Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Raman Spectroscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Free-standing gold elliptical nanoantenna with tunable wavelength in near-infrared region for enhanced Raman spectroscopy

The purpose of this work is to present a surface-enhanced Raman scattering (SERS) amplifying antenna for the possible usage in the near-infrared region. Instead of the visible-light range amplifying antenna such as a bowtie, the finite-difference time-domain (FDTD) simulation results indicate that elliptical antenna could provide large electromagnetic field enhancement at near-infrared wavelength by combining the free-standing enhancement property with large aspect ratios of the ellipse geometry. The simulation results consist with the enhancement factors characterized by SERS measurements at the excited wavelength of 785 nm for different aspect ratios and periodicities. In addition to the redshift of the resonance wavelength as the aspect ratio of ellipse increases, the free-standing structure modifies the resonance behavior and the dielectric environment of antenna by elevating the elliptical disk from the substrate. To interpret the simulation results, the analytical solution of resonance wavelength for ellipsoid dimmer is derived based on Lorentz–Mie theory, and comparisons are made between the analytical solution and simulation results. The quasi-static analytical solution provides a way to characterize the resonance behavior of two ellipsoid particles as a function of the gap distance, aspect ratio, and dielectric environment. In conclusion, the electrodynamic analysis for the periodic structure was performed in our FDTD simulations.

47 OTHER INSTRUMENTATION↗

Three-beam rotational coherent anti-Stokes Raman spectroscopy thermometry in scattering environments

Three-beam rotational coherent anti-Stokes Raman scattering (CARS) measurements performed in highly scattering environments are susceptible to contamination by two-beam CARS signals generated by the pump–probe and Stokes–probe interactions at the measurement volume. If this occurs, differences in the Raman excitation bandwidth between the two-beam and three-beam CARS signals can add significant errors to the spectral analysis. This interference to the best of our knowledge has not been acknowledged in previous three-beam rotational CARS experiments, but may introduce measurement errors up to 25% depending on the temperature, amount of scattering, and differences between the two-beam and three-beam Raman excitation bandwidths. Here, the presence of two-beam CARS signal contamination was experimentally verified using a femtosecond–picosecond rotational CARS instrument in two scattering environments: (1) a fireball generated by a laboratory-scale explosion that contained particulate matter, metal fragments, and soot, and (2) a flow of air and small liquid droplets. A polarization scheme is presented to overcome this interference. By rotating the pump and Stokes polarizations +55° and –55° from the probe, respectively, the two-beam and three-beam CARS signals are orthogonally polarized and can be separated using a polarization analyzer. Using this polarization arrangement, the Raman-resonant three-beam CARS signal amplitude is reduced by a factor of 2.3 compared to the case where all polarizations are parallel. This method is successfully demonstrated in both scattering environments. A theoretical model is presented, and the temperature measurement error is studied for different experimental conditions. The criteria for when this interference may be present are discussed.

42 ENGINEERING↗

Enhanced Light Scattering of the Forbidden longitudinal Optical Phonon Mode Studied by Micro-Raman Spectroscopy on Single InN nanowires

In the literature, there are controversies on the interpretation of the appearance in InN Raman spectra of a strong scattering peak in the energy region of the unscreened longitudinal optical (LO) phonons, although a shift caused by the phonon-plasmon interaction is expected for the high conductance observed in this material. Most measurements on light scattering are performed on ensembles of InN nanowires (NWs). However, it is important to investigate the behavior of individual nanowires and here we report on micro-Raman measurements on single nanowires. When changing the polarization direction of the incident light from parallel to perpendicular to the wire, the expected reduction of the Raman scattering was observed for transversal optical (TO) and E2 phonon scattering modes, while a strong symmetry-forbidden LO mode was observed independently on the laser polarization direction. Single Mg- and Si-doped crystalline InN nanowires were also investigated. Magnesium doping results in a sharpening of the Raman peaks, while silicon doping leads to an asymmetric broadening of the LO peak. The results can be explained based on the influence of the high electron concentration with a strong contribution of the surface accumulation layer and the associated internal electric field.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Photoluminescence and Raman spectroscopy studies on polyaniline/PbI{sub 2} composite

