Survival After Chemoradiation in Resected Pancreatic Cancer: The Impact of Adjuvant Gemcitabine

Purpose: To evaluate survival in patients with resected pancreatic cancer treated with concurrent chemoradiation with or without adjuvant gemcitabine (Gem). Methods and Materials: From 1998 to 2010, 86 patients with pancreatic adenocarcinoma who underwent resection were treated with adjuvant concurrent chemoradiation. Thirty-four patients received concurrent 5-fluorouracil-based chemoradiation (5-FU/RT) with traditional field radiation (range, 45-61.2 Gy; median, 50.4 Gy) without further adjuvant therapy. Thirty patients received traditional field 5-FU/RT (range, 45-60.4 Gy; median, 50.4 Gy) with Gem (1,000 mg/m{sup 2} weekly) either before and after radiotherapy or only after radiotherapy. Twenty-two patients received concurrent full-dose Gem (1,000 mg/m{sup 2} weekly)-based chemoradiation (Gem/RT), consisting of involved-field radiation (range, 27-38 Gy; median, 36 Gy) followed by further adjuvant Gem. Results: The median age of the cohort was 65 years (range, 40-80 years). Of the patients, 58 had T3 tumors (67%), 22 had T2 tumors (26%), and 6 had T1 tumors (7%). N1 disease was present in 61 patients (71%), whereas 18 patients (21%) had R1 resections. Performance status, lymph node status, and margin status were all similar among the treatment groups. Median follow-up was 19.0 months. Median overall survival (OS) (19.2 months, 19.0 months, and 21.0 months) and 3-year OS rates (26.5%, 27.2%, and 32.1%) were similar among patients with 5-FU/RT with no adjuvant Gem, those with 5-FU/RT with adjuvant Gem, and those with Gem/RT with adjuvant Gem, respectively (p = 0.88). Patients who received adjuvant Gem had a similar median OS (22.1 months) and 3-year OS rate (29%) compared to patients who did not (19.2 months and 26.5%, respectively) (p = 0.62). There was a trend for improved 3-year OS rates in patients with R0 vs. R1 resections (28.1% vs. 14.2%, p = 0.06) and in patients with T1 and T2 vs. T3 tumors (38% vs. 20%, p = 0.09). Node-negative patients had an improved 3-year OS rate (30.1%) when compared with patients with N1 disease (16.2%) (p = 0.02). Conclusion: In our cohort of patients with resected pancreatic cancer, Gem chemotherapy did not improve OS after chemoradiotherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Biological effects of cosmic radiation: deterministic and stochastic

Our basic understanding of the biological responses to cosmic radiations comes in large part from an international series of ground-based laboratory studies, where accelerators have provided the source of representative charged particle radiations. Most of the experimental studies have been performed using acute exposures to a single radiation type at relatively high doses and dose rates. However, most exposures in flight occur from low doses of mixed radiation fields at low-dose rates. This paper provides a brief overview of existing pertinent clinical and biological radiation data and the limitations associated with data available from specific components of the radiation fields in airflight and space travel.

Flight Experiment↗

Thermodynamic limits to the efficiency of solar energy conversion by quantum devices

The second law of thermodynamics imposes a strict limitation to the energy converted from direct solar radiation to useful work by a quantum device. This limitation requires that the amount of energy converted to useful work (energy in any form other than heat) can be no greater than the change in free energy of the radiation fields. Futhermore, in any real energy conversion device, not all of this available free energy in the radiation field can be converted to work because of basic limitations inherent in the device itself. A thermodynamic analysis of solar energy conversion by a completely general prototypical quantum device is presented. This device is completely described by two parameters, its operating temperature T sub R and the energy threshold of its absorption spectrum. An expression for the maximum thermodynamic efficiency of a quantum solar converter was derived in terms of these two parameters and the incident radiation spectrum. Efficiency curves for assumed solar spectral irradiance corresponding to air mass zero and air mass 1.5 are presented.

