Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SHUNT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

The Wakefield Effects of Pulsed Crab Cavities at the Advanced Photon Source for Short-X-ray Pulse Generation

In recent years we have explored the application to the Advanced Photon Source (APS) of Zholents' crab-cavity based scheme for production of short x-ray pulses. As a near-term project, the APS has elected to pursue a pulsed system using room-temperature cavities. The cavity design has been optimized to heavily damp parasitic modes while maintaining large shunt impedance for the deflecting dipole mode. We evaluated a system consisting of three crab cavities as an impedance source and determined their effect on the single- and multi-bunch instabilities. In the single-bunch instability we used the APS impedance model as the reference system in order to predict the overall performance of the ring when the crab cavities are installed in the future. For multi-bunch instabilities we used a realistic fill pattern, including hybrid-fill, and tracked multiple bunches where each bunch was treated as soft in distribution.

43 PARTICLE ACCELERATORS↗

Literature Survey on Operational Voltage Control and Reactive Power Management on Transmission and Sub-Transmission Networks

Voltage and reactive power system control is generally performed following usual patterns of loads, based on off-line studies for daily and seasonal operations. This practice is currently challenged by the inclusion of distributed renewable generation, such as solar. There has been focus on resolving this problem at the distribution level; however, the transmission and sub-transmission levels have received less attention. This paper provides a literature review of proposed methods and solution approaches to coordinate and optimize voltage control and reactive power management, with an emphasis on applications at transmission and sub-transmission level. The conclusion drawn from the survey is that additional research is needed in the areas of optimizing switch shunt actions and coordinating all available resources to deal with uncertain patterns from increasing distributed renewable generation in the operational time frame. These topics are not deeply explored in the literature.

capacitors↗

Comparison of Sequence Component-Based Fault Detection and Relay Coordination Algorithms in Inverter-Based Networks

Protection of inverter-based microgrids using sequence component-based relaying schemes is a promising solution. These methods offer several advantages, including lower computational requirements, compatibility with commercial relay systems, and cost-effectiveness compared to communication-based approaches. This article investigate the performance of various sequence component based schemes with the objective of identifying the algorithms that provide the best fault detection and relay coordination, solely relying on local voltages and current at relay terminals. Positive, negative and zero sequence impedance, admittance and power detection algorithms were tested on modified IEEE 13 bus test network for various shunt faults (LG, LL, LLG, LLL). Hardware-in-the-loop validation was achieved using the Typhoon real-time simulator, interfacing with a SEL 751 relay. This research demonstrates that while several algorithms are capable of detecting faults with sufficient accuracy, only a few are effective in achieving proper coordination. Validation results indicate that the negative sequence power approach provides the best performance in both fault detection and coordination.

Patel, Deepika [ORNL] (ORCID:0000000341099994)↗

Test-to-Failure of Crystalline Silicon Modules: Preprint

Accelerated lifetime testing of five crystalline silicon module designs was carried out according to the Terrestrial Photovoltaic Module Accelerated Test-to-Failure Protocol. This protocol compares the reliability of various module constructions on a quantitative basis. The modules under test are subdivided into three accelerated lifetime testing paths: 85..deg..C/85% relative humidity withsystem bias, thermal cycling between 40..deg..C and 85..deg..C, and a path that alternates between damp heat and thermal cycling. The most severe stressor is damp heat with system bias applied to simulate the voltages that modules experience when connected in an array. Positive 600 V applied to the active layer with respect to the grounded module frame accelerates corrosion of the silver gridfingers and degrades the silicon nitride antireflective coating on the cells. Dark I-V curve fitting indicates increased series resistance and saturation current around the maximum power point; however, an improvement in junction recombination characteristics is obtained. Shunt paths and cell-metallization interface failures are seen developing in the silicon cells as determined byelectroluminescence, thermal imaging, and I-V curves in the case of negative 600 V bias applied to the active layer. Ability to withstand electrolytic corrosion, moisture ingress, and ion drift under system voltage bias are differentiated.