Functionalization of PbI{sub 2} with conjugated polymers (polyaniline-emeraldine base (PANI-EB) or polyaniline-emeraldine salt (PANI-ES)) is demonstrated by Raman and luminescence studies. PbI{sub 2}/PANI hybrid material was prepared by electrochemical polymerization of aniline onto the PbI{sub 2} modified Pt electrode and mechanico-chemical reaction between the two constituents. PANI interacting with the PbI{sub 2} gives rise to new Raman bands at 80, 144 and 170 cm{sup -1}. First line reveals the formation of 'stacking faults' that disrupt the I-Pb-I layers stacking along the c axis by the insertion of polymer molecules. The bands at 144 and 170 cm{sup -1} are attributed to the vibrational mode associated with Pb-NHR''{sub 2} (R''=C{sub 6}H{sub 4}) bond. The functionalization of PbI{sub 2} with PANI-EB brings forth the PANI-ES form. Depending on the semiconducting (PANI-EB) or conducting (PANI-ES) properties of the polymer in the PbI{sub 2}/PANI intercalated material, a partial or total collection of the charges generated under band to band irradiation is revealed by photoluminescence studies. - Graphical abstract: Experimental illustration of the extending along the c axis of a PbI{sub 2} single crystal by an intercalation process. In (a) is shown a crystal slide cleaved from a Bridgman-grown PbI{sub 2} crystal ingot and in (b) the same sample intercalated with pyridine obtained after an exposure for 24 h in a saturated atmosphere of pyridine.

36 MATERIALS SCIENCE↗

Raman Spectroscopy Characterization of Se- Doped Bi{sub 12}SiO{sub 20} Crystals

Crystals of BSO doped with Se are successfully grown by the Czochralski method. The measured concentration of Se is 1.75x10{sup 18} cm{sup -3} and of Fe is 6.4x10{sup 18} cm{sup -3}, i.e. the concentration of Fe is significantly increased. It is assumed that the doping takes place through the replacement 3Si{sup 4+}->(Se{sup 6+}+2Fe{sup 3+}). The doping-induced shift of the Raman-active A, E and F-modes is not significant and it is concluded that the lattice distortions caused by doping are very small in BSO crystals doped with Se at low concentrations. The doping with Se at high concentration leads to occasional second phase inclusions. It is observed that all A, E and F- modes in the Raman spectrum are downshifted with 2-5 cm{sup -1}. It is concluded that the doping with Se at high concentrations follows the same mechanism as those with low concentrations but the introduced lattice distortions are more significant.

36 MATERIALS SCIENCE↗

Raman spectroscopy of KxCo2-ySe2 single crystals near the ferromagnet-paramagnet transition

Polarized Raman scattering spectra of the K x Co 2-y Se 2 (x = :::; y = :::) single crystals reveal the presence of two phonon modes, assigned as of the A1g and B1g symmetry. Absence of additional modes excludes the possibility of vacancy ordering, unlike in K x Co 2-y Se 2 . The ferromagnetic (FM) phase transition at Tc 74 K leaves a clear fingerprint on the temperature dependence of the Raman mode energy and linewidth. For T > Tc the temperature dependence looks conventional, driven by the thermal expansion and anharmonicity. The Raman modes are rather broad due to the electron-phonon coupling increased by the disorder and spin fluctuation e ects. In the FM phase the phonon frequency of both modes increases, while an opposite trend is seen in their linewidth: the A1g mode narrows in the FM phase, whereas the B 1g mode broadens. We argue that the large asymmetry and anomalous frequency shift of the B 1g mode is due to the coupling of spin fluctuations and vibration. Our density functional theory (DFT) calculations for the phonon frequencies agree rather well with the Raman measurements, with some discrepancy being expected since the DFT calculations neglect the spin fluctuations.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Development of a Raman Spectroscopy Technique to Detect Alternate Transportation Fuel Hydrocarbon Intermediates in Complex Combustion Environments

