Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SAMPLING DEVICE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

A 3D-Printed, Portable, Optical-Sensing Platform for Smartphones Capable of Detecting the Herbicide 2,4-Dichlorophenoxyacetic Acid

Onsite rapid detection of herbicide and herbicide residuals in environmental and biological specimens is important for agriculture, environment, food safety, and health care. Traditional method for herbicide detection requires expensive laboratory equipment and a long turn-round time. In this work, we developed a single-stripe microliter plate smartphone colorimetric device for rapid and low-cost in-field test. This portable smartphone platform is capable of screening 8 samples in a microplate single-stripe. The device combined the advantages of small size (50×100×160 mm3) and low cost ($10). The platform was calibrated by using two different dye solutions, i.e. methyl blue (MB) and Rhodamine B, for green and red channels. The results showed good correlation with results attained from a traditional laboratory reader. We demonstrated the application of this platform for an herbicide, 2,4-Dichlorophenoxyacetic acid detection in the range of 1 ppb to 80 ppb. Spiked samples of tap water, rat serum, plasma and human serum were tested by our device. Recoveries obtained varied from 95.6% to 105.2% for all spiked samples using the microplate reader and from 93.7% to 106.9% using the smartphone device. This work validated that the smartphone optical sensing platform is comparable to the commercial microplate reader, it is eligible for onsite rapid and low-cost detection of herbicide for environmental evaluation and biological monitoring.

Wang, Yijia↗

Significant Efficiency Enhancements in Non‐Y Series Acceptors by the Addition of Outer Side Chains

Abstract Most current highly efficient organic solar cells utilize small molecules like Y6 and its derivatives as electron acceptors in the photoactive layer. In this work, a small molecule acceptor, SC8‐IT4F, is developed through outer side chain engineering on the terminal thiophene of a conjugated 6,12‐dihydro‐dithienoindeno[2,3‐d:2′,3′‐d′]‐s‐indaceno[1,2‐b:5,6‐b′]dithiophene (IDTT) central core. Compared to the reference molecule C8‐IT4F, which lacks outer side chains, SC8‐IT4F displays notable differences in molecule geometry (as shown by simulations), thermal behavior, single‐crystal packing, and film morphology. Blend films of SC8‐IT4F and the polymer donor PM6 exhibit larger carrier mobilities, longer carrier lifetimes, and reduced recombination compared to C8‐IT4F, resulting in improved device performance. Binary photovoltaic devices based on the PM6:SC8‐IT4F films reveal an optimal efficiency over 15%, which is one of the best values for non‐Y type small molecule acceptors (SMAs). The resultant devices also show better thermal and operational stability than the control PM6:L8‐BO devices. SC8‐IT4F and its blend exhibit a higher relative degree of crystallinity and π coherence length, compared to C8‐IT4F samples, beneficial for charge transport and device performance. The results indicate that outer side chain engineering on existing small electron acceptors can be a promising molecular design strategy for further pursuing high‐performance organic solar cells.

He, Qiao [Department of Chemistry and Centre for P↗

The crystal structure and magnetic properties of Ba{sub 2−x}Sr{sub x}Co{sub 2}Fe{sub 12}O{sub 22}

