Thermal activation parameters of plastic flow reveal deformation mechanisms in the CrMnFeCoNi high-entropy alloy

To reveal the operating mechanisms of plastic deformation in an FCC high-entropy alloy, the activation volumes in CrMnFeCoNi have been measured as a function of plastic strain and temperature between 77 K and 423 K using repeated load relaxation experiments. At the yield stress, σ y , the activation volume varies from ~60 b3 at 77 K to ~360 b 3 at 293 K and scales inversely with yield stress. With increasing plastic strain, the activation volume decreases and the trends follow the Cottrell-Stokes law, according to which the inverse activation volume should increase linearly with σ - σ y (Haasen plot). This is consistent with the notion that hardening due to an increase in the density of forest dislocations is naturally associated with a decrease in the activation volume because the spacing between dislocations decreases. The values and trends in activation volume agree with theoretical predictions that treat the HEA as a high-concentration solid-solution-strengthened alloy. Lastly, these results demonstrate that this HEA deforms by the mechanisms typical of solute strengthening in FCC alloys, and thus indicate that the high compositional/structural complexity does not introduce any new intrinsic deformation mechanisms.

36 MATERIALS SCIENCE↗

Multiscale mechanical fatigue damage of stainless steel investigated by neutron diffraction and X-ray microdiffraction

Mechanical fatigue behavior of AL6XN stainless steel as a typical type of planar slip alloy was investigated by in situ neutron diffraction and synchrotron-based X-ray microdiffraction methods. Under cyclic loading at a high strain amplitude (+/- 0.8%), the fatigue damage originated mainly from the accumulation of statistical stored dislocations, as clearly evidenced from a continuous increase in diffraction peak width with increasing the number of load cycles. However, under cyclic loading at a low strain amplitude (+/- 0.3%), the density of statistical stored dislocations became saturated just after a hundred loading cycles and the fatigue damage was mainly dominated by the accumulation of persistent [Alders bands (PLBs) and the complex interactions among various PLBs as evidenced through X-ray microdiffraction measurements. It was further found that there exists obvious grain-orientation-dependent local damage in the low-strain-amplitude fatigued sample. In particular, fatigued grains orientated with [001] paralleling the loading direction are subjected to compressive stress and contain a large number of broad PLBs in boundaries arraying the edge dislocation pile-ups, which generate a large stress gradient leading to local plastic instability. As a result, the highly localized stress field at PLBs in the cyclically-deformed sample at a low strain amplitude may explain the obvious cyclic stress softening.

36 MATERIALS SCIENCE↗

A non-melting additive approach to structural repair of aluminum aircraft fastener holes

The damage to fastener holes in aerospace aluminum structures presents significant challenges for aircraft durability, and conventional bushing methods for repairing oversized holes often fall short due to the lack of metallurgical bonding and limited edge distance availability. This study investigates additive friction stir deposition, a non-melting additive process, as a viable alternative for the structural repair of aerospace fastener holes. The repair process, demonstrated on AA7050 (Al-Zn-Mg-Cu-Zr) hole structures, involves filling oversized holes with new material and machining to restore the original hole size. The repaired hole coupons are defect-free and exhibit good fatigue performance under fully reversed tension-compression loading (R = -1). At a nominal stress amplitude of 123.5 MPa, the average number of cycles to failure is 12,666 for unrepaired baseline coupons and 17,372 for effectively repaired coupons. Restoring complex geometries without compromising fatigue performance has been difficult in aerospace applications; this study marks the first demonstration of additive repair that consistently outperforms the unrepaired baseline coupons. Notably, the result is achieved through a low-energy, cost-effective solution without the need for post-repair heat treatment. Except for a few outliers, the post-repair fatigue performance generally remains inferior to that of undamaged, pristine coupons, likely due to precipitate evolution in AA7050 caused by the thermomechanical processing nature of additive friction stir deposition. This evolution weakens the repair region and the adjacent base material, leading to faster crack initiation and growth compared to the properly aged base material, AA7050-T7451.