Buoncristiani, A. M.↗

Accuracy of Analog Fiber-Optic Links in Pulsed Radiation Environments

Interferometric fiber-optic links used in pulsed-power experiments are evaluated for accuracy in the presence of radiation fields which alter fiber transmission. Amplitude-modulated format (e.g., Mach-Zehnder) and phase-modulated formats are compared. Historically, studies of radiation effects on optical fibers have focused on degradation and recovery of the fibers transmission properties; such work is either in the context of survivability of fibers in catastrophic conditions or suitability of fibers installed for command and control systems within an experimental facility [1], [2]. In this work, we consider links used to transmit realtime diagnostic data, and we analyze the error introduced by radiation effects during the drive pulse. The result is increased uncertainties in key parameters required to unfold the sinusoidal transfer function. Two types of modulation are considered: amplitude modulation typical of a Mach-Zehnder (M-Z) modulator [3], and phase modulation, which offers more flexible demodulation options but relies on the spatiotemporal coherence of the light in the fiber. The M-Z link is shown schematically in Fig. 1, and the phase-modulated link is shown in Fig. 2. We present data from two experimental environments: one with intense, controlled radiation fields to simulate conditions expected at the next generation of pulsed-power facilities, and the second with radiation effects below the noise level of the recording system. In the first case, we intentionally expose three types of single-mode fiber (SMF) to ionizing radiation and study the response by simultaneously monitoring phase and amplitude of the transmitted light. The phase and amplitude effects are evidently dominated by different physical phenomena, as their recovery dynamics are markedly different; both effects, though, show similar short-term behavior during exposure, integrating the dose at the dose levels studied, from 1 to 300 kRad, over the exposure times of 50 ps and 30 ns. In the second case, we present data using a state-of-the-art fiber-optic link for single-shot transmission and recording, fielded at the OMEGA laser facility on high-yield fusion experiments. Gamma reaction history data are measured with a gas Cherenkov detector (GCD) [4], [5] and transmitted by M-Z link to a 12 GHz digitizer. Since radiation effects on the fibers are not above the noise floor, the error analysis for the unfolded data is dominated by the performance of the fast digitizer, the photoreceiver, and the laser.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Compton interaction of free electrons with intense low frequency radiation

Electron behavior in an intense low frequency radiation field, with induced Compton scattering as the primary mechanism of interaction, is investigated. Evolution of the electron energy spectrum is studied, and the equilibrium spectrum of relativistic electrons in a radiation field with high brightness temperature is found. The induced radiation pressure and heating rate of an electron gas are calculated. The direction of the induced pressure depends on the radiation spectrum. The form of spectrum, under the induced force can accelerate electrons to superrelativistic energies is found.

Illarionov, A. F.↗

Interpolation And FFT Of Near-Field Antenna Measurements

Bivariate Lagrange interpolation applied to plane-polar measurement scans. Report discusses recent advances in application of fast-Fourier-transform (FFT) techniques to measurements of near radiation fields of antennas on plane-polar grid. Attention focused mainly on use of such measurements to calculate far radiation fields. Also discussion of use of FFT's in holographic diagnosis of distortions of antenna reflectors. Advantage of scheme, it speeds calculations because it requires fewer data and manipulations of data than other schemes used for this purpose.

Gatti, Mark S.↗

Effect of laser frequency on a collision-induced radiative process

A review is presented of the principles of collision induced radiative processes, followed by an examination of the effects of laser frequencies on these processes. A one-dimensional problem involving two electron states is considered, and it is found that the Hamiltonian of the radiation field is dominated by electric-dipole interaction which couples states of different parity. Transitions are noted to be dependent on collisions, and the complexities of three-dimensional systems are expressed as considerations of the angular momentum of the photon, the necessity of treating different states simultaneously, and the fact that a radiation field destroys rotational invariance. Changing the radiation frequency alters the crossing point and offers opportunities to study the interplay of potential surfaces with molecular dynamics. Experiments on Na+A systems are outlined for several collision energies and various laser frequencies. Multiple crossings were obtained, although the total cross-section, at all energies, decreased at 18,350/cm.

Devries, P. L.↗

Real-time verification of multileaf collimator-driven radiotherapy using a novel optical attenuation-based fluence monitor