We have synthesized the Ba{sub 2−x}Sr{sub x}Co{sub 2}Fe{sub 12}O{sub 22} samples (x = 0.1, 0.2, 0.3, 0.4, 0.5) by the solid-state reaction method and investigated their crystalline and magnetic properties by X-ray diffractometer (XRD), Mössbauer spectrometer, vibrating sample magnetometer, and network analyzer. XRD patterns show that all samples are rhombohedral with space group R-3m. The lattice constants a{sub 0} and c{sub 0} decrease with Sr substitution due to smaller ion radius of Sr{sup 2+} (1.27 Å) than that of Ba{sup 2+} (1.43 Å). The Mössbauer spectroscopy measurements show that the relative area ratios of Fe ion were maintained constant regardless of the Sr concentration. However, average magnetic hyperfine field slightly increased with the Sr concentration. This observation agrees with the fact that the saturation magnetization (M{sub s}) linearly increases due to the increasing super-exchange interaction, originated from the difference in the ionic radius between Ba{sup 2+} and Sr{sup 2+}. To investigate its properties at high frequency range, all samples were sintered at 1100 °C, and complex permeability and permittivity were measured by network analyzer between 100 MHz and 4 GHz. For x below 0.3, the initial permeability at 100 MHz increases, at higher values of x, its value decreases. Our study shows that magnetic properties of Sr{sup 2+} substitution for Ba{sup 2+} in Y-type hexaferrite as well as low magnetic loss less than 0.1 in 1 GHz band, indicating the potential application of Ba{sub 2−x}Sr{sub x}Co{sub 2}Fe{sub 12}O{sub 22} samples for RF and antenna devices in ultra high frequency band.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Visualization of Current and Mapping of Elements in Quantum Dot Solar Cells

The delicate influence of properties such as high surface state density and organic-inorganic boundaries on the individual quantum dot electronic structure complicates pursuits toward forming quantitative models of quantum dot thin films ab initio. Our report describes the application of electron beam-induced current (EBIC) microscopy to depleted-heterojunction colloidal quantum dot photovoltaics (DH-CQD PVs), a technique which affords one a map of current production within the active layer of a PV device. The effects of QD sample size polydispersity as well as layer thickness in CQD active layers as they pertain to current production within these PVs are imaged and explained. The results from these experiments compare well with previous estimations, and confirm the ability of EBIC to function as a valuable empirical tool for the design and betterment of DH-CQD PVs. Lastly, extensive and unexpected PbS QD penetration into the mesoporous TiO 2 layer is observed through imaging of device cross sections by energy-dispersive X-ray spectroscopy combined with scanning transmission electron microscopy. Finally, the effects of this finding are discussed and corroborated with the EBIC studies on similar devices.

14 SOLAR ENERGY↗

Portable and Cost-Effective Device for Reliable Detection of Counterfeit and Non-compliant Refrigerants in Diverse Applications

Counterfeit refrigerants pose significant challenges to safety, system reliability, and operational effectiveness due to their harmful contaminants or incompatible chemical compositions. Utilizing these noncompliant products can lead to reduced efficiency, equipment failures, and expensive repairs. Additionally, heightened demand for alternative refrigerants during the industry's transition has created supply gaps, enabling counterfeit products to proliferate. Accurate detection and analysis tools are therefore essential to verify refrigerant authenticity and ensure system integrity in diverse applications. This paper presents the development of a portable device designed for reliable identification and detailed analysis of refrigerant composition. By integrating precision gas sampling, controlled pressure regulation, and automated sensor technology, the device not only detects deviations from standard refrigerant properties but also provides a comprehensive composition breakdown. Pre-calibrated sensors measure the refrigerant gas to identify specific concentrations and contaminants, with an intuitive LED-based indicator system ensuring quick interpretation of results. The user-friendly interface enables operators to select refrigerant types for targeted testing, further enhancing accuracy and usability for field technicians. Comprehensive testing was conducted on mildly flammable A2L refrigerants, showcasing the device’s robustness and adaptability in analyzing composition and detecting discrepancies. The device demonstrated consistent accuracy across a range of refrigerant samples, affirming its reliability in diverse operational environments. Its design minimizes contamination risks during sampling and provides detailed composition results within 90 seconds, ensuring efficient and precise analysis. With a projected price point under $150, the proposed solution delivers affordability alongside its lightweight portability and straightforward operation. Unlike complex and costly alternatives, such as gas chromatography systems, this device provides an accessible option for technicians, customs personnel, and industry operators in need of quick and effective refrigerant verification. Compatible with both current formulations and emerging refrigerant technologies, the device addresses critical counterfeit detection needs across a range of applications. By delivering accurate composition analysis and counterfeit identification, this innovation enhances system performance, safety, and operational reliability in crucial industries.