14 SOLAR ENERGY↗

A Novel Technique for Performing PID Susceptibility Screening during the Solar Cell Fabrication Process

Various characterization techniques have historically been developed in order to screen potential induced degradation (PID)-susceptible cells, but those techniques require final solar cells. We present a new characterization technique for screening PID-susceptible cells during the cell fabrication process. Illuminated Lock-In Thermography (ILIT) was used to image PID shunting of the cell without metallization and clearly showed PID-affected areas. PID-susceptible cells can be screened by ILIT, and the sample structure can advantageously be simplified as long as the sample has the silicon nitride antireflection coating and an aluminum back surface field.

14 SOLAR ENERGY↗

Evaluation of the PID-s Susceptibility of Modules Encapsulated in Materials of Varying Resistivity

A common mechanism of potential-induced degradation is by shunting (PID-s) in PV modules, usually associated with the transport of sodium ions (Na+) through the encapsulant and penetrating the front junction of solar cells under voltage stress. Encapsulants with high volume resistivity have been suggested as a potentially cost-effective solution to this degradation mechanism. In this work, we examine three polyolefin elastomer (POE) encapsulants with volume resistivity varying over two orders of magnitude (ranging from 9 x 10^13 to 1 x 10^16 ..omega.. cm) that show equivalent and complete resistance to PID at the damp heat stress test level of 85 degrees C and 85% relative humidity and -1000 V system voltage stress. Performance is compared with a PID-susceptible ethylene vinyl acetate (EVA) encapsulant with resistivity 1 x 10^13 ..omega.. cm. The independence of PID susceptibility with respect to the resistivity of the polyolefin is attributed to the impermeability of POEs to Na + ions. Specific ions (i.e. Na + ), rather than charge-carrying species in general, are responsible for this degradation mechanism.

14 SOLAR ENERGY↗

Understanding and Mitigating the Contamination of Intrinsic poly-Si Gaps in Passivated IBC Solar Cells

We investigate factors that are critical for the performance of interdigitated back contact (IBC) solar cells based on polycrystalline silicon (poly-Si) passivated contacts. During patterning of doped lines using direct plasma deposition through a shadow mask, we show that the intrinsic poly-Si gap becomes contaminated with dopants, leading to shunting. Possible contamination mechanisms during masked deposition and high- temperature annealing are tested. Strategies developed to mitigate the contamination, such as reactive ion etching after deposition and amorphous to poly-Si crystallization in oxygen, will lead to improved IBC fabrication methods.

14 SOLAR ENERGY↗

Reformed Mesoporous Ge for Substrate Reuse in III-V Solar Cells

Mesoporous Ge was generated by bipolar electrochemical etching of (100) Ge. Through high-temperature annealing experiments, we found that the mesoporous Ge microstructure produces pore coalescence deep in the structure rather than at the surface. III-V epitaxy on annealed porous Ge with subsurface coalescence and coral-like structures on the surface produced shunted photovoltaic devices. The roughness of the annealed porous Ge film was reduced by a pre-annealing HBr treatment and a post-annealing ultrasonic DI water dip. A smoother reformed surface was obtained, on which a GaInAs upright device with an efficiency of 5.7% was grown, demonstrating a first step towards technical viability.

14 SOLAR ENERGY↗

Evaluation of Carrier Trapping in SiNx Towards Ion Migration Measurements

Sodium ion migration has been implicated in potential induced degradation of the shunting type. The kinetics of sodium migration in silicon nitride can be investigated using a simple capacitance-voltage characterization technique. However, we show that the charge trapping strongly affects the measurement and must be taken into consideration in the experimental approach. Furthermore, we perform a systematic analysis of charge carrier trapping in silicon nitride, allowing us to correct trapping effects that otherwise prevent sodium signal detection. We extract trapping and detrapping time constants both on the order of several hours. This shows that trapping cannot be ignored as it occurs relatively quickly and is constantly evolving in time. Accurate determination of sodium behavior in dielectric layers will facilitate robust co-optimization of these layers for optical, passivation, and barrier properties.