Purpose: Multileaf collimator (MLC)-driven conformal radiotherapy modalities [e.g., such as intensity-modulated radiotherapy (IMRT), intensity-modulated arc therapy, and stereotactic body radiotherapy] are more subject to delivery errors and dose calculation inaccuracies than standard modalities. Fluence monitoring during treatment delivery could reduce such errors by allowing an independent interface to quantify and assess measured difference between the delivered and planned treatment administration. We developed an optical attenuation-based detector to monitor fluence for the on-line quality control of radiotherapy delivery. The purpose of the current study was to develop the theoretical background of the invention and to evaluate the detector's performance both statistically and in clinical situations. Methods: We aligned 60 27-cm scintillating fibers coupled to a photodetector via clear optical fibers in the direction of motion of each of the 60 leaf pairs of a 120 leaves Millenium MLC on a Varian Clinac iX. We developed a theoretical model to predict the intensity of light collected on each side of the scintillating fibers when placed under radiation fields of varying sizes, intensities, and positions. The model showed that both the central position of the radiation field on the fiber (x{sub c}) and the integral fluence passing through the fiber ({Phi}{sub int}) could be assessed independently in a single measurement. We evaluated the performance of the prototype by (1) measuring the intrinsic variation of the measured values of x{sub c} and {Phi}{sub int}, (2) measuring the impact on the measured values of x{sub c} and {Phi}{sub int} of random leaf positioning errors introduced into IMRT fields, and (3) comparing the predicted values of x{sub c} and {Phi}{sub int} calculated with the treatment planning software to the measured values of x{sub c} and {Phi}{sub int} in order to assess the predictive effectiveness of the developed theoretical model. Results: We observed a very low intrinsic dispersion, dominated by Poisson statistics, for both x{sub c} (standard deviations of less than 1 mm) and {Phi}{sub int} (standard deviations of less than 0.20%). When confronted with random leaf positioning errors from IMRT segments, {Phi}{sub int} was highly sensitive to single leaf positioning errors as small as 1 mm at isocenter, while x{sub c} was sensitive to leaf pair translation errors of at least 2 mm at isocenter. Owing to the uncertainties in the doses calculated in regions of high perpendicular dose gradients, the measured values of x{sub c} and {Phi}{sub int} deviated from the predicted values of x{sub c} and {Phi}{sub int} by a mean of 1.3 mm and 2.6%, respectively. Conclusion: Our study showed that an optical attenuation-based detector can be used to effectively monitor integral fluence during radiotherapy delivery. The performance of such a system would enable real-time quality control of the incident fluence in current MLC-driven treatments such as IMRT and future adaptive radiotherapy procedures where new treatment plans will have to be delivered without passing thru the current standard quality control chain.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Mid-Infrared Spectrum of the Galactic Center: A Starburst Nucleus

Using the Michelson interferometer on the Midcourse Space Experiment (MSX), we have taken spectra of many positions in the central 25 min of the Galactic Center (GC) with a 6 min x 9 min FOV. The spectral coverage was 380 to 1700/ cm (6 to 26 microns) and the resolution was approx. 21/cm. The spectra exhibit strong UIR/PAH features at 6.2, 7.7, 8.6 and 11.3 microns, in addition to the ionic lines of (Ne II), at 12.8 microns, (S III) 18.7 microns, and (Ar II) 6.98 microns. There are deep silicate absorption features at 10 and 18 microns and a cold continuum increasing at the longest wavelengths. Additional weak features are present in the spectra. We discuss the variation in the extinction at 10 microns as a function of location in the GC. Compared to the MSX spectrum of the Orion nebula, smoothed to the same resolution and multiplied by the estimated GC extinction, the GC spectra have similar PAH features, but the Orion Nebula also has strong lines of (He III) 15.6 microns, (S IV) 10.5 microns, and (Ar III) 8.99 microns and its 25 microns continuum is stronger (colder). Thus, the GC exhibits the mid-IR spectrum of a low excitation H II region and a nearby molecular cloud with a surface photodissociation region (PDR). This is in excellent agreement with the canonical model of a starburst nucleus in which the hot stars and molecular clouds are randomly distributed. The outer surfaces of the clouds are photodissociated and ionized by the photons from the stars located outside the clouds. The PAH molecules are transiently heated by the stellar photons. Since the exciting stars are located well outside the clouds, the radiation field is dilute compared to a newly-formed blister H II region like Orion; this dilute radiation field causes the relatively low excitation of the ionic lines.

Simpson, J. P.↗

Far-Field Pattern Measurement and Simulation of VHF Antenna at 60 MHz for Europa Clipper Mission

This paper presents measurements and simulations of a linearly polarized VHF folded dipole operating at 60 MHz for NASA’s upcoming Europa Clipper mission. The spacecraft contains a ground penetrating radar, consisting of an array of four VHF antennas, that will characterize the surface of Jupiter’s icy moon Europa. Measured far-field radiation patterns and reflection coefficients above a 50×80m perfect ground plane are compared to predicted results using commercial software. Normalized Far-Field radiation pattern cuts are measured utilizing a biconical antenna and receiver mounted on a flying drone. Simulations of the radiation pattern show that the number of lobes increases with the distance of the antenna from the ground due to the ground-bounce phenomenon. In addition, the measured and simulated reflection coefficients stay unchanged for height above 2 meters, which matches the predicted calculation of the reactive-near field region of this antenna. However, the antenna electrical parameters are optimized for use on the spacecraft and become detuned in the presence of a ground plane. Simulated and measured return loss discrepancy less than 0.5 dB is presented. Radiation pattern comparisons show similar agreement when taking into account the effect of far-field measurement uncertainties.

