Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SUSPECT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Asymmetric Dual Sensor Latency in Distributed Control

Considerable geographical separation between various phasor measurement unit sensor suites used in the wide-area damping control architecture results in time delays with varying steady-state and stochastic components. The consequences of asymmetric latent sensors used in a standard feedback configuration are presented, indicating that asymmetry of the delay provides not only a previously suspected modification to the argument of the loop transmission function, but also a potentially substantial impact on its modulus. Under particular delay configurations, the controller may experience the introduction of varying crossovers in the loop transmission, resulting in a shifting of control bandwidth and previously unconsidered (in)stability characteristics (e.g., alteration of relative stability margins). With consideration to the theoretical results provided, the optimal sensor location based on delay characteristics is provided. Finally, results of the study indicate that it is most frequently best practice to act on the most current sample in the feedback channel, rather than wait for precise time alignment of the delayed sensor.

42 ENGINEERING↗

VAST Challenge 2014: The Kronos Incident

The 2014 IEEE Visual Analytics Science and Technology (VAST) Challenge presented researchers with a single fictitious scenario: the disappearance of staff members of the GASTech oil and gas company on location on the island of Kronos. A group named the Protectors of Kronos (POK) was the prime suspect in the disappearance. Three mini-challenges and a grand challenge were offered. Mini-challenge 1 included multiple types of text data for participants to provide a timeline of key events and characterize the POK, mini-challenge 2 focused on individuals’ movement and financial data for participants to provide patterns of daily life, and mini-challenge 3 featured real-time streaming social media and emergency service data for participants to provide hostage and kidnapper information. The grand challenge asked the participants to integrate results and generate a synopsis of events. The VAST Challenge received 73 submissions from 13 countries

visual analytics, visualization, evaluation, VAST ↗

Identification and analysis of the bacterial endosymbiont specialized for production of the chemotherapeutic natural product ET-743

Ecteinascidin 743 (ET-743, Yondelis) is a clinically approved chemotherapeutic natural product isolated from the Caribbean mangrove tunicate Ecteinascidia turbinata . Researchers have long suspected that a microorganism may be the true producer of the anti-cancer drug, but its genome has remained elusive due to our inability to culture the bacterium in the laboratory using standard techniques. Here, we sequenced and assembled the complete genome of the ET-743 producer, Candidatus Endoecteinascidia frumentensis, directly from metagenomic DNA isolated from the tunicate. Analysis of the ~631 kb microbial genome revealed strong evidence of an endosymbiotic lifestyle and extreme genome reduction. Phylogenetic analysis suggested that the producer of the anti-cancer drug is taxonomically distinct from other sequenced microorganisms and could represent a new family of Gammaproteobacteria. The complete genome has also greatly expanded our understanding of ET-743 production and revealed new biosynthetic genes dispersed across more than 173 kb of the small genome. The gene cluster’s architecture and its preservation demonstrate that the drug is likely essential to the interactions of the microorganism with its mangrove tunicate host. In conclusion, taken together, these studies elucidate the lifestyle of a unique, and pharmaceutically-important microorganism and highlight the wide diversity of bacteria capable of making potent natural products.

54 ENVIRONMENTAL SCIENCES↗

Antibody dynamics to SARS‐CoV‐2 in asymptomatic COVID‐19 infections

Abstract Background The missing asymptomatic COVID‐19 infections have been overlooked because of the imperfect sensitivity of the nucleic acid testing (NAT). Globally understanding the humoral immunity in asymptomatic carriers will provide scientific knowledge for developing serological tests, improving early identification, and implementing more rational control strategies against the pandemic. Measure Utilizing both NAT and commercial kits for serum IgM and IgG antibodies, we extensively screened 11 766 epidemiologically suspected individuals on enrollment and 63 asymptomatic individuals were detected and recruited. Sixty‐three healthy individuals and 51 mild patients without any preexisting conditions were set as controls. Serum IgM and IgG profiles were further probed using a SARS‐CoV‐2 proteome microarray, and neutralizing antibody was detected by a pseudotyped virus neutralization assay system. The dynamics of antibodies were analyzed with exposure time or symptoms onset. Results A combination test of NAT and serological testing for IgM antibody discovered 55.5% of the total of 63 asymptomatic infections, which significantly raises the detection sensitivity when compared with the NAT alone (19%). Serum proteome microarray analysis demonstrated that asymptomatics mainly produced IgM and IgG antibodies against S1 and N proteins out of 20 proteins of SARS‐CoV‐2. Different from strong and persistent N‐specific antibodies, S1‐specific IgM responses, which evolved in asymptomatic individuals as early as the seventh day after exposure, peaked on days from 17 days to 25 days, and then disappeared in two months, might be used as an early diagnostic biomarker. 11.8% (6/51) mild patients and 38.1% (24/63) asymptomatic individuals did not produce neutralizing antibody. In particular, neutralizing antibody in asymptomatics gradually vanished in two months. Conclusion Our findings might have important implications for the definition of asymptomatic COVID‐19 infections, diagnosis, serological survey, public health, and immunization strategies.