42 ENGINEERING↗

Conductive Adhesives for Metallization of Interdigitated Back Contact Solar Cells

The metallization and interconnection of Si solar cells to form a module is usually a multi-step process: cells are metallized individually, soldered into strings, and subsequently assembled into a module. Furthermore, the metallization process for individual cells must be compatible with the doped surfaces being contacted, which creates additional challenges when moving from diffused junctions to heterojunctions and/or passivated contact structures. To mitigate these problems and streamline module manufacturing for the case of interdigitated back contact (IBC) cell modules, we developed an approach wherein unmetallized IBC cells are bonded directly to a circuitized backsheet using a conductive adhesive (CA) that only conducts out-of-plane. The metal/CA/silicon stack is bonded by hot-pressing at 100-200 degrees C.For a CA consisting of ethylene vinyl acetate (EVA) filled with Ag-coated spheres or indium powder we find that contact resistivities in the range of 1-10 Wcm 2 are obtained, regardless of which conductive filler and which hot pressing parameters are used. XPS revealed that about 1-2 nm EVA residue bonds to the Si in these samples, suggesting the formation of an insulating barrier that is responsible for the high contact resistance. Using indium powder alone, improved contact resistivities <0.6 Wcm 2 , high shunt resistances, and an implied open-circuit voltage loss below 10 mV were obtained. Furthermore, a cost estimate is presented, indicating that substantial cost savings of up to $10/m 2 , or about $0.05/W DC , are possible through CA-based IBC module manufacturing.

14 SOLAR ENERGY↗

Quantitative Prediction of Perovskite Stability Using Accelerated Testing and Machine Learning

PV technologies based on hybrid perovskites offer the potential for reducing solar cell costs, but they are particularly vulnerable to degradation by environmental factors such as moisture, oxygen, and illumination. Commercialization will require not only stable materials and device architectures but also accelerated testing protocols and models that can predict degradation from the accelerated testing data. Here, we report results from in situ photoluminescence (PL) and photoconductivity (PC) measurements during perovskite degradation with simultaneous optical transmittance (Tr) measurements or reflected dark field (DF) imaging. From PL, PC, Tr, and DF, we determine (respectively) the steady-state quasi-Fermi level splitting, the mean effective carrier diffusion length, the extent of conversion of perovskite to higher bandgap degradation products, and the extent of scattering from domains with different orientation or composition, all as a function of time during degradation. Simultaneous measurement of PL-PC-Tr or PL-PC-DF on perovskite absorbers in an environmental chamber over a wide range of humidity, oxygen, temperature, and illumination levels yields a rich data set. We use machine learning to develop a model that accurately predicts (within 10%) the time for the diffusion length to decrease to 85% of its initial value. The model takes the environmental conditions and the first few measurements from the PL-PC-Tr or PL-PC-DF experiment as input. Thus, the model provides a framework to interpret the results of accelerated testing of absorber materials. One of the dominant features in the model of degradation for CH 3 NH 3 PbI 3 is the initial rate at which transmittance increase. For devices with opaque contacts, the pixel-averaged rate of change of the intensity in dark-field images can be used in place of transmittance. Results are also presented on full PV devices with in-situ current-voltage (JV) measurements. Here, the data from simultaneous PL-DF-JV under environmental stresses reveal intimate connection between degradation and shunts and provide a framework to extend accelerated testing to devices. Further, the presentation reveals underlying universal behavior in degradation pathways over a broad range of environmental stresses and perovskite compositions.

14 SOLAR ENERGY↗

Sudden-Discharge Cycling Characteristics and Millisecond Dynamic Behaviors of a HTS Stainless-Steel Insulated Double-Pancake Coil With Thin Copper Plates

We have tested an intermediate-sized HTS stainless-steel (co-wound) insulated double pancake coil (~132 turns per coil) and discovered dynamic effects during sudden discharge on both millisecond and second scales. For soft break, the power supply is turned off suddenly but the shunt resistor (164 milliohm) is still connected; for hard break, a high voltage contactor is used to suddenly open the circuit so that the leads are completely open. Hard break is dangerous to traditionally insulated LTS magnets, but the SS-insulated HTS DPC retained integrity over ¡80 charge-discharge cycles. Voltage decay curves for soft and hard breaks are studied on short and long timescales. On long timescales, we observe the expected exponential decay and measure the time constant to calculate contact resistance. On short timescales, we observe highly dynamic effects: a hyper-exponential decay suggesting that the inductance or contact resistance is suddenly changing with time, likely an indication of the RL circuit forming. Moreover, peak voltage immediately (ms) after the sudden discharge were collected and compared. It is found that the peak voltage in soft-discharge is proportional to the applied current, while the those in hard-break has a unique pattern and tends to stay flat even though the applied current increases.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Critical Current Distributions of Recent Bi-2212 Round Wires