Cheekatamarla, Praveen [ORNL] (ORCID:0000000248827↗

DICER: A new instrument at LANSCE to constrain neutron capture rates on radionuclides

With very few exceptions, direct measurements of neutron capture rates on radionuclides have not been possible. A number of indirect methods have been pursued such as the surrogate method, the γ-ray strength function method, the Oslo method and the β-Oslo method. Substantial effort has been devoted to quantify the usually large systematic errors that accompany the results from these techniques. A new instrument has been developed at the Los Alamos Neutron Science Center (LANSCE) to provide more accurate data on several radionuclides relevant to nuclear criticality safety, radiochemical diagnostics, astrophysics, nuclear forensics and nuclear security, by measuring the transmission of neutrons through radioactive samples and studying resonance properties. The Device for Indirect Capture on Radionuclides (DICER) and associated radionuclide production at the Isotope Production Facility (IPF), both at LANSCE, as well radioactive sample fabrication, have been under development the last few years. A description of the new apparatus, data on a few mid-weight stable isotopes and efforts on radionuclide measurements will be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

X ray analysis of balloon-collected particles erroneously considered as an October influx into the lower stratosphere

Individual particles were analyzed on the collection screens in a Jeolco scanning electron microscope using a Kevex Li-drifted silicon energy dispersive X ray detector. It was found that the bulk of the stratospheric samples studied comes from explosive squib devices. It is pointed out that this finding does not invalidate the extensive results obtained by Bigg et al. (1970, 1971) in previous sampling experiments.

Farlow, N. H.↗

Ferromagnetism Near Room Temperature in the Cleavable van der Waals Crystal Fe 5 GeTe 2

Two-dimensional materials with intrinsic functionality are becoming increasingly important in exploring fundamental condensed matter science and for developing advanced technologies. Bulk crystals that can be exfoliated are particularly relevant to these pursuits as they provide the opportunity to study the role of physical dimensionality and explore device physics in highly crystalline samples and designer heterostructures in a routine manner. Magnetism is a key element in these endeavors; however, relatively few cleavable materials are magnetic and none possess magnetic order at ambient conditions. Here, we introduce Fe 5–x GeTe 2 as a cleavable material with ferromagnetic behavior at room temperature. We established intrinsic magnetic order at room temperature in bulk crystals ( = 310 K) through magnetization measurements and in exfoliated, thin flakes (T C ≈ 280 K) using the anomalous Hall effect. Our work reveals Fe 5 GeTe 2 as a prime candidate for incorporating intrinsic magnetism into functional van der Waals heterostructures and devices near room temperature.

36 MATERIALS SCIENCE↗

In-flight friction and wear mechanism

A unique mechanism developed for conducting friction and wear experiments in orbit is described. The device is capable of testing twelve material samples simultaneously. Parameters considered critical include: power, weight, volume, mounting, cleanliness, and thermal designs. The device performed flawlessly in orbit over an eighteen month period and demonstrated the usefulness of this design for future unmanned spacecraft or shuttle applications.

Devine, E. J.↗

Laser-induced fluorescence fiber optic probe measurement of oil dilution by fuel

Apparatus for detecting fuel in oil includes an excitation light source in optical communication with an oil sample for exposing the oil sample to excitation light in order to excite the oil sample from a non-excited state to an excited state and a spectrally selective device in optical communication with the oil sample for detecting light emitted from the oil sample as the oil sample returns from the excited state to a non-excited state to produce spectral indicia that can be analyzed to determine the presence of fuel in the oil sample. A method of detecting fuel in oil includes the steps of exposing a oil sample to excitation light in order to excite the oil sample from a non-excited state to an excited state, as the oil sample returns from the excited state to a non-excited state, detecting light emitted from the oil sample to produce spectral indicia; and analyzing the spectral indicia to determine the presence of fuel in the oil sample.

