Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Radiological”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Distribution of Natural Radionuclides at the Nevada National Security Site

According to the United Nations Scientific Committee on the Effects of Atomic Radiation (UNSCEAR) publications, contributions of terrestrial gamma doses are mainly from the presence of 40 K, and of 238 U and 232 Th together with their progeny in various rocks and soils. A survey of soil distributions of radionuclides 40 K, 238 U, and 232 Th was performed at the Nevada National Security Site (NNSS) using in situ gamma-ray spectrometry with a high-purity germanium (HPGe) detector. The average activity concentrations of 40 K, 238 U, and 232 Th in natural soils at the NNSS are 867 Bq kg -1 (range from 150 ± 8 to 1297 ± 56 Bq kg -1 ), 50 Bq kg -1 (range from 29 ± 3 to 74 ± 8 Bq kg -1 ), and 56 Bq kg -1 (range from 11 ± 2 to 96 ± 10 Bq kg -1 ), respectively. The concentration at each location is significantly associated with its geological lithology. The terrestrial gamma dose rates around the NNSS were estimated from 26 to 144 nSv h -1 with mean value of 93 nSv h -1 . In conclusion, our results provide useful information about the natural background radiation and radiological effects of naturally occurring radionuclides at the NNSS.

environmental assessment↗

Towards a Comparative Assessment of Data-Driven Process Models in Health Information Technology

Process mining for conformance analysis focuses on comparing a reference process model against a data-driven process model that is generated via log files from information technology systems. While this approach is helpful when there is an existing process model in an organization, it leaves the question of what to do in the absence of a complete reference process model unanswered. In this paper, we present a comparative assessment approach that combines process mining, process mapping for dimensionality reduction, and statistical analysis. Our goal is to find similarities and dissimilarities in data-driven process models among U.S. Veterans Health Administration (VHA) facilities to assess process conformance among different healthcare facilities, which can help assess the standardization of care. We illustrate our approach by applying it to two clinical radiology order process models generated by two similar facilities. Our results demonstrate statistical similarities in the standardization of care among those two facilities.

Klasky, Hilda↗

A multi-modal scanning system to digitize CBRNE emergency response scenes

A handheld system developed to digitize a contextual understanding of the scene at a chemical, biological, radiological, nuclear and/or explosives (CBRNE) events is described. The system uses LiDAR and cameras to create a colorized 3D model of the environment, which helps domain experts that are supporting responders in the field. To generate the digitized model, a responder scans any suspicious objects and the surroundings by carrying the system through the scene. The scanning system provides a real-time user interface to inform the user about scanning progress and to indicate any areas that may have been missed either by the LiDAR sensors or the cameras. Currently, the collected data are post-processed on a different device, building a colorized triangular mesh of the encountered scene, with the intention of moving this pipeline to the scanner at a later point. The mesh is sufficiently compressed to be sent over a reduced bandwidth connection to a remote analyst. Furthermore, the system tracks fiducial markers attached to diagnostic equipment that is placed around the suspicious object. The resulting tracking information can be transmitted to remote analysts to further facilitate their supporting efforts. The paper will discuss the system's design, software components, the user interface used for scanning a scene, the necessary procedures for calibration of the sensors, and the processing steps of the resulting data. The discussion will close by evaluating the system's performance on 11 scenes.

Salathe, Marco↗

Generation of Synthetic Data for a Radiation Detection Algorithm Competition

This paper details the generation of synthetic radiation data using large-scale Monte Carlo transport models to evaluate radiation search detection algorithms. Modular 3-D Monte Carlo models spanning multiple city blocks were constructed, loosely based on downtown Knoxville, TN, containing buildings composed of multiple materials (brick, granite, and concrete), sidewalks, a four-lane road, side streets, parking lots, and grassy fields. Background and simulated source detector response calculations from these models were used to create synthetic list mode data sets for a 2"×4"×16" NaI(Tl) detector moving through a city street at a constant speed. For the background simulations, major isotopes were computed individually so that background composition and variability could be computed efficiently outside Monte Carlo. The source detector response included six simulated sources placed at 15 source locations. Detector response was developed to be periodic through the city street so that a detector path could begin at one end of the model and wrap around to the other. This framework allowed for the creation of diverse data sets, each with its own unique background and simulated source detector response. Synthetic data allows for high-quality labels, which are useful in developing data-driven radiation detection algorithms. This methodology was used to create synthetic data sets which were released as part of a public data competition to spur the development of new radiation detection algorithms for radiological search applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Efficient Prompt Scintillation and Fast Neutron-Gamma Ray Discrimination Using Amorphous Blends of Difluorenylsilane Organic Glass and in-situ Polymerized Vinyltoluene

