Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “REAGENTS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Colorometric detection of ethylene glycol vapor

Very low concentrations of ethylene glycol in air or other gases are detected by passing a sample through a glass tube with three partitioned compartments containing reagents which successively convert the ethylene glycol vapor into a colored compound.

Helm, C.↗

Nondestructive spot tests allow rapid identification of metals

Ordered qualitative test sequence, presented in flow chart form, permits identification of all common metallurgical elements and many high-temperature, stainless, high and low carbon, and tool steels within about 30 minutes. Identification is made from colors or specific reactions produced by the addition of standard chemical reagents.

Wilson, M. L.↗

Energy and chemical reaction. I

Reagent translational energy effect on dynamics of ionic and atomic reactions, using nuclear recoil and chemical accelerator methods

Wolfgang, R.↗

Nonequilibrium processes

Nonequilibrium processes, discussing chemical reactions between electronically, vibrationally, rotationally and translationally excited reagents

Polanyi, J. C.↗

Prototype Slide Stainer

The prototype slide staining system capable of performing both one-component Wright's staining of blood smears and eight-step Gram staining of heat fixed slides of microorganisms is described. Attention was given to liquid containment, waste handling, absence of contamination from previous staining, and stability of the staining reagents. The unit is self-contained, capable of independent operation under one- or zero-g conditions, and compatible with Skylab A.

Source record↗

A simple spectrophotometric method for determination of zirconium or hafnium in selected molybdenum-base alloys

A simple analytical procedure is described for accurately and precisely determining the zirconium or hafnium content of molybdenum-base alloys. The procedure is based on the reaction of the reagent Arsenazo III with zirconium or hafnium in strong hydrochloric acid solution. The colored complexes of zirconium or hafnium are formed in the presence of molybdenum. Titanium or rhenium in the alloy have no adverse effect on the zirconium or hafnium complex at the following levels in the selected aliquot: Mo, 10 mg; Re, 10 mg; Ti, 1 mg. The spectrophotometric measurement of the zirconium or hafnium complex is accomplished without prior separation with a relative standard deviation of 1.3 to 2.7 percent.

Dupraw, W. A.↗

Development of a tape transport bacterial detection system

The feasibility of a tape transport chemiluminescence system for bacterial monitoring of regenerated water was demonstrated using a manually operated laboratory breadboard. The principle of detection is based on measuring the increase in chemiluminescence produced by the catalytic action of bacterial porphyrins on a luminol-hydrogen peroxide mixture. Viable organisms are distinguished from nonviable by comparing the signals of incubated and unincubated water samples. Using optimized protocols, sensitivities were obtained with 400 ml suspensions of E. coli and Cl. sporogenes. The sensitivity of the unincubated cycle E. coli (aerobe) was found to be 30 to 35 cells/m1, and that of the Cl. sporogenes (anaerobe) was 1000 to 10,000 cells/m1. The lower sensitivity toward Cl. sporogenes is attributed to several factors, namely the lower cytochrome content, the tendency to sporulate, long lag periods and the lower growth rate of Clostridia in general. The operational procedures used for processing the incubated and unincubated samples involved the following sequence: (1) concentrating the sample by filtration through a membrane filter, (2) washing with Dextrose-Thioglycollate Broth (3) incubating (0 to 4 hrs as required), (4) washing with 4M Urea, and (5) reacting with reagent in front of a photomultiplier tube. The signal output was recorded on a strip chart recorder.

Witz, S.↗

Energy distribution among reaction products. V.

Discussion of three reactions, one point of theoretical interest being the predicted correlation between barrier height and barrier location. The H + Br 2 reaction having a lower activation barrier than H + Cl 2, should have an earlier barrier, and hence a greater percentage attractive energy release and higher efficiency of vibrational excitation. Information is developed concerning the effect of isotopic substitution in the pair of reactions H + Cl 2 and D + Cl 2. The 'arrested relaxation' method was used. Essentially, the method involves reacting two diffuse reagent beams in a reaction vessel with background pressure less than 0.001 torr, and with walls cooled by liquid nitrogen or liquid helium.

