Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Reproducibility”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

INVESTIGATING THE CIRCUMSTELLAR DISK OF THE Be SHELL STAR 48 LIBRAE

A global disk oscillation implemented in the viscous decretion disk (VDD) model has been used to reproduce most of the observed properties of the well known Be star ζ Tau. 48 Librae shares several similarities with ζ Tau—they are both early-type Be stars, display shell characteristics in their spectra, and exhibit cyclic V / R variations—but has some marked differences as well, such as a much denser and more extended disk, a much longer V / R cycle, and the absence of the so-called triple-peak features. We aim to reproduce the photometric, polarimetric, and spectroscopic observables of 48 Librae with a self-consistent model, and to test the global oscillation scenario for this target. Our calculations are carried out with the three-dimensional NLTE radiative transfer code HDUST. We employ a rotationally deformed, gravity-darkened central star surrounded by a disk whose unperturbed state is given by the VDD model. A two-dimensional global oscillation code is then used to calculate the disk perturbation and superimpose it on the unperturbed disk. A very good, self-consistent fit to the time-averaged properties of the disk is obtained with the VDD. The calculated perturbation has a period P = 12 years, which agrees with the observed period, and the behavior of the V / R cycle is well reproduced by the perturbed model. The perturbed model improves the fit to the photometric data and reproduces some features of the observed spectroscopic data. Some suggestions to improve the synthesized spectroscopy in a future work are given.

79 ASTRONOMY AND ASTROPHYSICS↗

A Comparison between Physics-based and Polytropic MHD Models for Stellar Coronae and Stellar Winds of Solar Analogs

The development of the Zeeman–Doppler Imaging (ZDI) technique has provided synoptic observations of surface magnetic fields of low-mass stars. This led the stellar astrophysics community to adopt modeling techniques that have been used in solar physics using solar magnetograms. However, many of these techniques have been neglected by the solar community due to their failure to reproduce solar observations. Nevertheless, some of these techniques are still used to simulate the coronae and winds of solar analogs. Here we present a comparative study between two MHD models for the solar corona and solar wind. The first type of model is a polytropic wind model, and the second is the physics-based AWSOM model. We show that while the AWSOM model consistently reproduces many solar observations, the polytropic model fails to reproduce many of them, and in the cases where it does, its solutions are unphysical. Our recommendation is that polytropic models, which are used to estimate mass-loss rates and other parameters of solar analogs, must first be calibrated with solar observations. Alternatively, these models can be calibrated with models that capture more detailed physics of the solar corona (such as the AWSOM model) and that can reproduce solar observations in a consistent manner. Without such a calibration, the results of the polytropic models cannot be validated, but they can be wrongly used by others.

79 ASTRONOMY AND ASTROPHYSICS↗

Photoionization Models for the Inner Gaseous Disks of Herbig Be Stars: Evidence against Magnetospheric Accretion?

We investigate the physical properties of the inner gaseous disks of three hot Herbig B2e stars, HD 76534, HD 114981, and HD 216629, by modeling CFHT-ESPaDOns spectra using non-LTE radiative transfer codes. We assume that the emission lines are produced in a circumstellar disk heated solely by photospheric radiation from the central star in order to test whether the optical and near-infrared emission lines can be reproduced without invoking magnetospheric accretion. The inner gaseous disk density was assumed to follow a simple power-law in the equatorial plane, and we searched for models that could reproduce observed lines of H i (H α and H β ), He i, Ca ii, and Fe ii. For the three stars, good matches were found for all emission line profiles individually; however, no density model based on a single power-law was able to reproduce all of the observed emission lines. Among the single power-law models, the one with the gas density varying as ∼10{sup −10}( R {sub *}/ R ){sup 3} g cm{sup −3} in the equatorial plane of a 25 R {sub *} (0.78 au) disk did the best overall job of representing the optical emission lines of the three stars. This model implies a mass for the H α -emitting portion of the inner gaseous disk of ∼10{sup −9} M {sub *}. We conclude that the optical emission line spectra of these HBe stars can be qualitatively reproduced by a ≈1 au, geometrically thin, circumstellar disk of negligible mass compared to the central star in Keplerian rotation and radiative equilibrium.