Spontaneous Raman spectra for important hydrocarbon fuels and combustion intermediates were recorded over a range of low-to-moderate flame temperatures using the multiscalar measurement facility located at Sandia/CA. Recorded spectra were extrapolated to higher flame temperatures and then converted into empirical spectral libraries that can readily be incorporated into existing post-processing analysis models that account for crosstalk from overlapping hydrocarbon channel signal. Performance testing of the developed libraries and reduction methods was conducted through an examination of results from well-characterized laminar reference flames, and was found to provide good agreement. The diagnostic development allows for temporally and spatially resolved flame measurements of speciated hydrocarbon concentrations whose parent is more chemically complex than methane. Such data are needed to validate increasingly complex flame simulations.

Ekoto, Isaac W.↗

Hydrocarbon-Fueled Rocket Plume Measurement Using Polarized UV Raman Spectroscopy

The influence of pressure upon the signal strength and polarization properties of UV Raman signals has been investigated experimentally up to pressures of 165 psia (11 atm). No significant influence of pressure upon the Raman scattering cross section or depolarization ratio of the N2 Raman signal was found. The Raman scattering signal varied linearly with pressure for the 300 K N2 samples examined, thus showing no enhancement of cross section with increasing pressure. However at the highest pressures associated with rocket engine combustion, there could be an increase in the Raman scattering cross section, based upon others' previous work at higher pressures than those examined in this work. The influence of pressure upon thick fused silica windows, used in the NASA Modular Combustion Test Article, was also investigated. No change in the transmission characteristics of the windows occurred as the pressure difference across the windows increased from 0 psig up to 150 psig. A calibration was performed on the UV Raman system at Vanderbilt University, which is similar to the one at the NASA-Marshall Test Stand 115. The results of this calibration are described in the form of temperature-dependent functions, f(T)'s, that account for the increase in Raman scattering cross section with an increase in temperature and also account for the reduction in collected Raman signal if wavelength integration does not occur across the entire wavelength range of the Raman signal. These functions generally vary only by approximately 10% across their respective temperature ranges, except for the case Of CO2, where there is a factor of three difference in its f(T) from 300 K to 2500 K. However this trend for CO2 is consistent with the experimental work of others, and is expected based on the low characteristic vibrational temperature Of CO2. A time-averaged temperature measurement technique has been developed, using the same equipment as for the work mentioned above, that is based upon high-spectral resolution UV Raman scattering. This technique can provide temperature measurements for flows where pressure cannot be measured.

Wehrmeyer, Joseph A.↗

Raman Spectroscopy as a Method for Mineral Identification on Lunar Robotic Exploration Missions

The sharp, nonoverlapping Raman bands for plagioclase, pyroxene, and olivine would be advantageous for on-surface, active mineralogical analysis of lunar materials. A robust, light-weight, low-power, rover-based Raman spectrometer with a laser exciting source, entirely transmission-mode holographic optics, and a charge-coupled device (CCD) detector could fit within a less than 20 cm cube. A sensor head on the end of an optical fiber bundle that carried the laser beam and returned the scattered radiation could be placed against surfaces at any desired angle by a deployment mechanism; otherwise, the instrument would need no moving parts. A modem micro-Raman spectrometer with its beam broadened (to expand the spot to 50-micrometer diameter) and set for low resolution (7/cm in the 100-1400/cm region relative to 514.5-nm excitation), was used to simulate the spectra anticipated from a rover instrument. We present spectra for lunar mineral grains, less than 1 mm soil fines, breccia fragments, and glasses. From frequencies of olivine peaks, we derived sufficiently precise forsterite contents to correlate the analyzed grains to known rock types and we obtained appropriate forsterite contents from weak signals above background in soil fines and breccias. Peak positions of pyroxenes were sufficiently well determined to distinguish among orthorhombic, monoclinic, and triclinic (pyroxenoid) structures; additional information can be obtained from pyroxene spectra, but requires further laboratory calibration. Plagioclase provided sharp peaks in soil fines and most breccias even when the glass content was high.

