SOLID CRYOGENIC REFRIGERATION OF SPACECRAFT COMPONENTS
Design of a refrigeration system based on the sublimation of a solid cryogenic material for critical spacecraft components
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Design of a refrigeration system based on the sublimation of a solid cryogenic material for critical spacecraft components
Operation of a cavity-type maser in a closed-cycle helium refrigerator
Minimum noise, low temperature, cooled parametric amplifier with simulated closed-cycle refrigerator system
Practical Philips cycle for low temperature refrigeration, noting equal coefficient of performance to that of ideal Carnot cycle under isothermal conditions
Pulse tube and cryomatic gas balancing cryogenic refrigeration methods
One-watt refrigerator used for attaining clean room conditions in vacuum system of space simulator
Design evaluation of vapor absorbing refrigerator systems operating independently of gravity
JPL has long been involved with developing cryogenic refrigeration systems for the cooling of.
The Jet Propulsion Laboratory (JPL) has been involved in cryogenic refrigeration development for.
The Soft X-ray Spectrometer instrument on the Astro-H observatory contains a 6x6 array of x-ray microcalorimeters that is cooled to 50 mK by an adiabatic demagnetization refrigerator (ADR). The ADR consists of three stages in order to provide stable detector cooling using either a 1.2 K superfluid helium bath or a 4.5 K Joule-Thomson (JT) cryocooler as its heat sink. When liquid helium is present, two of the ADR's stages are used to single-shot cool the detectors while rejecting heat to the helium. After the helium is depleted, all three stages are used to continuously cool the helium tank (to about 1.5 K) and single-shot cool the detectors (to 50 mK), using the JT cryocooler as its heat sink. The Astro-H observatory, renamed Hitomi after its successful launch in February 2016, carried approximately 36 liters of helium into orbit. On day 5, the helium had cooled sufficiently (<1.4 K) to allow operation of the ADR. This paper describes the design, operation and on-orbit performance of the ADR, and the use of the ADR's heat rejection as a tool for mass gauging the helium tank.
The cryogenics and fluids branch at NASA Goddard Space Flight Center is currently developing a flight-worthy vibration-free 50 mK to 10 K Continous Adiabatic Demagnetization Refrigerator (CADR) that will potentially serve as the cooling scheme for future space flight missions such as OST, LUVOIR, and other flagship missions. This 7 stage CADR will lift 6 microW of heat at its lowest stage and reject heat to a temperature platform at 10 K. A single stage 4 - 10 K flight-worthy ADR unit was recently demonstrated with an optimized cycle time of 132 seconds and a heat lift of ~13 mW at 4 K. We discuss the development progress and details of its desing in this presentation.
Thermoelectric cooling, reversed Brayton cycles and Stirling cycle devices are common cooling technologies employed on spacecraft where temperatures below the radiator temperature are needed. Although used less often in microgravity, vapor compression refrigeration was proposed for microgravity applications as early as the 1970s. Researchers proposed the vapor compression cycle over other cooling technologies for its superior energy efficiency in the typical refrigerator/freezer and air-conditioning temperature range. The higher energy efficiency should alleviate the mass penalty of the thermal system, conceivably both for satellites and manned spacecraft. Despite numerous propositions, the literature lacks a discussion of the absolute equivalent mass benefit achievable and the value of it relative to the total mass of the thermal system of the spacecraft or the spacecraft itself. This paper presents the equivalent mass benefits of employing a vapor compression system over other cooling technologies using a mass penalty factor for power consumption. Additionally, a prototype vapor compression cooler sized to fit into an ISS locker is presented.
Vitalij Pecharsky, distinguished professor of materials science and engineering, discusses his research in magnetic refrigeration at Ames Lab.
Variable Refrigerant Flow (VRF) heat pumps are often regarded as energy efficient air-conditioning systems which offer electricity savings as well as reduction in peak electric demand while providing improved individual zone setpoint control. One of the key advantages of VRF systems is minimal duct losses which provide significant reduction in energy use and duct space. However, there is limited data available to show their actual performance in the field. Since VRF systems are increasingly gaining market share in the US, it is highly desirable to have more actual field performance data of these systems. An effort was made in this direction to monitor VRF system performance over an extended period of time in a US national lab test facility. Due to increasing demand by the energy modeling community, an empirical model to simulate VRF systems was implemented in the building simulation program EnergyPlus. This paper presents the comparison of energy consumption as measured in the national lab and as predicted by the program. For increased accuracy in the comparison, a customized weather file was created by using measured outdoor temperature and relative humidity at the test facility. Other inputs to the model included building construction, VRF system model based on lab measured performance, occupancy of the building, lighting/plug loads, and thermostat set-points etc. Infiltration model inputs were adjusted in the beginning to tune the computer model and then subsequent field measurements were compared to the simulation results. Differences between the computer model results and actual field measurements are discussed. The computer generated VRF performance closely resembled the field measurements.
This information sheet provides details about saving energy through proper refrigerant charge.
A technology specification factsheet on LED lighting for refrigerated display cases.
This case study highlights a new technology called a high rotor pole switched reluctance (HRSR) motor that can help grocers improve the efficiency of their refrigeration systems.
To bridge the existing gap in modeling the variable refrigerant flow heat pump systems with heat recovery (VRFHR), we developed a suite of dynamic VRFHR system models in Modelica. These models are specifically tailored for residential multi-functional VRFHR (MF-VRFHR) applications, including space conditioning and domestic hot water (DHW) heating, utilizing both the TIL library for HVAC equipment and the Buildings library for thermal load calculations. The development comprises essential component models, including the newly developed heat recovery unit (HRU), along with system models that integrate the heat pump system and building envelope. These system models accommodate various operational modes such as heating-only, cooling-only, and heating-recovery (including heating-dominant and cooling-dominant) modes. Furthermore, we propose an efficient optimization-based model calibration method that identifies critical model parameters while utilizing a small amount of data obtained from either real systems or manufacturer's specifications. We demonstrate the effectiveness of these models and the proposed calibration method for a MF-VRFHR system installed in Richland, WA. The developed models are calibrated and validated using data collected under different operational modes during both heating and cooling seasons. The results show that the models capture the system dynamics and achieve high accuracy, with the coefficient of the variation of the root-mean-square-error less than 15% for variables such as outdoor unit power consumption, compressor speed, space temperature and DHW temperature. The validated models serve as a reliable representation of the MF-VRFHR system, facilitating the development and validation of optimized controls needed to realize the full benefits of integrated heat pump systems. Future research will utilize these models to develop advanced controls and optimize system performance for improved energy efficiency and demand flexibility.