79 ASTRONOMY AND ASTROPHYSICS↗

Broadband Photon Spectrum and its Radial Profile of Pulsar Wind Nebulae

The observed radial profiles of the X-ray emission from pulsar wind nebulae (PWNe) have been claimed to contradict the standard 1D steady model. However, the 1D model has not been tested to simultaneously reproduce the volume-integrated spectrum and the radial profile of the surface brightness. We revisit the 1D steady model and apply it to PWNe 3C 58 and G21.5−0.9. We find that the parameters of the pulsar wind, the radius of the termination shock r{sub s}, and magnetization σ greatly affect both the photon spectrum and radial profile of the emission. We have shown that the parameters constrained by the entire spectrum lead to an X-ray nebula smaller than the observed nebula. We have also tested the case that reproduces only the observations in X- and gamma-rays, ignoring the radio and optical components. In this case, there are parameter sets that reproduce both the spectrum and emission profile, but the advection time to the edge of the nebula becomes much smaller than the age. Our detailed discussion clarifies that the standard 1D steady model has severe difficulty to simultaneously reproduce both the volume-integrated spectrum and the surface brightness. This implies that the model should be improved by taking into account extra physical processes such as spatial diffusion of particles. Additionally, we calculate the surface brightness profile of the radio, optical, and TeV gamma-rays. The future observations in these wavelengths are also important to probe the spatial distributions of the relativistic plasma and the magnetic field of PWNe.

79 ASTRONOMY AND ASTROPHYSICS↗

Optical Properties of Non-stoichiometric Amorphous Silicates with Application to Circumstellar Dust Extinction

We determine the optical constants of non-stoichiometric amorphous magnesium-iron silicates and demonstrate that they can well reproduce the observed mid-infrared emission spectra of evolved stars. Stoichiometric and non-stoichiometric amorphous magnesium-iron silicate films are fabricated by pulsed laser deposition. Transmittance and ellipsometry measurements are performed in the wavelength range between 2 and 200 μm and 1.7 and 33 μm, respectively. Optical constants are derived from transmittance and ellipsometric Ψ and Δ spectra by means of oscillator models. These newly obtained optical constants are applied in radiative transfer models for examining reproducibility of the observed spectral features of circumstellar dust shells around supergiants. The spectra of four selected supergiants are dominated by amorphous silicate dust emission in the wavelength range between 9 and 25 μm. To obtain a good fit to the observed spectra, we take into account amorphous corundum and metallic iron particles as additional dust components to the model calculations to rationalize the dust emission at λ<8 μm. For each of the objects, a set of model parameters (dust mass and condensation temperature) is derived by an automated optimization procedure that reproduces the observation well. Consequently, our model spectra using new optical data reveal that the silicate bands at ∼10 and ∼18 μm depend on the magnesium and iron ratio in the silicate system, and that a good fit requires a significant iron content of the amorphous silicate dust component to reproduce the observed peak positions and shape of the silicate bands.

79 ASTRONOMY AND ASTROPHYSICS↗

Results from a multi-laboratory ocean metaproteomic intercomparison: effects of LC-MS acquisition and data analysis procedures

