Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SENSOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

IRIS: High-fidelity Perception Sensor Modeling for Closed-Loop Planetary Simulations

Perception plays a key role in autonomous and semi-autonomous planetary exploration vehicles. For instance, landers can use computer vision techniques for identifying safe landing locations, aerial vehicles use cameras as navigation sensors, and planetary rovers use them for localization and hazard detection. Engineering simulations of such systems requires the accurate modeling of perception and vision sensors for simulating autonomy scenarios. In addition, the modeling of sensors for landers, aerial and ground vehicles requires the ability to handle large and high-resolution terrains, the accurate modeling of illumination, hi-fidelity rendering via ray/path tracing and the inclusion of sensor characteristics. Vision sensor models strive to simulate sensor reality by using physics principles to model the interaction of light and objects. Furthermore, high frame rate performance is highly desirable for in-the-loop simulations involving vehicle dynamics and control software. In this paper we describe a new sensor modeling capability called Inter-planetary Rendering for Imaging and Sensors (IRIS) that meets these requirements for the real-time and high-fidelity simulation of vision sensors for planetary aerospace and robotics applications.

Elmquist, Asher↗

Extending Sensor Calibration Intervals in Nuclear Power Plants

Currently in the USA, sensor recalibration is required at every refueling outage, and it has emerged as a critical path item for shortening outage duration. International application of calibration monitoring, such as at the Sizewell B plant in UK, has shown that sensors may operate for eight years, or longer, within calibration tolerances. Online monitoring can be employed to identify those sensors which require calibration, allowing for calibration of only those sensors which need it. The US NRC accepted the general concept of online monitoring for sensor calibration monitoring in 2000, but no plants have been granted the necessary license amendment to apply it. This project addresses key issues in advanced recalibration methodologies and provides the science base to enable adoption of best practices for applying online monitoring, resulting in a public domain standardized methodology for sensor calibration interval extension. Research to develop this methodology will focus on three key areas: (1) quantification of uncertainty in modeling techniques used for calibration monitoring, with a particular focus on non-redundant sensor models; (2) accurate determination of acceptance criteria and quantification of the effect of acceptance criteria variability on system performance; and (3) the use of virtual sensor estimates to replace identified faulty sensors to extend operation to the next convenient maintenance opportunity.

Calibration Extension↗

Electron beam diagnostic system using computed tomography and an annular sensor

A system for analyzing an electron beam including a circular electron beam diagnostic sensor adapted to receive the electron beam, the circular electron beam diagnostic sensor having a central axis; an annular sensor structure operatively connected to the circular electron beam diagnostic sensor, wherein the sensor structure receives the electron beam; a system for sweeping the electron beam radially outward from the central axis of the circular electron beam diagnostic sensor to the annular sensor structure wherein the electron beam is intercepted by the annular sensor structure; and a device for measuring the electron beam that is intercepted by the annular sensor structure.

47 OTHER INSTRUMENTATION↗

Electron beam diagnostic system using computed tomography and an annular sensor

A system for analyzing an electron beam including a circular electron beam diagnostic sensor adapted to receive the electron beam, the circular electron beam diagnostic sensor having a central axis; an annular sensor structure operatively connected to the circular electron beam diagnostic sensor, wherein the sensor structure receives the electron beam; a system for sweeping the electron beam radially outward from the central axis of the circular electron beam diagnostic sensor to the annular sensor structure wherein the electron beam is intercepted by the annular sensor structure; and a device for measuring the electron beam that is intercepted by the annular sensor structure.

42 ENGINEERING↗

EDGE COMPUTING AND CONTEXTUAL INFORMATION FOR THE INTERNET OF THINGS SENSORS

Interpreting sensor data require knowledge about sensor placement and the surrounding environment. For a single sensor measurement, it is easy to document the context by visual observation, however for millions of sensors reporting data back to a server, the contextual information needs to be automatically extracted from either data analysis or leveraging complimentary data sources. Data layers that overlap spatially or temporally with sensor locations, can be used to extract the context and to validate the measurement. To minimize the amount of data transmitted through the internet, while preserving signal information content, two methods are explored; computation at the edge and compressed sensing. We validate the above methods on wind and chemical sensor data (1) eliminate redundant measurement from wind sensors and (2) extract peak value of a chemical sensor measuring a methane plume. We present a general cloud based framework to validate sensor data based on statistical and physical modeling and contextual data extracted from geospatial data.