36 MATERIALS SCIENCE↗

Innovations in underground hydrogen storage with multiphysics simulations, optimization, and monitoring: A review

Underground Hydrogen Storage (UHS) is a promising solution for large-scale energy storage and a critical component in advancing low-carbon energy system. Ensuring the safety and efficiency of UHS necessitates a comprehensive understanding of multiphysical interactions driven by cyclic pore fluid pressure fluctuations and coupled physicochemical processes. Here, this review examines the key geomechanical responses in UHS, including rock property variations under cyclic loading, fracture evolution and propagation, reservoir stress sensitivity, and fault stability. It also explores the impact of geochemical and microbial reactions on geomechanical characteristics. We provide an in-depth analysis of Thermal-Hydraulic-Mechanical-Chemical (THMC) coupled numerical simulations, highlighting their potential for future multi-scale modeling. Limitations of current machine learning (ML) approaches in addressing UHS challenges are highlighted, emphasizing the need for innovative ML-based methodologies. Operational strategies for hydrogen injection and production are reviewed, focusing on safety, efficiency, and economic viability. The necessity for multi-objective optimization (MOO) to balance storage efficiency, risk mitigation, and cost-effectiveness is also discussed. Current monitoring technologies are evaluated to ensure safe and efficient UHS operations. Finally, this review identifies critical knowledge gaps and underscores the importance of advancing geomechanical understanding under multiphysics-coupling. We highlight the need for ML-driven multiphysics theories, enhanced modeling techniques, and robust optimization strategies to improve UHS performance. This study serves as a comprehensive reference for future research and the large-scale implementation of UHS systems.

25 ENERGY STORAGE↗

Recent research and development for the dual-coolant blanket concept in the US

The dual-coolant lead-lithium, or DCLL, blanket concept is of strong interest in the US fusion technology program. In the DCLL blanket, the flow channel insert (FCI) is a critical component. FCIs must have low electrical and thermal conductivity and be compatible with lead-lithium eutectic alloy (Pb-17Li) at elevated temperatures. FCIs must retain structural integrity and desirable properties even under irradiation and large temperature gradients during operation. FCIs must not fail in such a way that Pb-17Li enters the FCI and changes its electrical or thermal conductivity significantly. Another important issue for the DCLL is the development of a suitable tritium extraction from the Pb-17Li to achieve low tritium partial pressure, thus facilitating decisive tritium control. In this paper, the state of DCLL development in the US is presented including recent design modifications and results from recent R&D efforts. Such R&D includes the progress on development and property quantification of SiC/SiC composites and SiC foams as candidate FCI materials; Pb-17Li material capability and infiltration studies; simulations of MHD Pb-17Li flow characteristics and of resultant temperature distributions; and the analysis of FCI stress states based on these thermal loads. In addition, tritium extraction from Pb-17Li based on a vacuum permeator concept is shown to have the potential to achieve the desired tritium control. A discussion of DCLL optimization and unresolved DCLL issues and future R&D needs is also presented.

Morley, Neil B↗

Learning constitutive relations using symmetric positive definite neural networks

In this work, we present a new neural-network architecture, called the Cholesky-factored symmetric positive definite neural network (SPD-NN), for modeling constitutive relations in computational mechanics. Instead of directly predicting the stress of the material, the SPD-NN trains a neural network to predict the Cholesky factor of the tangent stiffness matrix, based on which the stress is calculated in incremental form. As a result of this special structure, SPD-NN weakly imposes convexity on the strain energy function, satisfies the second order work criterion (Hill's criterion) and time consistency for path-dependent materials, and therefore improves numerical stability, especially when the SPD-NN is used in finite element simulations. Depending on the types of available data, we propose two training methods, namely direct training for strain and stress pairs and indirect training for loads and displacement pairs. We demonstrate the effectiveness of SPD-NN on hyperelastic, elasto-plastic, and multiscale fiber-reinforced plate problems from solid mechanics. The generality and robustness of SPD-NN make it a promising tool for a wide range of constitutive modeling applications.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Biocompatible Co–P Metallic Glasses with Superior Degradation Tolerance in Physiological Environments