Metaproteomics is an increasingly popular methodology that provides information regarding the metabolic functions of specific microbial taxa and has potential for contributing to ocean ecology and biogeochemical studies. A blinded multi-laboratory intercomparison was conducted to assess comparability and reproducibility of taxonomic and functional results and their sensitivity to methodological variables. Euphotic zone samples from the Bermuda Atlantic Time-series Study (BATS) in the North Atlantic Ocean collected by in situ pumps and the autonomous underwater vehicle (AUV) Clio were distributed with a paired metagenome, and one-dimensional (1D) liquid chromatographic data-dependent acquisition mass spectrometry analysis was stipulated. Analysis of mass spectra from seven laboratories through a common bioinformatic pipeline identified a shared set of 1056 proteins from 1395 shared peptide constituents. Quantitative analyses showed good reproducibility: pairwise regressions of spectral counts between laboratories yielded R 2 values averaged 0.62±0.11, and a Sørensen similarity analysis of the top 1000 proteins revealed 70 %–80 % similarity between laboratory groups. Taxonomic and functional assignments showed good coherence between technical replicates and different laboratories. A bioinformatic intercomparison study, involving 10 laboratories using eight software packages, successfully identified thousands of peptides within the complex metaproteomic datasets, demonstrating the utility of these software tools for ocean metaproteomic research. Lessons learned and potential improvements in methods were described. Future efforts could examine reproducibility in deeper metaproteomes, examine accuracy in targeted absolute quantitation analyses, and develop standards for data output formats to improve data interoperability. Together, these results demonstrate the reproducibility of metaproteomic analyses and their suitability for microbial oceanography research, including integration into global-scale ocean surveys and ocean biogeochemical models.

59 BASIC BIOLOGICAL SCIENCES↗

An open-source computational and data resource to analyze digital maps of immunopeptidomes

We present a novel proteomics-based workflow and an open source data and computational resource for reproducibly identifying and quantifying HLA-associated peptides at high-throughput. The provided resources support the generation of HLA allele-specific peptide assay libraries consisting of consensus fragment ion spectra and the analysis of quantitative digital maps of HLA peptidomes generated by SWATH mass spectrometry (MS). This is the first community-based study towards the development of a robust platform for the reproducible and quantitative measurement of HLA peptidomes, an essential step towards the design of efficient immunotherapies.

Environmental Molecular Sciences Laboratory↗

Toward the Neutrino Discovery Platform: An Auditable, Uncertainty-Bearing Toolchain for MINERvA Open-Data Cross-Section Analysis

The Neutrino Discovery Platform (NDP) aims to accelerate DUNE-era science by making the neutrino program's existing datasets analyzable through fast, reproducible, and auditable workflows. We report a working version of two of its layers, data curation and agentic orchestration, built and tested end to end on MINERvA open data. The guiding lesson throughout is that a cross section is a measurement, and not just a plotted shape, only if it carries a defensible systematic-uncertainty budget, a trustworthy unfolding, and a reproducible record. Using a single medium-energy playlist pair from the MINERvA open-data release (about $2.05\times10^{17}$ protons on target of data), we first reproduced the shapes of two published charged-current inclusive $\nu_\mu$ measurements through a complete extraction ladder: selection, background subtraction, D'Agostini unfolding, efficiency correction, and flux normalization. These shape-level reproductions ran and tracked the published results, but they lacked the systematic-uncertainty machinery that defines a MINERvA cross section. To supply it, we vendored and built the MINERvA Analysis Toolkit and developed a many-universe systematic-uncertainty tool that produces a portable covariance artifact, a parallel event-loop runner, and a per-run auditability harness. Validated against a published covariance release, the toolchain reproduces the released statistical, flux, and muon-energy-scale terms and shows that they account for roughly 63\% of the total variance, with the remainder unreleased. Using this same infrastructure, we then performed a measurement of our own design, the hadronic recoil-energy distribution of low-energy ($E_\nu<2.5$~GeV) charged-current inclusive events, and found data/simulation shape agreement of $\chi^2/\mathrm{ndf}=1.26$. Together these results show that the platform supports original physics and not only reproductions.