Klein, Levente↗

Apparatus, system, and method for sensor authentication

A method includes receiving an output signal from a sensor, recovering a noise signal from the output signal, comparing the noise signal with a stored baseline noise signature, and reporting authentication of the sensor if the comparison is within a pre-determined error limit. A sensor authentication apparatus, comprises a processor and a memory operably coupled with the processor. Instructions, when executed, cause the processor to separate a noise signal from a measured signal, and detect a noise signature match by comparing the noise signal with at least one stored baseline noise signature associated with the sensor. A sensor authentication system comprises a sensor authentication unit and a data acquisition unit. At least one of the sensor authentication unit and the data acquisition unit is configured to compare a noise signal with a baseline noise signature to authenticate the at least one sensor from among a plurality of sensors.

Svoboda, John M.↗

Ultrasonic through-wall sensors

Aspects of ultrasonic through-wall data communication are described. In some aspects, a sensor device is located in an isolated environment behind a wall. A modulator generates a modulated sensor signal based on the binary sensor signal and a carrier signal. A coaxially aligned pair of electroacoustic transducers that transmits the modulated sensor signal through the wall of the isolated environment. A demodulator demodulates the modulated sensor signal to generate a demodulated binary sensor signal. A sensor data recovery component converts the demodulated binary sensor signal into an image or another sensor parameter.

Zhang, Haifeng↗

Performance Before and After Irradiation of Pixelated 3D Silicon Sensors for the HL-LHC CMS Tracker

The Large Hadron Collider (LHC) particle accelerator at European Center for Nuclear Research (CERN) will be shut down starting in 2026 to achieve the High Luminosity Large Hadron Collider (HL-LHC) upgrade. The upgrade will allow for higher fluences, in order to increase the probability of detecting increasingly rare particles, and to obtain higher precision measurements of known particles. To accommodate the new accelerator conditions, many aspects of the Compact Muon Solenoid (CMS) detector will be upgraded; of particular interest for this thesis are the silicon pixel detectors located in the inner tracker. These will be replaced and upgraded to accommodate the higher fluences of the HL-LHC upgrade, as well as to replace existing sensors which have sustained radiation damage. In order for the new sensors to operate under high luminosity conditions, they must be increasingly radiation hard, and in order to detect rare particles, they must be increasingly more precise. The performance of one Centro Nacional de Microelectronica (CNM) 3D silicon sensor before and after undergoing irradiation at fluences similar to those which will be observed at the HL-LHC was investigated to determine radiation hardness and precision. Data was collected at Fermi National Laboratory (Fermilab), in the Fermi National Laboratory Test Beam Facility (FTBF) silicon tracker telescope, which can be used to determine the number of particles, and tracks made by high energy protons passing through. The sensor was also irradiated at Fermilab in the Irradiation Test Area (ITA). Prior to data collection a tuning procedure is carried out to determine ideal bias voltage operating conditions, mask noisy and dead pixels, adjust to the ideal threshold, and map sensor gain. Data is then collected at the FTBF, where the sensor is installed in the center of the FTBF silicon telescope. Variables, including angle and bias voltage, are varied throughout data collection. Data is then processed using an alignment software to determine the exact telescope geometry, along with the tracks which were observed passing through the sensor and telescope. Sensor performance was found to be comparable before and after irradiation, with irradiated results showing slightly lower efficiencies and cluster sizes. Position resolution is comparable both before and after irradiation, and similar distributions of cluster shape are observed. After irradiation, the sensor shows increasing collected charge with bias, an indication of increased width of the depletion region. Peak charge pre-irradiation is higher than post-irradiation peak charge, indicating the irradiated results are not taken under fully-depleted conditions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Individually identifiable surface acoustic wave sensors, tags and systems

A surface-launched acoustic wave sensor tag system for remotely sensing and/or providing identification information using sets of surface acoustic wave (SAW) sensor tag devices is characterized by acoustic wave device embodiments that include coding and other diversity techniques to produce groups of sensors that interact minimally, reducing or alleviating code collision problems typical of prior art coded SAW sensors and tags, and specific device embodiments of said coded SAW sensor tags and systems. These sensor/tag devices operate in a system which consists of one or more uniquely identifiable sensor/tag devices and a wireless interrogator. The sensor device incorporates an antenna for receiving incident RF energy and re-radiating the tag identification information and the sensor measured parameter(s). Since there is no power source in or connected to the sensor, it is a passive sensor. The device is wirelessly interrogated by the interrogator.