Lei, Qing↗

Clinical practice gaps and challenges in non‐alcoholic steatohepatitis care: An international physician needs assessment

Abstract Background and aims Even as several pharmacological treatments for non‐alcoholic steatohepatitis (NASH) are in development, the incidence of NASH is increasing on an international scale. We aim to assess clinical practice gaps and challenges of hepatologists and endocrinologists when managing patients with NASH in four countries (Germany/Italy/United Kingdom/United States) to inform educational interventions. Methods A sequential mixed‐method design was used: qualitative semi‐structured interviews followed by quantitative online surveys. Participants were hepatologists and endocrinologists practising in one of the targeted countries. Interview data underwent thematic analysis and survey data were analysed with chi‐square and Kruskal‐Wallis tests. Results Most interviewees ( n = 24) and surveyed participants (89% of n = 224) agreed that primary care must be involved in screening for NASH, yet many faced challenges involving and collaborating with them. Endocrinologists reported low knowledge of which blood markers to use when suspecting NASH (56%), when to order an MRI (65%) or ultrasound/FibroScan® (46%), and reported sub‐optimal skills interpreting alanine aminotransferase (ALT, 37%) and aspartate aminotransferase (AST, 38%) blood marker test results, causing difficulty during diagnosis. Participants believed that more evidence is needed for upcoming therapeutic agents; yet, they reported sub‐optimal knowledge of eligibility criteria for clinical trials. Knowledge and skill gaps when managing comorbidities, as well as skill gaps facilitating patient lifestyle changes were reported. Conclusions Educational interventions are needed to address the knowledge and skill gaps identified and to develop strategies to optimize patient care, which include implementing relevant care pathways, encouraging referrals and testing, and multidisciplinary collaboration, as suggested by the recent Global Consensus statement on NAFLD.

Lazure, Patrice↗

Implementation of rapid diagnostics assays for detection of histoplasmosis and cryptococcosis in central american people living with HIV

Abstract Objectives Histoplasmosis and cryptococcosis are important public health problems in people living with HIV (PLHIV) in Central America. Conventional laboratory assays, based on microscopy and culture, are not optimal for the diagnosis of either disease. However, antigen (Ag) assays are rapid and highly accurate for the diagnosis of these infections. Methods Laboratory surveillance of PLHIV was carried out in four hospitals in Panama, Honduras and Nicaragua, between 2015 and 2019. Detection of Histoplasma antigens in urine was performed by enzyme immunoassay (EIA), and Cryptococcus antigen detection in sera and cerebrospinal fluid specimens was performed by lateral flow assay (LFA). Results A total of 4,453 PLHIV with clinical suspicion of histoplasmosis ( n = 1,343) or cryptococcosis ( n = 3,110; 2,721 sera and 389 CSF) were tested. Of 1,343 patients suspected of having histoplasmosis, 269 (20%) were Histoplasma Ag positive. Of 3,110 patients tested using the Cryptococcus Ag assay, 329 (11%) were positive. Honduras reported the highest positivity rates (32% for Histoplasma Ag, and 16% for Cryptococcus Ag); Panama reported the largest number of patients testing positive using the Histoplasma Ag assay ( n = 201); and Nicaragua reported the largest number of patients testing positive using the Cryptococcus Ag assay ( n = 170). Conclusion Here, we show how the implementation of rapid diagnostics assays impacted case detection and was useful for the care of people with advanced HIV. Rapid and accurate diagnosis could reduce mortality associated with histoplasmosis and cryptococcosis in PLHIV.

