Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Radiation Detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

ECEI characterization of pedestal fluctuations in quiescent H-mode plasmas in DIII-D

Here, electron cyclotron emission imaging (ECEI) is employed to characterize the magneto hydraulics dynamics (MHD) fluctuations at the quiescent H-mode pedestals in DIII-D. Pedestal MHD fluctuations cause ECE radiation temperature fluctuations $\delta {T_{e{\text{,rad}}}}$ in both the pedestal and scrape-off-layer (SOL). A synthetic ECE platform is utilized for detailed interpretation of the ECEI signals in the SOL and pedestal regions. It is observed that the ECE radiation $\delta {T_{e{\text{,rad}}}}$, which is located in the SOL region according to the cold and optically thick plasma resonance assumption, is extremely sensitive to MHD radial displacements near the separatrix, exhibiting radiation inversion to $\delta {T_{e{\text{,rad}}}}$ at the pedestal. Here, the radiation inversion refers to the opposite phase between the radiation fluctuation at the pedestal and the radiation fluctuation at the SOL. Consequently, the quasi-coherent MHD (QCM), which displays a radiation inversion, is found to be consistent with an MHD radial structure that has a strong displacement near the separatrix. In contrast, the edge harmonic oscillation (EHO), which displays weak or no inversion, is found to be consistent with an MHD radial displacement structure peaking at the pedestal top. The ECEI data, interpreted with synthetic ECE, are in qualitative agreement with beam emission spectroscopy measurements on DIII-D for the relative radial extent and localization of the EHO and QCM. The high sensitivity of ECE radiation to separatrix displacements can be used to detect turbulence or MHD fluctuations near the separatrix, which may affect the transport across the separatrix and the wetted area in the divertor. The $\delta {T_{e{\text{,rad}}}}$ inversion measured with an ECE or ECEI system potentially provides important information on the magnetic field $\left| {{B_{{\text{sep}}}}} \right|$ at the separatrix, which helps constrain the pedestal equilibrium reconstruction and achieve an unambiguous mapping of the ECE/ECEI system with respect to the separatrix.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Characterizing Canopy Openness in Open Forests: Spherical Densiometer and Canopy Photography Are Equivalent but Less Sensitive than Direct Measurements of Solar Radiation

In forest ecosystems, canopy openness affects understory light availability, plant growth, and tree species recruitment, thus shaping future forest composition, structure, and functional diversity. Foresters must correctly and quickly measure canopy openness to meet their management objectives. To help guide the selection of an appropriate method for measuring canopy openness, we compared three common techniques that vary in cost, complexity, and time required for measurements and data processing: smartphone-based hemispherical photography, spherical densiometer measurements, and direct measurements of solar radiation (using AccuPAR ceptometer). We measured canopy openness using these three methods on 28 permanent forest health monitoring plots in pine-oak forests of the Central Pine Barrens of Long Island in New York State. By analysis of variance and regression analyses, we found the three methods (particularly densiometer and hemispherical photographs) yielded broadly equivalent and strongly positively correlated descriptions of canopy openness. The direct measurements of solar radiation seemed to have a greater potential to detect subtle variation in forest understory light. Forest managers may sufficiently characterize canopy openness using quick and cheap methods (e.g., spherical densiometers) and avoid larger costs of devices for direct light measurements (e.g., ceptometers) and the larger data processing times of hemispherical photography.

54 ENVIRONMENTAL SCIENCES↗

Measurement of Electron-Neutrino Charged-Current Cross Sections on 127 I with the COHERENT NaI$ν$E Detector

Using an 185-kg NaI[Tl] array, COHERENT has measured the inclusive electron-neutrino chargedcurrent cross section on 127 I with pion decay-at-rest neutrinos produced by the Spallation Neutron Source at Oak Ridge National Laboratory. Iodine is one the heaviest targets for which low-energy (≤ 50 MeV) inelastic neutrino-nucleus processes have been measured, and this is the first measurement of its inclusive cross section. After a five-year detector exposure, COHERENT reports a flux-averaged cross section for electron neutrinos of ${9.2}_{–1.8}^{+2.1}$ × 10 –40 cm 2 . This corresponds to a value that is ~41% lower than predicted using the MARLEY event generator with a measured Gamow-Teller strength distribution. In addition, the observed visible spectrum from charged-current scattering on 127 I has been measured between 10 and 55 MeV, and the exclusive zero-neutron and one-or-more-neutron emission cross sections are measured to be ${5.2}_{–3.1}^{+3.4}$ × 10 –40 and ${2.2}_{—2.2}^{+3.5}$ × 10 –40 cm 2 , respectively.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