Bi 2 Sr 2 CaCu 2 O 8+x (Bi-2212) is the only high-field, high-temperature superconductor (HTS) capable of reaching a critical current density J c (16 T, 4.2 K) of 6500 A·mm –2 in the highly desirable round wire (RW) form. However, state-of-the-art Bi-2212 conductors still have a critical current density (J c ) to depairing current density (J d ) ratio around 20 to 30 times lower than that of state-of-the-art Nb–Ti or REBCO. Previously, we have shown that recent improvements in Bi-2212 RW J c are due to improved connectivity associated with optimization of the heat treatment process, and most recently due to a transition to a finer and more uniform powder manufactured by Engi-Mat. One quantitative measure of connectivity may be the critical current (I c ) distribution, since the local I c in a wire can vary along the length due to variable vortex-microstructure interactions and to factors such as filament shape variations, grain-to-grain connectivity variations and blocking secondary phase distributions. Modeling the experimental V-I transition measured on a low resistance shunt as a complex sum of voltage contributions of individual filament and wire sub-sections allows a numerical extraction of the I c distribution from the d 2 V/dI 2 treatment of the V-I curves. Here we compare ~0.1 m length I c distributions of Bi-2212 RWs with recent state-of-the-art very high-J c Engi-Mat powder and lower J c and older Nexans granulate powder. We do find that the I c spread for Bi-2212 wires is about twice the relative standard of high-J c Nb–Ti well below H irr . We do not yet see any obvious contribution of the Bi-2212 anisotropy to the I c distribution and are rather encouraged that these Bi-2212 round wires show relative I c distributions not too far from high-J c Nb–Ti wires.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Newton-Raphson AC Power Flow Convergence Based on Deep Learning Initialization and Homotopy Continuation

Power flow forms the basis of many power system studies. With the increased penetration of renewable energy, grid planners tend to perform multiple power flow simulations under various operating conditions and not just selected snapshots at peak or light load conditions. Getting a converged AC power flow (ACPF) case remains a significant challenge for grid planners especially in large power grid networks. This paper proposes a two-stage approach to improve Newton-Raphson ACPF convergence and was applied to a 6102 bus Electric Reliability Council of Texas (ERCOT) system. The first stage utilizes a deep learning-based initializer with data re-training. Here a deep neural network (DNN) initializer is developed to provide better initial voltage magnitude and angle guesses to aid in power flow convergence. This is because Newton-Raphson ACPF is quite sensitive to the initial conditions and bad initialization could lead to divergence. The DNN initializer includes a data re-training framework that improves the initializer's performance when faced with limited training data. The DNN initializer successfully solved 3,285 cases out of 3,899 non-converging dispatch and performed better than random forest and DC power flow initialization methods. ACPF cases not solved in this first stage are then passed through a hot-starting algorithm based on homotopy continuation with switched shunt control. The hot-starting algorithm successfully converged 416 cases out of the remaining 614 non-converging ACPF dispatch. In conclusion, the combined two-stage approach achieved a 94.9% success rate, by converging a total of 3,701 cases out of the initial 3,899 unsolved cases.

Deep learning↗

Inversion Reduction Method for Real and Complex Distribution Feeder Models

We report the proliferation of distributed generation on distribution feeders triggers a large number of integration and planning studies. Further, the complexity of distribution feeder models, short simulation time steps, and long simulation horizons rapidly render studies computational burdensome. To mend this issue, we propose a methodology for reducing the number of nodes, loads, generators, line, and transformers of p-phase distribution feeders with unbalanced loads and generation, non-symmetric wire impedance, mutual coupling, shunt capacitance, and changes in voltage and phase. The methodology is derived on a constant power load assumption and employs a Gaussian elimination inversion technique to design the reduced feeder. Compared to previous work by the authors, the inversion reduction takes half the time and voltage errors after reduction are reduced by an order of magnitude. Using a snapshot simulation the reduction is tested on six additional publicly available feeders with a maximum voltage error 0.0075 p.u. regardless of feeder size or complexity, and typical errors on the order of 1 × 10 -4 p.u. Lastly, for a day long quasi-static time series simulation on the UCSD A feeder, errors are shown to increase with changes in loading when a large number of buses removed, but shows less variation for less than 85% of buses removed.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Loss Minimization With Optimal Power Dispatch in Multi-Frequency HVac Power Systems

