Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Reference Values”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

The Effect of Carboxyl Group Content on Water Uptake Capacity and Tensile Properties of Functionalized Soy Protein-Based Superabsorbent Plastics

This manuscript studies the relation between macroscopic properties of the soy protein isolate (SPI)-based superabsorbent polymers (SAP) (e.g., water uptake capacity and tensile properties) and the extent of chemical modification conducted on the protein. The increase in the carboxyl group content, obtained from electrometric titrations, for acylated systems compared to native SPI brings with it an improvement in the protein hydrophilic character, as revealed by the determination of the water imbibing capacity. SEM images show that larger porous regions were developed in the acylated plastics. As for their mechanical properties, static tensile measurements indicated that acylated plastics with greater water uptake values display higher extensibility, compared to the reference sample. These natural-based SAP materials could be appropriate for applications in which maintaining the dimensional stability during service is not crucial (e.g. in agriculture and horticulture).

36 MATERIALS SCIENCE↗

Effects of Laser-Cutting and Spark Erosion Techniques and Heat Treatment on the Magnetic Properties of Grain-Oriented Transformer Steels

Spark erosion and laser-cutting processes were examined in terms of their effects on the magnetic properties of grain-oriented electrical steels at working frequencies. The maximum permeability value in each case was considered a reference to determine the quantitative effect of cutting and eroding methods as well as the effects of heat treatment. To minimize the deterioration that appears after the piercing process is implemented, the specimens were subjected to heat treatment at the most appropriate temperature. The influence of stress-relief annealing could be observed throughout the domain refinement on the surface by using magneto-optical Kerr microscopy. Additionally, it was clearly seen that the domain contrast at the cut edge of the spark-eroded sample was more uniform than that provided by laser cutting upon applying a high AC-field amplitude.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Development of a Thermal Transport Database for Air Plasma Sprayed ZrO2 ? Y2O3 Thermal Barrier Coatings

Thermal Diffusivities of Air Plasma Sprayed (APS) thermal barrier coatings (TBCs) are measured by the laser flash method. The data are used to calculate thermal conductivity of TBCs when provided with density and specific heat data. Due to the complicated microstructure and other processing related parameters, thermal diffusivity of TBCs can vary as much as three to four fold. Data collected from over 200 free-standing ZrO2 7-8 wt%Y2O3 TBCs are presented. The large database gives a clear picture of the expected band of thermal diffusivity values. When this band is used as reference for thermal diffusivity of a specific TBC, the thermal transport property of TBC can be more precisely described. The database is intended to serve researchers and manufacturers of TBCs as a valuable source for evaluating their coatings.

36 MATERIALS SCIENCE↗

Convective heat transfer to CO{sub 2} at a supercritical pressure flowing vertically upward in tubes and an annular channel

The Super-Critical Water-Cooled Reactor (SCWR) has been chosen by the Generation IV International Forum as one of the candidates for the next generation nuclear reactors. Heat transfer to water from a fuel assembly may deteriorate at certain supercritical pressure flow conditions and its estimation at degraded conditions as well as in normal conditions is very important to the design of a safe and reliable reactor core. Extensive experiments on a heat transfer to a vertically upward flowing CO{sub 2} at a supercritical pressure in tubes and an annular channel have been performed. The geometries of the test sections include tubes of an internal diameter (ID) of 4.4 and 9.0 mm and an annular channel (8 x 10 mm). The heat transfer coefficient (HTC) and Nusselt numbers were derived from the inner wall temperature converted by using the outer wall temperature measured by adhesive K-type thermocouples and a direct (tube) or indirect (annular channel) electric heating power. From the test results, a correlation, which covers both a deteriorated and a normal heat transfer regime, was developed. The developed correlation takes different forms in each interval divided by the value of parameter Bu. The parameter Bu (referred to as Bu hereafter), a function of the Grashof number, the Reynolds number and the Prandtl number, was introduced since it is known to be a controlling factor for the occurrence of a heat transfer deterioration due to a buoyancy effect. The developed correlation predicted the HTCs for water and HCFC-22 fairly well. (author)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Second Harmonic Generation Electric Field Triplet Interferometry for Absolute Phasing