High performance radiation detection materials are an integral part of national security, medical imaging, and nuclear physics applications. Those that offer compositional and manufacturing versatility are of particular interest. In this work, we report a new family of radiological particle-discriminating scintillators containing bis(9,9-dimethyl-9H-fluoren-2- yl)diphenylsilane (compound “P2”) and in-situ polymerized vinyltoluene (PVT) that is phase stable and mechanically robust at any blend ratio. The gamma-ray light yield increases nearly linearly across the composition range, to ~16,400 photons/MeV at 75 % wt. P2. These materials are also capable of γ/n pulse shape discrimination (PSD) and between 20-50 % P2 loading are competitive with the PSD quality of commercially-available plastic scintillators. The 137 Cs scintillation rise and decay times are sensitive to P2 loading and approach the values for “pure” P2. Additionally, the radiation detection performance of P2-PVT blends can be made stable in 60°C air for at least 1.5 months with the application of a thin film of poly(vinylalcohol) to the scintillator surfaces.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Machine Learning-Based Extreme Data Reduction for Prompt Supernova Pointing at DUNE

One of the goals of the Deep Underground Neutrino Experiment (DUNE) is to use the massive underground liquid argon time projection chamber (LArTPC) detectors at its far site for multimessenger astronomy (MMA), in the detection of neutrinos from core-collapse supernovae (SNe). Its current baseline trigger strategy detects activity in the detector that is consistent with supernova (SN) neutrinos and saves the raw data for further offline analysis but provides no prompt pointing information crucial for optical follow-ups by other observatories. This approach is based on the assumption that prompt pointing determination using raw data is computationally prohibitive. In this article, we demonstrate a proof-of-concept based on applying extreme data reduction on the buffered SN data in the DUNE data acquisition (DAQ) system’s front-end computers using a machine learning (ML) workflow. This reduces the data by ~5 orders of magnitude, allowing a full track reconstruction to be carried out quickly on a single server. The total time to perform the ML-based data reduction and the full track reconstruction is less than the time to transfer the SN data back to Fermilab or a high-performance computing (HPC) center. This shows that prompt processing of raw SN data is possible and, in fact, trivial once the data have been reduced to reject radiological backgrounds, paving the way to a high-quality SN pointing trigger that is based on fully reconstructed data instead of trigger primitives (TPs).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

CAMIS: A Cylindrical Active Mask Imaging System

Detecting and locating radiological and nuclear materials at distances of 10 m or more in urban and cluttered environments continues to pose challenges in nuclear security and proliferation detection. Previous approaches have focused on large-area radiation imaging using planar configurations of detectors and passive masks. However, these approaches suffer from limitations such as limited field-of-view (FOV) and reduced detection efficiency due to absorption in the mask. To address these limitations, we have developed the cylindrical active mask imaging system (CAMIS). This system comprises 128 NaI(Tl) (10 cm)3 detectors. These detectors are arranged in a cylindrical configuration, enabling gamma-ray imaging with a full 360° azimuthal FOV. The active mask elements within the system are arranged in a pseudorandom configuration, providing unique encoding for all incident directions within the FOV. CAMIS offers an effective detection area of approximately 1 m2 across the entire 360° FOV in the horizontal plane, achieving a mean angular resolution of 10.9° in the azimuthal direction and 12.9° in the polar direction measured by taking the full-width at half-maximum (FWHM) of a cross-section at the maximum reconstructed intensity.

Lamb, C↗

RADAI: A Large-Scale Realistic Dataset for Radiation Detection Algorithm Development

Open, realistic datasets are essential for developing and benchmarking radiation detection algorithms, yet they remain scarce. The Radiological Anomaly Detection and Identification (RADAI) project was develop to create datasets that meet the training and testing needs for sophisticated radiation detection algorithms. The RADAI dataset is a large-scale synthetic resource that integrates high-fidelity Monte Carlo simulations with realistic urban scenarios to capture both background variability and source signatures. RADAI models construction-material NORM, people and vehicles, urban clutter, and dynamic environmental effects such as cosmic-ray and rain-induced transients, and they provide list-mode detector data with motion and response modeling suitable for algorithm training and evaluation. The RADAI project resulted in three publicly-released complementary datasets together with an online scoring portal for standardized performance assessment and an open software toolkit that supports data access, augmentation, model development, and evaluation. These resources enable reproducible comparisons across methods and promote rigorous studies at the scale required by contemporary machine learning. By grounding algorithm development in realistic, well-documented conditions, RADAI supports progress toward more robust detection, identification, and localization in complex urban environments.

