Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RESINS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Coupling of nitric acid digestion and anion-exchange resin separation for the determination of methylmercury isotopic composition within organisms

Isotope ratios of methylmercury (MeHg) within organisms can be used to identify sources of MeHg that have accumulated in food webs, but these isotopic compositions are masked in organisms at lower trophic levels by the presence of inorganic mercury (iHg). To facilitate measurement of MeHg isotope ratios in organisms, we developed a method of extracting and isolating MeHg from fsh and aquatic invertebrates for compound-specifc isotopic analysis involving nitric acid digestion, batch anion-exchange resin separation, and pre-concentration by purge and trap. Recovery of MeHg was quantifed after each step in the procedure, and the average cumulative recovery of MeHg was 93.4±2.9% (1 SD, n=28) for biological reference materials and natural biota samples and 96.9±1.8% (1 SD, n=5) for aqueous MeHgCl standards. The amount of iHg impurities was also quantifed after each step, and the average MeHg purity was 97.8±4.3% (1 SD, n=28) across all reference materials and natural biota samples after the fnal separation step. Measured MeHg isotopic compositions of reference materials agreed with literature values obtained using other MeHg separation techniques, and MeHg isotope ratios of aqueous standards, reference materials, and natural biota samples were reproducible. On average, the reproducibility associated with reference material process replicates (2 SD) was 0.10‰ for δ 202 MeHg and 0.04‰ for Δ 199 MeHg. This new method provides a streamlined, reliable technique that utilizes a single sample aliquot for MeHg concentration and isotopic analysis. Furthermore, this promotes a tight coupling between MeHg concentration, %MeHg, and Hg isotopic composition, which may be especially benefcial for studying complex food webs with multiple isotopically distinct sources of iHg and/or MeHg.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Changes in Normal Liver and Spleen Volume after Radioembolization with {sup 90}Y-Resin Microspheres in Metastatic Breast Cancer Patients: Findings and Clinical Significance

Purpose: In clinical trials with yttrium-90-resin-microspheres for the management of colorectal cancer liver metastases, it was observed that radioembolization might result in splenomegaly and an increase in portal vein size. Subclinical hepatitis in normal liver tissue as well as the effects of radioembolization and prior chemotherapy are suspected to be responsible for this phenomenon. The purpose of this study was to quantify the changes in liver and spleen volume and portal vein diameter after radioembolization. Methods: Twenty-seven patients with liver-dominant metastatic disease from breast cancer who had not responded to chemotherapy or had to abandon chemotherapy because of its toxic effects were evaluated. Changes in liver and spleen volume and portal vein diameter as well as liver tumor volume and diameter were quantified using computed tomography scans. Results: Radioembolization was associated with a significant mean decrease in the whole liver volume of 10.2% (median 16.7%; P = 0.0024), mainly caused by a reduction in the right lobe volume (mean 16.0%; P < 0.0001). These changes were accompanied by a significant increase in the diameter of the main portal vein (mean 6.8%; P < 0.0001) as well as splenic volume (mean 50.4%; P < 0.0001). Liver-tumor volume and diameter decreased by a median of 24 and 39.7%. Conclusions: Radioembolization is an effective treatment for tumor size reduction in patients with breast cancer liver metastases. Treatment is associated with changes of hepatic parenchymal volume, splenic volume, and portal vein size that appear not to represent clinically important sequelae in this patient cohort.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Yttrium-90 Resin Microsphere Radioembolization Using an Antireflux Catheter: An Alternative to Traditional Coil Embolization for Nontarget Protection

