrogen purged gloveboxes. The processing of small particles in an N2 glovebox will present challenges that are different from those experienced during lunar and meteorite sample processing. Particles in this size range are susceptible to unpredictable electrostatic charging that can result in sample loss during processing operations. Methods for the handling of sub-mm particles have been well developed for environments with ambient atmospheric conditions and relative humidity (RH) ranges between 40-70%. In such conditions, a number of factors can be successfully employed to minimize the effects of triboelectric charging, including the use of Po-210 sources that neutralize excess charge and the utilization of conductive manipulation tools and sample substrates. However, relative humidity levels above 40% also contribute significantly to dissipation of triboelectric effects. We had not previously investigated our charge mitigation methods in a completely dry, nitrogen-purged environment, or whether they would be sufficient in enabling the successful processing of sub-mm samples. Current glovebox configurations in use in our lunar and meteorite curation laboratories are optimized for the processing of macroscopic samples and tools; these glovebox designs are likely unsuitable for the processing of collections for which the bulk collection is comprised of sub-mm components. Small particle sample preparation requires the use of an optical magnification instrument – typically a stereo binocular microscope with at least 20x magnification. Current glovebox designs are not optimized for the utilization or integration of stereo microscopes; while many current cabinets include microscope viewports that enable the use of small, externally mounted stereo microscopes, the focusing methods (usually involving the use of a lab jack) lack the fidelity and precision required for small particle manipulation and imaging. Working distances of higher (>50x magnification) objective lenses may preclude the external use of a stereo microscope through a viewport; in order to successfully manipulate and image very small (< 20m) particles, stereo and digital microscope systems that are integrated within the glovebox should be investigated. Finally, ergonomic considerations for small particle work within a glovebox must be considered to minimize risk of injury to sample processors. In order to investigate some of the unknown parameters relating to small particle processing within an N2 glovebox, we conducted preliminary, qualitative experiments utilizing a small lunar cabinet that was originally used for film development.

C. J. Snead↗

Remote-Handled TRU Storage Challenges at Sandia National Laboratories/ New Mexico - 16071

The events at the Waste Isolation Pilot Plant (WIPP) in February 2014 had a significant impact on the packaging, storage, and disposal options at Sandia National Laboratories/New Mexico (Sandia) as with other transuranic generator sites. In 2012, Sandia had identified accountable material for disposal, fresh and irradiated mixed oxide (MOX) and uranium oxide (UO{sub 2}), which had been used in experiments conducted in the 1970's and 1980's. During the 2012/2013 timeframe, discussions with WIPP determined the samples and experimental vessels qualified as remote-handled (RH) transuranic (TRU) waste for disposal at WIPP. Sandia began discussions with WIPP to determine the process to repackage and characterize the material for disposal at WIPP in addition to obtain funding to complete the project. By January 2014, Sandia had contracted with Nuclear Waste Partnerships, LLC (NWP) to provide Central Characterization Program (CCP) certified visual examination (VE) and dose-to-curie (DTC) support to package and certify the accountable material/waste. Work began on February 3, 2014 with the arrival of two VE operators. On February 5, 2014, a salt truck caught fire in the underground and on February 14, 2014, the radiological release occurred at WIPP initiating a suspension of shipments. The length of the suspension was not known at the time. Sandia was only a couple of days into this long-term project, had signed a contract with NWP for support, and was still responsible for meeting earlier negotiated milestones. There were 37 parent containers which included experimental vessels from 3 to 10 feet long and unused material pieces. The original plan was to package each of the 37 parent containers separately, but several issues, including the suspension of shipments, made it imperative that a new path forward be developed. Because space is limited in the Auxiliary Hot Cell Facility (AHCF), the storage configuration for criticality safety and material-at-risk was of the highest importance. Therefore, packaging in the fewest number of containers without exceeding WIPP limits, keeping the accountable items together, and not violating any safety basis requirements was Sandia's goal. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Keeping the Momentum and Nuclear Forensics at Los Alamos National Laboratory