First Measurement of $𝜈_𝑒$ and $\bar{𝜈}_𝑒$ Charged-Current Single Charged-Pion Production Differential Cross Sections on Argon Using the MicroBooNE Detector

Understanding electron neutrino interactions is crucial for measurements of neutrino oscillations and searches for new physics in neutrino experiments. We present the first measurement of the flux-averaged $𝜈_𝑒$ + $\bar{𝜈}_𝑒$ charged-current single charged-pion production cross section on argon using the MicroBooNE detector and data from the NuMI neutrino beam. The total cross section is measured to be [0.93 ± 0.13⁢(stat) ± 0.27⁢(syst)] × 10 −39 cm 2 /nucleon at a mean $𝜈_𝑒$ + $\bar{𝜈}_𝑒$ energy of 730 MeV. Differential cross sections are also reported in electron energy, electron and pion angles, and electron-pion opening angle.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Probing neutrino mass models through resonances at neutrino telescopes

We study the detection prospects of relatively light charged scalars in radiative Majorana neutrino mass models, such as the Zee model and its variants using scalar leptoquarks, at current and future neutrino telescopes. In particular, we show that these scalar mediators can give rise to Glashow-like resonance features in the ultrahigh energy (UHE) neutrino event spectrum at the IceCube neutrino observatory and its high-energy upgrade IceCube-Gen2. The same scalars can also give rise to observable nonstandard neutrino interactions (NSIs), and we show that the UHE neutrinos provide a complementary probe of NSI. We also discuss an interesting possibility of producing such resonances by incoming sterile neutrino components in the case where neutrinos are pseudo-Dirac particles.

Physics↗

Geant4 Simulations and Experimental Results for the Pacific-Ocean Neutrino Experiment (P-ONE)

The Pacific-Ocean Neutrino Experiment (P-ONE) is an upcoming large-volume neutrino telescope planned to be built off the coast of Vancouver Island, Canada. It aims to detect high-energy neutrinos via the Cherenkov radiation produced in water by secondary particles born from high-energy neutrino interactions. Its first set of detectors is planned to be commissioned this year. However, since the telescope is still in its early stages of development, many tests and simulations must still be run to characterize the efficacy of the detectors. One necessary simulation must be devoted towards examining whether the polarization of the incoming Cherenkov light impacts the strength of the signals by the PMTs, and it must be supported by experimental data. In this report, I detail what I have completed during my SULI internship at the Los Alamos National Lab (LANL); I present the preliminary results of a Geant4 polarization simulation as well as preliminary laboratory measurements that will later be used to inform the future P-ONE design.

74 ATOMIC AND MOLECULAR PHYSICS↗

Leveraging machine learning to enhance aerosol classification using Single-Particle Mass Spectrometry

Advancing automated classification of atmospheric aerosols from Single-Particle Mass Spectrometry (SPMS) data remains challenging due to overlapping ion signatures, compositional diversity, and limited labeled data. This study evaluates supervised and semi-supervised learning frameworks to enhance aerosol identification by jointly leveraging labeled and unlabeled spectra. Four models were compared: a supervised Support Vector Machine (SVM), a self-training SVM, a stacked autoencoder classifier, and a stacked autoencoder trained using a temporal-ensembling Mean Teacher approach. All models achieved high and stable accuracies (90.0 %–91.1 %), surpassing previous results on the same dataset (87 %) and matching the performance of state-of-the-art deep learning methods. Despite small global metric differences (≤ 1 %), semi-supervised variants yielded up to 5 %–10 % improvements for compositionally rare particle types – such as soot (0.77 % of spectra, F1-score: 0.93–0.97) and hazelnut pollen (0.98 % of spectra, F1-score: 0.97–1.00) – equating to roughly ∼ 187 additional correctly classified spectra. These gains are scientifically significant, as such rare particles exert disproportionate influence on radiative absorption and ice nucleation processes; their improved detection reduces modeled uncertainties in aerosol absorption optical depth and mixed-phase cloud ice nucleation rates. The models' residual misclassifications (≈ 9 %) largely arise from true spectral overlap among chemically adjacent species (e.g., Na- vs. K-feldspar, coated vs. uncoated feldspars), reflecting physical compositional continuity rather than algorithmic error. Collectively, these findings demonstrate that leveraging unlabeled data to learn robust spectral representations and refine classification enhances both fidelity and interpretability, bridging data-driven analysis with aerosol–climate process understanding.