PurposeSerious complications can result from nontarget embolization during yttrium-90 (Y-90) transarterial radioembolization. Hepatoenteric artery coil embolization has been traditionally performed to prevent nontarget radioembolization. The U.S. Food and Drug Administration–approved Surefire Infusion System (SIS) catheter, designed to prevent reflux, is an alternative to coils. The hypothesis that quantifiable SIS procedural parameters are comparable to coil embolization was tested.MethodsFourteen patients aged 36–79 years with colorectal, neuroendocrine, hepatocellular, and other predominantly bilobar hepatic tumors who underwent resin microsphere Y-90 radioembolization using only the SIS catheter (n = 7) versus only detachable coils (n = 7) for nontarget protection were reviewed retrospectively. Procedure time, fluoroscopy time, contrast dose, radiation dose, and cost were evaluated.ResultsMultivariate analysis identified significant cohort differences in the procedural parameters evaluated (F(10, 3) = 10.39, p = 0.04). Between-group comparisons of the pretreatment planning procedure in the SIS catheter group compared to the coil embolization group demonstrated a significant reduction in procedure time (102.6 vs. 192.1 min, respectively, p = 0.0004), fluoroscopy time (14.3 vs. 49.7 min, respectively, p = 0.0016), and contrast material dose (mean dose of 174.3 vs. 265.0 mL, respectively, p = 0.0098). Procedural parameters were not significantly different between the two groups during subsequent dose delivery procedures. Overall cost of combined first-time radioembolization procedures was significantly less in the SIS group ($4252) compared to retrievable coil embolization ($11,123; p = 0.001).ConclusionThe SIS catheter results in a reduction in procedure time, fluoroscopy time, and contrast material dose and may be an attractive cost-effective alternative to detachable coil embolization for prevention of nontarget radioembolization.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison of Cone-Beam Tomography and Cross-Sectional Imaging for Volumetric and Dosimetric Calculations in Resin Yttrium-90 Radioembolization

PurposeTo compare the use of cone-beam computed tomography versus contrast-enhanced computed tomography (CT) and magnetic resonance imaging (MRI) in the calculation of liver volume and planned dose for yttrium-90 radioembolization.Materials and MethodsThe study retrospectively assessed 47 consecutive patients who underwent resin Y-90 radioembolization consecutively over a 2-year period at a single center. Volume calculation software was used to determine perfused lobar liver volumes from cone-beam CT (CBCT) images obtained during mapping angiography. CBCT-derived volumes were compared with perfused lobar volume derived from contrast-enhanced CT and MRI. Nominal activities as determined by the SIR-Spheres Microspheres Activity Calculator were similarly calculated and compared using both CBCT and conventionally acquired volumes.ResultsA total of 82 hepatic lobes were assessed in 47 patients. The mean percentage difference between combined CT-MRI- and CBCT-derived calculated lobar volumes was 25.3% (p = 0.994). The mean percentage difference in calculated dose between the two methods was 21.8 ± 24.6% (p = 0.42). Combined left and right lobar CT-derived dose difference was less than 10% in 22 lobes, between 10 and 25% in 20 lobes, between 25 and 50% in 13 lobes and greater than 50% in 5 lobes. Combined left and right lobar MRI-derived dose difference was less than 10% in 11 lobes, between 10 and 25% in 7 lobes, between 25 and 50% in 2 lobes and greater than 50% in 1 lobe.ConclusionsAlthough volume measurements derived from CT/MRI did not differ significantly from those derived from CBCT, variability between the two methods led to large and unexpected differences in calculated dose.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Characterization and Application of Superlig 620 Solid Phase Extraction Resin for Automated Process Monitoring of 90Sr

Characterization of SuperLig® 620 solid phase extraction resin was performed in order to develop an automated on-line process monitor for 90Sr. The main focus was on strontium separation from barium, with the goal of developing an automated separation process for 90Sr in high-level wastes. High-level waste contains significant 137Cs activity, of which 137mBa is of great concern as an interference to the quantification of strontium. In addition barium, yttrium and plutonium were studied as potential interferences to strontium uptake and detection. A number of complexants were studied in a series of batch Kd experiments, as SuperLig® 620 was not previously known to elute strontium in typical mineral acids. The optimal separation was found using a 2M nitric acid load solution with a strontium elution step of ~0.49M ammonium citrate and a barium elution step of ~1.8M ammonium citrate. 90Sr quantification of Hanford high-level tank waste was performed on a sequential injection analysis microfluidics system coupled to a flow-cell detector. The results of the on-line procedure are compared to standard radiochemical techniques in this paper.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Improving the recovery of Ba from Sr Resin columns using chelating agents