LANL has 70 years of experience in nuclear forensics and supports the community through a wide variety of efforts and leveraged capabilities: Expanding the understanding of nuclear forensics, providing training on nuclear forensics methods, and developing bilateral relationships to expand our understanding of nuclear forensic science. LANL remains highly supportive of several key organizations tasked with carrying forth the Nuclear Security Summit messages: IAEA, GICNT, and INTERPOL. Analytical chemistry measurements on plutonium and uranium matrices are critical to numerous programs including safeguards accountancy verification measurements. Los Alamos National Laboratory operates capable actinide analytical chemistry and material science laboratories suitable for nuclear material and environmental forensic characterization. Los Alamos National Laboratory uses numerous means to validate and independently verify that measurement data quality objectives are met. Numerous LANL nuclear facilities support the nuclear material handling, preparation, and analysis capabilities necessary to evaluate samples containing nearly any mass of an actinide (attogram to kilogram levels).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The effects of physical and chemical preprocessing on the flowability of corn stover

Continuous and reliable feeding of biomass is essential for successful biofuel production. However, the challenges associated with biomass solids handling are commonly overlooked. In this study, we examine the effects of preprocessing (particle size reduction, moisture content, chemical additives, etc.) on the flow properties of corn stover. Compressibility, flow properties (interparticle friction, cohesion, unconfined yield stress, etc.), and wall friction were examined for five corn stover samples: ground, milled (dry and wet), acid impregnated, and deacetylated. The ground corn stover was found to be the least compressible and most flowable material. The water and acid impregnated stovers had similar compressibilities. Yet, the wet corn stover was less flowable than the acid impregnated sample, which displayed a flow index equivalent to the dry, milled corn stover. The deacetylated stover, on the other hand, was the most compressible and least flowable examined material. However, all of the tested stover samples had internal friction angles >30°, which could present additional feeding and handling challenges. All of the ''wetted'' materials (water, acid, and deacetylated) displayed reduced flowabilities (excluding the acid impregnated sample), and enhanced compressibilities and wall friction angles, indicating the potential for added handling issues; which was corroborated via theoretical hopper design calculations. All of the ''wetted'' corn stovers require larger theoretical hopper outlet diameters and steeper hopper walls than the examined ''dry'' stovers.

09 BIOMASS FUELS↗

JGI-Trichoderma v1.0

There is a series of Python and bash scripts to parse genomics datasets used to evaluate the coevolution of gene families and the feature importance of gene families using an SVM classifier. - Cover analysis: takes a list of single-copy genes in a set of genomes, aligns and builds the gene trees to determine if two gene families have a signature of covariation with one another. It parses the files to run phykit cover script described here: https://jlsteenwyk.com/PhyKIT/usage/index.html - SVM-classifier: This Python script is an SVM-based genomic classifier designed for biological data analysis. It combines machine learning with feature selection to identify important genomic markers and classify biological samples. Core Functionality: The script uses Support Vector Machines from scikit-learn to classify genomic data, incorporating SelectKBest for automated feature selection and leave-one-out cross-validation for performance assessment. It operates in multiple modes: feature ranking, optimal combination discovery, and sample prediction. Primary Applications: Genomic sample classification and biomarker discovery Feature importance analysis in high-dimensional biological datasets Prediction of sample categories based on genomic profiles Research applications requiring robust classification of biological data Key Advantages: High-dimensional handling: SVMs excel with genomic data's typical high feature-to-sample ratios Integrated feature selection: Reduces noise and computational overhead while identifying key markers Probability estimation: Provides confidence scores essential for biological interpretation Validation robustness: Leave-one-out cross-validation ensures reliable performance metrics Operational flexibility: Multiple analysis modes support different research phases from exploration to prediction