Decrossas, Emmanuel↗

On the detection of a stochastic background of gravitational radiation by the Doppler tracking of spacecraft

Consideration is given to the possibility of detection of an isotropic background gravitational radiation of a stochastic nature by the method of Doppler tracking of spacecraft. Attention is given in the geometrical optics limit, to the general formula for the frequency shift of an electromagnetic signal in the gravitational radiation field, and it is shown to be gauge independent. The propagation of a free electromagnetic wave in a gravitational radiation field is examined with the conclusion that no resonance phenomena can be expected. Finally, the 'Doppler noise' due to a stochastic background is evaluated, and it is shown to depend on the total energy density of the background and a parameter that is a characteristic of the radiation spectrum and the detection system used.

Mashhoon, B.↗

BOBCAT Personal Radiation Detector Field Test and Evaluation Campaign

Following the success of the Anole test of portable detection system, the U.S. Department of Homeland Security (DHS) Domestic Nuclear Detection Office organized a test and evaluation campaign for personal radiation detectors (PRDs), also known as “Pagers.” This test, “Bobcat,” was conducted from July 17 to August 8, 2006, at the Nevada Test Site. The Bobcat test was designed to evaluate the performance of PRDs under various operational scenarios, such as pedestrian surveying, mobile surveying, cargo container screening, and pedestrian chokepoint monitoring. Under these testing scenarios, many operational characteristics of the PRDs, such as gamma and neutron sensitivities, positive detection and false alarm rates, response delay times, minimum detectable activities, and source localization errors, were analyzed. This paper will present the design, execution, and methodologies used to test this equipment for the DHS.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Magnetic fields and radiative shocks in protogalaxies and the origin of globular clusters

The paper examines the hypothesis that globular clusters formed from gravitational instability in dense sheets of gas produced behind radiative shocks inside protogalaxies, such as those produced by the collision of subgalactic mass fragments partaking of the virial motions within the protogalaxy, in order to determine the differences which result if a magnetic field is present in the preshock medium. The MHD conservation equations are solved along with rate equations for nonequilibrium ionization, recombination, molecular formation and dissociation, and the equations of radiative transfer for steady-state shocks of velocity 300 km/s in a gas of preshock densities of 0.1-1 cu cm, and magnetic field strengths of 0.1-6 micro-G. The magnetic field is found to limit the degree of postshock compression and, thereby, to reduce the level of external radiation flux required to suppress H2 formation and cooling.

Shapiro, Paul R.↗

MAJOR-MERGER GALAXY PAIRS AT Z = 0: DUST PROPERTIES AND COMPANION MORPHOLOGY

We present an analysis of dust properties of a sample of close major-merger galaxy pairs selected by K {sub s} magnitude and redshift. The pairs represent the two populations of spiral–spiral (S+S) and mixed morphology spiral–elliptical (S+E). The Code Investigating GALaxy Emission software is used to fit dust models to the Two Micron All Sky Survey, Wide-Field Infrared Survey Explorer , and Herschel flux density measurements, and to derive the parameters describing the polycyclic aromatic hydrocarbons contribution, interstellar radiation field, and photodissociation regions. Model fits verify our previous Spitzer Space Telescope analysis that S+S and S+E pairs do not have the same level of enhancement of star formation and differ in dust composition. The spirals of mixed-morphology galaxy pairs do not exhibit the enhancements in interstellar radiation field and therefore dust temperature for spirals in S+S pairs in contrast to what would be expected according to standard models of gas redistribution due to encounter torques. This suggests the importance of the companion environment/morphology in determining the dust properties of a spiral galaxy in a close major-merger pair.

