Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Quadrupole”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Non-resonant picosecond three-wave mixing in the gas phase

We report on the experimental observation of non-resonant, second-order optical sum-frequency generation (SFG) in five different atomic and molecular gases. The measured signal is attributed to a SFG process by characterizing its intensity scaling and its polarization behavior. We show that the electric quadrupole mechanism cannot explain the observed trends and suggest a mechanism based on symmetry breaking along the incident beam path arising from laser-induced species ground state number density gradients. Our results demonstrate that the SFG is about four orders of magnitude stronger than the third-harmonic generation (THG) and independent from any externally applied electric fields. In conclusion, these features make this method suitable for gas number density measurements at the picosecond time scale in reactive flows and plasmas.

LaCombe, Grayson↗

High-temperature and high-pressure NMR investigations of low viscous fluids confined in mesoporous systems

Abstract In this contribution, the relaxation and diffusional behaviors of low viscous fluids, water and methanol confined into mesoporous silica and controlled size pore glass were investigated. The engineered porous systems are relevant to geologically important subsurface energy materials. The engineered porous proxies were characterized by Brunauer–Emmett–Teller (BET) surface analyzer, nuclear magnetic resonance (NMR) spectroscopy, and electron microscopy (EM) to determine surface area, pore-wall protonation and morphology of these materials, respectively. The confined behavior of the low viscous fluids was studied by varying pore diameter, fluid-to-solid ratio, temperature, and pressure, and then compared to bulk liquid state. Both relaxation and diffusion behaviors for the confined fluids showed increasing deviation from pure bulk fluids as the fluid-to-solid ratio was decreased, and surface-to-volume ratio ( S / V ) was varied. Variable pressure deuteron NMR relaxation of confined D 2 O and confined methanol, deuterated at the hydroxyl or methyl positions, were performed to exploit the sensitivity of the deuteron quadrupole moment to molecular rotation. The methanol results demonstrated greater pressure dependence than those for water only in bulk. The deviations from bulk liquid behavior arise from different reasons such as confinement and the interactions between confined fluid and the nano-pore wall. The results of the present report give insight into the behavior of low viscosity fluid in nano-confined geometries under different state conditions.

Chemistry↗

Cation Data for the East River Watershed, Colorado (2014-2025)