We report second harmonic generation (SHG) electric field triplet interferometry performed using three mutually coherent ultrafast pulses in a common path with controllable relative phases, namely, the light fields of a sample signal (SI), a reference oscillator (RO), and a local oscillator (LO). The ROLO phase determined from the interference of the light fields produced by two quartz wafers is subtracted from the phase determined from the SIROLO interferogram to yield the signal phase, ϕ SI . The new method also calibrates the measured SHG intensity from a given sample internally by sending the fundamental light field reflected from the sample into one of the quartz wafers in the ROLO element. The approach avoids having to exchange the sample against a reference material with a known χ(2) value or known phase and accounts on-the-fly for situations where the reflected fundamental light field intensity changes with experimental conditions. The new method is successfully benchmarked against z-cut α-quartz, fused silica held at its point of zero charge, and hematite nanolayers in air, across three different interferometers. Furthermore, the approach should be applicable for other second-order nonlinear spectroscopies, such as vibrational or electronic sum-frequency generation.

Interfaces↗

Cross-correlation based time delay estimation for turbulent flow velocity measurements: Statistical considerations

Time delay estimation methods (TDE) are well-known techniques to investigate poloidal flows in hot magnetized plasmas through the propagation properties of turbulent structures in the medium. One of these methods is based on the estimation of the time lag at which the cross-correlation function (CCF) estimation reaches its maximum value. The uncertainty of the peak location refers to the smallest determinable flow velocity modulation, and therefore the standard deviation of the time delay imposes important limitation to the measurements. In this article, the relative standard deviation of the CCF estimation and the standard deviation of its peak location are calculated analytically using a simple model of turbulent signals. This model assumes independent (non interacting) overlapping events (coherent structures) with randomly distributed spatio-temporal origins moving with background flow. The result of our calculations is the derivation of a general formula for the CCF variance, which is valid not exclusively in the high event density limit, but also for arbitrary event densities. Our formula reproduces the well known expression for high event densities previously published in the literature. In this paper we also present a derivation of the variance of time delay estimation that turns out to be inversely proportional to the applied time window. The derived formulas were tested in real plasma measurements. The calculations are an extension of the earlier work of Bencze and Zoletnik [Phys. Plasmas 12, 052323 (2005)] where the autocorrelation-width technique was developed. Additionally, we show that velocities calculated by a TDE method possess a broadband noise which originates from this variance, its power spectral density cannot be decreased by worsening the time resolution and can be coherent with noises of other velocity measurements where the same turbulent structures are used. This noise should not be confused with the impact of zero mean frequency zonal flow modulations and can be the explanation for the TEXTOR velocity spectra measured by beam emission spectroscopy.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Non-invasive low charge electron beam time-of-arrival diagnostic using a plasmonics-enhanced photoconductive antenna

The use of a plasmonics-enhanced photoconductive antenna (PCA) optically gated by a near infrared (NIR) pulse enables non-invasive time-of-arrival measurements of a low charge electron beam with respect to the NIR reference, achieving picosecond resolution. The measured signal values show the expected scaling with the beam charge and distance from PCA to the beam axis, as the PCA samples the electric field of the passing electron beam. We operate the device with an NIR spot size much larger than the PCA active-area, resulting in a very simple optical setup and alignment procedure, making the plasmonics-enhanced PCA a preferred alternative to more complex timing diagnostics for applications requiring non-invasive picosecond or sub-picosecond timestamping.