Ghawaly, James M. [Division of Computer Science an↗

“Figure‐of‐Eight” Suture‐Button Technique for Fixation of Displaced Anterior Cruciate Ligament Avulsion Fracture

Objective To assess the clinical results of the “figure‐of‐eight” suture‐button technique in the arthroscopic treatment of anterior cruciate ligament (ACL) tibial avulsion fractures. Methods This was a retrospective study reviewing data from September 2013 to June 2019. A total of 27 patients (13 males and 14 females) who underwent arthroscopic “figure‐of‐eight” suture‐button fixation for displaced ACL avulsion fractures were analyzed. The mean age of the patients in the sample was 15.8 years (10–29 years), with a mean follow‐up of 24 months (6–48 months). According to Meyers–McKeever classification, 11 patients were classified as type III and 16 as type IV. All patients were evaluated following the guidelines of the radiological union, the Lysholm knee scoring scale, and the International Knee Documentation Committee (IKDC). Results Fractures were united within 3 months after surgery in all 27 cases. During the last follow‐up, all the anterior drawer and Lachman tests were negative, except in 1 patient whose anterior drawer test was 1° positive. The range of motion was improved from 72.22° ± 27.92° before surgery to 137.78° ± 7.38° at the last follow‐up ( P < 0.05); the Lysholm score was improved from 45.81 ± 10.94 before surgery to 93.04 ± 5.66 at the last follow‐up ( P < 0.05); and the IKDC score was increased from 43.89 ± 11.16 before surgery to 90.26 ± 5.86 at the last follow‐up ( P < 0.05). In 1 patient, an inflammatory reaction was observed at the medial incision of the tibial tubercle; the symptoms disappeared with administration of antibiotics for 1 week. All patients returned to their preinjury physical activities at the last follow‐up. Conclusion The “figure‐of‐eight” suture‐button technique achieves a satisfactory clinical outcome and provides an effective method for the treatment of displaced ACL avulsion fractures.

Kuang, Shi‐da↗

Ecological information and approaches needed for risk communication dialogs for acute or chronic environmental crises

Scientists, social scientists, risk communicators, and many others are often thrust into a crisis situation where they need to interact with a range of stakeholders, including governmental personnel (tribal, U.S. federal, state, local), local residents, and other publics, as well as other scientists and other risk communicators in situations where information is incomplete and evolving. This paper provides: (1) an overall framework for thinking about communication during crises, from acute to chronic, and local to widespread, (2) a template for the types of ecological information needed to address public and environmental concerns, and (3) examples to illustrate how this information will aid risk communicators. The main goal is providing an approach to the knowledge needed by communicators to address the challenges of protecting ecological resources during an environmental crisis, or for an on-going, chronic environmental issue. To understand the risk to these ecological resources, it is important to identify the type of event, whether it is acute or chronic (or some combination of these), what receptors are at risk, and what stressors are involved (natural, biological, chemical, radiological). For ecological resources, the key information a communicator needs for a crisis is whether any of the following are present: threatened or endangered species, species of special concern, species groups of concern (e.g., neotropical bird migrants, breeding frogs in vernal ponds, rare plant assemblages), unique or rare habitats, species of commercial and recreational interest, and species/habitats of especial interest for medicinal, cultural, or religious activities. Communication among stakeholders is complicated with respect to risk to ecological receptors because of differences in trust, credibility, empathy, perceptions, world view valuation of the resources, and in many cases, a history of misinformation, disinformation, or no information. Exposure of salmon spawning in the Columbia River to hexavalent chromium from the Hanford Site is used as an example of communication challenges with different stakeholders, including Native Americans with Tribal Treaty rights to the land.

54 ENVIRONMENTAL SCIENCES↗

Pressurization Analysis for Heating of a Screw Top Utility Can Loaded With Plutonium Oxide Powder by a 1273 K Fire

