Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Rate of change of frequencies”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Technology evaluation of man-rated acceleration test equipment for vestibular research

The considerations for eliminating acceleration noise cues in horizontal, linear, cyclic-motion sleds intended for both ground and shuttle-flight applications are addressed. the principal concerns are the acceleration transients associated with change in direction-of-motion for the carriage. The study presents a design limit for acceleration cues or transients based upon published measurements for thresholds of human perception to linear cyclic motion. The sources and levels for motion transients are presented based upon measurements obtained from existing sled systems. The approaches to a noise-free system recommends the use of air bearings for the carriage support and moving-coil linear induction motors operating at low frequency as the drive system. Metal belts running on air bearing pulleys provide an alternate approach to the driving system. The appendix presents a discussion of alternate testing techniques intended to provide preliminary type data by means of pendulums, linear motion devices and commercial air bearing tables.

Taback, I.↗

Integrated Optimization and Control of a Hybrid Gas Turbine/sCO 2 Power System

During phase-I, the project team led by Echogen Power Systems (EPS) had two primary objectives based on investigating the application of gas turbines with supercritical carbon dioxide (sCO 2 ) power cycles. The first objective was to improve the overall efficiency and performance of a hybrid gas turbine/sCO 2 power system through a joint optimization of the two subsystems (gas turbine and sCO 2 power cycle) using non-linear optimization techniques that simultaneously evaluate thermal performance of the combined cycle. The hybrid power system included several points of interaction, including (but not limited to) gas turbine exhaust, fuel heating, inlet chilling and turbine cooling. The second objective was to establish a baseline transient response model of the hybrid power system and a notional microgrid and begin steps to integrate the control systems of the three major elements (gas turbine, sCO 2 cycle and grid controller). The project team established a baseline performance for a combined cycle power plant using a production gas turbine and scaled sCO 2 power cycle only utilizing exhaust heat recovery. Echogen’s non-linear techno-economic optimization code was extended by adding gas turbine component models derived from a in-house developed gas turbine design code. With the two cycles coupled by the gas turbine exhaust, design parameters of both cycles were allowed to vary simultaneously to determine performance opportunity versus isolated designs. Returning to the baseline gas turbine/sCO 2 power cycle transient models: Echogen had in-house developed sCO 2 cycle transient model in GT-Suite system simulation software, and had partnered with Siemens Finspång for gas turbine transient model, and Siemens PTI group to provide micro-grid load profile as well as hybrid power cycle generated load (power and frequency) analysis. The transient model for the SGT-750 Siemens gas turbine was a “black-box” functional mock-up interface (FMI) model developed by Siemens Industrial Turbomachinery in Finspång, Sweden. The SGT-750 is a twin-shaft gas turbine that produces 40 MW electricity with an efficiency of about 40% at ISO conditions. At 100% gas turbine throttle (load), the SGT-750 has average exhaust conditions of 114.6 kg/s and 469.8°C. The transient model for sCO 2 power cycle was developed by Echogen in GT-SUITE 1D system simulation software platform. The basic CO 2 flow circuit has single-shaft turbomachinery with net 11.5 MW electrical power output at design conditions. The power turbine has a double-ended shaft with one end connected to synchronous generator through a fixed-ratio gearbox. The other end of power turbine is connected to the compressor through a continuously variable transmission. The major components of the sCO 2 power cycle modeled include air cooled condenser/cooler, CO 2 compressor, recuperator, two waste heat exchanger coils, power turbine, continuous variable transmission, gearbox and generator. Integration of SGT-750 transient model and sCO 2 power cycle transient model was done in Matlab Simulink. In the integrated model, the gas turbine and sCO 2 power cycle interacted at two points, first one being the gas turbine exhaust gas flow rate and temperature, which were inputs to sCO 2 power cycle model. The second point was the distribution of micro-grid load demand signal between the SGT-750 generator and sCO 2 cycle generator. For a given combined-cycle load demand, the gas turbine load demand was equal to the total demand minus the sCO 2 cycle power generated. In the present study the integrated model was simulated for two cases of grid load demand: (i) for a step change, both positive-step and negative-step, in grid load demand (ii) for a micro-grid load demand curve provided by Siemens PTI group. Finally, the time series plots representing load demand versus integrated system response were presented including the sCO 2 power cycle control system performance plots. The actual generated power and frequency of both the generators, gas turbine and sCO 2 power cycle, was supplied to Siemens PTI group for dynamic grid assessment, results of which are provided in appendices.