43 PARTICLE ACCELERATORS↗

Neutron Multiplicity Counting Moments for Fissile Mass Estimation in Scatter-Based Neutron Detection Systems

Neutron multiplicity counting (NMC) techniques are widely used for nuclear materials accountability and international safeguards applications to quantitatively evaluate characteristic properties pertaining to fissile material. Mathematical models for NMC moments have been previously derived for systems that use capture-based detectors; however, these models are not applicable when scatter-based detectors are used because of “neutron cross talk.” Neutron cross talk occurs when a single neutron scatters and deposits energy above threshold into multiple detectors causing spurious increase in multiplicity counts; this, in turn, has caused fissile mass to be overestimated when not treated. In this paper, we propose new mathematical models derived from point kinetics to correct for neutron cross-talk effects up to any arbitrary order N, where N denotes the maximum number of counts a single neutron can cause. The new models were used to estimate the fissile mass of plutonium metal and oxide samples with effective 240 Pu mass ranging from 2.5 to 250 g. The adequacy of the models was confirmed using simulations of a conceptual scatter-based neutron multiplicity counter (e.g., organic scintillators) using MCNPX v2.7e with the PoliMi fission event generating extension. The fissile mass estimates with no correction for neutron cross-talk events yielded an average relative deviation from the true 240 Pu eff mass of 55.94% and 84.56% for metal and oxide samples, respectively. When neutron cross-talk events of order N = 2 are included in the model, the fissile mass estimates yielded an average relative deviation of 11.89% for metal and 13.21% for oxide samples. Accounting for neutron cross-talk events of order N = 3 resulted in fissile mass estimates with an average relative deviation of 9.58% and 10.51% for metal and oxide samples, respectively. These mass estimates were compared to a reference case (i.e., no neutron crosstalk effects) that yielded an average relative deviation of 6.81% and 4.77% for metal and oxide samples, respectively. In conclusion, the discrepancy between the estimates from the proposed model and the reference case is attributed to the assumed value of N, which sets a finite upper bound on the order of cross-talk events the model treats (i.e., the model for N = 3 assumes that a neutron will never cause more than three counts).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effects of sparse sampling schemes on image quality in low-dose CT

Purpose: Various scanning methods and image reconstruction algorithms are actively investigated for low-dose computed tomography (CT) that can potentially reduce a health-risk related to radiation dose. Particularly, compressive-sensing (CS) based algorithms have been successfully developed for reconstructing images from sparsely sampled data. Although these algorithms have shown promises in low-dose CT, it has not been studied how sparse sampling schemes affect image quality in CS-based image reconstruction. In this work, the authors present several sparse-sampling schemes for low-dose CT, quantitatively analyze their data property, and compare effects of the sampling schemes on the image quality.Methods: Data properties of several sampling schemes are analyzed with respect to the CS-based image reconstruction using two measures: sampling density and data incoherence. The authors present five different sparse sampling schemes, and simulated those schemes to achieve a targeted dose reduction. Dose reduction factors of about 75% and 87.5%, compared to a conventional scan, were tested. A fully sampled circular cone-beam CT data set was used as a reference, and sparse sampling has been realized numerically based on the CBCT data.Results: It is found that both sampling density and data incoherence affect the image quality in the CS-based reconstruction. Among the sampling schemes the authors investigated, the sparse-view, many-view undersampling (MVUS)-fine, and MVUS-moving cases have shown promising results. These sampling schemes produced images with similar image quality compared to the reference image and their structure similarity index values were higher than 0.92 in the mouse head scan with 75% dose reduction.Conclusions: The authors found that in CS-based image reconstructions both sampling density and data incoherence affect the image quality, and suggest that a sampling scheme should be devised and optimized by use of these indicators. With this strategic approach, one can acquire optimally sampled sparse data so that the CS-based algorithms can best perform in terms of image quality.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-T-398: Evaluation of Radiobiological Parameters Using Serial Tumor Imaging During Radiotherapy as An Inverse Ill-Posed Problem