The documented safety analysis for the Savannah River National Laboratory (SRNL) evaluates the consequences of a postulated 1273 K fire in a glovebox. The radiological dose consequences for a pressurized release of plutonium oxide powder during such a fire depend on the maximum pressure that is attained inside the oxide storage containers. The oxide storage configuration selected for analysis is can/bag/can, comprised of oxide powder inside an 8.38 × 10 -6 m 3 stainless steel B vial inside 0.006 kg of polyethylene bagging inside a one-quart screw top utility can of the type commonly used to package solvents or rubber cements. To enable evaluation of the dose consequences, temperature and pressure transients have been calculated for exposure of a typical set of storage containers to the fire. The pressurization analysis credits venting to and from the B vial but does not credit venting or leakage from the can. Due to the low rate of venting from the B vial into the can gas space, the can pressure is nearly independent of the B vial pressure. Calculated maximum pressures are compared to the utility can burst pressure. In lieu of a structural analysis of the utility cans, burst pressures and leakage rates were measured using compressed nitrogen gas. The measured gauge burst pressure was 0.250 ± 0.043 MPa. The measured burst pressures are lower than the calculated maximum pressure due to fire exposure, indicating that the utility cans could burst during exposure to a 1273 K fire.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Using 3D Measurements from MRI to Improve VVUQ

Magnetic resonance velocimetry (MRV) is a diagnostic that can measure 3D, three-component turbulent velocity fields in arbitrarily complex flow configurations. The approach uses magnetic resonance imaging (MRI), which is a system commonly available in radiology departments or medical research centers. MRV acquires signal from hydrogen protons in water channel flows. Despite the obvious utility of the measurements for investigating a variety of flows, comparisons with computational fluid dynamic (CFD) simulations largely retain traditional metrics, comparing velocity profiles and planes at discrete regions within the flow rather than using the 3D nature of the measured field. In this effort, MRV was conducted in a simple water channel with six spanwise-centered periodic obstacles roughly shaped as cubes. At a fully turbulent Reynolds number of 15,000, the channel includes two flows: a main streamwise flow and, in the wake of the second obstacle, an injected flow oriented perpendicular to the streamwise flow. The flow geometry includes partial obstacles on the side walls and is inherently 3D because of the interaction of the two streams and the wake features, making the flow challenging to completely measure with traditional optical techniques. Aside from line profiles and planar comparisons, two 3D metrics are used to compare the data with a steady Reynolds-averaged Navier–Stokes (RANS) simulation result. A brief discussion about the comparison is provided, including comments about uncertainty.

Benson, Mike [ORNL] (ORCID:000000023210116X)↗

Automated nuclear cloud feature extraction from film

Chemical, biological, radiological, nuclear, and explosives incidents require rapid detection and characterization for appropriate response. For a nuclear detonation, visible-light cameras may be used to locate the cloud and characterize fallout deposition when coupled with numerical models. Films from the United States’ nuclear testing era compose the only sizeable collection of imagery depicting high-yield detonations. These films offer unique insights into characteristics of flows involving scales that are difficult to replicate experimentally, and they are a valuable source of data for the validation of models for nuclear fallout transport, either as part of emergency response or forensic activities. In this work, we implement modern computer vision and machine learning techniques to identify and track the cloud automatically and subsequently determine the time dependence of some of its features. We trained a ResNet-18 image classifier on hundreds of images to categorize nuclear cloud morphology. Each category or cloud regime is determined by early cloud evolution and is associated to constitutive properties of the flow, such as distribution of vorticity. Next, we identified keypoint features using the KAZE algorithm and tracked these keypoints in the images, allowing us to determine the dimensions and velocities of the cloud across film frames. These measurements converted to real-world units provide valuable experimental data that can be used in the development and validation of nuclear cloud models. We compared the results of this method against manual cloud rise measurements from two different films. In one, our automated method accelerated the feature extraction process without sacrificing measurement accuracy.

Khristy, Joel [ORNL] (ORCID:0000000209963060)↗

A Review of Doses for Dental Imaging in 2010–2020 and Development of a Web Dose Calculator

Dental imaging is one of the most common types of diagnostic radiological procedures in modern medicine. We introduce a comprehensive table of organ doses received by patients in dental imaging procedures extracted from literature and a new web application to visualize the summarized dose information. We analyzed articles, published after 2010, from PubMed on organ and effective doses delivered by dental imaging procedures, including intraoral radiography, panoramic radiography, and cone-beam computed tomography (CBCT), and summarized doses by dosimetry method, machine model, patient age, and technical parameters. Mean effective doses delivered by intraoral, 1.32 (0.60–2.56) μSv, and panoramic, 17.93 (3.47–75.00) μSv, procedures were found to be about1% and 15% of that delivered by CBCT, 121.09 (17.10–392.20) μSv, respectively. In CBCT imaging, child phantoms received about 29% more effective dose than the adult phantoms received. The effective dose of a large field of view (FOV) (>150 cm2) was about 1.6 times greater than that of a small FOV (<50 cm2). The maximum CBCT effective dose with a large FOV for children, 392.2 μSv, was about 13% of theeffective dose that a person receives on average every year from natural radiation, 3110 μSv. Monte Carlo simulations of representative cases of the three dental imaging procedures were then conducted to estimate and visualize the dose distribution within the head. The user-friendly interactive web application (available at http://dentaldose.org) receives user input, such as the number of intraoral radiographs taken, and displays total organ and effective doses, dose distribution maps, and a comparison with other medical and natural sources of radiation. The web dose calculator provides a practical resource for patients interested in understanding the radiation doses delivered by dental imaging procedures.