03 NATURAL GAS↗

Laboratory demonstration of the prediction of wind-blown turbulence by adaptive optics at 8 kHz with use of LQG control

The low-latency adaptive optical mirror system (LLAMAS) is designed to push the limits on achievable latencies and frame rates. It has 21 subapertures across its pupil. Here, a reformulated version of the linear quadratic Gaussian (LQG) method predictive Fourier control is implemented in LLAMAS; for all modes, it takes just 30 µs to compute. In the testbed, a turbulator mixes hot and ambient air to produce wind-blown turbulence. Wind prediction clearly improves correction when compared to an integral controller. Closed-loop telemetry shows that wind-predictive LQG removes the characteristic “butterfly” and reduces temporal error power by up to a factor of three for mid-spatial frequency modes. Strehl changes seen in focal plane images are consistent with telemetry and the system error budget.

47 OTHER INSTRUMENTATION↗

Equivalence Ratio Scans in a Rotating Detonation Engine

Published data for run times exceeding a few seconds in rotating detonation engines (RDEs) is rare, but long duration tests are necessary to understand both transient and persistent phenomena in RDE operation. Previous work has noted different detonation wave modes at different equivalence ratios. In the current study, multiple long-duration runs with constant air flow rate and variable equivalence ratio are conducted in a hydrogen-fueled, water-cooled RDE. Analysis of the capillary tube averaged pressure (CTAP) data reveals a strong correlation with equivalence ratio as well as a small time dependency due to transient thermal processes. Ion probe measurements are used to analyze detonation wave frequencies and modes, both of which are strongly dependent on the equivalence ratio. Mode transitions are observed to occur consistently as the equivalence ratio is traversed between 0.55 and 0.60. These transitions are also found to be a function of the direction of changing equivalence ratio (ascending or descending) and time.

Boyette, Wesley R.↗

Equivalence Ratio Scans in a Rotating Detonation Engine

Published data for run times exceeding a few seconds in rotating detonation engines (RDEs) is rare, but long duration tests are necessary to understand both transient and persistent phenomena in RDE operation. Previous work has noted different detonation wave modes at different equivalence ratios. In the current study, multiple long-duration runs with constant air flow rate and variable equivalence ratio are conducted in a hydrogen-fueled, water-cooled RDE. Analysis of the capillary tube averaged pressure (CTAP) data reveals a strong correlation with equivalence ratio as well as a small time dependency due to transient thermal processes. Ion probe measurements are used to analyze detonation wave frequencies and modes, both of which are strongly dependent on the equivalence ratio. Mode transitions are observed to occur consistently as the equivalence ratio is traversed between 0.55 and 0.60. These transitions are also found to be a function of the direction of changing equivalence ratio (ascending or descending) and time.

Boyette, Wesley R.↗

Risk of Impaired Performance Due to Reduced Muscle Mass, Strength &, Endurance (Short Title: Muscle) and Risk of Reduced Physical Performance Capabilities Due to Reduced Aerobic Capacity (Short Title: Aerobic)