Purpose: Combination of serial tumor imaging with radiobiological modeling can provide more accurate information on the nature of treatment response and what underlies resistance. The purpose of this article is to improve the algorithms related to imaging-based radiobilogical modeling of tumor response. Methods: Serial imaging of tumor response to radiation therapy represents a sum of tumor cell sensitivity, tumor growth rates, and the rate of cell loss which are not separated explicitly. Accurate treatment response assessment would require separation of these radiobiological determinants of treatment response because they define tumor control probability. We show that the problem of reconstruction of radiobiological parameters from serial imaging data can be considered as inverse ill-posed problem described by the Fredholm integral equation of the first kind because it is governed by a sum of several exponential processes. Therefore, the parameter reconstruction can be solved using regularization methods. Results: To study the reconstruction problem, we used a set of serial CT imaging data for the head and neck cancer and a two-level cell population model of tumor response which separates the entire tumor cell population in two subpopulations of viable and lethally damage cells. The reconstruction was done using a least squared objective function and a simulated annealing algorithm. Using in vitro data for radiobiological parameters as reference data, we shown that the reconstructed values of cell surviving fractions and potential doubling time exhibit non-physical fluctuations if no stabilization algorithms are applied. The variational regularization allowed us to obtain statistical distribution for cell surviving fractions and cell number doubling times comparable to in vitro data. Conclusion: Our results indicate that using variational regularization can increase the number of free parameters in the model and open the way to development of more advanced algorithms which take into account tumor heterogeneity, for example, related to hypoxia.

60 APPLIED LIFE SCIENCES↗

SU-E-T-774: Use of a Scintillator-Mirror-Camera System for the Measurement of MLC Leakage Radiation with the CyberKnife M6 System

Purpose: A technique using a scintillator-mirror-camera system to measure MLC leakage was developed to provide an efficient alternative to film dosimetry while maintaining high spatial resolution. This work describes the technique together with measurement uncertainties. Methods: Leakage measurements were made for the InCise™ MLC using the Logos XRV-2020A device. For each measurement approximately 170 leakage and background images were acquired using optimized camera settings. Average background was subtracted from each leakage frame before filtering the integrated leakage image to replace anomalous pixels. Pixel value to dose conversion was performed using a calibration image. Mean leakage was calculated within an ROI corresponding to the primary beam, and maximum leakage was determined by binning the image into overlapping 1mm x 1mm ROIs. 48 measurements were performed using 3 cameras and multiple MLC-linac combinations in varying beam orientations, with each compared to film dosimetry. Optical and environmental influences were also investigated. Results: Measurement time with the XRV-2020A was 8 minutes vs. 50 minutes using radiochromic film, and results were available immediately. Camera radiation exposure degraded measurement accuracy. With a relatively undamaged camera, mean leakage agreed with film measurement to ≤0.02% in 92% cases, ≤0.03% in 100% (for maximum leakage the values were 88% and 96%) relative to reference open field dose. The estimated camera lifetime over which this agreement is maintained is at least 150 measurements, and can be monitored using reference field exposures. A dependency on camera temperature was identified and a reduction in sensitivity with distance from image center due to optical distortion was characterized. Conclusion: With periodic monitoring of the degree of camera radiation damage, the XRV-2020A system can be used to measure MLC leakage. This represents a significant time saving when compared to the traditional film-based approach without any substantial reduction in accuracy.

60 APPLIED LIFE SCIENCES↗

SU-F-T-72: Experimental Determination of the Positionuncertainties for ROOS Ionization Chambers in Clinical Electron Beams