Breaux, Auto [Tulane U. (main)]↗

The influence of model resolution on the simulated sensitivity of North Atlantic tropical cyclone maximum intensity to sea surface temperature

Global climate models (GCMs) are routinely relied upon to study the possible impacts of climate change on a wide range of meteorological phenomena, including tropical cyclones (TCs). Previous studies addressed whether GCMs are capable of reproducing observed TC frequency and intensity distributions. This research builds upon earlier studies by examining how well GCMs capture the physically relevant relationship between TC intensity and SST. Specifically, the influence of model resolution on the ability of a GCM to reproduce the sensitivity of simulated TC intensity to SST is examined for the MRI-AGCM (20 km), the GFDL-HiRAM (50 km), the FSU-COAPS (0.94°) model, and two versions of the CAM5 (1° and 0.25°). Results indicate that while a 1°C increase in SST corresponds to a 5.5–7.0 m s -1 increase in observed maximum intensity, the same 1°C increase in SST is not associated with a statistically significant increase in simulated TC maximum intensity for any of the models examined. However, it also is shown that the GCMs all capably reproduce the observed sensitivity of potential intensity to SST. The models generate the thermodynamic environment suitable for the development of strong TCs over the correct portions of the Nort h Atlantic basin, but strong simulated TCs do not develop over these areas, even for models that permit Category 5 TCs. This result supports the notion that direct simulation of TC eyewall convection is necessary to accurately represent TC intensity and intensification processes in climate models, although additional explanations are also explored.

54 ENVIRONMENTAL SCIENCES↗

Hydrodynamic injection with pneumatic valving for microchip electrophoresis with total analyte utilization

A novel hydrodynamic injector that is directly controlled by a pneumatic valve has been developed for reproducible microchip capillary electrophoresis (CE) separations. The poly(dimethylsiloxane) (PDMS) devices used for evaluation comprise a separation channel, a side channel for sample introduction, and a pneumatic valve aligned at the intersection of the channels. A low pressure (≤ 3 psi) applied to the sample reservoir is sufficient to drive sample into the separation channel. The rapidly actuated pneumatic valve enables injection of discrete sample plugs as small as ~100 pL for CE separation. The injection volume can be easily controlled by adjusting the intersection geometry, the solution back pressure and the valve actuation time. Sample injection could be reliably operated at different frequencies (< 0.1 Hz to >2 Hz) with good reproducibility (peak height relative standard deviation ≤ 3.6%) and no sampling biases associated with the conventional electrokinetic injections. The separation channel was dynamically coated with a cationic polymer, and FITC-labeled amino acids were employed to evaluate the CE separation. Highly efficient (≥ 7.0 × 103 theoretical plates for the ~2.4 cm long channel) and reproducible CE separations were obtained. The demonstrated method has numerous advantages compared with the conventional techniques, including repeatable and unbiased injections, no sample waste, high duty cycle, controllable injected sample volume, and fewer electrodes with no need for voltage switching. The prospects of implementing this injection method for coupling multidimensional separations, for multiplexing CE separations and for sample-limited bioanalyses are discussed.

59 BASIC BIOLOGICAL SCIENCES↗

The cardiac dose-sparing benefits of deep inspiration breath-hold in left breast irradiation: a systematic review

Despite technical advancements in breast radiation therapy, cardiac structures are still subject to significant levels of irradiation. As the use of adjuvant radiation therapy after breast-conserving surgery continues to improve survival for early breast cancer patients, the associated radiation-induced cardiac toxicities become increasingly relevant. Our primary aim was to evaluate the cardiac-sparing benefits of the deep inspiration breath-hold (DIBH) technique. An electronic literature search of the PubMed database from 1966 to July 2014 was used to identify articles published in English relating to the dosimetric benefits of DIBH. Studies comparing the mean heart dose of DIBH and free breathing treatment plans for left breast cancer patients were eligible to be included in the review. Studies evaluating the reproducibility and stability of the DIBH technique were also reviewed. Ten studies provided data on the benefits of DIBH during left breast irradiation. From these studies, DIBH reduced the mean heart dose by up to 3.4 Gy when compared to a free breathing approach. Four studies reported that the DIBH technique was stable and reproducible on a daily basis. According to current estimates of the excess cardiac toxicity associated with radiation therapy, a 3.4 Gy reduction in mean heart dose is equivalent to a 13.6% reduction in the projected increase in risk of heart disease. DIBH is a reproducible and stable technique for left breast irradiation showing significant promise in reducing the late cardiac toxicities associated with radiation therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Detection and analysis of cyclotrimethylenetrinitramine (RDX) in environmental samples by surface-enhanced Raman spectroscopy

