Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Power Tower”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Global Energy and Aviation Concerns

Renewable energy sources are usually diffuse and require large facilities. Biofuels work better, are more economical to produce for ground transportation, but sharply increase competition for food croplands. Noble laureate Richard Smalley (deceased-2005) conceptual 20 TWe power generation covers hundreds x hundreds of miles. Combined with Fuller s superconducting power grid system would enable renewable planetary energy. A solar-wind project in Australia will have a 7km diameter collector interfacing with a 1 km tower to extract 200 MW from wind turbines mounted at the base. GE Energy s 3.5MW Wind Turbine is large and placing this in perspective, it is as if one were rotating a Boeing 747-200; the blade diameter is that large. Wind turbines are rapidly gaining popularity in Europe and photovoltaic (PV) is expected to also expand rapidly. It becomes clear that we need (and still have time) to develop new sources of energy. Hf 178 bombarded by X-rays produces Gamma-rays for heating. The reaction stops when the X-rays stop; the half life is about 30 years and seems manageable vs 30 000 years. Water splitting needs to be perused as do ultra fast ultra intense laser applications in terms of fusion and new materials developments including new ways to strip and re-bind hydrogen into fuels. New methods and tools for development are being found in quantum mechanical applications to macro-systems and need to be developed into a set of new tool boxes for development of these new energy sources.

Hendricks, Robert C.↗

Coupled loads analysis of a novel shared-mooring floating wind farm

Shared mooring lines are a method to reduce the stationkeeping cost of floating offshore wind farms; however, their impacts on floating array dynamics are not yet well understood. Here this article presents advancements to floating wind farm simulation capabilities that allow the dynamic modeling of shared-mooring floating wind arrays - specifically, platform coupling through shared lines and proper phasing of wave loads across the array. These capabilities are demonstrated on a 10-turbine shared-mooring array featuring two staggered rows of wind turbines. A baseline array design with individually moored turbines is used as a basis for comparison. Coupled analysis using FAST.Farm shows that the shared-mooring design has smaller fluctuations in surge when compared to the baseline design. The mean and maximum platform offsets are highest in normal operating conditions, but the maximum mooring line tensions are highest in 50-year storm conditions. Power spectral density analysis of platform surge and sway motions shows that the shared mooring configuration does not introduce any significant inter-platform resonances. The tower-base bending moment statistics and the line tension damage equivalent loads indicate no consequential differences in turbine loading or mooring fatigue life. Anchor load analysis shows that the total required anchor capacity for the shared-mooring array is decreased by approximately 25% when shared anchors are used. Dynamic simulations of the shared mooring system under line failures show that remaining line tensions stay within bounds and that offsets are significantly smaller when compared to the baseline design. Overall, the results show that shared moorings do not introduce any dynamic response concerns in this floating wind array design.

17 WIND ENERGY↗

Unraveling plant phenotype to genotype associations with daily hyperspectral traits in Populus trichocarpa

Hyperspectral remote sensing is a powerful, high-throughput phenotyping tool that quantifies physiologically and structurally relevant wavelengths across diverse genotypes and over varying temporal scales. In this study, we combined tower-based continuous hyperspectral sensing with genome-wide association studies to analyze 1423 wavebands (400-900 nm) and derivative vegetation indices across 505 genotypes and the genetic architecture of hyperspectral phenotypes over time in Populus trichocarpa Torr. & Gray grown under field conditions. Wavelengths related to chlorophyll and carotenoid absorption spectra exhibited the strongest genetic variation resulting in 98 significant SNP associations. Notably, we found substantial overlap in genetic association between the blue and red spectral regions, indicative of carotenoids and chlorophyll, respectively, and identified more than 10 candidate genes associated with chloroplast function, underpinning photosynthetic activity. Furthermore, fluctuations in associations for vegetative indices, such as the chlorophyll:carotenoid index (CCI), across the growing season reveal a temporally dynamic genetic architecture of physiological traits associated with fall senescence of this temperate tree species. Finally, we also observed correlations (spearman rho = 0.3, p < 1x10 −8 ) between individual wavebands or vegetative indices and growth rate, assessed as the relative change of tree height over the growing season. The growth rate prediction was substantially improved by a regularization multivariate model (spearman rho>0.5, p < 1x10 −16 ), reinforcing the value of hyperspectral measurements for predicting traits linked to tree productivity. These findings highlight the potential of high-throughput, rapid, hyperspectral genome wide association studies GWAS to uncover physiologically meaningful genetic variation and offer promising insights for future acceleration for plant breeding.

