Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SCAN”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Tuning and scanning control system for high resolution alexandrite lasers

An alexandrite laser is spectrally narrowed and tuned by the use of three optical elements. Each element provides a successively higher degree of spectral resolution. The digitally controlled tuning and scanning control servo system simultaneously positions all three optical elements to provide continuous high resolution laser spectral tuning. The user may select manual, single, or continuous modes of automated scanning of ranges up to 3.00/cm and at scan rates up to 3.85/cm/min. Scanning over an extended range of up to 9.999/cm may be achieved if the highest resolution optic is removed from the system. The control system is also capable of being remotely operated by another computer or controller via standard RS-232 serial data link.

Smith, James C.↗

Unbalanced Rotating Masses For Scanning

Unbalanced rotating masses low-cost, low-power, lightweight means of generating scanning torques for scientific instruments. Imparts variety of scanning patterns; continuous circular, back-and-forth linear, and, with aid of indexing mechanism, raster. Scanning rate determined by sizes of moment arms and rotational velocities. System of unbalanced rotating masses proposed for scanning gimbaled sensors that observe Sun from balloon-borne gondola. Two unbalanced masses move sensor aim in circular pattern around center of the Sun.

Polites, Michael E.↗

Reconfiguring the RUM experiment to test circular scanning with rotating unbalanced-mass devices on gimbaled payloads

This paper describes a ground-based experiment designed to prove the concept of circular scanning a gimbaled payload with rotating unbalanced-mass (RUM) devices. The experiment is a modified version of a similar experiment which demonstrates line and raster scanning with RUM's. In this paper, a description of the experiment hardware is presented and a detailed design of the servos used in scanning is given. A computer simulation model of the entire system is discussed and simulation results are included. These verify the servo designs and show the RUM's to be an extremely power efficient method for circular scanning.

Polites, M. E.↗

Scanning Tunneling Microscope For Use In Vacuum

Scanning tunneling microscope with subangstrom resolution developed to study surface structures. Although instrument used in air, designed especially for use in vacuum. Scanning head is assembly of small, mostly rigid components made of low-outgassing materials. Includes coarse-positioning mechanical-translation stage, on which specimen mounted by use of standard mounting stub. Tunneling tip mounted on piezoelectric fine-positioning tube. Application of suitable voltages to electrodes on piezoelectric tube controls scan of tunneling tip across surface of specimen. Electronic subsystem generates scanning voltages and collects data.

Abel, Phillip B.↗

Radar sensitivity and antenna scan pattern study for a satellite-based Radar Wind Sounder (RAWS)

Modeling global atmospheric circulations and forecasting the weather would improve greatly if worldwide information on winds aloft were available. Recognition of this led to the inclusion of the LAser Wind Sounder (LAWS) system to measure Doppler shifts from aerosols in the planned for Earth Observation System (EOS). However, gaps will exist in LAWS coverage where heavy clouds are present. The RAdar Wind Sensor (RAWS) is an instrument that could fill these gaps by measuring Doppler shifts from clouds and rain. Previous studies conducted at the University of Kansas show RAWS as a feasible instrument. This thesis pertains to the signal-to-noise ratio (SNR) sensitivity, transmit waveform, and limitations to the antenna scan pattern of the RAWS system. A dop-size distribution model is selected and applied to the radar range equation for the sensitivity analysis. Six frequencies are used in computing the SNR for several cloud types to determine the optimal transmit frequency. the results show the use of two frequencies, one higher (94 GHz) to obtain sensitivity for thinner cloud, and a lower frequency (24 GHz) to obtain sensitivity for thinner cloud, and a lower frequency (24 GHz) for better penetration in rain, provide ample SNR. The waveform design supports covariance estimation processing. This estimator eliminates the Doppler ambiguities compounded by the selection of such high transmit frequencies, while providing an estimate of the mean frequency. the unambiguous range and velocity computation shows them to be within acceptable limits. The design goal for the RAWS system is to limit the wind-speed error to less than 1 ms(exp -1). Due to linear dependence between vectors for a three-vector scan pattern, a reasonable wind-speed error is unattainable. Only the two-vector scan pattern falls within the wind-error limits for azimuth angles between 16 deg to 70 deg. However, this scan only allows two components of the wind to be determined. As a result, a technique is then shown, based on the Z-R-V relationships, that permit the vertical component (i.e., rain) to be computed. Thus the horizontal wind components may be obtained form the covariance estimator and the vertical component from the reflectivity factor. Finally, a new candidate system is introduced which summarizes the parameters taken from previous RAWS studies, or those modified in this thesis.