Wang, Alian↗

Single-cell raman spectroscopy for the non-destructive, non-invasive analysis of cells and cellular components

Raman spectra of cells, such as normal human T- and B-cells from peripheral blood or human tonsil and the corresponding transformed cells are obtained by optically trapping the cells and obtaining their Raman spectra. The trapped cells can be subjected to one, two, or more different excitation wavelengths, and each wavelength of the corresponding Raman spectra can be stored in a separate channel. In preferred embodiments, two spectra are subtracted from each other to give a difference spectrum and each channel is analyzed independently to characterize the trapped cell. Alternatively, the Raman spectrum can be subjected to Principal Component Analysis (PCA) in order to characterize the trapped cell. The trapped cell thus classified can be sorted, or further manipulated.

Chan, James W.↗

Combinations of NIR, Raman spectroscopy and physicochemical measurements for improved monitoring of solvent extraction processes using hierarchical multivariate analysis models

The reliability of chemical processes can be greatly improved by implementing inline monitoring systems. Combining multivariate analysis with non-destructive sensors can enhance the process without interfering with the operation. Here, we present here hierarchical models using both principal component analysis and partial least square analysis developed for different chemical components representative of solvent extraction process streams. A training set of 380 samples and an external validation set of 95 samples were prepared and Near infrared and Raman spectral data as well as conductivity under variable temperature conditions were collected. The results from the models indicate that careful selection of the spectral range is important. By compressing the data through Principal Component Analysis (PCA), we lower the rank of the data set to its most dominant features while maintaining the key principal components to be used in the regression analysis. Within the studied data set, concentration of five chemical components were modeled; total nitrate (NO 3 - ), total acid (H + ), neodymium (Nd 3+ ), sodium (Na + ), and ionic strength (I.S.). The best overall model prediction for each of the species studied used a combined data set comprised of complementary techniques including NIR, Raman, and conductivity. Finally, our study shows that chemometric models are powerful but requires significant amount of carefully analyzed data to capture variations in the chemistry.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Coherent anti-Stokes Raman spectroscopy - Spectra of water vapor in flames

The results of experimental measurements of the coherent anti-Stokes Raman spectra of water vapor in flames are reported. A pulsed, frequency-doubled neodymium laser was used to supply the pump beam and to pump a dye laser to provide a broadband Stokes beam at 6600 A. Spectra were obtained in the postflame region of a premixed methane-air flame in the Raman frequency shift region of the symmetric stretch mode (3651.7 kaysers) at an approximate temperature of 1675 K. A theoretical calculation of the coherent anti-Stokes Raman spectrum of water vapor at this temperature was made, taking into account only isotropic Q-branch transitions, and using the energy level data of Floud et al. (1976). The theoretical prediction is shown essentially to reproduce all qualitative features of the experimental spectrum, and to exhibit a strong temperature dependence.

Hall, R. J.↗

Intensified silicon photodiode array detector linearity Application to coherent anti-Stokes Raman spectroscopy

The linearity of an intensified silicon photodiode array multichannel detector is studied with coherent anti-Stokes Raman and other similar signals. Studies with diffuse and focused (spherically and cylindrically) signals resolved apparent saturation problems which limit the dynamic range of the detector. In addition, it has been shown that there is no short-range wavelength (473-532-nm) dependence on this saturation. Theoretical explanations for these phenomena are also included.