Low-frequency high-voltage ac transmission scheme has recently been proposed as an alternative approach for bulk power transmission. This paper proposes a multi-period optimal power flow (OPF) for a multi-frequency HVac transmission system that interconnects both conventional 50/60-Hz and low-frequency grids using back-to-back converters with a centralized control scheme. The OPF objective is to minimize system losses by determining the optimal dispatch for generators, shunt capacitors, and converters. The OPF constraints include the operational constraints of all HVac grid and converter stations. The resulting mixed-integer nonlinear programing problem is solved using a proposed framework based on the predictor-corrector primal-dual interior-point method. The proposed OPF formulation and solution approach are verified using a multi-frequency HVac transmission system that is modified from the IEEE 57-bus system. Here, the results with the optimal dispatch from the proposed method during a simulated day show a significant loss reduction and an improved voltage regulation compared to those when an arbitrary dispatch is chosen.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Optimal Planning and Operation of Multi-Frequency HVac Transmission Systems

Low-frequency high-voltage alternating-current (LF-HVac) transmission scheme has been recently proposed as an alternative solution to conventional 50/60-Hz HVac and high-voltage direct-current (HVdc) schemes for bulk power transfer. This paper proposes an optimal planning and operation for loss minimization in a multi-frequency HVac transmission system. In such a system, conventional HVac and LF-HVac grids are interconnected using back-to-back (BTB) converters. The dependence of system MW losses on converter dispatch as well as the operating voltage and frequency in the LF-HVac is discussed and compared with that of HVdc transmission. Based on the results of the loss analysis, multi-objective optimization formulations for both planning and operation stages are proposed. The planning phase decides a suitable voltage level for the LF-HVac grid, while the operation phase determines the optimal operating frequency and power dispatch of BTB converters, generators, and shunt capacitors. A solution approach that effectively handles the variations of transmission line parameters with the rated voltage and operating frequency in the LF-HVac grid is proposed. The proposed solutions of the planning and operation stages are evaluated using a multi-frequency HVac system. The results show a significant loss reduction and improved voltage regulation during a 24-hour simulation.

Nguyen, Quan H.↗

A New Design Approach to Mitigating the Effect of Parasitics in Capacitive Wireless Power Transfer Systems for Electric Vehicle Charging

This paper introduces a new design approach to mitigate the effect of parasitic capacitances and achieve high performance in large air-gap capacitive wireless power transfer (WPT) systems for electric vehicle (EV) charging. In a capacitive WPT system for EVs, the vehicle chassis and roadway introduce multiple parasitic capacitances that can overwhelm the coupling capacitance and severely degrade power transfer and efficiency. The proposed approach addresses this challenge by employing split-inductor matching networks, which allow the complex network of parasitic capacitances to be simplified into an equivalent four-capacitance model. The shunt capacitances of this model are directly utilized as the matching network capacitors, hence, absorbing the parasitic capacitances and eliminating the need for discrete high-voltage capacitors. A systematic procedure is developed to accurately measure the equivalent capacitances of the model, enabling the system's performance to be reliably predicted. The proposed approach is used to design two 6.78-MHz 12-cm air-gap prototype capacitive WPT systems with capacitor-free matching networks. The first system transfers up to 590 W using 150-cm 2 square coupling plates and achieves an efficiency of 88.4%. The second prototype system transfers up to 1217 W using 118-cm 2 circular coupling plates, achieving a power transfer density of 51.6 kW/m 2 . The measured output power profiles of the two systems match well with their predicted counterparts, validating the proposed design approach.

33 ADVANCED PROPULSION SYSTEMS↗