54 ENVIRONMENTAL SCIENCES↗

Active Neutron Interrogation as a Method for Verification of the Absence of Special Nuclear Material in Arms Control Dismantlement

The next step in arms control reductions will deal with both strategic and non-strategic weapons, presenting new and hard challenges for verification. One verification approach that might be used in support of these reductions is the concept of deferred verification, which forgoes inspections at sensitive nuclear sites and relies on an inspection regime having access to the open segment of a State's nuclear sector, in "monitored transfer zones." A component of this approach is the anticipated need for an instrument suite capable of detecting well-shielded highly-enriched uranium or plutonium where it isn't supposed to be. This specific need was recently identified by the United Nations Institute for Disarmament Research in an enabling operating concept they call "contain and dispose." At the foundation of this approach is the idea that items declared as "not nuclear" are, by definition, not treaty limited and are thus "fair-game" for inspection and questioning. Active Neutron Interrogation (ANI), using beta-delayed neutron emissions as the signature for special nuclear material (SNM) detection, is a promising method to address this challenge. The method is quick, has high sensitivity and high specificity for detecting shielded SNM, is robust against changing background radiation environments, is robust against the presence of unknown shielding, and avoids the use of gamma-ray spectrometry which may introduce complications due to the potential release of sensitive information. This paper will present recent research activities exploring technical aspects of using ANI as a FAIRGAME verification method and discuss future prospects and research needs

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Evaluating Radiation Impact on Superconducting Transmon Qubits in Above and Underground Facilities

Superconducting qubits can be sensitive to sudden energy deposits into the substrate from cosmic rays and ambient radioactivity. While previous studies have primarily focused on exploring correlated effects over time and distance due to cosmic rays, this study uniquely offers a direct comparison of a transmon qubit's response at Fermilab SQMS above-ground facilities and the deep-underground Gran Sasso Laboratory (INFN-LNGS, Italy). Despite the vastly different radiation environments, we observe a similar average qubit lifetime (T1) of approximately 80 microseconds at both sites. We then employ a fast decay detection protocol and investigate the time structure, sensitivity, and relative rates of triggered events due to radiation versus intrinsic noise. We compare the above and underground performance of several high-coherence qubits with similar designs. Our findings reveal no significant difference in events with radiation-like signatures between above-ground and underground conditions for these sapphire and niobium-based transmon qubits. This suggests that most such events are likely due to other noise sources, which predominantly contribute to single-qubit errors in contemporary transmon qubits. By exposing the qubits to gamma sources with varying activity levels, we further evaluate their response to radiation in a low-background environment. The results show that qubits can indeed detect particle impacts; however, this capability is only realized by substantially reducing other noise sources, which in turn affects detection efficiency [1].

Roy, Tanay↗

Detecting Arsenic Contamination Using Satellite Imagery and Machine Learning

Arsenic, a potent carcinogen and neurotoxin, affects over 200 million people globally. Current detection methods are laborious, expensive, and unscalable, being difficult to implement in developing regions and during crises such as COVID-19. This study attempts to determine if a relationship exists between soil’s hyperspectral data and arsenic concentration using NASA’s Hyperion satellite. It is the first arsenic study to use satellite-based hyperspectral data and apply a classification approach. Four regression machine learning models are tested to determine this correlation in soil with bare land cover. Raw data are converted to reflectance, problematic atmospheric influences are removed, characteristic wavelengths are selected, and four noise reduction algorithms are tested. The combination of data augmentation, Genetic Algorithm, Second Derivative Transformation, and Random Forest regression (R 2 =0.840 and normalized root mean squared error (re-scaled to [0,1]) = 0.122) shows strong correlation, performing better than past models despite using noisier satellite data (versus lab-processed samples). Three binary classification machine learning models are then applied to identify high-risk shrub-covered regions in ten U.S. states, achieving strong accuracy (=0.693) and F1-score (=0.728). Overall, these results suggest that such a methodology is practical and can provide a sustainable alternative to arsenic contamination detection.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Final state radiation from high and ultrahigh energy neutrino interactions