Metallic glasses represent a class of metallic alloys with a fully amorphous structure and attractive properties, making them promising in bioimplant applications. Here, the degradation tolerance of biocompatible cobalt–phosphorus (Co–P) metallic glasses was studied in a simulated physiological environment. The metallic glasses were synthesized in the form of coatings through a facile electrodeposition approach. This method utilizes their outstanding surface characteristics and bypasses the size limitations usually associated with their bulk counterparts. Further, the Co–P alloys showed exceptional tribological response with ~14% lower coefficient of friction and 2 orders of magnitude lesser wear rate compared to SS316 stainless steel. In addition, the Co–P alloys showed a 3 times higher hardness and 4 times higher hardness/modulus ratio compared to SS316, indicating better elastic recovery under dynamic shear stresses that are common in load-bearing bioimplants. The Co–P metallic glasses exhibited excellent hemocompatibility and cytocompatibility in terms of lower platelet adhesion, spreading, and aggregation, a hemolysis ratio lower than 1%, and enhanced surface wettability, suggesting a superlative performance in bioimplant applications.

36 MATERIALS SCIENCE↗

Magnetic and elastic anisotropy in magnetorheological elastomers using nickel-based nanoparticles and nanochains

Nickel (Ni) based nanoparticles and nanochains were incorporated as fillers in polydimethylsiloxane (PDMS) elastomers and then these mixtures were thermally cured in the presence of a uniform magnetic field. In this way, macroscopically structured-anisotropic PDMS-Ni based magnetorheological composites were obtained with the formation of pseudo-chains-like structures (referred as needles) oriented in the direction of the applied magnetic field when curing. Nanoparticles were synthesized at room temperature, under air ambient atmosphere (open air, atmospheric pressure) and then calcined at 400 °C (in air atmosphere also). The size distribution was obtained by fitting Small Angle X-ray Scattering (SAXS) experiments with a polydisperse hard spheres model and a Schulz-Zimm distribution, obtaining a size distribution centered at (10.0 ± 0.6) nm with polydispersivity given by σ = (8.0 ± 0.2) nm. The SAXS, X-ray powder diffraction, and Transmission Electron Microscope (TEM) experiments are consistent with single crystal nanoparticles of spherical shape (average particle diameter obtained by TEM: (12 ± 1) nm). Nickel-based nanochains (average diameter: 360 nm; average length: 3 μm, obtained by Scanning Electron Microscopy; aspect ratio = length/diameter ∼ 10) were obtained at 85 °C and ambient atmosphere (open air, atmospheric pressure). The magnetic properties of Ni-based nanoparticles and nanochains at room temperature are compared and discussed in terms of surface and size effects. Both Ni-based nanoparticles and nanochains were used as fillers for obtaining the PDMS structured magnetorheological composites, observing the presence of oriented needles. Magnetization curves, ferromagnetic resonance (FMR) spectra, and strain-stress curves of low filler's loading composites (2% w/w of fillers) were determined as functions of the relative orientation with respect to the needles. The results indicate that even at low loadings it is possible to obtain magnetorheological composites with anisotropic properties, with larger anisotropy when using nanochains. For instance, the magnetic remanence, the FMR field, and the elastic response to compression are higher when measured parallel to the needles (about 30% with nanochains as fillers). Analogously, the elastic response is also anisotropic, with larger anisotropy when using nanochains as fillers. Therefore, all experiments performed confirm the high potential of nickel nanochains to induce anisotropic effects in magnetorheological materials.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Crimping-induced structural gradients explain the lasting strength of poly L -lactide bioresorbable vascular scaffolds during hydrolysis

Biodegradable polymers open the way to treatment of heart disease using transient implants (bioresorbable vascular scaffolds, BVSs) that overcome the most serious complication associated with permanent metal stents—late stent thrombosis. Here, we address the long-standing paradox that the clinically approved BVS maintains its radial strength even after 9 mo of hydrolysis, which induces a ~40% decrease in the poly L-lactide molecular weight (Mn). X-ray microdiffraction evidence of nonuniform hydrolysis in the scaffold reveals that regions subjected to tensile stress during crimping develop a microstructure that provides strength and resists hydrolysis. These beneficial morphological changes occur where they are needed most—where stress is localized when a radial load is placed on the scaffold. We hypothesize that the observed decrease in Mn reflects the majority of the material, which is undeformed during crimping. Thus, the global measures of degradation may be decoupled from the localized, degradation-resistant regions that confer the ability to support the artery for the first several months after implantation.