Parks, II, James E↗

Digitization of scalar fields for quantum computing

Qubit, operator, and gate resources required for the digitization of lattice λΦ 4 scalar field theories onto quantum computers are considered, building upon the foundational work by Jordan et al. [Quantum Inf. Comput. 14, 1014 (2014); Science 336, 1130 (2012)], with a focus towards noisy intermediate-scale quantum devices. The Nyquist-Shannon sampling theorem, introduced in this context by Macridin et al. [Phys. Rev. A 98, 042312 (2018)] building on the work of Somma [Quantum Inf. Comput. 16, 1125 (2016)], provides a guide with which to evaluate the efficacy of two field-space bases, the eigenstates of the field operator, as used by Jordan et al., and eigenstates of a harmonic oscillator, to describe ( 0 + 1 )- and ( d + 1 )-dimensional scalar field theory. We show how techniques associated with improved actions, which are heavily utilized in lattice QCD calculations to systematically reduce lattice-spacing artifacts, can be used to reduce the impact of the field digitization in λΦ 4 , but are found to be inferior to a complete digitization improvement of the Hamiltonian using a quantum Fourier transform. When the Nyquist-Shannon sampling theorem is satisfied, digitization errors scale as | log | log | ε dig | | | ~ n Q (number of qubits describing the field at a given spatial site) for the low-lying states, leaving the familiar power-law lattice-spacing and finite-volume effects that scale as | log | ε latt | | ~ N Q (total number of qubits in the simulation). For localized (delocalized) field-space wave functions, it is found that n Q ~ 4 ( 7 ) qubits per spatial lattice site are sufficient to reduce theoretical digitization errors below error contributions associated with approximation of the time-evolution operator and noisy implementation on near-term quantum devices. Only classical computing resources have been used to obtain the results presented in this work.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

IR-Live: fabrication of a low-cost plastic microfluidic device for infrared spectromicroscopy of living cells

Water is a strong mid-infrared absorber, which has hindered the full exploitation of label-free and non-invasive infrared (IR) spectromicroscopy techniques for the study of living biological samples. To overcome this barrier, many researchers have built sophisticated fluidic chambers or microfluidic chips wherein the depth of the liquid medium in the sample compartment is limited to 10 μm or less. We report an innovative and simple way to fabricate plastic devices with infrared transparent view-ports enabling infrared spectromicroscopy of living biological samples; therefore the device is named “IR-Live”. Advantages of this approach include lower production costs, a minimal need to access a micro-fabrication facility, and unlimited mass or waste exchange for the living samples surrounding the view-port area. We demonstrate that the low-cost IR-Live in combination with microfluidic perfusion techniques enables long term (>60 h) cell culture, which broadens the capability of IR spectromicroscopy for studying living biological samples. To illustrate this, we first applied the device to study protein and lipid polarity in migrating REF52 fibroblasts by collecting 2-dimensional spectral chemical maps at a micrometer spatial resolution. Then, we demonstrated the suitability of our approach to study dynamic cellular events by collecting a time series of spectral maps of U937 monocytes during the early stage of cell attachment to a bio-compatible surface.

47 OTHER INSTRUMENTATION↗

Resistive switching: An investigation of the bipolar–unipolar transition in Co-doped ZnO thin films

Highlights: • A purely bipolar behavior on a Co-doped ZnO thin film has been demonstrated. • We have shown what can happen if a unipolar test is performed in a purely bipolar device. • An explanation for how a sample can show a purely bipolar switching behavior was suggested. • An important open issue about resistive switching effect was put in debate. - Abstract: In order to investigate the resistive switching effect we built devices in a planar structure in which two Al contacts were deposited on the top of the film and separated by a small gap using a shadow mask. Therefore, two samples of 10% Co-doped ZnO thin films were sputtered on glass substrate. High resolution X-ray diffraction (HRXRD) revealed a highly c-axis oriented crystalline structure, without secondary phase. The high resolution scanning electron microscopy (HRSEM) showed a flat surface with good coverage and thickness about 300 nm. A Keithley 2425 semiconductor characterization system was used to perform the resistive switching tests in the bipolar and unipolar modes. Considering only the effect of compliance current (CC), the devices showed a purely bipolar behavior since an increase in CC did not induce a transition to unipolar behavior.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Adjustable virtual pore-size filter for automated sample preparation using acoustic radiation force