This report reviews the scientific literature regarding the human system risks to the microgravity environment of space flight in relation to human performance. The primary human performance-related risks involve deconditioning of the cardiovascular and skeletal muscles systems due to prolonged exposure to the reduced gravitational input. The chronological history of U.S. space flight is reviewed as a starting point to inform and understand the gaps in the knowledge to these risks. Maintenance of physical performance capabilities involves understanding the health of many organ systems (peripheral [vascular, heart, blood volume, skeletal muscle] and central [brain]) that ultimately contribute to the submaximal and maximal capacity of the aerobic (VO2peak), skeletal muscle (strength and endurance) systems. Maintaining astronaut VO2peak, muscle mass, strength, and endurance before, during, and after space flight is a significant priority to NASA for the current International Space Station (ISS) era, as well as for future exploration missions. A growing research database from both space flight and ground-based analog studies finds that the cardiorespiratory system is compromised and skeletal muscles (predominantly postural muscles of the lower limbs) undergo atrophy. These structural and metabolic responses to living in microgravity conditions contribute to physiological deconditioning during space flight that potentially increase the risks to astronauts returning to surface operations (i.e., Moon, Mars, or Earth). The time course changes from short to long-duration space flight and the relationships between in-flight performance deconditioning levels are not well characterized. Moreover, there are large interindividual variabilities that may be dependent on genetics, age, sex, preflight fitness levels, and individual exercise prescriptions that need further careful evaluations. Efforts should be made to understand the current status of preflight, in-flight, and postflight exercise performance capability and to define the operational goals and target areas for protection with the in-flight exercise program. There is a bi-directional relationship between exercise prescription and hardware countermeasures that need further understanding in-flight. For example, hardware with limited capabilities/modalities may be counterbalanced by changes in exercise prescription (i.e., frequency, time, intensity, volume) for providing effective responses to maintain fitness. Importantly, the minimal requirements for exercise prescription on ISS hardware may not translate to lower capability hardware on exploration missions. Due to limited volume on exploration vehicles, future Artemis missions to the Lunar surface will not have similar exercise hardware capabilities as ISS. This may alter the effectiveness of hardware to provide adequate physiological stress on bodily systems allowing for adaptations to maintain aerobic capacity, strength, and bone density. Thus, it will be important to understand the exercise responses of current ISS countermeasures to develop individualized exercise prescriptions that minimize aerobic and muscular risks, accounting for the large variability of responses among crewmembers. Newer exploration exercise hardware is currently being evaluated that is more compact (i.e., E4D and Orion Flywheel) and will require careful evaluation of the hardware on the stressor (i.e., metabolic rate, oxygen uptake, and heart rate work relationships, and force plate load profiles) needed the human body to protect and maintain crew health and performance. Moreover, exercise responses on the hardware need careful evaluation on the chronic adaptations. Lastly, in-flight evaluation of hardware exercise response may differ in 0-g or partial-g compared to 1-g. Therefore, it cannot be assumed that the stress on the body will be the same in each environment. Understanding this has a direct impact on exercise prescriptions. This document provides an overview of key scientific investigations that have been conducted before, during, and after human space flight missions, as well as from human ground-based analog studies that contribute to the evidence base on changes in aerobic capacity and muscle mass, strength, and endurance. Additional data from rodent and nonhuman primate experiments of skeletal muscle unloading completed during space flight or ground-based flight-simulations provide supportive information about this risk topic. Most importantly, a recent, large dataset from long-duration ISS crew has been added to give improved insight into the variability of exercise response of crew, demonstrating that a large portion of the crew population return to Earth with greater than 10-20% loss of aerobic capacity and muscle strength and endurance. Data from human space flight and ground-based studies are narrowing in on the required exercise paradigms but thus far still provide an incomplete answer to an effective approach for maintaining skeletal muscle function and aerobic fitness of all human space travelers. Finally, the relationship of this risk topic to various space flight operational scenarios is examined and discussed.

Eric Rivas↗

Fast Relaxation on Qutrit Transitions of Nitrogen-Vacancy Centers in Nanodiamonds

