Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Reads”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Quantum noise in the mirror-field system: A field theoretic approach

We revisit the quantum noise problem in the mirror-field system by a field-theoretic approach. Here a perfectly reflecting mirror is illuminated by a single-mode coherent state of the massless scalar field. The associated radiation pressure is described by a surface integral of the stress-tensor of the field. The read-out field is measured by a monopole detector, from which the effective distance between the detector and mirror can be obtained. In the slow-motion limit of the mirror, this field-theoretic approach allows to identify various sources of quantum noise that all in all leads to uncertainty of the read-out measurement. In addition to well-known sources from shot noise and radiation pressure fluctuations, a new source of noise is found from field fluctuations modified by the mirror's displacement. Correlation between different sources of noise can be established in the read-out measurement as the consequence of interference between the incident field and the field reflected off the mirror. In the case of negative correlation, we found that the uncertainty can be lowered than the value predicted by the standard quantum limit. Since the particle-number approach is often used in quantum optics, we compared results obtained by both approaches and examine its validity. We also derive a Langevin equation that describes the stochastic dynamics of the mirror. The underlying fluctuation-dissipation relation is briefly mentioned. Finally we discuss the backreaction induced by the radiation pressure. It will alter the mean displacement of the mirror, but we argue this backreaction can be ignored for a slowly moving mirror. - Highlights: Black-Right-Pointing-Pointer The quantum noise problem in the mirror-field system is re-visited by a field-theoretic approach. Black-Right-Pointing-Pointer Other than the shot noise and radiation pressure noise, we show there are new sources of noise and correlation between them. Black-Right-Pointing-Pointer The noise correlations can be used to suppress the overall quantum noise on the mirror. Black-Right-Pointing-Pointer The equation of motion of the mirror is derived and the backreaction of the radiation field is discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Universal properties of the FQH state from the topological entanglement entropy and disorder effects

The topological entanglement entropy (TEE) is a robust measurement of the quantum many-body state with topological order. In fractional quantum Hall (FQH) state, it has a connection to the quantum dimension of the state itself and its quasihole excitations from the conformal field theory (CFT) description. We study the entanglement entropy (EE) in the Moore–Read (MR) and Read–Rezayi (RR) FQH states. The non-Abelian quasihole excitation induces an extra correction of the TEE which is related to its quantum dimension. With considering the effects of the disorder, the ground state TEE is stable before the spectral gap closing and the level statistics seems to have significant change with a stronger disorder, which indicates a many-body localization (MBL) transition. - Highlights: • The TEE in Read–Rezayi FQH series are studied on cylinder in real space. • Ground state TEE is robust before gap closing in the presence of the disorder. • Strong disorder drives the system into a MBL phase.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Evaluation of Scatter Contribution and Distance Error by Iterative Methods for Strength Determination of HDR {sup 192}Ir Brachytherapy Source

High-dose rate (HDR) {sup 192}Ir brachytherapy sources are commonly used for management of malignancies by brachytherapy applications. Measurement of source strength at the hospital is an important dosimetry requirement. The use of 0.6-cm{sup 3} cylindrical ionization chamber is one of the methods of measuring the source strength at the hospitals because this chamber is readily available for beam calibration and dosimetry. While using the cylindrical chamber for this purpose, it is also required to determine the positioning error of the ionization chamber, with respect to the source, commonly called a distance error (c). The contribution of scatter radiation (M{sub s}) from floor, walls, ceiling, and other materials available in the treatment room also need to be determined accurately so that appropriate correction can be applied while calculating the source strength from the meter reading. Iterative methods of Newton-Raphson and least-squares were used in this work to determine scatter contribution in the experimentally observed meter reading (pC/s) of a cylindrical ionization chamber. Monte Carlo simulation was also used to cross verify the results of the least-squares method. The experimentally observed, least-squares calculated and Monte Carlo estimated values of meter readings from HDR {sup 192}Ir brachytherapy source were in good agreement. Considering procedural simplicity, the method of least-squares is recommended for use at the hospitals to estimate values of f (constant of proportionality), c, and M{sub s} required to determine the strength of HDR {sup 192}Ir brachytherapy sources.