Hines, Jacqueline H.↗

Particulate matter sensor

Microfabricated PM sensors measure concentrations of particulate matter (PM) in air. Some sensors improve the accuracy of measurements by accounting for the effect of ambient conditions (e.g., temperature or humidity) on mass-sensitive elements employed to determine a mass of the PM in a stream of air. Some sensors improve the accuracy of measurements by controlling humidity in the stream of air measured by mass-sensitive elements. Some sensors employ a plurality of mass-sensitive elements to extend the useful life of the PM sensor. Some sensors employ one or more mass-sensitive elements and heating elements to cause deposition and allow measurement of different sizes of PM. Some sensors can measure mass concentration of coarse PM in addition to fine PM in a stream of air. Some sensors control the flow rate of a stream of air measured by mass-sensitive elements. Some sensors include features to mitigate electromagnetic interference or electromagnetic signal loss.

Paprotny, Igor↗

The Sensor Dilemma in Intelligent Transportation Systems: Evaluating Radar, Lidar and Camera: Preprint

Intelligent transportation systems (ITS) are at the forefront in advancing the way we interact with and perceive the transportation network. This revolution is fueled by the significant advancement in sensor perception technologies such as radar, lidar, and video imaging, which are the most popular modalities for ITS. Real-time perception data from these sensors allow intelligent infrastructure-side decision-making to improve the energy, efficiency, and safety at traffic intersections. As traffic departments across the United States transition from traditional loop detectors and emulators and embrace newer technologies, they are often left with a dilemma in choosing a sensor technology for infrastructure-based perception that is reliable, inexpensive, and easy to set up and that has robust performance in varying weather conditions. However, choosing a sensor that checks all these boxes is not straightforward, as every sensor type has unique benefits and drawbacks. Radar is excellent at detecting long-range vehicles and weather resistance but lacks high resolution. Lidar is expensive and weather-sensitive, while cameras provide rich visual data at a low cost but are constrained by lighting and visibility. This study examines radar, lidar, and camera sensor capabilities to ascertain whether any of these qualifies as the "best" sensor for ITS perception. While no single sensor can meet all the demands of ITS, a hybrid approach combining multiple sensor modalities like radar, lidar, and cameras offers the most robust solution for enhancing the safety and efficiency of ITS. Through this evaluation, we hope to draw attention to the necessity of the National Renewable Energy Laboratory's infrastructure perception and control framework, which presents a multisensor track data fusion engine to assimilate multiple data streams in order to provide robust and reliable perception.

33 ADVANCED PROPULSION SYSTEMS↗

Using non-invasive MEMS pressure sensors for measuring building envelope air leakage

Micro-electromechanical systems (MEMS)-based sensors have seen significant improvements in accuracy and cost over the past several years, and due to the need for altitude sensing in unmanned aerial vehicles and wearable technologies, absolute pressure sensors have shown the most dramatic improvements. This paper investigates applications of MEMS sensors in commercial buildings, including pairing two absolute pressure sensors to determine differential pressures between different locations in and around buildings. Differential pressure measurements are commonly made in commercial buildings for a number of applications, including static pressure measurements for variable-speed supply fan control, air balancing in hospitals, and for envelope and duct air leakage testing. This paper focuses specifically on envelope air-leakage testing applications of these sensors. The use of continuous pressure measurements in addition to one-time non-intrusive outdoor airflow measurements of rooftop packaged units is investigated. A comparison with standardized leakage testing indicated that continuous measurements with MEMS pressure-sensors were able to estimate envelope leakage to within 3–16% of the standardized test result. In addition, the magnitude and stability of differential pressure differences that can be resolved with absolute pressure sensors are also investigated in the laboratory and the field. Results show that the sensors can be effectively used for pressures seen in low rise buildings with rooftop units.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Long-Term field testing of the accuracy and HVAC energy savings potential of occupancy presence sensors in A Single-Family home