Thanks to their versatility, nitrogen-vacancy (N-𝑉) centers in nanodiamonds have been widely adopted as nanoscale sensors. However, their sensitivities are limited by their short coherence times relative to N-𝑉⁢s in bulk diamond. A more complete understanding of the origins of decoherence in nanodiamonds is critical to improving their performance. Here we present measurements of fast spin relaxation on qutrit transitions between the energy eigenstates composed of the 𝑚 𝑠 =|±1⟩ states of the N-𝑉 − electronic ground state in approximately 40-nm nanodiamonds under ambient conditions. For frequency splittings between these states of 20 MHz or less the maximum theoretically achievable coherence time of the N-𝑉 spin is approximately 2 orders of magnitude shorter than would be expected if the N-𝑉 spin is treated as a qubit. We attribute this fast relaxation to electric field noise. We observe a strong falloff of the qutrit relaxation rate with the splitting between the states, suggesting that, whenever possible, measurements with N-𝑉⁢s in nanodiamonds should be performed at moderate axial magnetic fields (>60 G). We also observe that the qutrit relaxation rate changes with time. As a result, these findings indicate that surface electric field noise is a major source of decoherence for N-𝑉⁢s in nanodiamonds.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Rubidium atomic frequency standards for GPS Block IIR

The Rubidium Atomic Frequency Standards (RAFS) were provided for the GPS Block IIR NAVSTAR satellites. These satellites will replenish and upgrade the space segment of the Global Positioning System in the mid 1990s. The GPS RAFS Rb clocks are the latest generation of the high-performance rubidium frequency standards. They offer an aging rate in the low pp 10(exp 14)/day range and a drift-corrected 1-day stability in the low pp 10(exp 14) range. The Block IIR version of these devices will have improved performance, higher reliability, smaller size, and greater radiation hardness. The GPS Block IIR atomic clocks have a natural frequency configuration whereby they output a frequency of about 13.4 MHz that is a submultiple of the atomic resonance of Rb (or Cs). The RAFS operates at a low, fixed C-field for increased stability. The GPS Block IIR RAFS design, including the changes and improvements made, and the test results obtained are described.

Riley, William J.↗

Long-Term Impacts of Selective Logging on Amazon Forest Dynamics from Multi-Temporal Airborne LiDAR

Forest degradation is common in tropical landscapes, but estimates of the extent and duration of degradation impacts are highly uncertain. In particular, selective logging is a form of forest degradation that alters canopy structure and function, with persistent ecological impacts following forest harvest. In this study, we employed airborne laser scanning in 2012 and 2014 to estimate three-dimensional changes in the forest canopy and understory structure and aboveground biomass following reduced-impact selective logging in a site in Eastern Amazon. Also, we developed a binary classification model to distinguish intact versus logged forests. We found that canopy gap frequency was significantly higher in logged versus intact forests even after 8 years (the time span of our study). In contrast, the understory of logged areas could not be distinguished from the understory of intact forests after 6–7 years of logging activities. Measuring new gap formation between LiDAR acquisitions in 2012 and 2014, we showed rates 2 to 7 times higher in logged areas compared to intact forests. New gaps were spatially clumped with 76 to 89% of new gaps within 5 m of prior logging damage. The biomass dynamics in areas logged between the two LiDAR acquisitions was clearly detected with an average estimated loss of -4.14 +/- 0.76 MgC/hay. In areas recovering from logging prior to the first acquisition, we estimated biomass gains close to zero. Together, our findings unravel the magnitude and duration of delayed impacts of selective logging in forest structural attributes, confirm the high potential of airborne LiDAR multitemporal data to characterize forest degradation in the tropics, and present a novel approach to forest classification using LiDAR data.

Pinage, Ekena Rangel↗

Effect of anisotropic fast ions on internal kink stability in DIII-D negative and positive triangularity plasmas