07 ISOTOPE AND RADIATION SOURCES↗

Characterization of a silicon photo-multiplier array with summing board as a photo-multiplier tube replacement in organic scintillator assemblies

In this work, we report on the energy, timing, and pulse-shape discrimination performance of cylindrical 5.08 cm diameter x 5.08 cm thick and 7.62 cm diameter x 7.62 cm thick trans-stilbene crystals read out with the passively summed output of three different commercial silicon photo-multiplier arrays. Our results indicate that using the summed output of an 8 x 8 array of SiPMs provides performance competitive with photo-multiplier tubes for many neutron imaging and correlated particle measurements. For a 5.08 cm diameter x 5.08 cm thick crystal read out with SensL’s ArrayJ-60035_64P-PCB, which had the best overall properties, we measure the energy resolution as 17.8 ± 0.8% at 341 keVee (σ/E), the timing resolution in the 180–400 keVee range as 236 ± 61 ps (σ), and the pulse-shape discrimination figure-of-merit as 2.21 ± 0.03 in the 230–260 keVee energy range. For a 7.62 cm diameter x 7.62 cm thick crystal read out with SensL’s ArrayJ-60035_64P-PCB, we measure the energy resolution as 21.9 ± 2.3% at 341 keVee, the timing resolution in the 180–400 keVee range as 518 ± 42 ps, and the pulse-shape discrimination figure-of-merit as 1.49 ± 0.01 in the 230–260 keVee energy range. Our findings enable many scintillator-based instruments to enjoy the size, robustness, and power benefits of silicon photo-multiplier arrays as replacement for the photo-multiplier tubes that are predominantly used today.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Resistive AC-Coupled Silicon Detectors: principles of operation and first results from a combined analysis of beam test and laser data

This paper presents the principles of operation of Resistive AC-Coupled Silicon Detectors (RSDs) and measurements of the temporal and spatial resolutions using a combined analysis of laser and beam test data. RSDs are a new type of n-in-p silicon sensor based on the Low-Gain Avalanche Diode (LGAD) technology, where the n+ implant has been designed to be resistive, and the read-out is obtained via AC-coupling. The truly innovative feature of RSD is that the signal generated by an impinging particle is shared isotropically among multiple read-out pads without the need for floating electrodes or an external magnetic field. Careful tuning of the coupling oxide thickness and the n+ doping profile is at the basis of the successful functioning of this device. Several RSD matrices with different pad width-pitch geometries have been extensively tested with a laser setup in the Laboratory for Innovative Silicon Sensors in Torino, while a smaller set of devices have been tested at the Fermilab Test Beam Facility with a 120 GeV/c proton beam. The measured spatial resolution ranges between 2.5μm for 70–100 pad-pitch geometry and 17μm with 200–500 matrices, a factor of 10 better than what is achievable in binary read-out (bin size/12). Beam test data show a temporal resolution of ~40ps for 200 μm pitch devices, in line with the best performances of LGAD sensors at the same gain.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Author Correction: Energy use and life cycle greenhouse gas emissions of drones for commercial package delivery