09 BIOMASS FUELS↗

A Nonequilibrium Thermodynamic Approach for Surface Energy Balance Closure

Abstract The surface energy imbalance, viz. that the turbulent dissipation does not fully account for available energy, has for long been an outstanding challenge in geophysical studies. In this study, we developed a novel approach based on nonequilibrium thermodynamics by representing the atmospheric boundary layer as a heat engine. In addition, an analytically tractable approach was used to estimate the ground heat flux based on Green's function approach, which in turn determines the available energy that drives the atmospheric heat engine. The proposed model was evaluated using heat fluxes measured by eight AmeriFlux eddy covariance towers with atmospheric temperature profiles recorded at adjacent radiosonde sites. The surface energy balance closure can be improved by ~11% over various landscapes, by including the estimated power production from the atmospheric heat engine.

Li, Peiyuan↗

Dynamic blade loading in the ERDA/NASA 100 kW and 200 kW wind turbines

Dynamic blade loads, including aerodynamic, gravitational, and inertial effects, are presented for two large horizontal-axis wind turbines: the ERDA-NASA 100 kW Mod-0 and 200 kw Mod-0A wind power systems. Calculated and measured loads are compared for an experimental Mod-0 machine in operation. Predicted blade loads are also given for the higher power Mod-0A wind turbine now being assembled for operation as part of a municipal power plant. Two major structural modifications have been made to the Mod-0 wind turbine for the purpose of reducing blade loads. A stairway within the truss tower was removed to reduce the impulsive aerodynamic loading caused by the tower wake on the downwind rotor blades. Also, the torsional stiffness of the yaw drive mechanism connecting the turbine nacelle to the tower was doubled to reduce rotor-tower interaction loads. Measured reductions in load obtained by means of these two modifications equaled or exceeded predictions.

Spera, D. A.↗

Passive solar reflector satellite revisited

Passive light weight reflectors in space which direct the incident solar energy to a specified location on the Earth surface are proposed as an alternative system for the solar power satellite to overcome conversion losses and to avoid the need for photovoltaic cells. On Earth, either photovoltaic cells or a steam turbine alternator on a solar tower, or a similar conventional, relatively high efficiency cycle are used for electricity generation. The constraints which apply to the design of the optical system if a single satellite is placed in geostationary orbit are outlined. A single lens and a two lens system are discussed.

Polk, C.↗

Advanced Stirling receiver development program, phase 1

Critical technology experiments were designed and developed to evaluate the Stirling cavity heat pipe receiver for a space solar power system. Theoretical criteria were applied to the design of a module for containing energy storage phase change material while avoiding thermal ratcheting. Zero-g drop tower tests, without phase change, were conducted to affirm that the bubble location required to avoid ratcheting could be achieved without the use of container materials that are wetted by the phase change material. A full scale module was fabricated, but not tested. A fabrication method was successfully developed for the sodium evaporator dome, with a sintered screen wick, to be used as the focal point for the receiver. Crushing of the screen during hydroforming was substantially reduced over the results of other researchers by using wax impregnation. Superheating of the sodium in the wick under average flux conditions is expected to be under 10K. A 2000K furnace which will simulate solar flux conditions for testing the evaporator dome was successfully built and tested.