The energy-saving potential of occupancy-centric smart thermostats has been extensively explored in simulations but lacked field testing for energy savings quantification and sensor performance assessment in real buildings. This paper presents a long-term field study conducted in a single-family home in Texas, U.S. to evaluate the performance of occupancy-centric controls (OCC) of HVAC (heating, ventilation, and air-conditioning) system in terms of energy savings, sensor accuracy, and impact on electric peak demand. The test site was equipped with a commercial off-the-shelf (COTS) smart thermostat and multiple occupancy presence sensors for OCC implementation. Additionally, a sub-metering system was installed to monitor electricity consumption of various end-use equipment, including the HVAC system. A supplementary device was installed to track the ground-truth occupancy for the accuracy evaluation of the occupancy presence sensor. Scenarios of baseline and OCC controls were alternated weekly over the 20-month testing period. The results indicated an effective OCC execution, as evidenced by indoor temperature profiles. During the 2023 cooling season, OCC achieved total energy savings of 1,958 kWh, corresponding to a 17.6% energy savings ratio. Under certain conditions, daily HVAC energy savings reached as high as 17 kWh, with a savings ratio of 35%. Sensor performance showed an overall accuracy of 83.8%, a False Positive Rate (FPR) of 12.8%, and a False Negative Rate (FNR) of 47.4%. A key limitation was the sensor’s inability to detect stationary occupants during sleep, leading to a midnight FNR of nearly 100% and significantly compromising thermal comfort. Additionally, the implementation of OCC resulted in extended periods of high electricity demand on summer afternoons, affecting occupant’s thermal comfort and posing potential challenges to community-level grid operations if OCC were widely adopted. Furthermore, this study addresses a critical research gap by empirically investigating energy-saving potential and occupancy sensor performance in residential buildings. Through a comprehensive field-testing study, the research examines the interrelationship between sensor accuracy, energy savings, and thermal comfort, an area that has received limited attention in the current literature.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Mitigating humidity interference in chemiresistive hydrogen sensors through hydrophobic surface functionalization

Chemiresistive gas sensors based on semiconductor metal oxides, such as tin dioxide (SnO₂), are indispensable for detecting and monitoring toxic gases and pollutants, making them critical components in industrial and environmental applications. To enhance their performance, the metal oxides are loaded with noble metals such as palladium (Pd). However, ambient humidity poses a significant challenge to their performance. The presence of adsorbed water molecules on the oxide surface can considerably impair sensor sensitivity and overall performance. To address this issue, in this paper, we report on the application of an ultrathin, hydrophobic layer of hexamethyldisilazane to the surface of a Pd/SnO 2 sensor. This study investigates the influence of hydrophobic surface modifications on the metal oxide interface, focusing on their impact on sensor sensitivity and selectivity. The resulting sensor exhibits superior hydrogen sensing capabilities, operating effectively at low temperatures even in high humidity environments. Furthermore, the hydrophobic modification reduces the sensor’s susceptibility to interfering gases, thus enhancing its selectivity. The combined enhancements in moisture resistance and selectivity achieved through HMDS surface modification, along with the superior sensitivity of Pd/SnO₂ sensors, facilitate the development of gas sensors with enhanced humidity tolerance and broader applications.

Chemiresistive gas sensors↗

Several Small or Single Large? Quantifying the Catchment-Wide Performance of On-Site Wastewater Treatment Plants with Inaccurate Sensors

On-site wastewater treatment plants (OSTs) often lack monitoring, resulting in unreliable treatment performance. They thus appear to be a stopgap solution despite their potential contribution to circular water management. Low-maintenance but inaccurate soft sensors are emerging that address this concern. However, how their inaccuracy impacts the catchment-wide treatment performance of a system of many OSTs has not been quantified. Here, we develop a stochastic model to estimate catchment-wide OST performances with a Monte Carlo simulation. In our study, soft sensors with a 70% accuracy improved the treatment performance from 66% of the time functional to 98%. Soft sensors optimized for specificity, indicating the true negative rate, improve the system performance, while sensors optimized for sensitivity, indicating the true positive rate, quantify the treatment performance more accurately. This new insight leads us to suggest programming two soft sensors in practical settings with the same hardware sensor data as input: one soft sensor geared to high specificity for maintenance scheduling and one geared to high sensitivity for performance quantification. Our findings suggest that a maintenance strategy combining inaccurate sensors with appropriate alarm management can vastly improve the mean catchment-wide treatment performance of a system of OSTs.