Techniques for rapid and sensitive detection of energetics such as cyclotrimethylenetrinitramine (RDX) are needed both for environmental and security screening applications. Here we report the use of surface-enhanced Raman scattering (SERS) spectroscopy to detect traces of RDX with good sensitivity and reproducibility. Using gold (Au) nanoparticles ( 90 100 nm in diameter) as SERS substrates, RDX was detectable at concentrations as low as 0.15 mg/l in a contaminated groundwater sample. This detection limit is about two orders of magnitude lower than those reported previously using SERS techniques. A surface enhancement factor of 6 104 was obtained. This research further demonstrates the potential for using SERS as a rapid, in situ field screening tool for energetics detection when coupled with a portable Raman spectrometer.

54 ENVIRONMENTAL SCIENCES↗

Anomalous structural recovery in the near glass transition range in a polymer glass: Data revisited in light of temperature variability in vacuum oven‐based experiments*

Abstract There is considerable interest in data reported by Cangialosi et al. [Cangialosi, D., Boucher, V. M., Alegría, A., & Colmenero, J. (2013). Physical Review Letters , 111 (9), 095701] that purportedly showed unusual irregular responses in the isothermal structural recovery behavior of glasses because the observation challenges the general view of the dynamics being smooth functions of time as observed in extensive dilatometric experiments by Kovacs [Kovacs, A. J. (1964). In Fortschritte der Hochpolymeren‐Forschung , 3 , 394–507. Springer, Berlin, Heidelberg.] in the 1960s. The reported data show an apparent two mechanism structural (enthalpy) recovery at aging temperatures ranging from 6 to 17 K below which is also controversial as it could not be reproduced in work from Koh and Simon [Koh, Y. P., & Simon, S. L. (2013). Macromolecules , 46(14), 5815–5821.] where a second plateau observed in the enthalpy loss curve was not reproduced in nearly 1‐year‐long experiments at 15 K below . Therefore, it is important to determine what might be possible reasons for the apparent non‐smooth relaxations. Here, we examine the possibility that the poor temperature control of a typical vacuum oven could explain the anomalous results. We used the Tool–Narayanaswamy–Moynihan (TNM) model of structural recovery to calculate the effect of typical vacuum oven temperature variation on the structural recovery of polystyrene and find that we can reproduce the reported experimental results. The issue of temperature control using a vacuum oven is discussed, and data from thermocouple measurements of temperature at various locations inside a vacuum oven are shown.

36 MATERIALS SCIENCE↗

Isotopic analysis of sub-nanogram neodymium loads using new ATONA™ amplifiers

The long-term gains of the ATONA™ amplifiers are shown to have less than 1 ppm variability. Repeat measurements of the JNdi-1 reference material demonstrate the ability of the ATONA™ amplification technology to make measurements of 143 Nd/ 144 Nd ratios with 23 ppm external reproducibility on 100-pg loads. The effect of increasing integration time on analytical reproducibility is also displayed as increasing integration time from 10 to 30s reduced the external measurement uncertainty from 37 to 23 ppm. These measurements represent an improvement of more than a factor of 3 in external measurement reproducibility relative to previously published 143 Nd/ 144 Nd measurements of 100-pg loads. Furthermore, this new technology will allow for the measurement of smaller samples for precise isotope ratios and open new avenues of research in the geological and nuclear forensic communities.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Logarithmic accuracy of parton showers: a fixed-order study

We formulate some first fundamental elements of an approach for assessing the logarithmic accuracy of parton-shower algorithms based on two broad criteria: their ability to reproduce the singularity structure of multi-parton matrix elements, and their ability to reproduce logarithmic resummation results. We illustrate our approach by considering properties of two transverse-momentum ordered final-state showers, examining features up to second order in the strong coupling. In particular we identify regions where they fail to reproduce the known singular limits of matrix elements. Here, the characteristics of the shower that are responsible for this also affect the logarithmic resummation accuracies of the shower, both in terms of leading (double) logarithms at subleading N C and next-to-leading (single) logarithms at leading N C .