59 BASIC BIOLOGICAL SCIENCES↗

Characterizing the effect of incrementally increasing dry bulb temperature on linear and nonlinear measures of heart rate variability in nonpregnant, mid-gestation, and late-gestation sows

Abstract Characterizing the sow physiological response to an increased heat load is essential for effective heat stress mitigation. The study objective was to characterize the effects of a 400-min heating episode on sow heart rate variability (HRV) at different reproductive stages. HRV is a commonly used noninvasive proxy measure of autonomic function. Twenty-seven sows were enrolled in the study according to their gestation stage at time of selection: 1) nonpregnant (NP; n = 7), 2) mid-gestation (MID; 57.3 ± 11.8 d gestation; n = 11), and 3) late-gestation (LATE; 98.8 ± 4.9 d gestation; n = 8). The HRV data utilized in the study were collected from each pig as the dry bulb temperature in the room increased incrementally from 19.84 ± 2.15 °C to 35.54 ± 0.43 °C (range: 17.1–37.5 °C) over a 400-min period. After data collection, one 5-min set of continuous heart rate data were identified per pig for each of nine temperature intervals (19–20.99, 21–22.99, 23–24.99, 25–26.99, 27–28.99, 29–30.99, 31–32.99, 33–34.99, and 35–36.99 °C). Mean inter-beat interval length (RR), standard deviation of r-r intervals (SDNN), root mean square of successive differences (RMSSD), high frequency spectral power (HF), sample entropy (SampEn), short-term detrended fluctuation analysis (DFAα1), and three measures (%REC, DET, LMEAN) derived from recurrence quantification analysis were calculated for each data set. All data were analyzed using the PROC GLIMMIX procedure in SAS 9.4. Overall, LATE sows exhibited lower RR than NP sows (P < 0.01). The standard deviation of r–r intervals and RMSSD differed between each group (P < 0.01), with LATE sows exhibiting the lowest SDNN and RMSSD and NP sows exhibiting the greatest SDNN and RMSSD. Late-gestation sows exhibited lower HF than both MID and NP sows (P < 0.0001), greater DFA values than NP sows (P = 0.05), and greater DET compared to MID sows (P = 0.001). Late-gestation also sows exhibited greater %REC and LMEAN compared to MID (P < 0.01) and NP sows (all P < 0.01). In conclusion, LATE sows exhibited indicators of greater autonomic stress throughout the heating period compared to MID and NP sows. However, temperature by treatment interactions were not detected as dry bulb increased. Future studies are needed to fully elucidate the effect of gestational stage and increasing dry bulb temperature on sow HRV.

Agriculture↗

Techno-Economic Analysis for the Addition of a Thermal Energy Storage System to a Central Plant

Increasing energy demand and rising peak loads present significant challenges for energy management in commercial and institutional settings. As climate change drives greater cooling needs, central plants must navigate the complex tradeoffs between operational efficiency, cost control, and grid stability. Thermal energy storage (TES) systems offer a viable solution by shifting energy consumption from peak to off-peak periods, thereby reducing peak demand, lowering utility expenses, and improving grid resilience. However, the success of TES implementation hinges on appropriate system sizing, effective control strategies, and alignment with local utility rate structures. This article presents a techno-economic analysis of integrating a chilled water TES system into the central plant at California State University, Dominguez Hills. Drawing on historical load profiles and utility tariffs, we assess three TES sizing approaches and their corresponding control strategies from both energy and economic perspectives. This article utilizes a model-based approach to assess the impact of TES sizing and control strategies on the techno-economic feasibility of integrating TES into an existing central plant. The models employed for this analysis were calibrated using 4 years of historical data. Here, the results demonstrated that utility tariffs and the campus's operational profiles dictate the most feasible sizing and control methods. The findings offer valuable insights for institutions and commercial building managers exploring sustainable energy solutions. By demonstrating how optimized TES strategies can improve operational efficiency while achieving financial savings, this study highlights the potential for TES to align performance with cost effectiveness in real-world applications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Techno-Economic Analysis for the Addition of Thermal Energy Storage to a Campus With Existing Battery Storage