Age dating of Cs-137 sources necessitates the accurate and precise quantification of the isotope Ba-137. In previous efforts to determine the age of Cs-137 source material, variation in Ba recovery was the largest source of uncertainty. This work investigates the use of several common chelating agents (EDTA, CDTA, DTPA, and NTA) to strip barium from Sr Resin columns quantitatively in an effort to improve the reproducibility of the separation. Batch studies showed conditions in which CDTA, EDTA, and NTA may suppress the retention of Ba on the column. Follow-up column studies showed excellent removal of barium from the column with quantitative recovery in the appropriate elution fraction. Our report builds upon previous studies and establishes additional chelating agents that could be used in an age dating separation procedure

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Batch and column studies of radium, actinium, thorium and protactinium on CL resin in nitric acid, hydrochloric acid and hydrofluoric acid

CL resin (TrisKem International) was characterized for separations of radium, actinium, thorium and protactinium. Batch studies are presented for radium, actinium and thorium in HCl and HNO3 as well as for radium, thorium and protactinium in HF. The uptake of thorium from dilute HNO3 (≤ 10 -4 M) and dilute HCl (≤ 10 -4 M) was found to be very high (D w > 100 in HNO 3 and > 1000 in HCl). Kinetics studies on thorium were performed in HCl and HNO 3 to determine suitably for column separations. Six column separation studies are presented including the separation of trace thorium from radium and actinium in dilute HCl and HNO 3 , the separation of radium from 1 mg 232 Th in dilute HCl, the separation of thorium and radium in the presence of HCl and excess Cl-, the separation of radium, protactinium and thorium by retention of protactinium and the separation of protactinium and thorium by retention of thorium.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Separation of radium and actinium in acetic acid/acetate solutions using TK101 resin

Here, the uptake and elution behavior of Ra and Ac was studied on TK101 resin using acetic acid and acetate buffer (acetic acid/lithium acetate) solutions. There is high extraction of Ra (>10 3 ) over a wide range of acetic acid concentrations (0.02 to 4 M) with slightly lower extraction (>10 2 ) in the acetate buffer solutions (pH 3.9 to 5.6). The Ac extraction is considerably lower with a maximum D w of ∼100, and negligible extraction at high acetic acid concentrations (> 1 M) and in the acetate buffer solutions. The difference in D w can be leveraged for highly efficient separations of Ac from Ra, with no detectable Ra in the Ac fractions and high Ac yields (∼100%). These separations may be useful for radiopharmaceutical applications as the Ac purity is extremely high and the elution conditions can be optimized to be biologically safe and appropriate for chelation to molecules relevant to targeted alpha therapy.

and nuclear chemistry↗

Synthetic phenolic antioxidants, including butylated hydroxytoluene (BHT), in resin-based dental sealants

Resin-based dental sealants (also referred to as pit-and-fissure sealants) have been studied for their contribution to bisphenol A (BPA) exposure in children. Nevertheless, little attention has been paid to the occurrence of other potentially toxic chemicals in dental sealants. In this study, the occurrence of six synthetic phenolic antioxidants (SPAs), including 2,6-di-tert-butyl-4-hydroxytoluene (BHT), 2,6-di-tert-butyl-4-(hydroxyethyl)phenol (BHT-OH), 3,5-di-tert-butyl-4-hydroxy-benzaldehyde (BHT-CHO), 2,6-di-tert-butylcyclohexa-2,5-diene-1,4-dione (BHT-Q), 3,5-di-tert-butyl-4-hydroxybenzoic acid (BHT-COOH) and 2-tert-butyl-4-methoxyphenol (BHA), was examined in 63 dental sealant products purchased from the U.S. market. BHT was found in all dental sealants at median and maximum concentrations of 56.8 and 1020 µg/g, respectively. The metabolites of BHT and BHA were detected in 39–67% of samples, at concentration ranges of <LOQ to 242 µg/g. BHT is likely used in sealants to inhibit oxidative reactions, remove free radicals, and inhibit potential polymerization, which would eventually prolong the shelf-life of the products. The estimated daily intake (EDI) of BHT, following sealant placement, based on a worst-case scenario (application on eight teeth at 8 mg each tooth), was 930 and 6510 ng/kg bw/d for adults and children, respectively. The EDI of BHT from dental sealants was several orders of magnitude lower than the current acceptable daily intake (ADI) proposed by the European Food Safety Authority (EFSA). - Highlights: • Synthetic phenolic antioxidants (SPAs) were detected in dental sealants. • 2,6-di-tert-butyl-4-hydroxytoluene (BHT) concentration of up to 1020 µg/g was found. • Estimated daily intake of BHT after sealant placement was up to 9.52 µg/kg bw/d. • Daily intake of BHT through dental sealant application was below the acceptable daily intake.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Treatment Parameters and Outcome in 680 Treatments of Internal Radiation With Resin {sup 90}Y-Microspheres for Unresectable Hepatic Tumors