Caceres, Diego H.↗

Improved quantitation of SIMS depth profile measurements of niobium via sample holder design improvements and characterization of grain orientation effects

The importance of SIMS analyses for “N-doped” impurity alloyed niobium and other surface-alloyed materials continues to increase. A major hurdle is the uncertainty of instrument calibration due to changes in sample height either from sample surface topography or from the sample holder itself. The CAMECA sample holder design allows for many types of samples to be analyzed. However, a drawback is that the holder faceplate can bend, contributing an uncertainty in the relative sensitivity factor (RSF) used to quantify the SIMS results. Here, we describe an improved sample holder having a reinforced faceplate, which prevents deflection and reduces uncertainty. Simulations show that the new design significantly reduces deflection from 10 μm to 5 nm. Sample measurements show a reduction of RSF uncertainty from this source from 4.1% to 0.95%. Grain orientation has long been suspected to affect RSF measurement as well. A bicrystal implant standard, consisting of randomly oriented and [001] grains, was successively rotated 15° between analyses. It was observed that 20% of the analyses performed on the randomly oriented grain exhibited anomalously high RSF values as well as slow sputter rates. These features were associated with the changing grain normal orientation with respect to the primary Cs + beam. The grain orientation associated with the rise in RSF was simulated and determined to be the [101] crystallographic plane, thus indicating that ion channeling was responsible for the significantly increased RSF. Focused ion beam analysis confirmed slower sputter rates for the cardinal crystallographic orientations, indicating that ion channeling occurred for each.

43 PARTICLE ACCELERATORS↗

Benchmarking large language models for materials synthesis: The case of atomic layer deposition

In this work, we introduce an open-ended question benchmark, ALDbench, to evaluate the performance of large language models (LLMs) in materials synthesis, and, in particular, in the field of atomic layer deposition, a thin film growth technique used in energy applications and microelectronics. Our benchmark comprises questions with a level of difficulty ranging from the graduate level to domain expert current with the state of the art in the field. Human experts reviewed the questions along the criteria of difficulty and specificity, and the model responses along four different criteria: overall quality, specificity, relevance, and accuracy. We ran this benchmark on an instance of OpenAI’s GPT-4o. The responses from the model received a composite quality score of 3.7 on a 1–5 scale, consistent with a passing grade. However, 36% of the questions received at least one below average score. An in-depth analysis of the responses identified at least five instances of suspected hallucination. Finally, we observed statistically significant correlations between the difficulty of the question and the quality of the response, the difficulty of the question and the relevance of the response, the specificity of the question, and the accuracy of the response as graded by the human experts. Furthermore, this emphasizes the need to evaluate LLMs across multiple criteria beyond difficulty or accuracy.

Artificial intelligence↗

The Northwest Infrared (NWIR) gas-phase spectral database of industrial and environmental chemicals: Recent updates

With continuing improvements in both standoff- and point-sensing techniques, there is an ongoing need for high-quality infrared spectral databases. The Northwest Infrared Database (NWIR) contains quantitative, gas-phase infrared spectra of nearly 500 pure chemical species that can be used for a variety of applications such as atmospheric monitoring, biomass burning studies, etc. The data, recorded at 0.1 cm-1 resolution, are pressure broadened to one atmosphere (N2) in order to mimic atmospheric conditions. Each spectrum is a composite composed of multiple individual measurements. Recent updates to the database include over 60 molecules that are known or suspected biomass-burning effluents. Examples from this set of measurements will be presented and experimental details will be discussed in the context of the utility of NWIR for environmental applications.

quantitative infrared spectra, absorption cross-se↗

Hyperspectral vegetation identification at a legacy underground nuclear explosion test site

The detection, location, and identification of suspected underground nuclear explosions (UNEs) are global security priorities that rely on integrated analysis of multiple data modalities for uncertainty reduction in event analysis. Vegetation disturbances may provide complementary signatures that can confirm or build on the observables produced by prompt sensing techniques such as seismic or radionuclide monitoring networks. For instance, the emergence of non-native species in an area may be indicative of anthropogenic activity or changes in vegetation health may reflect changes in the site conditions resulting from an underground explosion. Previously, we collected high spatial resolution (10 cm) hyperspectral data from an unmanned aerial system at a legacy underground nuclear explosion test site and its surrounds. These data consist of visible and near-infrared wavebands over 4.3 km 2 of high desert terrain along with high spatial resolution (2.5 cm) RGB context imagery. In this work, we employ various spectral detection and classification algorithms to identify and map vegetation species in an area of interest containing the legacy test site. Here, we employed a frequentist framework for fusing multiple spectral detections across various reference spectra captured at different times and sampled from multiple locations. The spatial distribution of vegetation species is compared to the location of the underground nuclear explosion. We discover a difference in species abundance within a 130 m radius of the center of the test site.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Laser-based Sensors for Chemical Detection

Stand-off detection of hazardous materials ensures that the responder is located at a safe distance from the suspected source. Remote detection and identification of hazardous materials can be accomplished using a highly sensitive and portable device, at significant distances downwind from the source or the threat. Optical sensing methods, in particular infrared absorption spectroscopy combined with quantum cascade lasers (QCLs), are highly suited for the detection of chemical substances since they enable rapid detection and are amenable for autonomous operation in a compact and rugged package. This talk will discuss the sensor systems developed at Pacific Northwest National Laboratory and will discuss the progress to reduce the size and power while maintaining sensitivity to enable stand-off detection of multiple chemicals.