Recent DIII-D experiments show that sawtooth stability is strongly affected by anisotropic fast ions from neutral beam injection (NBI) in both negative and positive triangularity plasmas. Fast ions from co-current NBI are stabilizing for the sawtooth stability, resulting in longer sawtooth periods. On the other hand, fast ions from counter-current NBI are destabilizing, leading to small and frequent sawteeth. The relative change of sawtooth period and amplitude is more than a factor of two. These observations appear to hold in both plasma shapes. Non-perturbative toroidal modeling, utilizing the magnetohydrodynamic-kinetic hybrid stability code MARS-K (Liu et al 2008 Phys. Plasmas 15 112503), reveals an asymmetric dependence of the stability of the n = 1 (n is the toroidal mode number) internal kink mode on the injection direction of NBI, being qualitatively consistent with the experimentally observed sawtooth behavior. The MARS-K modeling results suggest that anisotropic fast ions affect the mode growth rate and frequency through both adiabatic and non-adiabatic contributions. Here, the asymmetry of the internal kink mode instability relative to the NBI direction is mainly due to the non-adiabatic contribution of passing fast ions, which stabilize (destabilize) the internal kink with the co-(counter-) current NBI as compared to the fluid counterpart. However, finite orbit width (FOW) correction to passing particles partially cancels the asymmetry. Trapped particles are always stabilizing due to precessional drift resonance. Modeling also shows that fast ions affect the internal kink in a similar manner in both negative and positive triangularity plasmas, although being slightly more unstable in the negative triangularity configuration already in the fluid limit. The similarity is mainly attributed to the fact that the mode is localized in the plasma core region, with very similar eigenmode structures in both negative and positive configurations. Furthermore, MARS-K modeling indicates that other factors, such as the plasma rotation and the drift kinetic effects of thermal plasmas, weakly modify the mode stability as compared to the drift kinetic resonance effects and FOW correction of fast ions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

AFM Microcantilever With a Collocated AlN Sensor-Actuator Pair: Enabling Efficient Q-Control for Dynamic Imaging

This manuscript presents a novel microcantilever with an embedded piezoelectric sensor-actuator pair for dynamic atomic force microscopy (AFM). The transducer pair is constructed from a two-layered AlN stack. Stacking the piezoelectric transducers in this manner leads to a minimal feedthrough from actuation to sense electrode, granting a high dynamic range frequency response for dynamic mode AFM. The cantilever's design allows for dual mode operation at 1 st and 2 nd resonance modes. High resolution tapping mode imaging results are reported, while the cantilever is operated at these modes. A feedback control loop is used to modify quality factor of the 1 st mode of the cantilever, using a positive position feedback (PPF) controller. Here, a faster response time is achieved by reducing the Q-factor, enabling the cantilever to track the topography at a higher scan rate. Results of bimodal AFM imaging are reported, using amplitude changes of the 1 st mode for surface topography, while material properties are encoded in phase changes of the 2 nd mode.

47 OTHER INSTRUMENTATION↗

Millimeter-wave electromagnetic monitoring for liquid metal droplet-on-demand printing

As new printing approaches emerge, in situ diagnostics to monitor the print quality in real-time become essential for long-term monitoring and feedback control. In this article, we present a millimeter-wave electromagnetic monitoring approach for liquid metal droplet-on-demand printing to support the high-speed and real-time evaluation of droplet ejection. An open-ended rectangular waveguide is placed perpendicular to a jetted droplet stream and operated at a continuous-wave frequency of 40 GHz. Liquid metal droplets with diameters as low as 1.2 mm are characterized, and droplet jetting events on the order of 500 μm are detected at ejection rates up to 80 Hz. The measured results demonstrate that trends at the macro-level (large-scale print variation and anomalies at the nozzle tip) as well as micro-level (droplet size, position, and dynamics) can be detected using this technique.

42 ENGINEERING↗

Hemodynamic and autonomic nervous system responses to mixed meal ingestion in healthy young and old subjects and dysautonomic patients with postprandial hypotension

