Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Photon”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Low Cost Solar Array Project: Composition Measurements by Analytical Photon Catalysis

The applicability of the photon catalysis technique for effecting composition analysis of silicon samples was assessed. Third quarter activities were devoted to the study of impurities in silicon matrices. The evaporation process was shown to be congruent; thus, the spectral analysis of the vapor yields the composition of the bulk sample. Qualitative analysis of metal impurities in silicon was demonstrated e part per million level. Only one atomic spectral interference was noted; however, it is imperative to maintain a leak tight system due to chemical and spectral interferences caused by the presence of even minute amounts of oxygen in the active nitrogen afterglow.

Sutton, D. G.↗

Coding for optical channels with photon-counting

The problem of coding for Pierce's recent model for optical communications is studied. It was concluded that for any positive rate rho (measured in nats per photon), the best code of length n has an error probability bounded by an exponentially decaying function of n. Explicit practical schemes are shown for rho less than or = to 1; and evidence is given that rho approximating 1 may be the practical limit for optical communication.

Mceliece, R. J.↗

Photon position determination using microchannel plates

The reasons for developing an X-ray photon position detector and a description of the system and its laboratory performance have been presented by Kubierschky et al. (1977) and by Kellogg et al. (1976). The reported investigation is concerned with an expansion of the design criteria for the analog function and their implementation in available hardware. A charge event is received by the preamplifier of each axis, grouped and processed by the summing amplifiers, verified by the pulse height analyzer, sorted by the charge center detector, stored by sample/holds, and converted by the multiplying analog to digital converter. The various components are discussed.

Harrison, D.↗

Optical communication with two-photon coherent states. II - Photoemissive detection and structured receiver performance

In a previous paper (1978), the authors developed a method of analyzing the performance of two-photon coherent state (TCS) systems for free-space optical communications. General theorems permitting application of classical point process results to detection and estimation of signals in arbitrary quantum states were derived. The present paper examines the general problem of photoemissive detection statistics. On the basis of the photocounting theory of Kelley and Kleiner (1964) it is shown that for arbitrary pure state illumination, the resulting photocurrent is in general a self-exciting point process. The photocount statistics for first-order coherent fields reduce to those of a special class of Markov birth processes, which the authors term single-mode birth processes. These general results are applied to the structure of TCS radiation, and it is shown that the use of TCS radiation with direct or heterodyne detection results in minimal performance increments over comparable coherent-state systems. However, significant performance advantages are offered by use of TCS radiation with homodyne detection. The abstract quantum descriptions of homodyne and heterodyne detection are derived and a synthesis procedure for obtaining quantum measurements described by arbitrary TCS is given.

Shapiro, J. H.↗

Simulation studies for a nuclear photon pumped excimer laser

Simulation studies were undertaken to determine the feasibility of a nuclear photon pumped excimer laser using a system where high pressure Xe is bombarded with electrons and protons to form 1720 A. Primary measurements included conversion efficiency and gain vs time measurements.

Miller, T. G.↗

Optical communication with two-photon coherent states. III - Quantum measurements realizable with photoemissive detectors

Homodyne detection is shown to achieve the same signal-to-noise ratio as the quantum field quadrature measurement, thus providing a receiver which realizes linear modulation TCS performance gain. The full equivalence of homodyne detection and single-quadrature field measurement is established. A heterodyne configuration which uses a TCS image-band oscillator in addition to the usual coherent state local oscillator is studied. Results are obtained by means of a representation theorem which shows that photoemissive detection realizes the photon flux density measurement.

Yuen, H. P.↗

Energy loss by resonance line photons in an absorbing medium

The mean path length of photons undergoing repeated scatterings in media of large optical thickness is calculated from accurate numerical solutions of the transfer equation including the effect of frequency redistribution characteristic of combined Doppler and natural broadening. Energy loss by continuous absorption processes, such as ionization or dust absorption, is discussed, and asymptotic scaling laws for the energy loss, the mean path length, and the mean number of scatterings are inferred from the numerical data.

Hummer, D. G.↗

Interleaved block codes for the photon channel

It is shown that interleavel binary block codes combined with pulse position modulation give the best practical coded systems yet devised for optical communication with photon detection. Linear block codes rather than convolutional codes are considered.

Mceliece, R. J.↗

The energy loss of relativistic electrons in energetic photon gases and its relation to the equilibrium spectrum of electrons

The energy loss of relativistic electrons is considered for astrophysical objects which contain energetic photon gases in the XUV-range. Such objects have been suggested as possible candidates for gamma-ray point sources through the mechanism of inverse Compton scattering. In certain cases where inverse Compton scattering is the dominant energy loss mechanism, an equilibrium spectrum results which can deviate from a strict power law. Such an effect can have consequences on the observed radiation spectrum from such objects.

Prince, T.↗

Preliminary results from a single-photon imaging X-ray charge coupled device /CCD/ camera

A CCD camera is described which has been designed for single-photon X-ray imaging in the 1-10 keV energy range. Preliminary results are presented from the front-side illuminated Fairchild CCD 211, which has been shown to image well at 3 keV. The problem of charge-spreading above 4 keV is discussed by analogy with a similar problem at infrared wavelengths. The total system noise is discussed and compared with values obtained by other CCD users.