In the original version of this Article, the first sentence of the sixth paragraph of the "Comparing emissions" section, the Results originally incorrectly read as 'In the base case, delivery of a small (0.5 kg) package with the small quadrotor drone has lower impacts than delivery by diesel truck, ranging from a 59% reduction in GHGs in California, to a 17% reduction in Missouri'. The correct version states '54%' instead of '59%' and '23%' instead of '17%'.The fourth sentence of the same paragraph originally incorrectly read as 'In the base case, delivery of a medium-sized (8 kg) package has 17% lower GHGs than delivery by truck in California, is about equivalent to delivery trucks for the U.S. average electricity mix, but has 77% higher GHGs than truck delivery in Missouri, which has a carbon-intensive electricity grid'. The correct version states 'In the base case, delivery of a medium-sized (8 kg) package has 9% lower GHGs than delivery by truck in California, is about 24% higher than delivery trucks for the U.S. average electricity mix, and has 50% higher GHGs than truck delivery in Missouri, which has a carbon-intensive electricity grid.The last sentence of the seventh paragraph of the same section originally incorrectly read as 'Because of the importance of electricity used to power the octocopter, charging with low-carbon electricity of 200 g GHG/kWh can reduce delivered package GHGs by 34% compared to diesel trucks'. The correct version states '37%' instead of '34%'.These errors have been corrected in both the PDF and HTML versions of the Article.

Stolaroff, Joshuah K.↗

Benchmarking second and third-generation sequencing platforms for microbial metagenomics

Shotgun metagenomic sequencing is a common approach for studying the taxonomic diversity and metabolic potential of complex microbial communities. Current methods primarily use second generation short read sequencing, yet advances in third generation long read technologies provide opportunities to overcome some of the limitations of short read sequencing. Here, we compared seven platforms, encompassing second generation sequencers (Illumina HiSeq 300, MGI DNBSEQ-G400 and DNBSEQ-T7, ThermoFisher Ion GeneStudio S5 and Ion Proton P1) and third generation sequencers (Oxford Nanopore Technologies MinION R9 and Pacific Biosciences Sequel II). We constructed three uneven synthetic microbial communities composed of up to 87 genomic microbial strains DNAs per mock, spanning 29 bacterial and archaeal phyla, and representing the most complex and diverse synthetic communities used for sequencing technology comparisons. Our results demonstrate that third generation sequencing have advantages over second generation platforms in analyzing complex microbial communities, but require careful sequencing library preparation for optimal quantitative metagenomic analysis. Our sequencing data also provides a valuable resource for testing and benchmarking bioinformatics software for metagenomics.

59 BASIC BIOLOGICAL SCIENCES↗

Sequence Data for Clostridium autoethanogenum using Three Generations of Sequencing Technologies

During the past decade, DNA sequencing output has been mostly dominated by the second generation sequencing platforms which are characterized by low cost, high throughput and shorter read lengths for example, Illumina. The emergence and development of so called third generation sequencing platforms such as PacBio has permitted exceptionally long reads (over 20 kb) to be generated. Due to read length increases, algorithm improvements and hybrid assembly approaches, the concept of one chromosome, one contig and automated finishing of microbial genomes is now a realistic and achievable task for many microbial laboratories. In this paper, we describe high quality sequence datasets which span three generations of sequencing technologies, containing six types of data from four NGS platforms and originating from a single microorganism, Clostridium autoethanogenum. The dataset reported here will be useful for the scientific community to evaluate upcoming NGS platforms, enabling comparison of existing and novel bioinformatics approaches and will encourage interest in the development of innovative experimental and computational methods for NGS data.

59 BASIC BIOLOGICAL SCIENCES↗

Concurrent data structures in the ATLAS offline software

In preparation for Run 3 of the LHC, the ATLAS experiment is modifying its offline software to be fully multithreaded. An important part of this is data structures that can be concurrently accessed from many threads both efficiently and safely. A standard way of achieving this is through mutual exclusion; however, the overhead from this can sometimes be excessive. Fully lockless implementations are known for some data structures; however, they are typically complex, and the overhead they require can sometimes be larger than that required for locking implementations. An interesting compromise is to allow lockless access only for reading but not for writing. This often allows the data structures to be much simpler, while still giving good performance for read-mostly access patterns. This proceeding shows some examples of this strategy in data structures used by the ATLAS offline software. It also gives examples of synchronization strategies inspired by read-copy-update, as well as helpers for memorizing values in a multithreaded environment.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Physics of Non-Inertial Reference Frames