Lurio, Charles A.↗

Advancing Concentrating Solar Thermal Modeling Using System Advisor Model (SAM)

Concentrating solar thermal (CST) technologies play a critical role in enabling dispatchable power and high-temperature industrial heat applications. Accurate and flexible modeling tools are essential for evaluating system performance, guiding technology research and development, and informing investment decisions. The National Laboratory of the Rockies's System Advisor Model (SAM) is a widely used techno-economic simulation platform for CST systems, providing detailed performance and financial modeling capabilities for multiple CST system configurations. SAM integrates physics-based performance models with financial analysis to simulate the behavior of complex energy systems under realistic operating conditions. For CST technologies (including tower, parabolic trough, and linear Fresnel), SAM enables hourly simulations using site-specific weather data that ensure feasible operating conditions and convergence of mass and energy between core system components (i.e., solar field, receiver, thermal energy storage, and power cycle). These capabilities allow researchers and developers to evaluate annual energy production, capacity factors, levelized cost of energy (LCOE), and system dispatch strategies. A key advantage of SAM lies in its flexibility for parametric analysis and large-scale computational studies. Users can vary system design parameters such as heliostat field layout, receiver dimensions, thermal energy storage capacity, power block sizing, and installation cost assumptions to investigate their impact on system performance and financial metrics. When combined with automated scripting through LK, SDKTool, or Python interfaces, SAM enables high-throughput simulation workflows that support sensitivity analysis, technology benchmarking, and optimization studies. These approaches are particularly valuable for next-generation CST concepts, where design spaces are large and system interactions are complex. Another important capability of SAM is its support for dispatch optimization and thermal energy storage modeling, which are central to the value proposition of CST technologies. The ability to simulate integrated storage and flexible power generation allows researchers to explore strategies that maximize grid value, improve capacity utilization, and enhance integration with variable resources such as photovoltaic and wind generation. This poster will present an overview of SAM's thermal system modeling capabilities including concentrating solar. Additionally, we will highlight new feature developments including: 1) implementing Google's OR-Tools optimization platform for faster and more robust dispatch optimization, 2) developing a new power load following controller for modeling behind-the-meter applications, 3) enabling direct modeling of CSP-PV hybrid systems with the inclusion of battery storage, and 4) developing a multi-receiver falling particle Gen3 system model.

14 SOLAR ENERGY↗

FY12 Report: Meteorological Observations for Renewable Energy Applications at Site 300

Accurate, high-resolution meteorological measurements of wind flow in the planetary boundary layer (PBL) and surface-atmosphere energy exchange are required for understanding the properties and quality of available wind power at Site 300. Wind speeds at heights found in a typical wind turbine rotor disk (~ 40- 120 m) are driven by the synergistic impacts of atmospheric stability, orography, and land-surface characteristics on the mean wind flow and related turbulence structures in the PBL. In FY11, two Laser and Detection Ranging (LIDAR) units, a 3 m tall flux tower, and a 3 m tall meteorological tower were installed in the northern section of Site 300 as a first step in development of a renewable energy testbed facility. The LIDAR units were programmed to measure wind speed and direction up to 200 m. The flux tower measured land surface-atmospheric energy exchanges and provided information on the mechanisms for turbulence production in the atmosphere and atmospheric stability. Atmospheric stability largely determines wind speed and turbulence profiles in the lower part of the boundary layer where wind turbines reside. In FY12 the SMS project was further expanded by the earlier addition of solar power to the LIDAR units. This enabled the units to be moved to different areas within Site 300 in order to gather a larger spatial range of measurements. Additional LIDAR locations were chosen based on (1) feasibility and logistics (e.g., away from the blast zone and special habitat zones) and (2) areas forecasted to have high wind speeds and/or high turbulence from the Weather Research and Forecasting (WRF) model simulations. High turbulence is of interest because very high amounts of turbulent energy can be damaging to turbine components. Between December 2011-April 2012, the two LIDAR units were rotated amongst three locations: the tall (52 m) meteorological tower, the radio tower, and the Matthew area (named after Matthew Simpson) (Figure 1). The radio tower location was in the center of Site 300 and represented the site with highest elevation and potentially highest wind speeds as forecasted by WRF. The Matthew area in the southeast represented a site with high wind speeds and potentially high levels of turbulence. In FY11 we presented a quality control report which illustrated the accuracy of the LIDAR wind speed and direction measurements as compared to the 52 m tall meteorological tower and provided annual statistics for wind speed and direction up to 200 m for the meteorological tower location in the northern section of Site 300. In the FY12 report we present: 1. a second year of LIDAR and flux tower statistics for 2012, 2. an enhanced spatial dataset of LIDAR observations with the addition of two new sites, and 3. a look at off-site LIDAR field campaigns.