Stuart, Michael A.↗

Directivity versus element spacing for a scanning array

The results of the present examination of the relationship of directivity with element spacings of linear, rectangular, and hexagonal arrays indicate that element spacings for optimal directivity vary with scan angles; this is especially true in the case of changes in aperture sizes and the appearance of grating lobes in the visible space. Grating lobe effects are more pronounced for isotropic than for directive element arrays. Directivity decreases as the beam scans off from boresight, and rapidly diminishes for scans over 30 deg. The hexagonal array has higher directivity for scans of less than 20 deg, and the linear array for those over 30 deg.

Zimmerman, M.↗

Scanning tunneling microscopy studies of diamond films and optoelectronic materials

In this report, we report on progress achieved from 12/1/92 to 10/1/93 under the grant entitled 'Scanning Tunneling Microscopy Studies of Diamond Films and Optoelectronic Materials'. We have set-up a chemical vapor deposition (CVD) diamond film growth system and a Raman spectroscopy system to study the nucleation and growth of diamond films with atomic resolution using scanning tunneling microscopy (STM). A unique feature of the diamond film growth system is that diamond films can be transferred directly to the ultrahigh vacuum (UHV) chamber of a scanning tunneling microscope without contaminating the films by exposure to air. The University of North Texas (UNT) provided $20,000 this year as matching funds for the NASA grant to purchase the diamond growth system. In addition, UNT provided a Coherent Innova 90S Argon ion laser, a Spex 1404 double spectrometer, and a Newport optical table costing $90,000 to set-up the Raman spectroscopy system. The CVD diamond growth system and Raman spectroscopy system will be used to grow and characterize diamond films with atomic resolution using STM as described in our proposal. One full-time graduate student and one full-time undergraduate student are supported under this grant. In addition, several graduate and undergraduate students were supported during the summer to assist in setting-up the diamond growth and Raman spectroscopy systems. We have obtained research results concerning STM of the structural and electronic properties of CVD grown diamond films, and STM and scanning tunneling spectroscopy of carbon nanotubes. In collaboration with the transmission electron microscopy (TEM) group at UNT, we have also obtained results concerning the optoelectronic material siloxene. These results were published in refereed scientific journals, submitted for publication, and presented as invited and contributed talks at scientific conferences.

Perez, Jose M.↗

Non-Scanning Radiometer Results for Earth Radiation Budget Investigations

The Earth Radiation Budget Experiment (ERBE) included non-scanning radiometers (Luther, 1986) flown aboard a dedicated mission of Earth Radiation Budget Satellite, and the NOAA-9 and -10 operational meteorological spacecraft (Barkstrom and Smith, 1986). The radiometers first began providing Earth radiation budget data in November 1984 and have remained operational, providing a record of nearly 8 years of data to date for researchers. Although they do not produce measurements with the resolution given by the scanning radiometers, the results from the non-scanning radiometers are extremely useful for climate research involving long-term radiation data sets. This paper discusses the non-scanning radiometers, their stability, the method of analyzing the data, and brief scientific results from the data.

Smith, G. Louis↗

Z-Scan Measurement of the Nonlinear Absorption of a Thin Gold Film

We have used the z-scan technique at a wavelength (532 nm) near the transmission window of bulk gold to measure the nonlinear absorption coefficient of continuous approximately 50-Angstrom-thick gold films, deposited onto surface-modified quartz substrates. For highly absorbing media such as metals, we demonstrate that determination of either the real or imaginary part of the third-order susceptibility requires a measurement of both nonlinear absorption and nonlinear refraction, i.e. both open- and closed-aperture z-scans must be performed. Closed-aperture z-scans did not yield a sufficient signal for the determination of the nonlinear refraction. However, open-aperture z-scans yielded values ranging from Beta = 1.9 x 10(exp -3) to 5.3 x 10(exp -3) cm/W in good agreement with predictions which ascribe the nonlinear response to a Fermi smearing mechanism. We note that the sign of the nonlinearity is reversed from that of gold nanoparticle composites, in accordance with the predictions of mean field theories.

Smith, David D.↗

Ground Based Operational Testing Of Holographic Scanning Lidars : The HOLO Experiments

Two aerosol backscatter lidar measurement campaigns were conducted using two holographic scanning lidars and one zenith staring lidar for the purposes of reliability testing under field conditions three new lidar systems and to develop new scanning measurement techniques and applications. The first campaign took place near the campus of Utah State University in Logan Utah in March of 1999 and is called HOLO-1. HOLO-2 was conducted in June of 1999 on the campus of Saint Anselm College, near the city of Manchester, New Hampshire. Each campaign covered a period of approximately one week of nearly continuous observation of cloud and aerosol backscatter in the visible and near infrared by lidar, and wide field visible sky images by video camera in the daytime. The scanning capability coupled with a high rep-rate, high average power laser enables both high spatial and high temporal resolution observations that Particularly intriguing is the possibility of deriving atmospheric wind profiles from temporal analysis of aerosol backscatter spatial structure obtained by conical scan without the use of Doppler techniques.