Purpose: Radioembolization (RE) using {sup 90}Y-microspheres is an effective and safe treatment for patients with unresectable liver malignancies. Radiation-induced liver disease (RILD) is rare after RE; however, greater understanding of radiation-related factors leading to serious liver toxicity is needed. Methods and Materials: Retrospective review of radiation parameters was performed. All data pertaining to demographics, tumor, radiation, and outcomes were analyzed for significance and dependencies to develop a predictive model for RILD. Toxicity was scored using the National Cancer Institute Common Toxicity Criteria Adverse Events Version 3.0 scale. Results: A total of 515 patients (287 men; 228 women) from 14 US and 2 EU centers underwent 680 separate RE treatments with resin {sup 90}Y-microspheres in 2003-2006. Multifactorial analyses identified factors related to toxicity, including activity (GBq) Selective Internal Radiation Therapy delivered (p < 0.0001), prescribed (GBq) activity (p < 0.0001), percentage of empiric activity (GBq) delivered (p < 0.0001), number of prior liver treatments (p < 0.0008), and medical center (p < 0.0001). The RILD was diagnosed in 28 of 680 treatments (4%), with 21 of 28 cases (75%) from one center, which used the empiric method. Conclusions: There was an association between the empiric method, percentage of calculated activity delivered to the patient, and the most severe toxicity, RILD. A predictive model for RILD is not yet possible given the large variance in these data.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Identification of c-Type Heme-Containing Peptides Using Non-Activated Immobilized Metal Affinity Cchromatography Resin Enrichment and Higher-Energy Collisional Dissociation

c-type cytochromes play essential roles in many biological activities of both prokaryotic and eukaryotic cells, including electron transfer, enzyme catalysis and induction of apoptosis. We report a novel enrichment strategy for identifying c-type heme-containing peptides that uses non-activated IMAC resin. The strategy demonstrated at least seven-fold enrichment for heme-containing peptides digested from a cytochrome c protein standard, and quantitative linear performance was also assessed for heme-containing peptide enrichment. Heme-containing peptides extracted from the periplasmic fraction of Shewanella oneidensis MR-1 were further identified using higher-energy collisional dissociation tandem mass spectrometry. The results demonstrated the applicability of this enrichment strategy to identify c-type heme-containing peptides from a highly complex biological sample, and at the same time, confirmed the periplasmic localization of heme-containing proteins during suboxic respiration activities of S. oneidensis MR-1.

59 BASIC BIOLOGICAL SCIENCES↗

Structural Dynamics in UV Curable Resins Resolved by In Situ 3D Printing X-ray Photon Correlation Spectroscopy