17 WIND ENERGY↗

Reducing water freshwater consumption at coal-fired power plants : approaches used outside the United States.

Coal-fired power plants consume huge quantities of water, and in some water-stressed areas, power plants compete with other users for limited supplies. Extensive use of coal to generate electricity is projected to continue for many years. Faced with increasing power demands and questionable future supplies, industries and governments are seeking ways to reduce freshwater consumption at coal-fired power plants. As the United States investigates various freshwater savings approaches (e.g., the use of alternative water sources), other countries are also researching and implementing approaches to address similar - and in many cases, more challenging - water supply and demand issues. Information about these non-U.S. approaches can be used to help direct near- and mid-term water-consumption research and development (R&D) activities in the United States. This report summarizes the research, development, and deployment (RD&D) status of several approaches used for reducing freshwater consumption by coal-fired power plants in other countries, many of which could be applied, or applied more aggressively, at coal-fired power plants in the United States. Information contained in this report is derived from literature and Internet searches, in some cases supplemented by communication with the researchers, authors, or equipment providers. Because there are few technical, peer-reviewed articles on this topic, much of the information in this report comes from the trade press and other non-peer-reviewed references. Reducing freshwater consumption at coal-fired power plants can occur directly or indirectly. Direct approaches are aimed specifically at reducing water consumption, and they include dry cooling, dry bottom ash handling, low-water-consuming emissions-control technologies, water metering and monitoring, reclaiming water from in-plant operations (e.g., recovery of cooling tower water for boiler makeup water, reclaiming water from flue gas desulfurization [FGD] systems), and desalination. Some of the direct approaches, such as dry air cooling, desalination, and recovery of cooling tower water for boiler makeup water, are costly and are deployed primarily in countries with severe water shortages, such as China, Australia, and South Africa. Table 1 shows drivers and approaches for reducing freshwater consumption in several countries outside the United States. Indirect approaches reduce water consumption while meeting other objectives, such as improving plant efficiency. Plants with higher efficiencies use less energy to produce electricity, and because the greater the energy production, the greater the cooling water needs, increased efficiency will help reduce water consumption. Approaches for improving efficiency (and for indirectly reducing water consumption) include increasing the operating steam parameters (temperature and pressure); using more efficient coal-fired technologies such as cogeneration, IGCC, and direct firing of gas turbines with coal; replacing or retrofitting existing inefficient plants to make them more efficient; installing high-performance monitoring and process controls; and coal drying. The motivations for increasing power plant efficiency outside the United States (and indirectly reducing water consumption) include the following: (1) countries that agreed to reduce carbon emissions (by ratifying the Kyoto protocol) find that one of the most effective ways to do so is to improve plant efficiency; (2) countries that import fuel (e.g., Japan) need highly efficient plants to compensate for higher coal costs; (3) countries with particularly large and growing energy demands, such as China and India, need large, efficient plants; (4) countries with large supplies of low-rank coals, such as Germany, need efficient processes to use such low-energy coals. Some countries have policies that encourage or mandate reduced water consumption - either directly or indirectly. For example, the European Union encourages increased efficiency through its cogeneration directive, which requires member states to assess their national potential for cogeneration, analyze barriers to achieving the potential, and then establish support schemes to achieve the potential. China's Eleventh Five-Year Plan (2006-2010) has an energy strategy that specifies, among other things, that production should be optimized by promoting the development of large-scale, high-efficiency units, and that air-cooled technologies should be used in areas with water shortages. The United States lacks many of these drivers. There are no government requirements that mandate more efficient plants. The United States has ample supplies of relatively cheap coal, and U.S. water-short areas are not as extensive as in countries such as China, South Africa, and Australia. Often, other countries have deployed water-savings technologies to a greater degree than the United States.