Charged leptons produced by high-energy and ultrahigh-energy neutrinos have a substantial probability of emitting prompt internal bremsstrahlung ν ℓ + N → ℓ + X + γ . This can have important consequences for neutrino detection. We discuss observable consequences at high- and ultrahigh-energy neutrino telescopes and the Large Hadron Collider’s (LHC’s) Forward Physics Facility. Logarithmic enhancements can be substantial (e.g., ∼ 20 % ) when either the charged lepton’s energy or the rest of the cascade is measured. We comment on final state radiation’s impacts on measuring the inelasticity distribution, ν / ν ¯ flux ratio, throughgoing muons, and double-bang signatures for high-energy neutrino observation. Furthermore, for ultrahigh-energy neutrino observation, we find that final state radiation increases the overall detectable energy by as much as 20%, affects flavor measurements, and decreases the energy of both Earth-emergent tau leptons and regenerated tau neutrinos. Many of these have significant impacts on measuring neutrino fluxes and spectra. Finally, for the LHC’s Forward Physics Facility, we find that final state radiation will impact future extractions of strange quark parton distribution functions. Final state radiation should be included in future analyses at neutrino telescopes and the Forward Physics Facility. Published by the American Physical Society 2025

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Evaluating Radiation Impact on Transmon Qubits Using a Fast Decay Protocol in Above and Underground Laboratories

Superconducting qubits can be sensitive to sudden energy deposits caused by ambient radioactivity and cosmic rays. Previous studies have focused on understanding possible correlated effects over time and distance due to this radiation. In this study‚ for the first time‚ we directly compare the response of a transmon qubit measured initially at the SQMS above-ground facility (Fermilab‚ Illinois‚ USA) and then at the deep underground Gran Sasso Laboratory (INFN-LNGS‚ Italy). We observe the same average qubit lifetime of roughly 80 microseconds at both facilities. We then apply a fast decay detection protocol and investigate the time structure and relative rates of triggered events due to radiation versus intrinsic noise‚ comparing the above and underground performance of several high-coherence qubits. Using gamma sources of variable intensity we calibrate the response of the qubit to different levels of radiation in an environment with minimal background radiation. Results indicate that qubits respond to a strong gamma source‚ and it is possible to detect particle impacts. However‚ we do not observe a difference in radiation-induced-like events when comparing the above and underground results for niobium-based transmon qubits with sapphire substrates. We conclude that the majority of these events are not radiation-related and are attributed to other noise sources‚ which by far dominate single-qubit errors in modern transmon qubits. [1] Dominicis‚ Roy et al. arXiv:2405.18355

Roy, Tanay↗

Comparison of Modeled to Measured Spectra using MCNP and GADRAS to Benchmark and Contrast Modeling Limitations

The desire to improve nuclear material detection through portal monitors and other low resolution detectors has led to interest in benchmarking the performance of radiation transport codes. These codes can be used to generate a variety and quantity of spectra that may be cost prohibitive to measure directly. Particular characteristics of typical detection scenarios were isolated to compare the performance of radiation transport codes to laboratory experiments. These benchmark experiments were performed to validate simulations in a number of key areas. These experiments included high areal density configurations in both one- and three-dimensional configurations. In addition, off-angle measurements were conducted to investigate the impact of detector response assumptions on complex geometries, for example where an unknown source is not physically collocated with an apparent hot spot. Furthermore, by examining both simple shielding and backscatter configurations, isolation of the scatter emanating from the object and environmental background scatter contributions to the spectra could be elucidated. A series of experiments were performed in which the order of shielding layers and the thickness were evaluated to examine the ability of the simulations to address these variables. Experiments with increasing thickness of polyethylene around a neutron source also allows for examinations of the ability of the transport simulations to properly model n,γ reactions. Finally, depleted uranium (DU) measurements have more complicated spectra than the cobalt-60 and consequently allow for investigations into the ability of transport simulations to model self-shielding. In each case, the results of the experiments were compared to MCNP simulations to judge the performance of the code, as was done previously with GADRAS 18.7.9 simulations [7]. All of the benchmark measurements were taken with a liquid nitrogen cooled 140% high purity germanium (HPGe) detector with a bismuth collimator that had the front tin filter removed. The measurement location and detector configuration were subsequently used for all experimental configurations. The remainder of this report details the experimental measurements, Section 2 and the MCNP model, Section 3. Comparisons between the experimental results and MCNP-generated spectra are performed, Section 4. Section 5 compares the results obtained with MCNP with the previously reported results obtained with GADRAS [2]. Finally, Section 6 presents the conclusions.