This data package contains mean values for cation concentration for water samples taken from the East River Watershed in Colorado. Inductively coupled plasma mass spectrometry (ICP-MS) has been used to measure the concentrations of elements of interest simultaneously for the East River Watershed, Colorado groundwater and surface water samples to inform insights on the biogeochemistry processes within the watershed. The East River is part of the Watershed Function Scientific Focus Area (WFSFA) located in the Upper Colorado River Basin, United States. For samples collected prior to 06-16-2021, the instrumentation, Elan DRC II, PerkinElmer SCIEX, automatically switches among the three models necessary to analyze all 37 elements. These 37 elements include: (1) Lithium (Li), Beryllium (Be), Boron (B), Sodium (Na), Magnesium (Mg), Aluminium (Al), Silicon (Si), Phosphorus (P), Titanium (Ti), Cobalt (Co), Nickel (Ni), Copper (Cu), Zinc (Zn), Germanium (Ge), Arsenic (As), Rubidium (Rb), Strontium (Sr), Zirconium (Zr), Molybdenum (Mo), Silver (Ag), Cadmium (Cd), Tin (Sn), Antimony (Sb), Caesium (Cs), Barium (Ba), Europium (Eu), Lead (Pb), Thorium (Th), Uranium (U) using standard model, argon Ar as reaction gas, (2) Potassium (K), Calcium (Ca), Vanadium (V), Chromium (Cr), Manganese (Mn), Iron (Fe) using dynamic reaction cell (DRC) model, ammonia NH3 as reaction gas, and (3) Phosphorus (P) and Selenium (Se) using DRC model, oxygen O2 as reaction gas. Note for the samples with higher concentrations of chloride (Cl-), asenic (As) concentrations were analysed with DRC model (oxygen O2 as reaction gas) to avoid the interference of chloride. For samples collected on and after 06-16-2021, an advanced Agilent 8900 triple quadrupole inductively coupled plasma mass spectrometry system (Agilent 8900 QQQ ICP-MS, Agilent Technologies) has been used to measure the concentrations of interested 36 elements simultaneously for environmental samples, including (1) Lithium (Li), Beryllium (Be) and Boron (B) using standard no gas mode, (2) Sodium (Na), Magnesium (Mg), Aluminium (Al) Phosphorus (P), Potassium (K), Chromium (Cr), Manganese (Mn), Iron (Fe), Cobalt (Co), Nickel (Ni), Copper (Cu), Zinc (Zn), Germanium (Ge), Arsenic (As), Rubidium (Rb), Strontium (Sr), Zirconium (Zr), Molybdenum (Mo), Silver (Ag), Cadmium (Cd), Tin (Sn), Antimony (Sb), Cesium (Cs), Barium (Ba), Europium (Eu), Lead (Pb), Thorium (Th) and Uranium (U) using standard helium (He) collision mode, (3) Titanium (Ti) and Vanadium (V) using high Energy (HEHe) helium (He) collision mode, and (4) Silicon (Si), Calcium (Ca) and Selenium (Se) using standard H2 reaction mode. All samples were prepared/diluted with 2% (v/v) ultrapure nitric acid in Milli-Q water (18.2 mega ohm-cm), and analyzed under a rigorous quality assurance and quality control (QA/QC) process. This data package contains (1) a zip file (cation_data_2014_2025.zip) containing a total of 5,849 files: 5.848 data files of cation data from across the Lawrence Berkeley National Laboratory (LBNL) Watershed Function Scientific Focus Area (SFA) which is reported in .csv files per location and a locations.csv (1 file) with latitude and longitude for each location; (2) a file-level metadata (v6_20260901_flmd.csv) file that lists each file contained in the dataset with associated metadata; (3) a data dictionary (v6_20260901_dd.csv) file that contains terms/column_headers used throughout the files along with a definition, units, and data type; (4) PDF and docx files for the detemination of Method Detection Limits (MDLs) for ICP-MS PerkinElmer DRC II instrumentation (Detemination_of_Method_Detection_Limits__MDLs__for_ICP_MS__PerkinElmer_Elan_DRC_II__LBL_Bldg74_Lab214D) for samples before November 2021; (5) PDF and docx files for the determination of MDLs for ICP-MS Agilent 8900 QQQ instrumentation (ICP_MS_Analysis_detection_limits_and_QA_QC_WenmingDong_updated_2026-08-06) for samples November 2021 and onward. Missing values within the anion data files are noted as either "-9999" or "0.0" for not detectable (N.D.) data. There are a total of 113 locations containing cation data. Update on 2021-04-11: Added Detemination of Method Detection Limits (MDLs) for ICP-MS document, which can be accessed as a PDF or with Microsoft Word. Update on 2022-06-10: versioned updates to this dataset was made along with these changes: (1) updated cation data for all locations up to 2021-12-31, (2) removal of units from column headers in datafiles, (3) added row underneath headers to contain units of variables, (4) removed suffix and prefix on two variables (“aqberylliumion_asberyllium” and “aqlithiumion_aslithium”), (5) added -9999 for empty numerical cells, and (6) the addition of the file-level metadata (flmd.csv) and data dictionary (dd.csv) were added to comply with the File-Level Metadata Reporting Format. Update on 2022-09-09: Updates were made to reporting format specific files (file-level metadata and data dictionary) to correct swapped file names, add additional details on metadata descriptions on both files, add a header_row column to enable parsing, and add version number and date to file names (v2_20220909_flmd.csv and v2_20220909_dd.csv). Update on 2023-08-08: Updates were made to both the data files and reporting format specific files. New available anion data was added, up until 2023-01-05. The file level metadata and data dictionary files were updated to reflect the additional data added. Update on 2024-03-11: Updates were made to both the data files and reporting format specific files. New available anion data was added, up until 2023-10-16. Further, revisions to the data files were made to remove incorrect data points (from 1970 and 2001). The reporting format specific files were updated to reflect the additional data added. Updated versions of the PDF and docx files for determination of MDLs for ICP-MS data were added to this dataset for samples starting in November 2021. Update on 2025-05-15: Updates were made to both the data files and reporting format specific files. New available cation data was added, up until the end of WY2024 (September 30, 2024). International Generic Sample Numbers (IGSNs), when registered, were added to the data files. The reporting format specific files were updated to reflect the additional data added. Update on 2026-09-01: Updates were made to both the data files and reporting format specific files. New available cation data was added, up until the end of WY2025 (September 30, 2025). Updated versions, as of 2026-08-06, of the PDF and docx files for determination of MDLs for ICP-MS data were added to this dataset for samples starting in November 2021.