Rising global temperatures and increasing energy demands pose significant challenges for energy management, particularly in institutional and commercial settings. As cooling needs grow, campuses must balance operational efficiency, cost control, and grid stability. Energy storage solutions, such as thermal energy storage (TES) systems, offer a promising approach to shifting energy consumption from peak to off-peak periods, alleviating peak demand, reducing utility costs, and enhancing grid resilience. When integrated with existing battery energy storage systems (BESS), TES can further optimize load management and improve energy savings, especially in buildings with diverse energy needs. This article presents a techno-economic analysis of integrating a chilled water TES system into the central plant at California State University, Dominguez Hills, which already operates a BESS. We assess three TES sizing strategies—full storage, load leveling, and peak demand limiting—by modeling and simulations based on historical energy loads. Our findings show that we can control TES systems to complement BESS operation, with campus-level load leveling providing the greatest cost savings by reducing peak demands. Furthermore, the study also evaluates the long-term economic viability of TES, considering installation costs, energy savings, and payback periods under varying tariffs. This research offers practical guidance for institutions seeking to enhance energy resilience and reduce operational costs through energy storage solutions.

25 ENERGY STORAGE↗

Load Mitigation on Floating Offshore Wind Turbines with Advanced Controls and Tuned Mass Dampers

General Electric, the National Renewable Energy Laboratory (NREL), the University of Massachusetts Amherst (UMass), and Glosten have recently completed a US Department of Energy (DOE)-funded research program to study technologies for mitigating loads on floating offshore wind turbines through the use of advanced turbine controls and tuned mass dampers (TMDs). The analysis was based upon the Glosten PelaStar tension leg platform (TLP) with GE Haliade 150 turbine, a system developed in a previous front end engineering design (FEED) study funded by the Energy Technology Institute (ETI) in the UK. The platform was designed for the WaveHub wave energy research site, with a mean water depth of 59-m. Loads were analyzed by running time-domain simulations in four 50-year return period (50-YRP) ultimate load state (ULS) conditions and 77 fatigue load state (FLS) environmental conditions. In 50-YRP conditions advanced controls are not active. The influence of TMDs on ULS loads have been reported previously (Park et al. [2]). In FLS conditions advanced controls and TMDs afford dramatic reductions in fatigue damage, offering the potential of significant savings in tower structural requirements. Simulations in turbine idling conditions were run in OrcaFlex, and simulations in operating conditions were run in FAST. Simulations were run with a baseline turbine controller, representative of the current state of the art, and an advanced controller developed by NREL to use collective and individual blade pitch control to maintain rotor speed and reduce tower loads. UMass developed a number of TMD types, with varying system configurations, including passive nonlinear dampers and semi-actively controlled dampers with an inverse velocity groundhook control algorithm. Loads and accelerations in FLS conditions were evaluated on the basis of damage equivalent loads (DELs), and fatigue damage was computed by Miner's summations of stress cycles at the tower base. To study sensitivity to water depth, loads were analyzed at both the 59-m WaveHub depth and a more commercially realistic depth of 100 m. TMDs reduce fatigue damage at the tower-column interface flange by up to 52% in 59-m water depth and up to 28% in 100 m water depth. Advanced controls reduce fatigue damage at the tower-column flange by up to 22% in 59-m water depth and up to 40% in 100 m water depth. The most effective load-mitigation strategy is combining advanced controls with TMDs. This strategy affords a 71% reduction in fatigue damage in both 59-m and 100-m water depths.