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Treatment Planning and Volumetric Response Assessment for Yttrium-90 Radioembolization: Semiautomated Determination of Liver Volume and Volume of Tumor Necrosis in Patients with Hepatic Malignancy

Purpose: The primary purpose of this study was to demonstrate intraobserver/interobserver reproducibility for novel semiautomated measurements of hepatic volume used for Yttrium-90 dose calculations as well as whole-liver and necrotic-liver (hypodense/nonenhancing) tumor volume after radioembolization. The secondary aim was to provide initial comparisons of tumor volumetric measurements with linear measurements, as defined by Response Evaluation Criteria in Solid Tumors criteria, and survival outcomes. Methods: Between 2006 and 2009, 23 consecutive radioembolization procedures were performed for 14 cases of hepatocellular carcinoma and 9 cases of hepatic metastases. Baseline and follow-up computed tomography obtained 1 month after treatment were retrospectively analyzed. Three observers measured liver, whole-tumor, and tumor-necrosis volumes twice using semiautomated software. Results: Good intraobserver/interobserver reproducibility was demonstrated (intraclass correlation [ICC] > 0.9) for tumor and liver volumes. Semiautomated measurements of liver volumes were statistically similar to those obtained with manual tracing (ICC = 0.868), but they required significantly less time to perform (p < 0.0001, ICC = 0.088). There was a positive association between change in linear tumor measurements and whole-tumor volume (p < 0.0001). However, linear measurements did not correlate with volume of necrosis (p > 0.05). Dose, change in tumor diameters, tumor volume, and necrotic volume did not correlate with survival (p > 0.05 in all instances). However, Kaplan-Meier curves suggest that a >10% increase in necrotic volume correlated with survival (p = 0.0472). Conclusion: Semiautomated volumetric analysis of liver, whole-tumor, and tumor-necrosis volume can be performed with good intraobserver/interobserver reproducibility. In this small retrospective study, measurements of tumor necrosis were suggested to correlate with survival.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Large Scale Production of Magnetic Nanoparticles Using Bacterial Fermentation

Microbial production of nano-sized particles has a demonstrated capacity to make highly crystalline pure phase magnetite or with some substitution of Fe by Co, Ni, Cr, Mn, Zn or the rare earths. Microbial production of magnetic nanoparticles can be achieved in large quantities and at low cost. Over 1 kg (wet weight) of Zn-substituted magnetite (nominal composition of Zn0.6Fe2.4O4) has been recovered from 30 L fermentations. Transmission electron microscopy (TEM) was used to confirm that this mass produced extracellular magnetites exhibited good mono-dispersity. TEM results also showed a highly reproducible particle size and corroborated average crystallite size (ACS) of 13.1 0.8 nm determined through X-ray diffraction (N=7) at a 99 % confidence level. Based on scale-up experiments performed using a 35 L reactor, the increase in ACS reproducibility may be attributed to an increase of electron donor input, availability of divalent substitution metal ions and less ferrous ions in the case of substituted magnetite, increased reactor volume overcoming differences in each batch, or a combination of the above. While costs of commercial nanometer sized magnetite (25-50 nm) may cost $500/kg, microbial production is likely capable of producing 5-90 nm pure or substituted magnetites at a fraction of the cost of traditional chemical synthesis. While there are numerous approaches for the synthesis of nanoparticles, bacterial fermentation of magnetite or metal-substituted magnetite may represent an advantageous manufacturing technology with respect to yield, reproducibility and scalable synthesis with low costs at low energy input.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