54 ENVIRONMENTAL SCIENCES↗

Surface water geochemistry along St. Louis River Estuary (Duluth/Superior, MN/WI)

This dataset is aimed at understanding changes in surface water chemistry associated with urbanization in the Great Lakes region. Surface water chemistry including cations, anions, organic and inorganic carbon, and nitrogen were collected from six locations along St. Louis River – a freshwater estuary entering Lake Superior (Duluth/Superior, MN/WI). The Duluth/Superior, MN/WI metropolitan area is the largest port on the United States side of Lake Superior. Samples were collected near different land uses every two weeks from late July 2023 to the onset of ice cover in November 2023. Water samples were analyzed using In-Situ AquaTroll 500 Multiparameter Sonde with Ammonium Ion Selective Electrode and Chlorophyll-a sensor (unfiltered), METTLER TOLEDO FiveEasy Plus FP20 and METTLER TOLEDO LE407 probe (unfiltered); HACH DR300 Pocket Colorimeter Iron FerroVer (filtered 0.22 μm in field); Shimadzu TOC-L Total Organic Carbon Analyzer with TNM-L Total Nitrogen Unit (filtered 0.22 μm in field); Agilent 8900 triple quadrupole ICP-MS (ICP-QQQ) (filtered 0.22 μm in field); and Dionex ICS-6000 HPIC System (filtered 0.22 μm in field).The data package is comprised of 5 files. dd.csv contains the description of columns in Geochemistry_LSNERR_water.csv and Sampling_sites.csv. flmd.csv contains descriptions of each file in the dataset. README.txt contains description of the dataset structure and file content. Geochemistry_LSNERR_water.csv contains geochemistry data for six sampling locations along the St. Louis River. Sampling_sites.csv contains latitude and longitude coordinates for each of the six sampling site locations along the St. Louis River.This data has not been previously published.

54 ENVIRONMENTAL SCIENCES↗

Multiple Synchrotron Light Monitors for Transverse Matching and Monitoring at CEBAF

Beam setup at the Continuous Electron Beam Accelerator Facility (CEBAF) involves threading beam through the machine and monitoring global transfer functions to identify and address cumulative lattice errors. Transverse beam emittance may grow by as much as two orders of magnitude, mediated by synchrotron radiation. Re-matching the enlarged beam phase space into successive re-circulation arcs minimizes this emittance growth but requires knowledge of the actual beam distribution. This is now accomplished through quadrupole scans using wire profile monitors, the most time-consuming activity in our setup process. We propose to use Synchrotron Light Monitors (SLMs) to image the beam at homologous points in the four super-period recirculation arc lattices. Benefits include real-time monitoring of beam parameters and reduced elapsed time for initial setup.These SLMs will be installed in Arc 7 of the CEBAF machine, where Synchrotron Radiation contributes moderately to emittance growth. One of four required SLMs will be installed and commissioned this year, with the rest being installed next year.