BACKGROUND. Although postprandial hypotension is a common cause of falls and syncope in elderly persons and in patients with autonomic insufficiency, the pathophysiology of this disorder remains unknown. METHODS AND RESULTS. We examined the hemodynamic, splanchnic blood pool, plasma norepinephrine (NE), and heart rate (HR) power spectra responses to a standardized 400-kcal mixed meal in 11 healthy young (age, 26 +/- 5 years) and nine healthy elderly (age, 80 +/- 5 years) subjects and 10 dysautonomic patients with symptomatic postprandial hypotension (age, 65 +/- 16 years). Cardiac and splanchnic blood pools were determined noninvasively by radionuclide scans, and forearm vascular resistance was determined using venous occlusion plethysmography. In healthy young and old subjects, splanchnic blood volume increased, but supine blood pressure remained unchanged after the meal. In both groups, HR increased and systemic vascular resistance remained stable. Forearm vascular resistance and cardiac index increased after the meal in elderly subjects, whereas these responses were highly variable and of smaller magnitude in the young. Young subjects demonstrated postprandial increases in low-frequency HR spectral power, representing cardiac sympatho-excitation, but plasma NE remained unchanged. In elderly subjects, plasma NE increased after the meal but without changes in the HR power spectrum. Patients with dysautonomia had a large postprandial decline in blood pressure associated with no change in forearm vascular resistance, a fall in systemic vascular resistance, and reduction in left ventricular end diastolic volume index. HR increased in these patients but without changes in plasma NE or the HR power spectrum. CONCLUSIONS. 1) In healthy elderly subjects, the maintenance of blood pressure homeostasis after food ingestion is associated with an increase in HR, forearm vascular resistance, cardiac index, and plasma NE. In both young and old, systemic vascular resistance is maintained. 2) Dysautonomic patients with postprandial hypotension fail to maintain systemic vascular resistance after a meal. This impairment in vascular response to meal ingestion may underlie the development of postprandial hypotension. 3) The measurement of mean HR or plasma NE does not adequately characterize autonomic cardiac control. Power spectral analysis suggests an impairment in the postprandial autonomic modulation of HR in healthy elderly and dysautonomic subjects, possibly predisposing to hypotension when vascular compensation is inadequate.

Non-NASA Center↗

Temporal Fluctuations in a 100-A LaB6 Hollow Cathode

The temporal fluctuations in the near plume of a 100-Amperes LaB6 (Lanthanum hexaboride) hollow cathode are experimentally investigated. At high currents, turbulent oscillations may contribute to two of the anomalous processes of hollow cathode operation - anomalous resistivity and the production of energetic ions. A detailed study of the properties of the oscillations in a high current cathode is necessary to determine the impact of the fluctuation spectrum on these two effects. In this investigation, a probe array is employed to measure the amplitude and dispersion of axial modes in the plume while a retarding potential analyzer yields estimates of the radial ion energy distribution. The onset of the ion acoustic turbulence (IAT) is observed at high current values, and the character of the turbulent spectrum is shown to agree with weak turbulent theory: the amplitude of the spectrum decreases with flow rate but increases with discharge current. Estimates of the anomalous collision frequency based on experimental observations indicate that the IAT collision frequency can exceed the classical collision frequency at sufficiently high discharge current densities. Additionally, the onset of the IAT is shown to be correlated with the appearance of a high energy ion tail and that the energy in this tail is comparable to the energy in the experimentally-observed IAT.

production of ions↗

Simultaneous measurements of velocity, temperature, and pressure using rapid CW wavelength-modulation laser-induced fluorescence of OH

The beam from a rapid-tuning single-frequency laser was used to probe the R1(7) and R1(11) A2Sigma(+) - X2Pi(0,0) line pair of OH at a 45-deg incident angle in a combustion-driven, supersonic free jet. Absorption line shapes were recorded in spatially resolved, single-point fluorescence. The Doppler shift, intensity ratio, and collisional broadening of the measured line pair were used to determine velocity, temperature, and pressure. The repetition rate of the measurement was 3 kHz.

Chang, A. Y.↗

The effect of temperature on attenuation-correction schemes in rain using polarization propagation differential phase shift

The study elucidates and quantifies differences in the response of the rate of change of polarization propagation differential phase shift Phi, the rate of attenuation for a horizontally/vertically polarized wave A(H,V), and the rate of polarization differential attenuation A(H-V) to temperature. It is shown that if the effects of temperature when estimating A(H) and A(H-V) from Phi are neglected, the average fractional standard error increases only slightly at 9 GHz but significantly at 5 and 3 GHz. Errors at 5 and 3 GHz are about two to three times those at 9 GHz. The performance of Phi-based schemes of attenuation correction at these lower frequencies is much more significantly degraded by temperature uncertainty than at 9 GHz. It is concluded that it is best to use Phi to correct for attenuation at the least-attenuating frequencies.