Anlauf, K. G.↗

Reusable silica surface-insulation material

Material was specifically developed for manufacture of insulating tiles, but it can be molded into other shapes as required. Basic raw materials are high-purity silica fiber, fumed-silica powder, and reagent-grade starch. Only purest materials are used, and care must be taken to avoid contamination during processing.

Goldstein, H. E.↗

Time exposure studies on stress corrosion cracking of aluminum 2014-T6, aluminum 7075-T651, and titanium 6Al-4V

The effect of a constant applied stress in crack initiation of aluminum 2014-T6, 7075-T651 and titanium 6A1-4V has been investigated. Aluminum c-ring specimens (1-inch diameter) and u-band titanium samples were exposed continuously to a 3.5% NaCl solution (pH 6) and organic fluids of ethyl, methyl, and iso-propyl alcohol (reagent purity). Corrosive action was observed to begin during the first and second day of constant exposure as evidenced by accumulation of hydrogen bubbles on the surface of stressed aluminum samples. However, a similar observation was not noted for titanium stressed specimens. Results of this investigation seems to suggest that aluminum 2014-T6, aluminum 7075-T651 are susceptible to stress corrosion cracking in chloride solution (NaCl); while they (both alloys) seem to resist stress corrosion cracking in methyl alcohol, ethyl alcohol, iso-propyl alcohol, and demineralized distilled water. Titanium 6A1-4V showed some evidence of susceptibility to SCC in methanol, while no such susceptibility was exhibited in ethanol, iso-propyl alcohol and demineralized distilled water.

Terrell, J.↗

Time exposure studies on stress corrosion cracking of aluminum 2014-T6, 2219-T87, 2014-T651, 7075-T651, and titanium 6Al-4V

The effect of a constant applied stress in crack initiation of aluminum 2014-T6, 2219-T87, 2014-T651, 7075-T651 and titanium 6Al-4V has been investigated. Aluminum c-ring specimens (1-inch diameter) and u-band titanium samples were exposed continuously to a 3.5% NaCl solution (pH 7) and organic fluids of ethyl, methyl, and iso-propyl alcohol (reagent purity), and demineralized distilled water. Corrosive action was observed to begin during the first and second day of constant exposure as evidenced by accumulation of hydrogen bubbles on the surface of stressed aluminum samples. However, titanium stressed specimens showed no reactions to its environment. Results of this investigation seems to suggest that aluminum 2014-T6, aluminum 7075-T651 and aluminum 2014-T651 are susceptible to stress corrosion cracking in chloride solution (NaCl), while aluminum 2219-T87 seem to resist stress corrosion cracking in sodium chloride at three levels of stress (25%, 50%, and 75% Y.S.). In organic fluids of methyl, ethyl, and iso-propyl alcohol, 2014-T6 and 7075-T651 did not fail by SCC; but 2014-T651 was susceptible to SCC in methly alcohol, but resistant in ethyl alcohol, iso-propyl alcohol and demineralized distilled water.

Terrell, J.↗

Automatic instrument for chemical processing to detect microorganism in biological samples by measuring light reactions

An automated apparatus is reported for sequentially assaying urine samples for the presence of bacterial adenosine triphosphate (ATP) that comprises a rotary table which carries a plurality of sample containing vials and automatically dispenses fluid reagents into the vials preparatory to injecting a light producing luciferase-luciferin mixture into the samples. The device automatically measures the light produced in each urine sample by a bioluminescence reaction of the free bacterial adenosine triphosphate with the luciferase-luciferin mixture. The light measured is proportional to the concentration of bacterial adenosine triphosphate which, in turn, is proportional to the number of bacteria present in the respective urine sample.

Kelbaugh, B. N.↗