Freeman, B.↗

Three Approaches for Complete Measurement of the Transverse Beam Optics Along the Fermilab Muon Campus Extraction Line

Traditionally, the process of measuring the optical parameters of a beamline has employed the use of one of two standard methods, namely the three-screen method or a quadrupole magnet scan. Both require either an area of zero dispersion to perform the measurements or knowledge of the dispersion function and momentum spread beforehand in order to provide accurate results. There is however a third method that can be used to measure the standard optical parameters, the beam parameters, the dispersion function, and the momentum spread simultaneously. This method, aptly named the six-screen method, is an extension of the more standard three-screen method. Utilizing the simulation environment of G4beamline, we simulated the 8 GeV proton beam in the M4 beamline and measured the optical and beam parameters using the two standard approaches. Those results were then used as a reference to check the viability of employing the less standard six-screen method in the M4 line. If shown to be a viable option, the six-screen method could be used to retrieve the dispersion function and momentum spread of the beam without needing to change the energy of the beam.

43 PARTICLE ACCELERATORS↗

Multibunch Studies for LCLS-II High Energy Upgrade

The Linac Coherent Light Source (LCLS) X-ray free-electron laser at SLAC is being upgraded to LCLS-II with a superconducting linac and 1 MHz bunch repetition rate. The proposed high-energy upgrade (LCLS-II-HE) will increase the beam energy from 4 to 8 GeV, extending the reach of accessible X-ray photon energies. With the increased repetition rate and longer linac of LCLS-II-HE, multi-bunch effects are of greater concern. We use recently introduced capabilities in the beam transport code ELEGANT to study dipole and monopole beam breakup effects for LCLS-II HE beam parameters. The results indicate that resonant dipole kicks have steady-state settle times on the order of 500 bunches or less and appear manageable. We also consider a statistical variation of the cavity frequencies and transverse offsets of cavities and quadrupoles. Resonant emittance growth driven by monopole kicks is found to be disrupted by frequency variation between cavities.

43 PARTICLE ACCELERATORS↗

Lattice Design of the Beam Transfer Line (BTL) from PIP-II LINAC to the Booster at Fermilab

PIP-II beam transfer line (BTL) to transport the beam from PIP-II Linac to the Booster ring at Fermilab. The latest design eliminates rolling the dipoles in the beam line to cross over the Tevatron tunnel. Also re-designed is the lattice in the region of the Booster Injection to meet the request of the civil construction needs and accommodate the constrains of the Booster injection request. A beam line to the beam absorber (BAL) is designed based on the request from the results of Mars simulations and ANASYS calculation of the absorber. Simulations with dipole and quadrupole field errors for the Beam Transport Line (BTL) to the Booster, which provides the specifications for all the magnets and Power supplies, will be presented too.

43 PARTICLE ACCELERATORS↗

Computational simulations and beamline optimizations for an electron beam degrader at CEBAF

An electron beam degrader is under development with the objective of measuring the transverse and longitudinal acceptance of the Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Lab. This project is in support of the CE+BAF positron capability. Computational simulations of beam-target interactions and particle tracking were performed integrating the GEANT4 and Elegant toolkits. A solenoid was added to the setup to control the beam's divergence. Parameter optimization of the solenoid field and magnetic quadrupoles gradient was also performed to further reduce particle loss through the rest of the injector beamline.

Lizárraga-Rubio, V.↗

RESONANT MATCHING SECTION FOR CEBAF ENERGY UPGRADE

Thomas Jefferson National Accelerator Facility (Jeffer- son Lab) currently studies the feasibility of upgrading its energy to 22 GeV. It considers addition of six more linac passes. The highest energy passes will share two new arcs designed using the Fixed-Field Alternating Gradient (FFA) technology. The FFA arcs are built using permanent combined-function magnets. They will be connected to the linacs through transition sections that will match the optics of all six passes to the linacs. With the high number of con- straints and the limited space available, we are investigating a parametric resonance technique to match the optics quasi- independently at each energy. A resonance is excited at each individual energy to selectively control its optics. The reso- nant dipole and quadrupole kick harmonics are imposed for all energies simultaneously using Panofsky corrector mag- nets placed throughout the FFA arcs. This paper presents the current progress on that transition section design