Additive manufacturing (AM) is a promising technique to rapidly produce polymeric materials into complex 3-dimensional (3D) geometries. While AM is widespread and relevant for a range of applications, implementation in industry has outpaced our fundamental understanding of polymer dynamics and structure development during the printing process. Characterization and quantification of such dynamics is necessary to optimize final material properties and design future materials and processes for 3D printing. Here, we utilize X-ray photon correlation spectroscopy (XPCS) to measure spatial and time-resolved, out-of-equilibrium dynamics during direct ink write (DIW) 3D printing. Specifically, we investigate the progression of structural dynamics in a dual cure (UV/thermal) nanocomposite during and directly after printing. As the filament is printed and cured in situ, the relaxation processes of the cross-linking network are measured through the dynamics of inorganic filler particles. The characteristic relaxation time of the dynamics is calculated through the intensity–intensity autocorrelation function g 2 and directly correlated to the printing process parameters, such as printhead velocity and UV light intensity. The time-resolved evolution of nanoscale dynamics follows a power-law dependence as the filament is cured. Additionally, bulk rheological characterizations reveal the macroscopic solidification of the resin, providing correlation of material properties across a wide range of length and time scales. Overall, the measurement of multiscale, out-of-equilibrium dynamics provides insight into the development of structure in polymer nanocomposite filaments during 3D printing and is used to further understand the influence of such parameters on the AM process.

36 MATERIALS SCIENCE↗

Thermomagnetic Processing of Liquid-Crystalline Epoxy Resins and Their Mechanical Characterization Using Nanoindentation

A thermomagnetic processing method was used to produce a biphenyl-based liquid-crystalline epoxy resin (LCER) with oriented liquid-crystalline (LC) domains. The orientation of the LCER was confirmed and quantified using two-dimensional X-ray diffraction. The effect of molecular alignment on the mechanical and thermomechanical properties of the LCER was investigated using nanoindentation and thermomechanical analysis, respectively. The effect of the orientation on the fracture behavior was also examined. Lastly, the results showed that macroscopic orientation of the LC domains was achieved, resulting in an epoxy network with an anisotropic modulus, hardness, creep behavior, and thermal expansion.

36 MATERIALS SCIENCE↗

Epoxy resin reinforced with nanothin polydopamine-coated carbon nanotubes: a study of the interfacial polymer layer thickness

Carbon nanotubes (CNTs) functionalized by a nanothin poly(dopamine) (PDA) layer were produced by a one-pot, nondestructive approach, with direct polymerization of dopamine on the CNT surface. The thickness of the PDA layer can be well-controlled by the reaction time and the proportion of dopamine, and this thickness is found to be the key factor in controlling the dispersion of CNTs and the extent of the interfacial interactions between the CNT@PDA and epoxy resin. SEM results indicated that the dispersion of CNTs in epoxy was improved significantly by coating a nanothin PDA layer onto the CNT surface. In agreeme nt with this finding, the CNTs functionalized with the thinnest PDA layer provided the best mechanical and thermal properties. This result confirmed that a thinner PDA layer could provide optimized interfacial interactions between the CNT@PDA and epoxy matrix and weaken the self-agglomeration of CNTs, which led to an improved effective stress and heat transfer between the CNTs and the polymer matrix.

36 MATERIALS SCIENCE↗

Photoinitiation study of Irgacure 784 in an epoxy resin photopolymer

A deeper understanding of the processes, which occur during free radical photopolymerization, is necessary in order to develop a fully comprehensive model, which represents their behavior during exposure. One of these processes is photoinitiation, whereby a photon is absorbed by a photosensitizer producing free radicals, which can initiate polymerization. These free radicals can also participate in polymer chain termination (primary termination), and it is therefore necessary to understand their generation in order to predict the temporally varying kinetic effects present during holographic grating formation. In this paper, a study of the photoinitiation mechanisms of Irgacure 784 photosensitizer, in an epoxy resin matrix, is presented. We report our experimental results and present a theoretical model to predict the physically observed behavior.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Contribution To Degradation Study, Behavior Of Unsaturated Polyester Resin Under Neutron Irradiation