01 COAL, LIGNITE, AND PEAT↗

Application of Ensemble Sensitivity Analysis to Observation Targeting for Short-term Wind Speed Forecasting in the Washington-Oregon Region

To economically and reliably balance electrical load and generation, electrical grid operators, also called Balancing Authorities (BA), need highly accurate electrical power generation forecasts in time frames ranging from a few minutes to six hours ahead. As wind power generation increases, there is a requirement to improve the accuracy of 0- to 6-hour ahead wind power forecasts. Forecasts covering this short look-ahead period have depended heavily on short-term trends obtained from the actual power production and meteorological data of a wind generation facility. Additional data are often available from Numerical Weather Prediction (NWP) models and sometimes from off-site meteorological towers near wind generation facilities.

17 WIND ENERGY↗

Observations of intermediate- and high-degree p-mode oscillations during sunspot cycles 21 and 22

Extensive time series of resolved solar images have been available for helioseismological investigations since the late 1970's. The paper presents examples of the frequencies, power levels, modal energies, and widths of solar intermediate-degree and high-degreee p-modes obtained at the Mt. Wilson Observatory's 60-Foot Solar Tower Telescope during the rising phase of the current sunspot cycle. It is shown that the inclusion of frequency splittings from the high-degree p-modes has made it possible to demonstrate that the sun's internal equatorial angular velocity is not constant with radius but varies systematically with radius throughout the solar convection zone and below.

Rhodes, E. J.↗

Buoyancy Effects on Flow Structure and Instability of Low-Density Gas Jets

A low-density gas jet injected into a high-density ambient gas is known to exhibit self-excited global oscillations accompanied by large vortical structures interacting with the flow field. The primary objective of the proposed research is to study buoyancy effects on the origin and nature of the flow instability and structure in the near-field of low-density gas jets. Quantitative rainbow schlieren deflectometry, Computational fluid dynamics (CFD) and Linear stability analysis were the techniques employed to scale the buoyancy effects. The formation and evolution of vortices and scalar structure of the flow field are investigated in buoyant helium jets discharged from a vertical tube into quiescent air. Oscillations at identical frequency were observed throughout the flow field. The evolving flow structure is described by helium mole percentage contours during an oscillation cycle. Instantaneous, mean, and RMS concentration profiles are presented to describe interactions of the vortex with the jet flow. Oscillations in a narrow wake region near the jet exit are shown to spread through the jet core near the downstream location of the vortex formation. The effects of jet Richardson number on characteristics of vortex and flow field are investigated and discussed. The laminar, axisymmetric, unsteady jet flow of helium injected into air was simulated using CFD. Global oscillations were observed in the flow field. The computed oscillation frequency agreed qualitatively with the experimentally measured frequency. Contours of helium concentration, vorticity and velocity provided information about the evolution and propagation of vortices in the oscillating flow field. Buoyancy effects on the instability mode were evaluated by rainbow schlieren flow visualization and concentration measurements in the near-field of self-excited helium jets undergoing gravitational change in the microgravity environment of 2.2s drop tower at NASA John H. Glenn Research Center. The jet Reynolds number was varied from 200 to 1500 and jet Richardson number was varied from 0.72 to 0.002. Power spectra plots generated from Fast Fourier Transform (FFT) analysis of angular deflection data acquired at a temporal resolution of 1000Hz reveal substantial damping of the oscillation amplitude in microgravity at low Richardson numbers (~0.002). Quantitative concentration data in the form of spatial and temporal evolutions of the instability data in Earth gravity and microgravity reveal significant variations in the jet flow structure upon removal of buoyancy forces. Radial variation of the frequency spectra and time traces of helium concentration revealed the importance of gravitational effects in the jet shear layer region. Linear temporal and spatio-temporal stability analyses of a low-density round gas jet injected into a high-density ambient gas were performed by assuming hyper-tan mean velocity and density profiles. The flow was assumed to be non parallel. Viscous and diffusive effects were ignored. The mean flow parameters were represented as the sum of the mean value and a small normal-mode fluctuation. A second order differential equation governing the pressure disturbance amplitude was derived from the basic conservation equations. The effects of the inhomogeneous shear layer and the Froude number (signifying the effects of gravity) on the temporal and spatio-temporal results were delineated. A decrease in the density ratio (ratio of the density of the jet to the density of the ambient gas) resulted in an increase in the temporal amplification rate of the disturbances. The temporal growth rate of the disturbances increased as the Froude number was reduced. The spatio-temporal analysis performed to determine the absolute instability characteristics of the jet yield positive absolute temporal growth rates at all Fr and different axial locations. As buoyancy was removed (Fr . 8), the previously existing absolute instability disappeared at all locations establhing buoyancy as the primary instability mechanism in self-excited low-density jets.