Deitrick, K.↗

SINGLE BUNCH TRACKING ON THE TEN-PASS ER@CEBAF ENERGY RECOVERY BEAMLINE

The proposed ten-pass energy recovery linac (ERL) demonstration (five accelerating, five decelerating) at the CEBAF accelerator, ER@CEBAF, involves a multi-GeV en- ergy range of a continuous electron beam. New CEBAF transverse optics were designed for this ERL demonstration. This redesign incorporates additional components in Arc A, including a path length chicane and new quadrupoles to ensure proper dispersion localization. The new five energy recovery passes with a shared arc transport scheme chal- lenge the overall beamline optics design, including large beta functions in the CEBAF spreaders and recombiners. Here we discuss results of bunch tracking performed using the elegant tracking code for the full ER@CEBAF beamline

Neththikumara, I.↗

Progress on the normal conducting magnets for the Electron-Ion Collider

The electron-ion collider (EIC) at Brookhaven National Laboratory (BNL) is designed to deliver a peak luminosity of 1e+34 1/cm2 1/sec. The EIC will take advantage of the existing Relativistic Heavy Ion Collider (RHIC) facility. Two additional rings will be installed: an electron storage ring (ESR) and a rapid cycling electron synchrotron ring (RCS).This paper presents an update on the normal conducting magnet designs required for both the ESR and RCS rings. The ESR will store polarized electron beams up to 18 GeV and utilizes a triplet of dipole magnets to increase the emittance at 5 GeV and generate excess bending to create additional radiation damping to allow a larger beam-beam tune shift. The RCS will accelerate single bunches of spin-polarized electrons at various energies from 5 GeV to 18 GeV, with a ramp rate of 100 ms and 1 Hz repetition rate. Both rings require dipole, quadrupole and sextupole magnets with different specifications.

43 PARTICLE ACCELERATORS↗

Chromaticity compensation of a ghost collider

The GHOST collider final focus system is a pure quadrupole-drift beamline targeting ¿* = 2 mm at four serial interaction points, with peak ¿-functions reaching ~65 km in the final triplet. Beam tracking simulations reveal that a nominal bunch develops a pronounced C-shape in longitu- dinal phase space at IP1, with ¿¿ growing from 0.15 mm to ~2.3 mm — a factor of ~15× increase that directly re- duces luminosity. The mechanism is identified as chromat- ically amplified betatron path length: off-momentum par- ticles acquire enlarged betatron amplitudes in the high-¿ final triplet, generating excess path length via the geometric ¿¿ = - 1/2 ¿ (¿'2 + ¿'2) ¿¿ integral. Within the monoenergetic Balandin framework, ¿2¿2 with ¿ = - 1/2 ¿ ¿ ¿¿ dominates ¿2¿2 by over four million times; the full beam ¿¿ is a fur- ther factor of ~27 larger, driven by ¿¿ -induced chromatic amplitude growth. Phase-advance scans confirm that ¿¿ is insensitive to the apochromatic (¿ ˜ 0) condition. When combined with the geometric hourglass effect, this distor- tion poses a challenge to maximizing luminosity within the current lattice design.

Gamage, B. [Thomas Jefferson National Accelerator ↗

ORBIT CORRECTION STUDIES ON THE ELECTRON TRANSPORT LINE FROM RCS TO ESR

A dedicated electron transfer line from Rapid Cycling Synchrotron (RCS) to Electron Storage Ring (ESR), referred to as the RTE line has been designed for the Electron-Ion Collider (EIC). The beamline follows a straight-line geometry, with a length of 133 m, and is consists with two matching sections and a FODO section for beam diagnostics. Imperfections with magnet alignments introduce orbit distortions, making orbit correction scheme a critical component in the design. To facilitate orbit correction, each quadrupole magnet is equipped with a pair of beam position monitors (BPMs) and kickers. The Singular Value Decomposition (SVD) algorithm is used for orbit correction and tolerance studies. This paper presents the ongoing progress in the optics design and error correction scheme of the RTE line.

