Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SPECTROMETERS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Mass Spectrometer for Airborne Micro-Organisms

Bacteria and other micro-organisms identified continously with aid of new technique for producing samples for mass spectrometer. Technique generates aerosol of organisms and feeds to spectrometer. Given species of organism produces characteristic set of peaks in mass spectrum and thereby identified. Technique useful for monitoring bacterial makeup in environmental studies and in places where cleanliness is essential, such as hospital operating rooms, breweries, and pharmaceutical plants.

Sinha, M. P.↗

A cometary ion mass spectrometer

The development of flight suitable analyzer units for that part of the GIOTTO Ion Mass Spectrometer (IMS) experiment designated the High Energy Range Spectrometer (HERS) is discussed. Topics covered include: design of the total ion-optical system for the HERS analyzer; the preparation of the design of analyzing magnet; the evaluation of microchannel plate detectors and associated two-dimensional anode arrays; and the fabrication and evaluation of two flight-suitable units of the complete ion-optical analyzer system including two-dimensional imaging detectors and associated image encoding electronics.

Shelley, E. G.↗

Application of Fabry-perot Spectrometers for Measurement of Upper Atmosphere Temperatures and Winds

The mechanisms giving rise to certain airglow and auroral emissions and their height distribution are briefly surveyed. The basic principles of operation of scanning Fabry-Perot spectrometers are outlined in order to illustrate the calibration and use of such instruments to measure Doppler broadening and shift of atomic emission lines in the spectrum of the airglow and aurora and hence to infer atmospheric temperatures and wind velocities. Technical details of some specific instruments are given. Brief mention is made of the use of wide angle Michelson interferometers for the same application. Emphasis is given to the future importance of imaging Fabry-Perot spectrometers to permit the detailed mapping of temperature and wind velocity, especially in the auroral regions.

F Jacka↗

A 150 Micron Heterodyne Spectrometer for Airborne Astronomy

The advantages of heterodyne detection for high resolution spectroscopy were long known to radio astronomers. Heterodyne spectroscopy was productive at submillimeter wavelengths, but its extension to shorter submillimeter and far-infrared (FIR) wavelengths was hampered by inadequate mixers and local oscillators. A significant advance in FIR receiver technology was demonstrated using an optically-pumped FIR laser and a Schottky-diode mixer. Any similar spectrometer intended for airborne observations at shorter wavelengths must be compatible with the more restrictive aircraft environment. The effectiveness of the design of a FIR heterodyne spectrometer was verified in ground-based observations with a prototype version. The airborne successor is even more compact, and has a much broader spectral coverage. Flight tests are scheduled for the new instrument.

Betz, A.↗

Geometric error analysis for shuttle imaging spectrometer experiment

The demand of more powerful tools for remote sensing and management of earth resources steadily increased over the last decade. With the recent advancement of area array detectors, high resolution multichannel imaging spectrometers can be realistically constructed. The error analysis study for the Shuttle Imaging Spectrometer Experiment system is documented for the purpose of providing information for design, tradeoff, and performance prediction. Error sources including the Shuttle attitude determination and control system, instrument pointing and misalignment, disturbances, ephemeris, Earth rotation, etc., were investigated. Geometric error mapping functions were developed, characterized, and illustrated extensively with tables and charts. Selected ground patterns and the corresponding image distortions were generated for direct visual inspection of how the various error sources affect the appearance of the ground object images.

Wang, S. J.↗

A retarding ion mass spectrometer for the Dynamics Explorer-1

The Retarding Ion Mass Spectrometer (RIMS) for Dynamics Explorer-1 is an instrument designed to measure the details of the thermal plasma distribution. It combines the ion temperature determining capability of the retarding potential analyzer with the compositional capabilities of the mass spectrometer and adds multiple sensor heads to sample all directions relative to the spacecraft ram direction. This manual provides a functional description of the RIMS, the instrument calibration, and a description of the commands which can be stored in the instrument logic to control its operation.

Wright, W.↗

Results of a search for deuterium at 25-50 GC/c using a magnetic spectrometer

A method is presented for separately identifying isotopes using a Cerenkov detector and a magnet spectrometer. Simulations of the method are given for separating deuterium from protons. The simulations are compared with data gathered from the 1979 flight of the New Mexico State University balloonborne magnet spectrometer. The simulation and the data show the same general characteristics lending credence to the technique. The data show an apparent deuteron signal which is (11 + or - 3)% of the total sample in the rigidity region 38.5 to 50 GV/c. Until further background analysis and subtraction is performed this should be regarded as an upper limit to the deuteron/(deuteron+proton) ratio.