Jameson, A. R.↗

Autonomously Calibrating a Quadrupole Mass Spectrometer

A computer program autonomously manages the calibration of a quadrupole ion mass spectrometer intended for use in monitoring concentrations and changes in concentrations of organic chemicals in the cabin air of the International Space Station. The instrument parameters calibrated include the voltage on a channel electron multiplier, a discriminator threshold, and an ionizer current. Calibration is achieved by analyzing the mass spectrum obtained while sweeping the parameter ranges in a heuristic procedure, developed by mass spectrometer experts, that involves detection of changes in signal trends that humans can easily recognize but cannot necessarily be straightforwardly codified in an algorithm. The procedure includes calculation of signal-to-noise ratios, signal-increase rates, and background-noise-increase rates; finding signal peaks; and identifying peak patterns. The software provides for several recovery-from-error scenarios and error-handling schemes. The software detects trace amounts of contaminant gases in the mass spectrometer and notifies associated command- and-data-handling software to schedule a cleaning. Furthermore, the software autonomously analyzes the mass spectrum to determine whether the parameters of a radio-frequency ramp waveform are set properly so that the peaks of the mass spectrum are at expected locations.

Lee, Seungwon↗

Optical Time Transfer for Bistatic SAR Spacecraft

A spacecraft-to-spacecraft optical time-transfer simulation has been developed as a tool for informing NASA’s Surface Deformation and Change (SDC) mission architecture. The SDC mission will combine radar images from multiple spacecraft to improve understanding of the Earth’s sea-level and landscape changes. Spacecraft must be precisely synchronized in order to create sharp radar images. Simulation of multiple spacecraft time-synchronizing via laser communication can inform technology choices of a mission by providing a picosecond-precision level estimate of clock error. This timing and ranging simulation has been combined with a radar system performance analysis pipeline. The simulated timing errors are used to predict performance of bistatic SAR systems in the presence of oscillator noise and time synchronization in accuracy. This analysis includes both analytic approximation equations from existing literature, and a numerical radar simulation to extract key system performance parameters like phase error and signal-to-noise ratio (SNR)degradation. Precision time-transfer techniques facilitate the accurate synchronization of clocks between any combination of terminals. Most time-transfer technology for comparing two clocks at different terminals use radio frequencies (RF) to measure the time delay between the sending and receiving of signals. Laser technology offers the capability to transmit high data rates with systems that are of smaller size and lower power than comparable RF systems. The clocks on independent spacecraft will have some phase and frequency errors between them that result in clock drift. The two clock models that are included in this bi-directional MATLAB simulation are a cesium-based Chip-Scale Atomic Clock (CSAC) and a rubidium-based Miniature Atomic Clock (MAC). The CSAC has flown as hardware for small satellite missions such as the University of Florida’s CHOMPTT mission. A study of example orbits, including that of NASA NASA-ISRO Synthetic Aperture Radar Mission (NISAR) mission, and lasing rates demonstrate the impact of flight configuration parameters on the synchronization error between two spacecraft. The MATLAB timing simulation uses a Runge-Kutta 4th-order method to propagate spacecraft orbits and computes the light-travel time estimate between them. The simulation outputs the estimated range and estimated clock error based on a user-defined spacecraft cluster configuration. The radar simulation and analytic approximations are applied to evaluate a potential future NASA bistatic SAR constellation architecture. In the proposed architecture, satellites follow each other in the same orbit at 800 km altitude, with a 210 km baseline. We also baseline the CSAC as an ultra stable oscillator, and use NASA’s NISAR for baseline radar system parameters to compute a clock-system introduced phase error of 5.6 degrees without synchronization by frequent time transfer. We build on this base case with a sensitivity analysis of radar performance over a proposed range of constellation and radar system parameters. With this analysis pipeline, we comment on which radar parameters should or should not be changed to minimize synchronization requirements. This analysis technique could be extended or modified to evaluate the timing requirements of other geometries for other future multistatic SAR missions, or other interferometric satellite missions.

Surface Deformation and Change↗