Neththikumara, I. [Thomas Jefferson National Accel↗

A New Magnetic Measurement System for the Future Low Emittance NSLS-II Storage Ring

A new magnetic measurement system is under construc-tion at BNL for accurate field harmonic measurements and fiducialization of magnets for a future upgrade of the NSLS- II storage ring. The entire storage ring is envi-sioned to be replaced with a new lattice concept, known as Complex Bend, which superimposes dipole and high-gradient quadrupole fields. The magnetic measurement system will use rotating wire and a PCB rotating coil specifically designed for small-aperture (< 15 mm) high gradient magnets. In this paper we describe in detail the mechanical design and the data acquisition hardware and software.

43 PARTICLE ACCELERATORS↗

Transverse Stability in an Alternating Symmetry Planar Dielectric Wakefield Structure

Dielectric Wakefield Acceleration (DWA) is a promising technique for realizing the next generation of linear colliders. It provides access to significantly higher accelerating gradients than traditional radio-frequency cavities. One impediment to realizing a DWA-powered accelerator is the issue of the transverse stability of the beams within the dielectric structure due to short-range wakefields. These short-range wakefields have a tendency to induce a phenomenon known as single-bunch beam breakup, which acts as its name implies and destroys the relevant beam. We attempt to solve this issue by leveraging the quadrupole mode excited in a planar dielectric structure and then alternating the orientation of said structure to turn an unstable system into a stable one. We examine this issue computationally to determine the limits of stability and based on those simulations describe a future experimental realization of this strategy.

43 PARTICLE ACCELERATORS↗

A New PCB Rotating Coil at NSLS-II

Several R&D projects are underway at NSLS-II towards an upgrade of its storage ring with a new lattice that will use high field magnets with small bores of 16-22 mm. A large fraction of the high field magnets are expected to be of permanent magnet technology that will require precise magnetic measurements and field harmonics corrections. A new magnetic measurement bench has been built based on a printed circuit board (PCB) coil of 12 mm diameter and 270 mm active length. This PCB coil has the capabil-ity of measuring field quality to a level of 10 ppm of the main field up to the 15th harmonic with a sensitivity between 0.01 m2 and 0.02 m2 at the reference radius of 5 mm. This paper will describe the main features of the rotating coil bench and discuss the measurement results of a permanent-magnet Halbach quadrupole of 12.7 mm bore diameter.

43 PARTICLE ACCELERATORS↗

FPGA-Based Spill Regulation System for the Muon Delivery Ring at Fermilab

The Muon to Electron Experiment (Mu2e) requires a uniform beam profile from the Muon Delivery Ring to meet their experimental needs. A specialized Spill Regulation System (SRS) has been developed to help achieve consistent spill uniformity. The system is based on a custom-designed carrier board featuring an Arria 10 SoC, capable of executing real-time feedback control. The FPGA processes beam pulses of approximately 200 ns every 1.695 $μ$s, allowing for continuous monitoring of the extracted spill intensity through fast bunch integration. The system directly controls three quadrupole magnets, which work in conjunction with sextupole magnets to achieve third-order resonant extraction. Furthermore, the board interfaces with Fermilab's Accelerator Control Network (ACNET), enabling operators to modify spill regulation settings in real-time via the control network while providing diagnostic waveforms. These waveforms help operators monitor the process and fine-tune the feedback mechanisms. This paper presents an overview of the board's architecture and its initial progress toward regulating beam extraction. This initial version of the regulation system aims to evaluate baseline performance to inform future system improvements.

Berlioz, J. R. [Fermilab]↗