47 OTHER INSTRUMENTATION↗

X-ray imaging performance of scintillator-filled silicon pore arrays

The need for fine detail visibility in various applications such as dental imaging, mammography, but also neurology and cardiology, is the driver for intensive efforts in the development of new x-ray detectors. The spatial resolution of current scintillator layers is limited by optical diffusion. This limitation can be overcome by a pixelation, which prevents optical photons from crossing the interface between two neighboring pixels. In this work, an array of pores was etched in a silicon wafer with a pixel pitch of 50 {mu}m. A very high aspect ratio was achieved with wall thicknesses of 4-7 {mu}m and pore depths of about 400 {mu}m. Subsequently, the pores were filled with Tl-doped cesium iodide (CsI:Tl) as a scintillator in a special process, which includes powder melting and solidification of the CsI. From the sample geometry and x-ray absorption measurement the pore fill grade was determined to be 75%. The scintillator-filled samples have a circular active area of 16 mm diameter. They are coupled with an optical sensor binned to the same pixel pitch in order to measure the x-ray imaging performance. The x-ray sensitivity, i.e., the light output per absorbed x-ray dose, is found to be only 2.5%-4.5% of a commercial CsI-layer of similar thickness, thus very low. The efficiency of the pores to transport the generated light to the photodiode is estimated to be in the best case 6.5%. The modulation transfer function is 40% at 4 lp/mm and 10%-20% at 8 lp/mm. It is limited most likely by the optical gap between scintillator and sensor and by K-escape quanta. The detective quantum efficiency (DQE) is determined at different beam qualities and dose settings. The maximum DQE(0) is 0.28, while the x-ray absorption with the given thickness and fill factor is 0.57. High Swank noise is suspected to be the reason, mainly caused by optical scatter inside the CsI-filled pores. The results are compared to Monte Carlo simulations of the photon transport inside the pore array structure. In addition, some x-ray images of technical and anatomical phantoms are shown. This work shows that scintillator-filled pore arrays can provide x-ray imaging with high spatial resolution, but are not suitable in their current state for most of the applications in medical imaging, where increasing the x-ray doses cannot be tolerated.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Nonlinear registration of serial coronary CT angiography (CCTA) for assessment of changes in atherosclerotic plaque

Purpose: Coronary CT angiography (CCTA) is a high-resolution three-dimensional imaging technique for the evaluation of coronary arteries in suspected or confirmed coronary artery disease (CAD). Coregistration of serial CCTA scans would allow precise superimposition of images obtained at two different points in time, which could aid in recognition of subtle changes and precise monitoring of coronary plaque progression or regression. To this end, the authors aimed at developing a fully automatic nonlinear volume coregistration for longitudinal CCTA scan pairs. Methods: The algorithm combines global displacement and local deformation using nonlinear volume coregistration with a volume-preserving constraint. Histogram matching of intensities between two serial scans is performed prior to nonlinear coregistration with dense nonparametric local deformation in which sum of squared differences is used as a similarity measure. The approximate segmentation of coronary arteries obtained from commercially available software provides initial anatomical landmarks for the coregistration algorithm that help localize and emphasize the structure of interest. To avoid possible bias caused by incorrect segmentation, the authors convolve the Gaussian kernel with the segmented binary coronary tree mask and define an extended weighted region of interest. A multiresolution approach is employed to represent coarse-to-fine details of both volumes and the energy function is optimized using a gradient descent method. The authors applied the algorithm in ten paired CCTA datasets (20 scans in total) obtained within 10.7{+-}5.7 months from each other on a dual source CT scanner to monitor progression of CAD. Results: Serial CCTA coregistration was successful in 9/10 cases as visually confirmed. The global displacement and local deformation of target registration error obtained from four anatomical landmarks were 2.22{+-}1.15 and 1.56{+-}0.74 mm, respectively, and the inverse consistency error of local deformation was 0.14{+-}0.06 mm. The observer variability between two expert observers was 1.31{+-}0.91 mm. Conclusions: The proposed coregistration algorithm demonstrates potential to accurately register serial CCTA scans, which may allow direct comparison of calcified and noncalcified atherosclerotic plaque changes between the two scans.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Image filtering as an alternative to the application of a different reconstruction kernel in CT imaging: Feasibility study in lung cancer screening