Physics of non-inertial reference frames is a generalizing of Newton's laws to any reference frames. It is the system of general axioms for classical and quantum mechanics. The first, Kinematics Principle reads: the kinematic state of a body free of forces conserves and equal in absolute value to an invariant of the observer's reference frame. The second, Dynamics Principle extended Newton's second law to non-inertial reference frames and also contains additional variables there are higher derivatives of coordinates. Dynamics Principle reads: a force induces a change in the kinematic state of the body and is proportional to the rate of its change. It is mean that if the kinematic invariant of the reference frame is n-th derivative with respect the time, then the dynamics of a body being affected by the force F is described by the 2n-th differential equation. The third, Statics Principle reads: the sum of all forces acting a body at rest is equal to zero.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Investigation of the recombination mechanism of excess carriers in undoped BaSi{sub 2} films on silicon

Excess-carrier recombination mechanisms in undoped BaSi{sub 2} epitaxial films grown by molecular beam epitaxy on n-type silicon substrates have been studied by the microwave-detected photoconductivity decay measurement. The measured excess-carrier decay is multiexponential, and we divided it into three parts in terms of the decay rate. Measurement with various excitation laser intensities indicates that initial rapid decay is due to Auger recombination, while the second decay mode with approximately constant decay to Shockley-Read-Hall recombination. Slow decay of the third decay mode is attributed to the carrier trapping effect. To analyze Shockley-Read-Hall recombination, the formulae are developed to calculate the effective lifetime (time constant of decay) from average carrier concentration. The measurement on the films with the thickness of 50-600 nm shows that the decay due to Shockley-Read-Hall recombination is the slower in the thicker films, which is consistent with the formulae. By fitting the calculated effective lifetime to experimental ones, the recombination probability is extracted. The recombination probability is found to be positively correlated with the full width at half-maximum of the X-ray rocking curves, suggesting that dislocations are acting as recombination centers.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A new development on measurement and control software of SANS BATAN spectrometer (SMARTer) in Serpong, Indonesia

In 2005, the main computer for data acquisition and control system of Small-angle Neutron Scattering (SANS) BATAN Spectrometer (SMARTer) was replaced since it halted to operate the spectrometer. According to this replacement, the new software for data acquisition and control system has been developed in-house. Visual Basic programming language is used in developing the software. In the last two years, many developments have been made both in the hardware and also the software to conduct the experiment is more effective and efficient. Lately, the previous motor controller card (ISA Card) was replaced with the programmable motor controller card (PCI Card) for driving one motor of position sensitive detector (PSD), eight motors of four collimators, and six motors of six pinhole discs. This new control system software makes all motors can be moved simultaneously, then it reduces significantly the consuming time of setting up the instrument before running the experiment. Along with that development, the new data acquisition software under MS Windows operating system is also developed to drive a beam stopper in X-Y directions as well as to read the equipment status such as position of the collimators and PSD, to acquire neutron counts on monitor and PSD detectors, and also to manage 12 samples position automatically. A timer object which is set in one second to read the equipment status via serial port of the computer (RS232C), and general purpose interface board (GPIB) for reading the total counts of each pixel of the PSD from histogram memory was used in this new software. The experiment result displayed in real time on the main window, and the data is saved in the special format for further data reduction and analysis. The new software has been implemented and performed for experiment using a preset count or preset time mode for absolute scattering intensity method.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Recombination rate analysis in long minority carrier lifetime mid-wave infrared InGaAs/InAsSb superlattices