79 ASTRONOMY AND ASTROPHYSICS↗

Classical and quantum description of a periodically driven multi-photon anharmonic oscillator

The Hamiltonian and hence the relevant equations of motion involving the dynamics of a driven classical anharmonic oscillator of 2m-th anaharmonicity are constructed. In order to derive the model of a driven multi-photon quantum anharmonic oscillator, we neglect the non-conserving energy terms. Assuming the periodical nature of the driven/forcing term, the dynamical nature of the field operators are expressed in terms of the coupling constant, excitation/photon number and the driven parameters. The solutions are found useful for investigating the squeezing effects and the antibunching of photons of the radiation field prepared in the initial thermal/Fock states. The squeezing effects of the radiation field is found impossible. However, a clear signature of the antibunching of photons is exhibited. It corroborates the fact that the presence of one nonclassical phenomenon does not warrant the presence of the second one. The solutions presented here are exact analytical in nature. Nevertheless, a detailed investigation on the driven quantum anharmonic oscillator is not done before. The present investigation will be of fundamental importance.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Position sensitive detection of neutrons in high radiation background field

We present the development of a high-resolution position sensitive device for detection of slow neutrons in the environment of extremely high γ and e{sup −} radiation background. We make use of a planar silicon pixelated (pixel size: 55 × 55 μm{sup 2}) spectroscopic Timepix detector adapted for neutron detection utilizing very thin {sup 10}B converter placed onto detector surface. We demonstrate that electromagnetic radiation background can be discriminated from the neutron signal utilizing the fact that each particle type produces characteristic ionization tracks in the pixelated detector. Particular tracks can be distinguished by their 2D shape (in the detector plane) and spectroscopic response using single event analysis. A Cd sheet served as thermal neutron stopper as well as intensive source of gamma rays and energetic electrons. Highly efficient discrimination was successful even at very low neutron to electromagnetic background ratio about 10{sup −4}.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Gyrosynchrotron radiation and its transfer in a magnetoactive plasma.

Gyrosynchrotron radiation fields from mildly relativistic electrons in a magnetoactive plasma are asymptotically calculated by using the Green tensor and the Fourier transformation. These fields consist of the two components which correspond to the ordinary and extraordinary modes. Taking into account these fields, the emissivities and the absorption coefficients from an arbitrary distribution of electrons are calculated in order to discuss the intensity, spectrum, and polarization of gyrosynchrotron radiation. In general, the transfer of electromagnetic energy takes place along a direction different from that of the wave normal since the radiation fields have a nonvanishing component along the direction of the wave normal. A consideration is given on the problem of radiative transfer in relation to the Stokes parameters.

Sakurai, K.↗

Path Toward a Unifid Geometry for Radiation Transport

The Direct Accelerated Geometry for Radiation Analysis and Design (DAGRAD) element of the RadWorks Project under Advanced Exploration Systems (AES) within the Space Technology Mission Directorate (STMD) of NASA will enable new designs and concepts of operation for radiation risk assessment, mitigation and protection. This element is designed to produce a solution that will allow NASA to calculate the transport of space radiation through complex computer-aided design (CAD) models using the state-of-the-art analytic and Monte Carlo radiation transport codes. Due to the inherent hazard of astronaut and spacecraft exposure to ionizing radiation in low-Earth orbit (LEO) or in deep space, risk analyses must be performed for all crew vehicles and habitats. Incorporating these analyses into the design process can minimize the mass needed solely for radiation protection. Transport of the radiation fields as they pass through shielding and body materials can be simulated using Monte Carlo techniques or described by the Boltzmann equation, which is obtained by balancing changes in particle fluxes as they traverse a small volume of material with the gains and losses caused by atomic and nuclear collisions. Deterministic codes that solve the Boltzmann transport equation, such as HZETRN [high charge and energy transport code developed by NASA Langley Research Center (LaRC)], are generally computationally faster than Monte Carlo codes such as FLUKA, GEANT4, MCNP(X) or PHITS; however, they are currently limited to transport in one dimension, which poorly represents the secondary light ion and neutron radiation fields. NASA currently uses HZETRN space radiation transport software, both because it is computationally efficient and because proven methods have been developed for using this software to analyze complex geometries. Although Monte Carlo codes describe the relevant physics in a fully three-dimensional manner, their computational costs have thus far prevented their widespread use for analysis of complex CAD models, leading to the creation and maintenance of toolkit-specific simplistic geometry models. The work presented here builds on the Direct Accelerated Geometry Monte Carlo (DAGMC) toolkit developed for use with the Monte Carlo N-Particle (MCNP) transport code. The workflow for achieving radiation transport on CAD models using MCNP and FLUKA has been demonstrated and the results of analyses on realistic spacecraft/habitats will be presented. Future work is planned that will further automate this process and enable the use of multiple radiation transport codes on identical geometry models imported from CAD. This effort will enhance the modeling tools used by NASA to accurately evaluate the astronaut space radiation risk and accurately determine the protection provided by as-designed exploration mission vehicles and habitats