Antcliff, R. R.↗

Spatially Resolved Raman Spectroscopy of Thin Carbon Interphase in SiC Ceramic Matrix Composites

A dedicated analysis method is presented to extract the Raman spectrum of an interphase layer thinner than the laser spot size. We focused on spatial correlations between the contrast of optical micrographs and Raman hyperspectral data to predict the constituents of the mixed spectra measured near the interphase. By employing a mapping step size of 0.1 μm, the Raman spectrum of approximately 0.3-μm-thick carbon interphase in a SiC fiber-reinforced SiC matrix composite was extracted from data acquired with a theoretical spot size of about 0.7 μm. Notably, conventional chemometrics procedures were unable to isolate the interphase signal, instead producing a spectrum representing a mixture of interphase and matrix. This study used another composite with approximately 0.9-μm-thick interphase to validate the analysis method, enabling direct measurement of the interphase spectrum. The proposed Raman analysis method has advantages in specimen volume and turnaround time compared to traditional characterization methods, such as transmission electron microscopy. In conclusion, this study also evaluates the applicability of the analysis method to different composite materials and identifies key requirements of the measurements, including the ratio of interphase thickness to spot size and the homogeneity of the surrounding matrix.

ceramic matrix composite↗

Investigation of substitution effects and the phase transition in type-I clathrates Rb{sub x}Cs{sub 8-x}Sn{sub 44}square{sub 2} (1.3<=x<=2.1) using single-crystal X-ray diffraction, Raman spectroscopy, heat capacity and electrical resistivity measurements

The substitution of cations in Rb{sub x}Cs{sub 8-x}Sn{sub 44}square{sub 2}(1.3<=x<=2.1) is reported. The compounds crystallize at room temperature in the space group la3-bard adopting the type-I clathrate 2x2x2 superstructure with partly ordered framework vacancies (square), whereas at higher temperatures they transform to the primitive, more disordered modification (space group Pm3-barn). The guest atom distributions in the Sn cages on the Rb: Cs ratios is studied by means of single-crystal X-ray diffraction for Rb{sub 2.1(1)}Cs{sub 5.8(1)}Sn{sub 44} at T=293 K (1), Rb{sub 1.42(8)}Cs{sub 6.58(8)}Sn{sub 44} at T=293 K (2a), Rb{sub 1.46(5)}Cs{sub 6.54(5)}Sn{sub 44} at T=373 K (2b) and Rb{sub 1.32(8)}Cs{sub 6.68(8)}Sn{sub 44} at T=293 K (3). The structural order-disorder phase transition influences the electrical resistivity. The hysteresis observed for the electrical resistivity in combination with the symmetric shape of the specific heat anomaly suggests that the transformation is of first-order type and is characterized by an entropy change of about 2.5 J mol{sup -1} K{sup -1}. The Raman spectrum for the low-temperature modification of 2 is also reported. - Graphical Abstract: The effects of substitution of cations in the type-I clathrates Rb{sub x}Cs{sub 8-x}Sn{sub 44} (1.3<=x<=2.1) are reported. The distribution of the guests in the Sn cages under different reaction stoichiometries and annealing times is studied by X-ray diffraction. A structural phase transition in Rb{sub 1.4}Cs{sub 6.6}Sn{sub 44} at 333-363 K affects significantly the electrical resistivity and heat capacity.

36 MATERIALS SCIENCE↗

Raman spectroscopy: A tool to investigate alpha decay damage in a PuO 2 crystal lattice and determining sample age since calcination

Raman microspectroscopy can be used to measure local physical properties of materials, such as the lattice parameter. Alpha decay induced lattice damage of plutonium dioxide (PuO 2 ) results in the growth of new bands and broadening of the T 2g band. A relationship between the change in the lattice parameter and storage time has been established in the literature using X-ray diffraction (XRD). In this work, our measured time-dependent Raman spectra of PuO 2 particulates matches the XRD results. This new Raman spectroscopic technique can provide dating information on the time elapsed since the last calcination of PuO 2 using a single >5 μm particulate in contrast to 50 mg of 10–50 μm particles required by XRD.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Metallized Capillaries as Probes for Raman Spectroscopy

A class of miniature probes has been proposed to supplant the fiber-optic probes used heretofore in some Raman and fluorescence spectroscopic systems. A probe according to the proposal would include a capillary tube coated with metal on its inside to make it reflective. A microlens would be hermetically sealed onto one end of the tube. A spectroscopic probe head would contain a single such probe, which would both deliver laser light to a sample and collect Raman or fluorescent light emitted by the sample.

Pelletier, Michael↗