Schwemmer, Geary K.↗

Potential Challenges in Near-Field Scanning Optical Microscopy for Space Applications

Near-field scanning optical microscopy (NSOM) also called scanning near-field optical microscopy (SNOM) is now well accepted as a powerful tool for sub-wavelength (nanoscale in the optical region) spatial resolution microscopy and a large number of related tasks. The importance lies in the fact of strategic advantages of standard microscopy but with significantly enhanced resolution. Since many modern optical diagnostic techniques have found useful applications in space, it is logical to consider the future role of NSOM in such situations. For example, protein crystal growth study under microgravity conditions is a valid candidate. If applied successfully, processes at molecular level can be studied during the growth. NSOM has already been demonstrated to be useful for the study of such crystals here on earth. The basic principle of NSOM can be illustrated. The illumination-collection mode is shown although several other possible approaches exist. In this, the sample is illuminated and the light from the sample is collected through the same tiny aperture opening. A tapered optical fiber is scanned near the sample surface. The tip is coated generally with a metal with a sub-wavelength aperture opening. The tip-sample distance is maintained constant while scanning. Thus, the optical signal available for collection is generally a function of the optical properties of the sample surface. Since the aperture is sub-wavelength in diameter and the tip is held very close (again in the sub-wavelength domain) to the surface, the lateral resolution in the sub-wavelength domain is obtained. Thus, the typical wavelength- order resolution of ordinary microscopy can be significantly enhanced while maintaining the strategic advantages (no need of sample in vacuum chamber, electron beams, etc). Commercial NSOM systems play a key role in the success and widespread acceptance of the tool. These commercial systems work fairly well in laboratory conditions on earth. However, they may not be deployed on a space mission as such with comparable outcome. In this communication we discuss several potential problems and some possible solutions.

Vikram, Chandra S.↗

Carbon Nanotube Tip Probes: Stability and Lateral Resolution in Scanning Probe Microscopy and Application to Surface Science to Semiconductors

In this paper we present results on the stability and lateral resolution capability of carbon nanotube (CNT) scanning probes as applied to atomic force microscopy (AFM). Surface topography images of ultra-thin films (2-5 nm thickness) obtained with AFM are used to illustrate the lateral resolution capability of single-walled carbon nanotube probes. Images of metal films prepared by ion beam sputtering exhibit grain sizes ranging from greater than 10 nm to as small as approximately 2 nm for gold and iridium respectively. In addition, imaging stability and lifetime of multi-walled carbon nanotube scanning probes are studied on a relatively hard surface of silicon nitride (Si3N4). AFM images Of Si3N4 surface collected after more than 15 hrs of continuous scanning show no detectable degradation in lateral resolution. These results indicate the general feasibility of CNT tips and scanning probe microscopy for examining nanometer-scale surface features of deposited metals as well as non-conductive thin films. AFM coupled with CNT tips offers a simple and nondestructive technique for probing a variety of surfaces, and has immense potential as a surface characterization tool in integrated circuit manufacturing.

Nguyen, Cattien V.↗

Slow Scan Telemedicine

Originally developed under contract for NASA by Ball Bros. Research Corporation for acquiring visual information from lunar and planetary spacecraft, system uses standard closed circuit camera connected to a device called a scan converter, which slows the stream of images to match an audio circuit, such as a telephone line. Transmitted to its destination, the image is reconverted by another scan converter and displayed on a monitor. In addition to assist scans, technique allows transmission of x-rays, nuclear scans, ultrasonic imagery, thermograms, electrocardiograms or live views of patient. Also allows conferencing and consultation among medical centers, general practitioners, specialists and disease control centers. Commercialized by Colorado Video, Inc., major employment is in business and industry for teleconferencing, cable TV news, transmission of scientific/engineering data, security, information retrieval, insurance claim adjustment, instructional programs, and remote viewing of advertising layouts, real estate, construction sites or products.

Source record↗

Lidar Data Products and Applications Enabled by Conical Scanning

Several new data products and applications for elastic backscatter lidar are achieved using simple conical scanning. Atmospheric boundary layer spatial and temporal structure is revealed with resolution not possible with static pointing lidars. Cloud fractional coverage as a function of altitude is possible with high temporal resolution. Wind profiles are retrieved from the cloud and aerosol structure motions revealed by scanning. New holographic technology will soon allow quasi-conical scanning and push-broom lidar imaging without mechanical scanning, high resolution, on the order of seconds.