Stecca Steindorff, Andrei [Lawrence Berkeley Natio↗

PISCES two-detector covariance matrix fit for the NOvA Experiment

NOvA is a long-baseline neutrino oscillation experiment with two functionally identical detectors: a Near Detector (ND) at Fermilab, placed 1 km from the neutrino source, and a Far Detector (FD) located 810 km away from the ND in Minnesota. NOvA's primary physics goals are the precise measurements of neutrino oscillation parameters $\theta_{23}$ and $\Delta m^2_{32}$ , determine the neutrino mass ordering, and constrain the value of $\delta_{CP}$, via the study of muon neutrino to electron neutrino oscillation. In the standard NOvA three-flavor analysis, oscillation parameters are extracted using an extrapolation technique in which the ND data constrain the FD prediction through a ratio method. While this allows for systematic uncertainties sharing the same effects in both detectors to cancel, it remains an FD-only fit and does not fully leverage the constraining power of the high-statistics ND. This analysis proposes a simultaneous ND+FD fit using the PISCES method. PISCES (Parameter Inference with Systematic Covariance and Exact Statistics) is a framework designed to support complex configurations such as a joint ND+FD fit. This allows PISCES to take full advantage of the ND data to directly constrain systematic uncertainties across all samples. In PISCES, systematic uncertainties are encoded in a fractional covariance matrix, and statistical uncertainties are handled with a Poisson likelihood, making the approach well suited for low-statistics samples. For interpretability, we further use a Newton–Raphson + PCA method to recover per-systematic pulls from the covariance formulation. This poster presents the full PISCES joint ND+FD fit for the NOvA three-flavor analysis, describes its implementation and evaluates its performance through extensive robustness tests and fake data studies. It also provides a comparison between the PISCES joint ND+FD results and the standard NOvA extrapolation method.

Rajaoalisoa, Miriama [Cincinnati U.] (ORCID:000000↗

Initial Characterization of ATR End Box Samples

Aluminum samples taken from discarded irradiated Advanced Test Reactor fuel element end boxes (upper and lower adapter ) were characterized to determine the chemical composition and hydration state of the surface oxides. The samples were analyzed using scanning electron microscope imaging and chemical identification, x-ray diffraction to evaluate crystalline morphology, and thermogravitational analysis to determine mass loss by dehydration. The samples were acquired from the discarded fuel element components stored in the ATR fuel handling canal and transferred to the Materials and Fuels Complex for analysis. The measurements indicate that the samples have limited oxide thickness, indicating that little corrosion has occurred beyond the initial passive layer that was intentionally formed prior to irradiation. The presence of minimal aluminum oxyhydroxide suggests that there will be minimal risk to store these fuels in air with limited risk for alteration of the base passive layer. These observations will be compared against samples that will be taken of the same type of fuel that has been in dry storage for more than 10 years.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Ceramics for Molten Materials Containment, Transfer and Handling on the Lunar Surface

As part of a project on Molten Materials Transfer and Handling on the Lunar Surface, molten materials containment samples of various ceramics were tested to determine their performance in contact with a melt of lunar regolith simulant. The test temperature was 1600 C with contact times ranging from 0 to 12 hours. Regolith simulant was pressed into cylinders with the approximate dimensions of 1.25 dia x 1.25cm height and then melted on ceramic substrates. The regolith-ceramic interface was examined after processing to determine the melt/ceramic interaction. It was found that the molten regolith wetted all oxide ceramics tested extremely well which resulted in chemical reaction between the materials in each case. Alumina substrates were identified which withstood contact at the operating temperature of a molten regolith electrolysis cell (1600 C) for eight hours with little interaction or deformation. This represents an improvement over alumina grades currently in use and will provide a lifetime adequate for electrolysis experiments lasting 24 hours or more. Two types of non-oxide ceramics were also tested. It was found that they interacted to a limited degree with the melt resulting in little corrosion. These ceramics, Sic and BN, were not wetted as well as the oxides by the melt, and so remain possible materials for molten regolith handling. Tests wing longer holding periods and larger volumes of regolith are necessary to determine the ultimate performance of the tested ceramics.

Standish, Evan↗

Material handling device Patent

Device which separates and screens particles of soil samples for vidicon viewing in vacuum and reduced gravity environments

Ritchie, D. G.↗

Sample manipulation and data assembly for robust microcrystal synchrotron crystallography

With the recent developments in microcrystal handling, synchrotron microdiffraction beamline instrumentation and data analysis, microcrystal crystallography with crystal sizes of less than 10 µm is appealing at synchrotrons. However, challenges remain in sample manipulation and data assembly for robust microcrystal synchrotron crystallography. Here, the development of micro-sized polyimide well-mounts for the manipulation of microcrystals of a few micrometres in size and the implementation of a robust data-analysis method for the assembly of rotational microdiffraction data sets from many microcrystals are described. The method demonstrates that microcrystals may be routinely utilized for the acquisition and assembly of complete data sets from synchrotron microdiffraction beamlines.

59 BASIC BIOLOGICAL SCIENCES↗