Lee, Hawon↗

Multi-modal Free-moving Data Fusion (MFDF) v1.0

Multi-modal Free-moving Data Fusion (MFDF) is a python package that implements low and high-level functionality for performing qualitative and quantitative gamma-ray imaging analyses. Such analyses enable the use of gamma-ray spectrometers and/or imagers to estimate the distribution and quantity of radiological materials in an environment. Free-moving 3D imaging requires additional information about the 3D trajectory and orientation of the system, however all of these methods can be applied to 2D static gamma-ray imaging as well. The package includes methods (MLEM and MAP) for distributed source reconstruction, methods (PSL) for point source reconstruction, the ability to ingest and utilize quantitative detector response functions (for absolute analyses), and the ability to perform 3D estimation of dose-rates from quantitative reconstructions.

Joshi, Tenzing↗

Python Urban Deployment Model (PyUDM) v1.0.0

The Python Urban Deployment Model (PyUDM) is a simulation tool used to investigate networks of static radiation detectors in urban environments. PyUDM simulates traffic, stationary NaI gamma-ray detectors, and moving radioactive sources on simulated vehicles. The analyzed output of the simulations contain valuable insights into the performance of different configurations of urban radiological detector configurations such as their ability to detect sources moving through the environment. To accurately simulate radioactive material moving through urban environments, PyUDM combines Monte Carlo simulation tools, publicly available map and traffic data, and measured gamma-ray spectra from urban environments.

Rofors, Emil↗

Ecological Benchmark for Radionuclides

The Ecological Benchmark Tool for radionuclides dataset serves as a comprehensive repository of benchmarks designed to assess ecological risks at contaminated sites. This tool facilitates the evaluation of various environmental media and contaminants, supporting regulatory compliance and ecological protection. Benchmarks are available for sediment, soil, and surface water. The dataset also provides species-specific benchmarks for fish, plants, birds, mammals, and invertebrates. Users can select benchmark sources, media, individual radionuclides, and retrieve results in tabular or spreadsheet formats for analysis. Benchmarks are derived from authoritative sources, including government agencies, scientific councils, and academic publications. The dataset supports ecological risk assessments, regulatory decision-making, and environmental planning, with tools for benchmarking against radiological thresholds, sensitive species protection, and habitat impact evaluations. This structured approach ensures a robust evaluation of ecological risks tailored to site-specific and regulatory needs.

Stewart, Debra [Oak Ridge National Laboratory (ORN↗

RAIS Slope Factors for Radionuclides

For a given radionuclide, Slope Factors (SFs) represent the ELCR equivalent per unit intake (i.e., ingestion or inhalation) or external exposure of that radionuclide. These SFs are used to convert a radionuclide concentration in soil, air, water, or foodstuffs to a radiation ELCR. The primary use of SFs, also called risk coefficients, is to compute the ELCR resulting from site-related exposures. This is accomplished by multiplying the route-specific SF by the CDI of each radionuclide of potential concern for each route of exposure. Ingestion and inhalation slope factors are central estimates in a linear model of the age-averaged, lifetime attributable radiation cancer incidence (fatal and nonfatal cancer) risk per unit of activity inhaled or ingested, expressed as risk/picocurie (pCi). External exposure SFs are central estimates of lifetime attributable radiation cancer incidence risk for each year of exposure to external radiation from photon-emitting radionuclides distributed uniformly in a thick layer of soil, expressed as risk/year per pCi/gram soil. External exposure SF units can also be risk/year per pCi/square centimeters (cm2) of soil. When combined with site-specific media concentration data and appropriate exposure assumptions, SFs can be used to estimate lifetime cancer risks to members of the general population due to radionuclide exposures. The SFs presented on are updated values from Federal Guidance Report (FGR) 13 supplement using the International Commission on Radiological Protection (ICRP) 107 decay data. The derivation and values are found in “Calculations of Slope Factors and Dose Coefficients” (ORNL, 2014).

Noto, Katie [Oak Ridge National Laboratory (ORNL),↗