Golden, R. L.↗

The Gamma-Ray Imaging Spectrometer (GRIS): A new balloon-borne experiment for gamma-ray line astronomy

High resolution gamma-ray spectroscopy is a relatively new field that holds great promise for further understanding of high energy astrophysical processes. When the high resolution gamma-ray spectrometer (GRSE) was removed from the GRO payload, a balloon program was initiated to permit continued development and improvement of instrumentation in this field, as well as continued scientific observations. The Gamma-Ray Imaging Spectrometer (GRIS) is one of the experiments selected as part of this program. The instrument contains a number of new and innovative features that are expected to produce a significant improvement in source location accuracy and sensitivity over previous balloon and satellite experiments.

Teegarden, B. J.↗

Noiseless coding for the Gamma Ray spectrometer

The payload of several future unmanned space missions will include a sophisticated gamma ray spectrometer. Severely constrained data rates during certain portions of these missions could limit the possible science return from this instrument. This report investigates the application of universal noiseless coding techniques to represent gamma ray spectrometer data more efficiently without any loss in data integrity. Performance results demonstrate compression factors from 2.5:1 to 20:1 in comparison to a standard representation. Feasibility was also demonstrated by implementing a microprocessor breadboard coder/decoder using an Intel 8086 processor.

Rice, R.↗

The Nagoya cosmic-ray muon spectrometer 3, part 1: Preliminary observations

There are some discrepancies among the data of absolute muon intensities at large zenth angles. Through the analysis of the data obtained in the previous measurement by Nagoya Cosmic Ray Spectrometer, one of the sources of these discrepancies has been found to be the ambiguity induced by the selection criteria with which genuine muons are distinguished from the backgrounds. To remove the ambiguity of this kind, it is necessary to know the amount of the backgrounds and their characteristics in detail. Some features of the background events were reported from the observations by using this triggering system of Nagoya Cosmic Ray Spectrometer. In this paper, the results of extended observations using track detector together with this system are reported.

Kamiya, Y.↗

The Nagoya cosmic-ray muon spectrometer 3, part 2: Track detector

The twelve wide gap spark chambers were utilized as the track detectors of the Nagoya cosmic-ray muon spectrometer not only to obtain the precise locations of particles, but also to get some information about the correspondences between segments of trajectories. The area of each chamber is 150 x 70 sq cm and the width of a gap is 5 cm. The gas used is He at the atmospheric pressure. Each three pairs of them are placed on both sides of the deflection magnet. All images of sparks for each event are projected through the mirror system and recorded by two cameras stereoscopically. The mean detection efficiency of each chamber is 95 + or - 2% and the spacial resolution (jitter and drift) obtained from the prototype-experiment is 0.12 mm. Maximum detectable momentum of the spectrometer is estimated at about 10 TeV/c taking into account these characteristics together with the effects of the energy loss and multiple Coulomb scattering of muons in the iron magnet.

Shibata, S.↗

An FIR cooled grating spectrometer for the Kuiper Airborne Observatory

The design and performance of a liquid-He-cooled spectrometer being developed for the Kuiper Airborne Observatory (KAO) to study FIR lines originating in the interstellar medium are discussed. Currently, the spectrometer contains six Ge:Ga photoconductor detectors mounted in integrating cavities and cooled to about 3 K; the collimator focal plane has space for 39 such detectors. The instrument achieves a maximum resolving power of 6000 by means of a 45-cm long echelle grating and is optically capable of operating in the spectral range 25-300 microns. A laboratory spectrum of water vapor, an atmospheric water absorption feature measured from the KAO with Mars as a source, and the forbidden O(2+) emission from W51-IRS1 are shown.

Erickson, E. F.↗

A Shuttle Imaging Spectrometer Experiment for the late 1980's

The Shuttle Imaging Spectrometer Experiment (SISEX), proposed as a next experimental step in the development of advanced earth remote sensing technology, is capable of imaging the earth's surface simultaneously in 128 spectral bands covering the range from 0.4 to 2.5 micrometers. Laboratory and field measurements have suggested the utility of high-spectral-resolution remote sensing, and an aircraft-borne precursor to the SISEX has demonstrated the ability to distinguish among differing vegetation and rock types - in certain cases making unique identifications. The SISEX instrument utilizes an area-array focal plane, populated by visual- and infrared-sensitive detectors, to acquire simultaneous spatial and spectral information on a line-by-line basis. The spectrum is dispersed by means of a prism spectrometer. The performance analysis indicates that the scientific requirements for radiometric precision can be achieved using optics with an effective circular aperture of 11 cm.