Pasumarthi, Kasyap Sriramachandra↗

Towards Erecting Straighter Lightweight Towers on the Moon Using Deployable Guy Wires

This paper reports our static stability test findings for a simple guy wire system to correct the natural lateral deflections of an 8.5m tall, compact deployable composite tower intended to support exploration of lunar permanently shadowed regions by nearby robotic assets. Deployable composite booms with microgravity flight heritage are currently being investigated at NASA Langley Research Center (LaRC) and Massachusetts Institute of Technology(MIT)’s Space Resources Workshop for their potential to be vertically deployed in the lunar gravity field, in support of NASA’s Artemis campaign. These applications include vertical solar arrays and the provision of elevated lines-of-sight to science or engineering payloads on landers and rovers, in support of nearby or distant crewed or robotic assets exploring scientifically interesting and hard to reach areas. Useful elevated payloads include radio repeaters, remote sensing and imaging, navigation and power beaming systems. However, while these lightweight booms have an excellent height to mass ratio, they typically exhibit slight axial curvature upon deployment resulting in appreciable lateral dead-load deflection of the tip mass relative to the tower base. This static deflection increases with tower height and tip mass, not only constraining the value delivered by the tower but also endangering its integrity. To develop a competitive, lightweight deployable composite boom tower, a capability to correct static deflections during and after deployment may be required. This paper presents a pathfinder deployable guy wire stability system for the MIT / LaRC self-erecting composite boom lunar tower that provides real time measurements, maintains tension passively, and can serve as a reconfigurable platform to test new guy wire components, configurations and control algorithms. Using a validated, calibrated photogrammetry system, the natural lateral deflection of the boom tip relative to the boom base at different deployed heights in Earth’s gravity field was recorded. With real-time tension measurements it was found that guy wires can significantly reduce the tip deflection of a deployable composite boom under dead load. Specifically, we found that (1) control capability is greatest where it is needed most, i.e. for the lever arm closest to being opposite the direction of deflection, and (2) for a tower height of at least 8.5 m and arm length of at least 60 cm, a solution of differential tension in all three arms exists and, in principle, provides sufficient control capability to correct or significantly reduce boom deflections. We also found that natural deflections occur almost entirely out-of-plane of the seams of the boom cross-section, which was expected, and that the natural boom tip lateral deflection under dead load upon deployment was ~5% of boom deployed length, unexpectedly exceeding the manufacturing acceptance specification of 1%.Ongoing and future collaborative work between LaRC and MIT includes the further investigation of the unexpected lateral deflection, testing of alternative guy wire system designs at higher tensions and higher deployed heights, as well as trade studies of costs and benefits of an optimized integrated guywire system compared to other types of static stability solutions.

lunar towers↗

Design and calculated performance and cost of the ECAS Phase II open cycle MHD power generation system

A 2000 MWe MHD/steam plant for central station applications has been designed and costed as part of the Energy Conversion Alternatives Study (ECAS). This plant is fueled by Illinois No. 6 coal, rejects heat through mechanical draft wet cooling towers, and includes coal processing equipment, seed reprocessing, electrical inversion of the MHD generator output and emission controls to current EPA standards. It yields an estimated overall efficiency of 0.483 (7066 Btu/kWe-hr), a capital cost of $718 per kWe (1975 dollars), and a cost of electricity at 65% capacity factor of 32 mills per kWe-hr. If the assumed life and reliability could be achieved with these performance parameters, the MHD system should prove attractive.