Gallium is incorporated into the strain-balanced In(Ga)As/InAsSb superlattice system to achieve the same mid-wave infrared cutoff tunability as conventional Ga-free InAs/InAsSb type-II superlattices, but with an additional degree of design freedom to enable optimization of absorption and transport properties. Time-resolved photoluminescence measurements of InGaAs/InAsSb superlattice characterization- and doped device structures are reported from 77 to 300 K and compared to InAs/InAsSb. The low-injection photoluminescence decay yields the minority carrier lifetime, which is analyzed with a recombination rate model, enabling the determination of the temperature-dependent Shockley–Read–Hall, radiative, and Auger recombination lifetimes and extraction of defect energy levels and capture cross section defect concentration products. The Shockley–Read–Hall-limited lifetime of undoped InGaAs/InAsSb is marginally reduced from 2.3 to 1.4 μs due to the inclusion of Ga; however, given that Ga improves the vertical hole mobility by a factor of >10×, a diffusion-limited InGaAs/InAsSb superlattice nBn could expect a lower bound of 2.5× improvement in diffusion length with significant impact on photodetector quantum efficiency and radiation hardness. At temperatures below 120 K, the doped device structures are Shockley–Read–Hall limited at 0.5 μs, which shows promise for detector applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nonvolatile memory cells from hafnium zirconium oxide ferroelectric tunnel junctions using Nb and NbN electrodes

Ferroelectric tunnel junctions (FTJs) utilizing hafnium zirconium oxide (HZO) have attracted interest as non-volatile memory for microelectronics due to ease of integration into back-end-of-line (BEOL) complementary metal oxide semiconductor fabrication. This work examines asymmetric electrode NbN/HZO/Nb devices with 7 nm thick HZO as FTJs in a memory structure, with an output resistance that can be controlled by read and write voltages. The individual FTJs are measured to have a tunneling electroresistance of 10 during the read state without significant filament conduction formation and reasonable ferroelectric performance. Endurance and remanent polarizations of up to 10 5 cycles and 20 μC/cm 2 , respectively, are measured and are shown to be dependent on the cycling voltage. Electrical measurements demonstrate how magnitude of the write pulse can modulate the high state resistance and the read pulse influences both resistance values as well as separation of resistance states. Then, by using two opposite switching FTJ devices in series, a programmable nonvolatile resistor divider is demonstrated. Measurements of these two FTJ unit memory cells show wide applicability to a BEOL microfabrication process for a re-readable, rewritable, and nonvolatile memory cell.

42 ENGINEERING↗

Multistate resistance in TaN/(Hf,Zr)O 2 /Ta ferroelectric tunnel junctions

Ferroelectric tunnel junctions (FTJs) utilizing hafnium zirconium oxide (HZO) have emerged as promising non-volatile memory elements for microelectronics, compatible with back end of line (BEOL) complementary–metal–oxide semiconductor fabrication. This study investigates asymmetric electrode TaN/HZO/Ta devices with a 6 nm thick HZO layer as FTJs for multistate resistive memory applications. The individual FTJs exhibit a resistance ratio exceeding 10× when utilized as a binary state device, with pulsing between −1.7 and +1.4 V to set the high resistance state (HRS) and low resistance state (LRS), respectively. Following with reduced write voltage pulses allows the ferroelectric device to operate with a selection of over 32 distinct resistance states (2 5 bits) between the LRS and HRS. This work then explores the stability of the resistance states during write/read pulse cycling, along with the stability of the state after multiple read pulses. Accessing the multibit state shows stability within 50 reads with the binary state remaining stable for more than 4000 reads pulses. With their multistate tunability and versatility, FTJs hold promise as BEOL memory elements for compute-in-memory (CiM) arrays, binary digital memory, or weighted vector matrix multiplication applications with low power consumption during computations.