Purpose: While the acquisition of projection data in a computed tomography (CT) scanner is generally carried out once, the projection data is often removed from the system, making further reconstruction with a different reconstruction filter impossible. The reconstruction kernel is one of the most important parameters. To have access to all the reconstructions, either prior reconstructions with multiple kernels must be performed or the projection data must be stored. Each of these requirements would increase the burden on data archiving. This study aimed to design an effective method to achieve similar image quality using an image filtering technique in the image space, instead of a reconstruction filter in the projection space for CT imaging. The authors evaluated the clinical feasibility of the proposed method in lung cancer screening. Methods: The proposed technique is essentially the same as common image filtering, which performs processing in the spatial-frequency domain with a filter function. However, the filter function was determined based on the quantitative analysis of the point spread functions (PSFs) measured in the system. The modulation transfer functions (MTFs) were derived from the PSFs, and the ratio of the MTFs was used as the filter function. Therefore, using an image reconstructed with a kernel, an image reconstructed with a different kernel was obtained by filtering, which used the ratio of the MTFs obtained for the two kernels. The performance of the method was evaluated by using routine clinical images obtained from CT screening for lung cancer in five subjects. Results: Filtered images for all combinations of three types of reconstruction kernels (''smooth,''''standard,'' and ''sharp'' kernels) showed good agreement with original reconstructed images regarded as the gold standard. On the filtered images, abnormal shadows suspected as being lung cancers were identical to those on the reconstructed images. The standard deviations (SDs) for the difference between filtered images and reconstructed images ranged from 1.9 to 23.5 Hounsfield units for all kernel combinations; these SDs were much smaller than the noise SDs in the reconstructed images. Conclusions: The proposed method has good performance and is clinically feasible in lung cancer screening. This method can be applied to images reconstructed on any scanner by measuring the PSFs in each system.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radial differential interior tomography and its image reconstruction with differentiated backprojection and projection onto convex sets

Purpose: Interior tomography has been recognized as one of the most effective approaches in computed tomography (CT) to reduce radiation dose rendered to patients. In this work, the authors propose and evaluate an imaging method of radial differential interior tomography.Methods: In interior tomography, an x-ray beam is collimated to only irradiate the region of interest (ROI) with suspected lesions while the surrounding area/volume of normal tissues/organs is spared. In the proposed imaging method of radial differential interior tomography, the outcome is a ROI image that has gone through a radial differential filtering. The image reconstruction algorithm for the radial differential interior tomography is kept in the fashion of differentiated backprojection and projection onto convex sets, but the required a priori knowledge in a small round area becomes zero and may be more readily available in practice.Results: Using the projection data simulated by computer and acquired by CT scanner, the authors evaluate and verify the performance of the proposed radial differential interior tomography method and its associated image reconstruction algorithm. The preliminary results show that the proposed imaging method can generate an image that is the radial differentiation of a conventional tomographic image and is robust over noise that inevitably exist in practice.Conclusions: It is believed that the proposed imaging method may find its utility in advanced clinical applications wherein a ROI-based image processing and analysis is required for lesion visualization, characterization, and diagnosis.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A complete software application for automatic registration of x-ray mammography and magnetic resonance images

Purpose: This work presents a complete and automatic software application to aid radiologists in breast cancer diagnosis. The application is a fully automated method that performs a complete registration of magnetic resonance (MR) images and x-ray (XR) images in both directions (from MR to XR and from XR to MR) and for both x-ray mammograms, craniocaudal (CC), and mediolateral oblique (MLO). This new approximation allows radiologists to mark points in the MR images and, without any manual intervention, it provides their corresponding points in both types of XR mammograms and vice versa. Methods: The application automatically segments magnetic resonance images and x-ray images using the C-Means method and the Otsu method, respectively. It compresses the magnetic resonance images in both directions, CC and MLO, using a biomechanical model of the breast that distinguishes the specific biomechanical behavior of each one of its three tissues (skin, fat, and glandular tissue) separately. It makes a projection of both compressions and registers them with the original XR images using affine transformations and nonrigid registration methods. Results: The application has been validated by two expert radiologists. This was carried out through a quantitative validation on 14 data sets in which the Euclidean distance between points marked by the radiologists and the corresponding points obtained by the application were measured. The results showed a mean error of 4.2 ± 1.9 mm for the MRI to CC registration, 4.8 ± 1.3 mm for the MRI to MLO registration, and 4.1 ± 1.3 mm for the CC and MLO to MRI registration. Conclusions: A complete software application that automatically registers XR and MR images of the breast has been implemented. The application permits radiologists to estimate the position of a lesion that is suspected of being a tumor in an imaging modality based on its position in another different modality with a clinically acceptable error. The results show that the application can accelerate the mammographic screening process for high risk populations or for dense breasts.