Purpose: National and international dosimetry protocols assume a position accuracy for ionization chambers of less than 0.2mm. To follow this precept the manufacturer PTW-Freiburg introduced a positioning assistance system (TRUFIX) for their particular ion chambers. Aim of this study is an experimental investigation of the positioning uncertainties for ROOS-type ionization chambers. Methods: For all measurements a linear accelerator Elekta Synergie was used. The experiments were performed in a water-phantom. To collimate the electron beam a 10×10cm{sup 2} applicator was installed. All measured depth dose curves were normalized to their maximum. In all cases the TRUFIX system was applied for chamber positioning. For the first measurement series, to determine the positioning reproducibility of a ROOS chamber, one person placed the chamber three times in a 6 MeV electron beam. The mean value of this three measurements was the reference for further six random persons who repeated this procedure. The results were compared for different depths (R{sub 50}, z{sub ref} and R{sub p}). To investigate the impact of different individual chambers of the same type 10 different ROOS chambers were placed by the same person in a 6, 12 and 18MeV electron beam and the measured reference depths z{sub ref} were compared. Results: The absolute positioning reproducibility is less than 0.1mm for the same person. The positioning uncertainties are increasing up to +/−0.3mm if different persons perform the chamber’s positioning within the water phantom. The comparison of the 10 different ROOS chambers resulted in reference depths z{sub ref} with deviations in the range of +/−0.45mm for all energies. Conclusion: The position accuracy of 0.2mm can be fulfilled with the TRUFIX system. The comparison of the 10 different ROOS ionization chambers showed noticeable deviations in the determined reference depth. The impact of a positioning uncertainty of about 0.3–0.4mm on the total perturbation correction will be considered.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Determination of the strong-coupling constant from the Z-boson transverse-momentum distribution

Abstract The strong-coupling constant is determined from the low-momentum region of the transverse-momentum distribution ofZbosons produced through the Drell–Yan process, using predictions at third order in perturbative QCD. The analysis employs a measurement performed in proton-antiproton collisions at a centre-of-mass energy of$$\sqrt{s} = 1.96$$ s = 1.96 TeV with the CDF experiment. The determined value of the strong coupling at the reference scale corresponding to theZ-boson mass is$$\alpha _S(m_Z)= 0.1191^{+0.0013}_{-0.0016}$$ α S ( m Z ) = 0 . 1191 - 0.0016 + 0.0013 .

Physics↗

Validation of transfer map calculation for electrostatic deflectors in the code COSY INFINITY

The code COSY INFINITY uses a beamline coordinate system with a Frenet–Serret frame relative to the reference particle, and calculates differential algebra-valued transfer maps by integrating the ODEs of motion in the respective vector space over a differential algebra (DA). In our work, we described and performed computation of the DA transfer map of an electrostatic spherical deflector in a laboratory coordinate system using two conventional methods: (1) by integrating the ODEs of motion using a numerical integrator and (2) by computing analytically and in closed form the properties of the respective elliptical orbits from Kepler theory. We compared the resulting transfer maps with (3) the DA transfer map of COSY INFINITY’s built-in electrostatic spherical deflector element ESP and (4) the transfer map of the electrostatic spherical deflector computed using the program GIOS, which uses analytic formulas from a paper1 by Hermann Wollnik regarding second-order aberrations. In addition to the electrostatic spherical deflector, we studied an electrostatic cylindrical deflector, where the Kepler theory is not applicable. We computed the DA transfer map by the ODE integration method (1), and we compared it with the transfer maps by (3) COSY INFINITY’s built-in electrostatic cylindrical deflector element ECL and (4) GIOS. The transfer maps of electrostatic spherical and cylindrical deflectors obtained using the direct calculation methods (1) and (2) are in excellent agreement with those computed using (3) COSY INFINITY. On the other hand, we found a significant discrepancy with (4) the program GIOS.

43 PARTICLE ACCELERATORS↗

OpenEIS Algorithms

The OpenEIS Algorithm package seeks to provide a low-risk path for building owners, service providers and managers to explore analytical methods for improving building control and operational efficiency. Users of this software can analyze building data, and learn how commercial implementations would provide long-term value. The code also serves as a reference implementation for developers who wish to adapt the algorithms for use in commercial tools or service offerings.