17 WIND ENERGY↗

Investigating the Particle Growth in Bimodal Pt/C Catalysts by In-Situ Small-Angle X-ray Scattering: Challenges in the Evaluation of Stress Test Protocol-Dependent Degradation Mechanisms

The influence of different combinations of accelerated stress test (AST) protocols simulating load-cycle and start/stop conditions of a proton exchange membrane fuel cell (PEMFC) vehicle is investigated on a bimodal Pt/C catalyst. The bimodal Pt/C catalyst, prepared by mixing two commercial catalysts, serves as a model system and consists of two distinguishable size populations. The change in mean particle size was investigated by in situ small-angle X-ray scattering (SAXS). The comparison to the reference catalysts, i.e., the two single-size population catalysts, uncovers the presence of electrochemical Ostwald ripening as a degradation mechanism in the bimodal catalyst. Increasing the harshness of the applied AST protocol combinations by faster changing between load-cycle or start/stop conditions, the particle size of the larger population of the bimodal catalyst increases faster than expected. Surprisingly, the change in mean particle size of the smaller size population indicates a smaller increase for harsher AST protocols, which might be explained by a substantial electrochemical Ostwald ripening.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Utah FORGE: Fault Shear Reactivation Experimental Data for Fluid Injection-Rate Controls on Seismic Moment

Included are experimental data recorded from shear experiments that specifically explore the link between fluid-injection rate and seismic moment resulting from shear reactivation of laboratory faults. Raw mechanical data from three experiments are included alongside corresponding MATLAB scripts that import and plot the data, as well as use it to calculate shear and normal stress. Experiments are performed on 2.5-3 inch long granitoid cores from the Utah FORGE EGS demonstration site, containing a single inclined fracture with small-scale roughness added to the fracture surface. The raw data included here were recorded from an aluminum triaxial pressure vessel (TEMCO) configured with three independent servo-controlled pumps, with distilled water used as the working fluid. The pumps control confining pressure, upstream pore pressure, and axial pressure, with each pump connected to a LabView interface to record applied pressures, cumulative injected water volumes, and pump flow rates. The downstream outlet from the fracture is closed to allow pressurization, which is measured by an external pressure transducer. A linear variable differential transformer (LVDT) attached to the axial piston measures axial displacement, from which we calculate shear displacement along the fracture. Additionally, P-wave transducers are used to record acoustic signatures, where acoustic emission events and maximum amplitudes are compared against seismic moment and shear slip velocity. Fluid injection rates range between 0.05 mL/min, 0.25 mL/min, and 0.75 mL/min for each experiment. Along-fault pressure distributions are progressively less uniform as injection rates increase, representing a switch from steady-state to transient conditions. Triggered shear displacement is used as a proxy for seismic moment and is indexed against cumulative injection volume and rate. Each experiment is performed under constant shear stress conditions, and the sample is fully saturated with DI water. Axial and confining stresses are applied to 3 MPa through pressure-stepping in 500 kPa increments. The pore pressure is held constant at 200 kPa prior to initiating the experiment, and initial axial displacement is recorded. The axial stress is then increased to initiate shear mobilization during the loading phase (run-in) until a peak steady state is achieved. The initial shear stress is reduced to approximately 80% of the peak shear stress by decreasing the axial stress, then held constant for the duration of each experiment.

15 GEOTHERMAL ENERGY↗

Online stress corrosion crack and fatigue usages factor monitoring and prognostics in light water reactor components: Probabilistic modeling, system identification and data fusion based big data analytics approach

Nuclear reactors in the United States account for roughly 20% of the nation's total electric energy generation, and maintaining their safety in regards to key component structural integrity is critical not only for long term use of such plants but also for the safety of personnel and the public living around the plant. Early detection of damage signature such as of stress corrosion cracking, thermal-mechanical loading related material degradation in safety-critical components is a necessary requirement for long-term and safe operation of nuclear power plant systems.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