60 APPLIED LIFE SCIENCES↗

SU-D-19A-03: Monte Carlo Investigation of the Mobetron to Perform Modulated Electron Beam Therapy

Purpose: Modulated electron radiotherapy (MERT) has been proposed as a mean of delivering conformal dose to shallow tumors while sparing distal structures and surrounding tissues. In intraoperative radiotherapy (IORT) utilizing Mobetron, an applicator is placed as closely as possible to the suspected cancerous tissues to be treated. In this study we investigate the characteristics of Mobetron electron beams collimated by an in-house prospective electron multileaf collimator (eMLC) and its feasibility for MERT. Methods: IntraOp Mobetron™ dedicated to perform radiotherapy during surgery was used in the study. It provides several energies (6, 9 and 12 MeV). Dosimetry measurements were performed to obtain percentage depth dose curves (PDD) and profiles for a 10-cm diameter applicator using the PTW MP3/XS 3D-scanning system and the semiflex ion chamber. MCBEAM/MCSIM Monte Carlo codes were used for the treatment head simulation and phantom dose calculation. The design of an electron beam collimation by an eMLC attached to the Mobetron head was also investigated using Monte Carlo simulations. Isodose distributions resulting from eMLC collimated beams were compared to that collimated using cutouts. The design for our Mobetron eMLC is based on our previous experiences with eMLCs designed for clinical linear accelerators. For Mobetron the eMLC is attached to the end of a spacer-mounted rectangular applicator at 50 cm SSD. Steel will be used as the leaf material because other materials would be toxic and will not be suitable for intraoperative applications. Results: Good agreement (within 2%) was achieved between measured and calculated PDD curves and profiles for all available energies. Dose distributiosn provided by the eMLC showed reasonable agreement (∼3%/1mm) with those obtained by conventional cutouts. Conclusion: Monte Carlo simulations are capable of modeling Mobetron electron beams with a reliable accuracy. An eMLC attached to the Mobteron treatment head will allow better treatment options with those machines.

60 APPLIED LIFE SCIENCES↗

SU-E-I-30: Image Analysis in Ultrasonography for Diagnosis of Sjoegren's Syndrome Using Dual-Tree Complex Wavelet Transform

Purpose: Sjoegren's syndrome (SS) is an autoimmune disease invading mainly salivary and lacrimal glands. Ultrasonography is used for an initial and non-invasive examination of this disease. However, the ultrasonography diagnosis tends to lack in objectivity and depends on the operator's skills. The purpose of this study is to propose a computer-aided diagnosis (CAD) system for SS based on a dual-tree complex wavelet transform (DT-CWT) and machine learning. Methods: The subjects of this study were 174 patients suspected of having SS at Nagasaki University Hospital and examined with ultrasonography of the parotid glands. Out of these patients, 77 patients were diagnosed with SS by sialography. A region of interest (ROI) of 128 × 128 pixels was set within the parotid gland that was indicated by a dental radiologist. The DT-CWT was applied to the images in the ROI and every image was decomposed into 72 sub-images of the real and imaginary components in six different resolution levels and six orientations. The statistical features of the sub-image were calculated and used as data input for the support vector machine (SVM) classifier for the detection of SS. A ten-fold cross-validation was employed to verify the Resultof SVM. The accuracy of diagnosis was compared by a CAD system with a human observer performance. Results: The sensitivity, specificity, and accuracy in the detection of SS were 95%, 86%, and 91% through our CAD system respectively, while those by a human observer were 84%, 81%, and 83% respectively. Conclusion: The proposed computer-aided diagnosis system for Sjoegren's syndrome in ultrasonography based on dual-tree complex wavelet transform had a better performance than a human observer.

60 APPLIED LIFE SCIENCES↗