Griffiths, R. E.↗

Wedge-and-strip anodes for centroid-finding position-sensitive photon and particle detectors

The paper examines geometries employing position-dependent charge partitioning to obtain a two-dimensional position signal from each detected photon or particle. Requiring three or four anode electrodes and signal paths, images have little distortion and resolution is not limited by thermal noise. An analysis of the geometrical image nonlinearity between event centroid location and the charge partition ratios is presented. In addition, fabrication and testing of two wedge-and-strip anode systems are discussed. Images obtained with EUV radiation and microchannel plates verify the predicted performance, with further resolution improvements achieved by adopting low noise signal circuitry. Also discussed are the designs of practical X-ray, EUV, and charged particle image systems.

Martin, C.↗

Evaluation and universal curves of the photon loss probability

In the transfer of radiation in a plasma, an important parameter (which measures the coupling between the radiation field and the electron gas) is the photon loss probability per scattering epsilon, defined as the ratio of collisional de-excitation to total de-excitation. The evaluation of epsilon requires normally knowledge of specific collisional excitation rates and radiative transition rate coefficients. In the considered investigation a general formula for epsilon is obtained which depends only on electron density, temperature, and line wavelength. Use is made of a simple Bethe-Coulomb expression recently derived by Kastner (1980) for the collisional excitation rate coefficient. Epsilon is obtained as a function of the three variables, and universal curves of it can be constructed with one of the variables as parameter. As an example of the application of the considered procedure, the variation of epsilon with height h in the solar atmosphere is shown in a graph for several solar lines.

Kastner, S. O.↗

The two-photon absorptivity of rotational transitions in the A2 Sigma hyperon + (v prime = O) - X-2 pion (v prime prime = O) gamma band of nitric oxide

A predominantly single-mode pulsed dye laser system giving a well characterized spatial and temporal output suitable for absolute two-photon absorptivity measurements was used to study the NO gamma(0,0) S11 + R21 (J double prime = 7-1/2) transition. Using a calibrated induced-fluorescence technique, an absorptivity parameter of 2.8 + or - 1.4 x 10 to the minus 51st power cm to the 6th power was obtained. Relative strengths of other rotational transitions in the gamma(0,0) band were also measured and shown to compare well with predicted values in all cases except the O12 (J double prime = 10-1/2) transition.

Gross, K. P.↗

A photon-counting photodiode array detector for far ultraviolet (FUV) astronomy

A compact, stable, single-stage intensified photodiode array detector designed for photon-counting, far ultraviolet astronomy applications employs a saturable, 'C'-type MCP (Galileo S. MCP 25-25) to produce high gain pulses with a narrowly peaked pulse height distribution. The P-20 output phosphor exhibits a very short decay time, due to the high current density of the electron pulses. This intensifier is being coupled to a self-scanning linear photodiode array which has a fiber optic input window which allows direct, rigid mechanical coupling with minimal light loss. The array was scanned at a 250 KHz pixel rate. The detector exhibits more than adequate signal-to-noise ratio for pulse counting and event location.

Hartig, G. F.↗

Hydrogen two photon emission in the UV spectrum of type 2 supernovae

The continuum emission of Type 2 supernovae demonstrates an ultraviolet (UV) excess when fit by black body emission is attempted. The H two photon emission is advanced as an explanation of the UV excess. A function by which the UV spectra of two Type 2 supernovae (SN 1979c in NGC 4321 and SN 1980k in NGC 6946) are fitted with U,B,V photometric data is presented. The angular velocity of expansion of the supernovae envelope is derived. From this, the linear velocity of expansion and the distances of the parent galaxies are derived. A distance of 17.3 Mpc is obtained for NGC 4321, and a distance of 7.1 Mpc for NGC 6946.

Benvenuti, P.↗

The 2.5 bit/detected photon demonstration program: Phase 2 and 3 experimental results

The experimental program for laboratory demonstration of and energy efficient optical communication channel operating at a rate of 2.5 bits/detected photon is described. Results of the uncoded PPM channel performance are presented. It is indicated that the throughput efficiency can be achieved not only with a Reed-Solomon code as originally predicted, but with a less complex code as well.

Katz, J.↗

Prospects for very deep space optical communication using photon-counting links

An investigation is conducted regarding the feasibility to use an optical communication system in connection with space missions involving a study of stars and, possibly, planetary systems in the vicinity of the solar system. A possible candidate for the considered kind of mission would be Barnard's Star, at six light years distance. Pierce et al. (1981), have shown that the capacity of a photon-counting link in the presence of thermal noise at low temperature is essentially the same as for microwave. The conducted investigation assumes the employment of a pulse position modulation scheme limited by technology to approximately 1,000,000 positions. The use of an optical communication system similar to the considered type is found to be very likely for the contemplated kind of space mission.

Posner, E. C.↗

Single photon X-ray imaging with charge-coupled devices /CCDs/

The paper describes a CCD camera facility designed and built for testing and characterization of CCDs in response to single X-ray photons in the 1-10 keV energy range. Results from the frontside-illuminated Fairchild 211 and 221 area imagers are presented; high quantum efficiency over the 3-6 keV range was verified. In order to avoid the problem of charge spreading at the higher energies, deep-depleted CCDs for soft X-ray imaging have been constructed, and good response was obtained at 6 keV. The present results are a first step toward the demonstration of the CCD as an appropriate device for at least the central part of the focal plane of a large X-ray telescope, e.g., the proposed Advanced X-ray Astrophysics Facility.

Griffiths, R. E.↗