54 ENVIRONMENTAL SCIENCES↗

Sensor Configuration Selection for Discrete-Event Systems under Unreliable Observations

Algorithms for counting the occurrences of special events in the framework of partially-observed discrete event dynamical systems (DEDS) were developed in previous work. Their performances typically become better as the sensors providing the observations become more costly or increase in number. This paper addresses the problem of finding a sensor configuration that achieves an optimal balance between cost and the performance of the special event counting algorithm, while satisfying given observability requirements and constraints. Since this problem is generally computational hard in the framework considered, a sensor optimization algorithm is developed using two greedy heuristics, one myopic and the other based on projected performances of candidate sensors. The two heuristics are sequentially executed in order to find best sensor configurations. The developed algorithm is then applied to a sensor optimization problem for a multiunit- operation system. Results show that improved sensor configurations can be found that may significantly reduce the sensor configuration cost but still yield acceptable performance for counting the occurrences of special events.

97 MATHEMATICS AND COMPUTING↗

Staggered scheduling of sensor estimation and fusion for tracking over long-haul links

Networked sensing can be found in a multitude of real-world applications. Here, we focus on the communication-and computation-constrained long-haul sensor networks, where sensors are remotely deployed over a vast geographical area to perform certain tasks. Of special interest is a class of such networks where sensors take measurements of one or more dynamic targets and send their state estimates to a remote fusion center via long-haul satellite links. The severe loss and delay over such links can easily reduce the amount of sensor data received by the fusion center, thereby limiting the potential information fusion gain and resulting in suboptimal tracking performance. In this paper, starting with the temporal-domain staggered estimation for an individual sensor, we explore the impact of the so-called intra-state prediction and retrodiction on estimation errors. We then investigate the effect of such estimation scheduling across different sensors on the spatial-domain fusion performance, where the sensing time epochs across sensors are scheduled in an asynchronous and staggered manner. In particular, the impact of communication delay and loss as well as sensor bias on such scheduling is explored by means of numerical and simulation studies that demonstrate the validity of our analysis.

47 OTHER INSTRUMENTATION↗

Countering sensor drift in x-ray micrscopy with fast and robust optimal control

In X-ray microscopy it is imperative that the relative position between the optics stage, that carries the X-ray focusing optics, and the sample stage follow a certain trajectory while either the optics or sample stage is being scanned. Main challenges in achieving this requirement include - open loop drift, environmental disturbance, measurement noise, sensor drift, and control hardware limit. The state-of-the-art in X-ray microscopy at Advanced Photon Source (APS) at Argonne National Laboratory (ANL) features an H ∞ control architecture applied to only the optics stage or both the optics and sample stage, achieving the objectives of large tracking bandwidth over 200 Hz, good positioning resolution on the order of nanometers, rejection of environmental disturbance, attenuation of measurement noise, good Xray diffraction image resolution and increased imaging bandwidth. However, an unaddressed issue in our existing robust control design is that the sensors and the fixtures that hold the sensors drift with time due to changing air temperature in the APS beamline. Since the drift of sensor itself is not measured, it affects the relative position between the focusing optics and sample resulting into imaging artifacts and reduced image resolution. In this article, we demonstrate the rejection of the sensor drift by directly measuring the displacement of the sensor with respect to the global reference frame. Both the measured sensor displacement (i.e. sensor drift) and optics stage displacement are incorporated in the H ∞ control architecture to achieve the above mentioned objectives in addition to minimal relative displacement between the optics stage and the sample stage. This will improve the Xray image resolution and reduce image artifacts.

Robust Control↗