Schwemmer, Geary K.↗

Scanning Mode Shock Position Sensor Invented and Demonstrated

A flow-visualizing system with a scanning optical beam offers greater advantages than the conventional approaches. In addition to a higher signal-to-noise ratio and lower source power, the scanning permits visualization of weak phenomena such as the scattering and diffraction of light on shocks. Scanning beam flow-visualization techniques were evaluated at the NASA Lewis Research Center for shock position sensing. In an effort to eliminate moving parts, a spectral scanning technique was invented and demonstrated.

Adamovsky, Grigory↗

Scan mirror remote temperature sensing system and method

A remote temperature sensing system (10) for a scanning mirror (7). The system (10) includes a sensor which detects heat radiated by the mirror and provides a signal in response thereto. In the illustrative implementation, the system (10) includes a thermistor mounted within a housing. The housing is contoured to maximize the receipt of thermal energy thereby. A mounting assembly maintains the thermistor a predetermined nonzero distance from the scanning mirror (7). The invention includes a shroud (12) mounted on the mirror (7) for shielding the thermistor and a support tube connected to the thermistor housing on a first end and to a base on the second end thereof. The support tube is adapted to remain stationary within the shroud as the scanning mirror and the shroud rotate due to the scanning of the mirror. Wires are connected to the thermistor on a first end thereof and are wrapped around the support tube. The wires include a length of electrically conductive material having a resistivity which has a low sensitivity to temperature variations. The sensor output is processed in a conventional manner to provide an output indicative of the temperature of the mirror.

VanDyk, Steven G.↗

Wide-Angle-Scanning Reflectarray Antennas Actuated by MEMS

An effort to develop large-aperture, wide-angle-scanning reflectarray antennas for microwave radar and communication systems is underway. In an antenna of this type as envisioned, scanning of the radiated or incident microwave beam would be effected through mechanical rotation of the passive (reflective) patch antenna elements, using microelectromechanical systems (MEMS) stepping rotary actuators typified by piezoelectric micromotors. It is anticipated that the cost, mass, and complexity of such an antenna would be less than, and the reliability greater than, those of an electronically scanned phased-array antenna of comparable beam-scanning capability and angular resolution. In the design and operation of a reflectarray, one seeks to position and orient an array of passive patch elements in a geometric pattern such that, through constructive interference of the reflections from them, they collectively act as an efficient single reflector of radio waves within a desired frequency band. Typically, the patches lie in a common plane and radiation is incident upon them from a feed horn.

Fang, Houfei↗

Scanning Miniature Microscopes without Lenses

The figure schematically depicts some alternative designs of proposed compact, lightweight optoelectronic microscopes that would contain no lenses and would generate magnified video images of specimens. Microscopes of this type were described previously in Miniature Microscope Without Lenses (NPO - 20218), NASA Tech Briefs, Vol. 22, No. 8 (August 1998), page 43 and Reflective Variants of Miniature Microscope Without Lenses (NPO 20610), NASA Tech Briefs, Vol. 26, No. 9 (September 1999), page 6a. To recapitulate: In the design and construction of a microscope of this type, the focusing optics of a conventional microscope are replaced by a combination of a microchannel filter and a charge-coupled-device (CCD) image detector. Elimination of focusing optics reduces the size and weight of the instrument and eliminates the need for the time-consuming focusing operation. The microscopes described in the cited prior articles contained two-dimensional CCDs registered with two-dimensional arrays of microchannels and, as such, were designed to produce full two-dimensional images, without need for scanning. The microscopes of the present proposal would contain one-dimensional (line image) CCDs registered with linear arrays of microchannels. In the operation of such a microscope, one would scan a specimen along a line perpendicular to the array axis (in other words, one would scan in pushbroom fashion). One could then synthesize a full two-dimensional image of the specimen from the line-image data acquired at one-pixel increments of position along the scan. In one of the proposed microscopes, a beam of unpolarized light for illuminating the specimen would enter from the side. This light would be reflected down onto the specimen by a nonpolarizing beam splitter attached to the microchannels at their lower ends. A portion of the light incident on the specimen would be reflected upward, through the beam splitter and along the microchannels, to form an image on the CCD. If the nonpolarizing beam splitter were replaced by a polarizing one, then the specimen would be illuminated by s-polarized light. Upon reflection from the specimen, some of the s-polarized light would become p-polarized. Only the p-polarized light would contribute to the image on the CCD; in other words, the image would contain information on the polarization rotating characteristic of the specimen.

Wang, Yu↗