CMOS↗

Spontaneous ribosomal translocation of mRNA and tRNAs into a chimeric hybrid state

The elongation factor G (EF-G)–catalyzed translocation of mRNA and tRNA through the ribosome is essential for vacating the ribosomal A site for the next incoming aminoacyl-tRNA, while precisely maintaining the translational reading frame. Here, the 3.2-Å crystal structure of a ribosome translocation intermediate complex containing mRNA and two tRNAs, formed in the absence of EF-G or GTP, provides insight into the respective roles of EF-G and the ribosome in translocation. Unexpectedly, the head domain of the 30S subunit is rotated by 21°, creating a ribosomal conformation closely resembling the two-tRNA chimeric hybrid state that was previously observed only in the presence of bound EF-G. The two tRNAs have moved spontaneously from their A/A and P/P binding states into ap/P and pe/E states, in which their anticodon loops are bound between the 30S body domain and its rotated head domain, while their acceptor ends have moved fully into the 50S P and E sites, respectively. Remarkably, the A-site tRNA translocates fully into the classical P-site position. Furthermore, although the mRNA also undergoes movement, codon–anticodon interaction is disrupted in the absence of EF-G, resulting in slippage of the translational reading frame. We conclude that, although movement of both tRNAs and mRNA (along with rotation of the 30S head domain) can occur in the absence of EF-G and GTP, EF-G is essential for enforcing coupled movement of the tRNAs and their mRNA codons to maintain the reading frame.

59 BASIC BIOLOGICAL SCIENCES↗

Optimizing Charge-coupled Device Readout Enabled by the Floating-gate Amplifier

Multiple-Amplifier Sensing (MAS) charge-coupled devices (CCDs) have recently been shown to be promising silicon detectors that meet noise sensitivity requirements for next generation Stage-5 spectroscopic surveys and potentially, future space-based imaging of extremely faint objects on missions such as the Habitable Worlds Observatory. Building upon the capability of the Skipper CCD to achieve deeply sub-electron noise floors, MAS CCDs utilize multiple floating-gate amplifiers along the serial register to increase the readout speed by a factor of the number of output nodes compared to a Skipper CCD. We introduce and experimentally demonstrate on a 16-channel prototype device new readout techniques that exploit the MAS CCD’s floating-gate amplifiers to optimize the correlated double sampling by resetting once per line instead of once per pixel. With this new mode, we find an optimal filter to subtract the noise from the signal during read out. We also take advantage of the MAS CCD’s structure to tune the read time by independently changing integration times for the signal and reference level. Together with optimal weighted averaging of the 16 outputs, these approaches enable us to reach a sub-electron noise of 0.9 e − rms pix −1 at 19 μs pix −1 for a single charge measurement per pixel—simultaneously giving a 30% faster readout time and 10% lower read noise compared to performance previously evaluated without these techniques.

Lin, Kenneth W. (ORCID:0000000189672281)↗

A variant selection framework for genome graphs

Abstract Motivation Variation graph representations are projected to either replace or supplement conventional single genome references due to their ability to capture population genetic diversity and reduce reference bias. Vast catalogues of genetic variants for many species now exist, and it is natural to ask which among these are crucial to circumvent reference bias during read mapping. Results In this work, we propose a novel mathematical framework for variant selection, by casting it in terms of minimizing variation graph size subject to preserving paths of length α with at most δ differences. This framework leads to a rich set of problems based on the types of variants [e.g. single nucleotide polymorphisms (SNPs), indels or structural variants (SVs)], and whether the goal is to minimize the number of positions at which variants are listed or to minimize the total number of variants listed. We classify the computational complexity of these problems and provide efficient algorithms along with their software implementation when feasible. We empirically evaluate the magnitude of graph reduction achieved in human chromosome variation graphs using multiple α and δ parameter values corresponding to short and long-read resequencing characteristics. When our algorithm is run with parameter settings amenable to long-read mapping (α = 10 kbp, δ = 1000), 99.99% SNPs and 73% SVs can be safely excluded from human chromosome 1 variation graph. The graph size reduction can benefit downstream pan-genome analysis. Availability and implementation https://github.com/AT-CG/VF. Supplementary information Supplementary data are available at Bioinformatics online.

59 BASIC BIOLOGICAL SCIENCES↗