Applications of unsaturated polyester thermosetting resins are numerous in construction sector, in transport, electric spare parts manufactures, consumer goods, and anticorrosive materials. This survey reports the effect of thermosetting polymer degradation (unsaturated polyester): degradation by neutrons irradiation. In order to evaluate the deterioration of our material, some comparative characterizations have been done between standard samples and damaged ones. Scanning electron microscopy (SEM), ultrasonic scanning, hardness test (Shore D) are the techniques which have been used. The exposure to a neutrons flux is carried out in the column of the nuclear research reactor of Draria (Algiers-Algeria). The energetic profile of the incidental fluxes is constituted of fast neutrons (PHI{sub R} = 3.10{sup 12} n.cm{sup -2}.s{sup -1}, E = 2 Mev) of thermal neutrons (PHI{sub TH} = 10{sup 13} n.cm{sup -2}.s{sup -1}; E = 0.025 ev) and epithermal neutrons (PHI{sub epi} = 7.10{sup 11} n.cm{sup -2}.s{sup -1}; E>4,9 ev). The received dose flow is 0,4 Kgy. We notice only a few scientific investigations can be found in this field. In comparison with the standard sample (no exposed) it is shown that the damage degree is an increasing process with the exposure. Concerning the description of irradiation effects on polymers, we can advance that several reactions are in competition: reticulation, chain break, and oxidation by radical mechanism. In our case the incidental particle of high energy fast neutrons whose energy is greater or equal to 2 Mev, is braked by the target with a nuclear shock during which the incidental particle transmits a part of its energy to an atom. If the energy transfer is sufficient, the nuclear shock permits to drive out an atom of its site the latter will return positioning interstitially, the energy that we used oversteps probably the energy threshold (displacement energy). This fast neutrons collision with target cores proceeds to an indirect ionization by the preliminary creation of excited secondary species that will generate ionization. Scanning electron microscopy (SEM) performed with an acceleration tension of 0,7 kV shows clearly the caused damage. This observation seems to indicate the presence of major chain breaks for the sample bombarded during 90 minutes. Let us note that the presence of benzenic cores improves behavior toward radiations indeed the chemical function recognized as the most stable to radiations is the aromatic ring. In order to value the rigidity of our material we have determined the Young's modulus . The values are 7.17, 7.60, 8.39 and 8.96 Gpa respectively for blank samples, 30, 60 and 90 minutes exposure ones. Thus, we remark an increase of Young's modulus that can be interpreted in terms of reticulation, provided to use the level of irradiation dose.

36 MATERIALS SCIENCE↗

FISSION NEUTRON IRRADIATION EFFECT ON INTERLAMINAR SHEAR STRENGTH OF CYANATE ESTER RESIN GFRP AT RT AND 77 K

A glass fiber reinforced plastic (GFRP) with cyanate ester resin was fabricated and neutron irradiation tests up to 1x10{sup 22} n/m{sup 2} of fast neutron with over 0.1 MeV energy were carried out in fission reactor. The fabrication process of cyanate ester GFRP was established and a collaboration network to perform investigations on irradiation effect of superconducting magnet materials was constructed. Three kinds of samples were fabricated. The first was CTD403 GFRP made by NIFS, the second was (cyanate ester+epoxy) GFRP provided by Toshiba, and the last was CTD403 GFRP made by Toshiba. The irradiation was carried out at JRR-3 in Japan Atomic Energy Agency using Rabbit capsules.After the irradiation, short beam tests were conducted at room temperature and 77 K and interlaminar shear strength (ILSS) was evaluated. The irradiation of 1x10{sup 21} n/m{sup 2} increased ILSS a little but 1x10{sup 22} n/m{sup 2} irradiation decreased ILSS to around 50 MPa. These tendencies were observed in all three kinds of GFRPs.

36 MATERIALS SCIENCE↗

Modeling the Residual Stresses in Reactive Resins-Based Materials: a Case Study of Photo-Sensitive Composites for Dental Applications

Residual stresses in reactive resins-based composites are associated to the net volumetric contraction (shrinkage) arising during the cross-linking reactions. Depending on the restoration geometry (the ratio of the free surface area to the volume of the cavity) the frozen-in stresses can be as high as the strength of the dental composites. This is the main reason why the effectiveness and then the durability of restorations with composites remains quite lower than those realized with metal alloys based materials. In this paper we first explore the possibility to circumvent the mathematical complexity arising from the determination of residual stresses in reactive systems three-dimensionally constrained. Then, the results of our modeling approach are applied to a series of commercially available composites showing that almost all samples develop residual stresses such that the restoration undergoes failure as soon as it is realized.

36 MATERIALS SCIENCE↗