We present a rapid and robust size-based separation method for high throughput microfluidic devices using acoustic radiation force. We developed a finite element modeling tool to predict the two-dimensional acoustic radiation force field perpendicular to the flow direction in microfluidic devices. Here we compare the results from this model with experimental parametric studies including variations of the PZT driving frequencies and voltages as well as various particle sizes and compressidensities. These experimental parametric studies also provide insight into the development of an adjustable 'virtual' pore-size filter as well as optimal operating conditions for various microparticle sizes. We demonstrated the separation of Saccharomyces cerevisiae and MS2 bacteriophage using acoustic focusing. The acoustic radiation force did not affect the MS2 viruses, and their concentration profile remained unchanged. With optimized design of our microfluidic flow system we were able to achieve yields of > 90% for the MS2 with > 80% of the S. cerevisiae being removed in this continuous-flow sample preparation device.

59 BASIC BIOLOGICAL SCIENCES↗

Video-rate terahertz electric-field vector imaging

We present an experimental setup to dramatically reduce a measurement time for obtaining spatial distributions of terahertz electric-field (E-field) vectors. The method utilizes the electro-optic sampling, and we use a charge-coupled device to detect a spatial distribution of the probe beam polarization rotation by the E-field-induced Pockels effect in a 〈110〉-oriented ZnTe crystal. A quick rotation of the ZnTe crystal allows analyzing the terahertz E-field direction at each image position, and the terahertz E-field vector mapping at a fixed position of an optical delay line is achieved within 21 ms. Video-rate mapping of terahertz E-field vectors is likely to be useful for achieving real-time sensing of terahertz vector beams, vector vortices, and surface topography. The method is also useful for a fast polarization analysis of terahertz beams.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A high bandwidth microelectromechanical system-based nanopositioner for scanning tunneling microscopy

Limited Z-axis bandwidth of piezotube scanners used in conventional Scanning Tunneling Microscopes (STMs) has been a major limiting factor in achieving high scan speeds in STM applications. Slow Z-axis dynamics of typical piezotube scanners combined with the weight of the STM tip/tip holder assembly, that the scanner has to carry, substantially limit the achievable Z-axis bandwidth in both imaging and lithography modes. To tackle this issue, we introduce a high bandwidth microelectromechanical-system-based nanopositioner to be integrated into an existing STM scanner. The device is designed to replace the STM tip and fine Z-positioning mechanisms in the conventional STM setup, while providing an order of magnitude higher bandwidth in Z axis. The device is microfabricated using double silicon-on-isolator technology, and standard cleanroom processes. Experiments show that tunneling current between the device tip and a highly ordered pyrolytic graphite sample can be successfully established and maintained in air using the proposed device in a feedback loop. Results suggest that the proposed device uniquely combines a very high resolution and a large stroke with a substantially larger Z-axis bandwidth compared to that of conventional STM piezotube scanners, enabling higher scanning speeds in STM operations.

42 ENGINEERING↗

DICER: A new instrument at LANSCE to constrain neutron capture rates on radionuclides

. With very few exceptions, direct measurements of neutron capture rates on radionuclides have not been possible. A number of indirect methods have been pursued such as the surrogate method, the γ-ray strength function method, the Oslo method and the β-Oslo method. Substantial effort has been devoted to quantify the usually large systematic errors that accompany the results from these techniques. A new instrument has been developed at the Los Alamos Neutron Science Center (LANSCE) to provide more accu rate data on several radionuclides relevant to nuclear criticality safety, radiochemical diagnostics, astrophysics, nuclear forensics and nuclear security, by measuring the transmission of neutrons through radioactive samples and studying resonance properties. The Device for Indirect Capture on Radionuclides (DICER) and as sociated radionuclide production at the Isotope Production Facility (IPF), both at LANSCE, as well radioactive sample fabrication, have been under development the last few years. A description of the new apparatus, data on a few mid-weight stable isotopes and efforts on radionuclide measurements will be presented.