Granderon, Jessica↗

Performance of Convection-Permitting and Convection-Parameterized Models in Reproducing the Extreme Precipitation Intensity Relationship with Surface Conditions

Here, this study investigates the warm-season extreme precipitation–temperature scaling relationship in CONUS404, a convection-permitting (4 km) Weather Research and Forecasting (WRF) Model simulation over the conterminous United States for the past four decades, and compares it with the WRF-Thermodynamic Global Warming (WRF-TGW) historical simulation at a coarser resolution (12 km) using parameterized convection. We also analyze the NCEP stage IV and NASA Integrated Multi-satellitE Retrievals for the Global Precipitation Measurement (IMERG) datasets as observational benchmarks. We examine how extreme precipitation intensity (EPI) varies with temperature and saturation deficit over representative regions based on hourly data. The stage IV and IMERG data show a similar pattern of EPI variation with temperature and saturation deficit, except that the EPI peak is lower in IMERG than in stage IV. Under dry and hot conditions, EPI decreases too rapidly with elevated saturation deficit in both CONUS404 and WRF-TGW compared to observations, but the performance of CONUS404 is superior to WRF-TGW. When the near-surface atmosphere is saturated or close to saturated, both CONUS404 and WRF-TGW produce higher peak values of EPI relative to the observational references; IMERG exhibits scaling rates close to the Clausius–Clapeyron (C–C) relationship, while CONUS404, WRF-TGW, and stage IV all demonstrate super-C–C scaling behaviors. Despite marked warming over the past four decades, in both CONUS404 and WRF-TGW, the scaling relationship between EPI and temperature in a saturated atmosphere remains stable and robust. This indicates a strong potential for the EPI–temperature scaling rate under saturation to be used as an emergent constraint in reducing uncertainties of future extreme precipitation projection.

Atmosphere↗

Global scale environmental control of plant photosynthetic capacity

Photosynthetic capacity, determined by light harvesting and carboxylation reactions, is a key plant trait that determines the rate of photosynthesis; however, in Earth System Models (ESMs) at a reference temperature, it is either a fixed value for a given plant functional type or derived from a linear function of leaf nitrogen content. In this study, we conducted a comprehensive analysis that considered correlations of environmental factors with photosynthetic capacity as determined by maximum carboxylation (V c,m ) rate scaled to 25°C (i.e., V c,25; μmol CO 2 ·m –2 ·s –1 ) and maximum electron transport rate (Jmax) scaled to 25°C (i.e., J 25 ; μmol electron·m –2 ·s –1 ) at the global scale. Our results showed that the percentage of variation in observed Vc,25 and J25 explained jointly by the environmental factors (i.e., day length, radiation, temperature, and humidity) were 2–2.5 times and 6–9 times of that explained by area-based leaf nitrogen content, respectively. Environmental factors influenced photosynthetic capacity mainly through photosynthetic nitrogen use efficiency, rather than through leaf nitrogen content. The combination of leaf nitrogen content and environmental factors was able to explain ~56% and ~66% of the variation in V c,25 and J 25 at the global scale, respectively. As a result, our analyses suggest that model projections of plant photosynthetic capacity and hence land–atmosphere exchange under changing climatic conditions could be substantially improved if environmental factors are incorporated into algorithms used to parameterize photosynthetic capacity in ESMs.

54 ENVIRONMENTAL SCIENCES↗

Evaluation of Radiometers Deployed at the National Renewable Energy Laboratory's Solar Radiation Research Laboratory

This study analyzes the performance of various commercially available radiometers used for measuring global horizontal irradiances and direct normal irradiances. These include pyranometers, pyrheliometers, rotating shadowband radiometers, and a pyranometer with fixed internal shading and are all deployed at the National Renewable Energy Laboratory's Solar Radiation Research Laboratory. Data from 32 global horizontal irradiance and 19 direct normal irradiance radiometers are presented. The radiometers in this study were deployed for one year (from April 1, 2011, through March 31, 2012) and compared to measurements from radiometers with the lowest values of estimated measurement uncertainties for producing reference global horizontal irradiances and direct normal irradiances.

14 SOLAR ENERGY↗