Wellman, J. B.↗

Fabrication of optical components for the ultraviolet spectrometer and polarimeter on the Solar Maximum Mission

The Solar Maximum Mission (SMM) satellite was launched in February 1980 into a 573 km high circular orbit. It contains X-ray, UV, and optical instruments for the simultaneous observation of solar flares. The ultraviolet spectrometer and polarimeter (UVSP) is one of these instruments. The objectives of the UVSP require the employment of a raster scanning telescope to study the spatial dynamics of flares, the use of a high resolution spectrometer to select and scan spectral lines for temperature and velocity diagnostics, and the utilization of a polarimeter to measure magnetic fields in the solar transition zone. The present paper has the objective to provide a description of the optical fabrication techniques developed for the instrument. Attention is given to telescope mirrors, metering rods, the Ebert mirror, grating blanks, a four-mirror polarizer, beam splitter assemblies, beam splitter fabrication, deflector mirrors, and shipping containers.

Spencer, R. S.↗

The geomagnetic mass spectrometer - Mass and energy dispersions of ionospheric ion flows into the magnetosphere

Observations of ion flows in the polar magnetosphere, made by the retarding ion mass spectrometer on NASA's Dynamics Explorer (DE) 1, are compared with those made simultaneously in the topside ionosphere by the ion drift meter on the lower-altitude DE 2 spacecraft. The results show the dayside auroral ionosphere to be a significant and highly persistent source of plasma for the magnetosphere. The upwelling ionospheric ions are spatially dispersed, according to both their energy and mass, by the combined actions of the geomagnetic field and the dawn-to-dusk convection electric field, in an effect analogous to the operation of an ion mass spectrometer.

Lockwood, M.↗

Measurements of (C-12)H4 nu-4 band halfwidths using a tunable diode laser system and a Fourier transform spectrometer

Air-broadened and N2-broadened halfwidths at room temperature for twenty-five transitions in the nu-4 fundamental band of (C-12)H4 have been determined from IR absorption spectra recorded with a tunable diode laser spectrometer. Two tunable diode lasers operating in the 1250-1380-kayser region were used to obtain these data. Air-broadened halfwidths for twenty of these lines were also determined from additional spectra recorded at 0.01-kayser resolution with the Fourier transform spectrometer in the McMath solar telescope complex on Kitt Peak. The air-broadened halfwidths obtained from these two techniques are very consistent with agreement better than 3 percent in most cases.

Devi, V. M.↗

Improved Spectrometer for Field Use

Proposed portable spectrometer for analyzing minerals in field generates spectral images like camera and process spectral data for real-time identification of materials. To identify unknown mineral, user locates significant peaks in displayed spectrum and matches them to spectrum in portfolio of reference spectra. Alternatively, user calls up display of prerecorded spectra in same wavelength region for comparison or allows spectrometer to determine best match automatically. New instrument makes it unnecessary to return data to laboratory or equipment trailer for processing.

Goetz, A. F. H.↗

Proceedings of the Airborne Imaging Spectrometer Data Analysis Workshop

The Airborne Imaging Spectrometer (AIS) Data Analysis Workshop was held at the Jet Propulsion Laboratory on April 8 to 10, 1985. It was attended by 92 people who heard reports on 30 investigations currently under way using AIS data that have been collected over the past two years. Written summaries of 27 of the presentations are in these Proceedings. Many of the results presented at the Workshop are preliminary because most investigators have been working with this fundamentally new type of data for only a relatively short time. Nevertheless, several conclusions can be drawn from the Workshop presentations concerning the value of imaging spectrometry to Earth remote sensing. First, work with AIS has shown that direct identification of minerals through high spectral resolution imaging is a reality for a wide range of materials and geological settings. Second, there are strong indications that high spectral resolution remote sensing will enhance the ability to map vegetation species. There are also good indications that imaging spectrometry will be useful for biochemical studies of vegetation. Finally, there are a number of new data analysis techniques under development which should lead to more efficient and complete information extraction from imaging spectrometer data. The results of the Workshop indicate that as experience is gained with this new class of data, and as new analysis methodologies are developed and applied, the value of imaging spectrometry should increase.

Vane, G.↗