61 RADIATION PROTECTION AND DOSIMETRY↗

Uranium Holdup Monitoring with Compton Imaging as Function of Depth and Mass

Material Control and Accountability (MC&A) programs track masses of materials flowing through production processes, where some material remains in process equipment as holdup. Quantification of these masses using gamma emissions typically involves usage of a well characterized radiation detector and assumptions of geometric configuration to constrain detection efficiencies, where the Generalized Geometry Holdup (GGH) method is often used. Uncertainties on the order of ±50% are observed, where the difficulties arise based on the asymmetric and gradient distributions of material that do not fall within the bounds of GGH. Gamma imagers provide a possible means to improve this geometric knowledge. This work describes the process used in creating a series of mass standards to aid the development of imaging algorithms for quantification.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Photoluminescence in Tagging: A Glowing Review

This literature review explores the options of using photoluminescence for tagging uranium fuel and zirconium cladding in order to easily and quickly associate interdicted material to its facility of origin or pathway after loss of institutional control. Photoluminescence is the spontaneous emission of radiation by a substance when excited by interaction with light. The source of photoluminescence can be from organic, inorganic, and organometallic compounds. Each luminophore, or compound responsible for luminescent properties, has individual strengths and weaknesses, depending on the intended use. Many factors can affect the brightness, lifetime, color, and detectability of luminophores, such as humidity, temperature, oxygen availability, noise from radiation–induced luminescence, and the presence of quenching substances like iron. Application of luminescent compound to the surface of an item can be done using paint, dye, thin film, thick film, or electrochemical coating. Several of the application techniques may have secondary functions such as corrosion resistance and detection, heat resistance, protective properties, and more. When considering cladding, there are various successful studies on the application of luminescent coatings on zirconium. However, significant research will be necessary to explore which luminophore and which application technique would best fit the intended use. In order to proceed with this research, a baseline of the natural luminescence of the intended base material (nuclear fuel or cladding) is necessary. While there may be issues with background noise, quenching from the environment, quenching from the substrate, signal to noise weakness, etc. the multitude of options may make photoluminescent tagging an option. In summary, this review has demonstrated that photoluminescence is a potential option to tag nuclear fuel and cladding, but additional paper–studies, testing, and research is required to understand the compatibility of luminescent tags in nuclear reactor environments, manufacturability, and detectability.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Abatement of ionizing radiation for superconducting quantum devices

Ionizing radiation has been shown to reduce the performance of superconducting quantum circuits. In this report, we evaluate the expected contributions of different sources of ambient radioactivity for typical superconducting qubit experiment platforms. Our assessment of radioactivity inside a typical cryostat highlights the importance of selecting appropriate materials for the experiment components nearest to qubit devices, such as packaging and electrical interconnects. We present a shallow underground facility (30-meter water equivalent) to reduce the flux of cosmic rays and a lead shielded cryostat to abate the naturally occurring radiogenic gamma-ray flux in the laboratory environment. We predict that superconducting qubit devices operated in this facility could experience a reduced rate of correlated multi-qubit errors by a factor of approximately 20 relative to the rate in a typical above-ground, unshielded facility. Finally, we outline overall design improvements that would be required to further reduce the residual ionizing radiation rate, down to the limit of current generation direct detection dark matter experiments.

47 OTHER INSTRUMENTATION↗