Harris, L. P.↗

Ice Thermal Storage Systems for LWR Supplemental Cooling and Peak Power Shifting

Availability of enough cooling water has been one of the major issues for the nuclear power plant site selection. Cooling water issues have frequently disrupted the normal operation at some nuclear power plants during heat waves and long draught. The issues become more severe due to the new round of nuclear power expansion and global warming. During hot summer days, cooling water leaving a power plant may become too hot to threaten aquatic life so that environmental regulations may force the plant to reduce power output or even temporarily to be shutdown. For new nuclear power plants to be built at areas without enough cooling water, dry cooling can be used to remove waste heat directly into the atmosphere. However, dry cooling will result in much lower thermal efficiency when the weather is hot. One potential solution for the above mentioned issues is to use ice thermal storage systems (ITS) that reduce cooling water requirements and boost the plant’s thermal efficiency in hot hours. ITS uses cheap off-peak electricity to make ice and uses those ice for supplemental cooling during peak demand time. ITS is suitable for supplemental cooling storage due to its very high energy storage density. ITS also provides a way to shift large amount of electricity from off peak time to peak time. Some gas turbine plants already use ITS to increase thermal efficiency during peak hours in summer. ITSs have also been widely used for building cooling to save energy cost. Among three cooling methods for LWR applications: once-through, wet cooling tower, and dry cooling tower, once-through cooling plants near a large water body like an ocean or a large lake and wet cooling plants can maintain the designed turbine backpressure (or condensation temperature) during 99% of the time; therefore, adding ITS to those plants will not generate large benefits. For once-through cooling plants near a limited water body like a river or a small lake, adding ITS can bring significant economic benefits and avoid forced derating and shutdown during extremely hot weather. For the new plants using dry cooling towers, adding the ice thermal storage systems can effectively reduce the efficiency loss and water consumption during hot weather so that new LWRs could be considered in regions without enough cooling water. \ This paper presents the feasibility study of using ice thermal storage systems for LWR supplemental cooling and peak power shifting. LWR cooling issues and ITS application status will be reviewed. Two ITS application case studies will be presented and compared with alternative options: one for once-through cooling without enough cooling for short time, and the other with dry cooling. Because capital cost, especially the ice storage structure/building cost, is the major cost for ITS, two different cost estimation models are developed: one based on scaling method, and the other based on a preliminary design using Building Information Modeling (BIM), an emerging technology in Architecture/Engineering/Construction, which enables design options, performance analysis and cost estimating in the early design stage.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Passive decay heat removal system design for the integral inherent safety light water reactor (I 2 S-LWR)

The Integral, Inherently Safe Light Water Reactor (I 2 S-LWR) is an innovative Pressurized Water Reactor (PWR) concept being developed by a multi-institutional team led by Georgia Tech and in collaboration with Westinghouse, under the Department of Energy’s Nuclear Energy University Programs Integrated Research Projects (DOE NEUP IRP). The University of Michigan leads the design of the thermalhydraulic and passive safety systems, in collaboration with Westinghouse and Bringham Young University. The I 2 S-LWR features an integral primary system configuration and is more conducive to the implementation of inherent safety features by eliminating potential accidents. In this paper, a novel passive Decay Heat Removal System (DHRS), is presented, consisting of a primary loop, an intermediate loop and a cooling tower loop. This passive system is designed to remove the I 2 S-LWR decay heat in the case of emergency heat removal transients, without the need for external power or operator action. The proposed DHR uses atmosphere as ultimate heat sink, to achieve indefinite decay heat removal. In this paper, firstly, the design of primary and secondary DHRS heat exchangers is optimized. Then the DHR heat removal characteristics are studied using the best-estimate thermal hydraulic code RELAP5. In addition, CFD simulations have been performed in order to investigate the DRHS helical coil primary heat exchanger performance with different coil pipe arrangements, and optimize its design. The performance of the proposed DHRS concept is investigated in case of a Station Black-Out (SBO) scenario. Operation of two, three and four DHRS trains is studied respectively. The findings show that three out of four DHRS trains are sufficient to indefinitely remove the core decay heat successfully during a SBO, and keep the reactor in a safe state without the need of any other auxiliary active system.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