Methods to Evaluate Embedded Sensor Performance and Reliability in TCR Components
Explore the source record for details and available documents.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Modern modeling techniques were used to investigate a proposed method for fast neutron irradiations in an existing thermal-spectrum reactor, the Advanced Test Reactor (ATR). This method builds upon pre-existing ideas, where fast flux is increased by surrounding the specimens with fissionable “booster fuel” but diverges from historical approaches by using an already developed fuel element design used in the Belgian Reactor 2 (BR2) as the booster fuel while leveraging modern 3-D modeling and simulation techniques. Design evaluations and neutronics simulations were performed to evaluate the performance of a BR2 fuel element irradiated in an ATR flux trap with test pins in the central channel of the BR2 fuel element. These efforts have yielded promising results. Adding a BR2 fuel element in the northeast (NE) flux trap of ATR was predicted to result in a 150% increase to the incident fast neutron flux with a fast (>0.1 MeV) to thermal (<0.625 eV) neutron flux ratio ranging from approximately 50 to 150, dependent on the material used for thermal neutron filtering and volume of moderator within the central channel of the BR2 element. The predicted annual fast neutron fluence (>0.1 MeV) ranges from 7.9 × 1021 to 9.1 × 1021 n/cm2. Given the relatively large fast to thermal neutron flux ratio, the calculated radial power profiles within 4.3 mm outer diameter U10Zr fueled specimens irradiated within the BR2 booster fuel element are adequate representations of those within fast neutron reactors. The predicted radial power profiles are not flat, but they are more prototypic than those seen in advanced fuels tests which began in ATR in 2003. Another distinct advantage of this experiment design is that full-scale test pins can be irradiated to augment the ongoing series of reduced scale advanced fuels tests. The proposed experiment design irradiated within a BR2 fuel element in a flux trap of ATR offers an improved alternative to the current testing of advanced reactor fuels in ATR. Selected results from this design evaluation are presented.
This study investigates the performance of a propane hydronic heat pump system for space cooling, heating, and water heating applications, focusing on various operational conditions, with a total refrigerant charge below 1200 g. Cooling performance was evaluated at different outdoor temperatures, compressor stages (capacity levels), and water flow rates. The results showed that the coefficient of performance (COP) for cooling was higher at lower outdoor temperatures, with peak values exceeding 5.0 under low-stage operation and lower water flow rate. The cooling capacity increased with higher flow rates and compressor stages, reaching 12 kW. Space heating performance, evaluated at ambient temperatures ranging from −8.3 °C to 16.7 °C, revealed a decrease in COP with lower temperatures. However, high-stage operation maintained higher heating capacities even at low temperatures. The system demonstrated high Heating Seasonal Performance Factors (HSPF), exceeding 10.0. For water heating, the COP decreased with lower ambient temperatures and higher supply water temperatures. The system efficiently heated an 189-L water tank, outperforming conventional water heaters, with process COPs exceeding 4.0 under cooling-season conditions. Despite some efficiency loss due to defrosting at low temperatures, the propane heat pump consistently delivered strong performance. Seasonal energy efficiency ratios (SEER) and seasonal heating COP values indicated significant overall efficiency. The study concludes that propane is a promising refrigerant for heat pump systems, with future research needed to future reduce total system charge and optimize system performance through advanced controls and heat exchanger designs.
A high-altitude electromagnetic pulse (HEMP) or similar geomagnetic disturbance (GMD) has the potential to impact the operation of large-scale electric power grids. By introducing low-frequency common-mode (CM) currents, these events can degrade the performance of critical system components, such as large power transformers by introducing CM currents which can lead to magnetic saturation of the transformer core. In this work, a solid-state transformer (SST) is developed to replace susceptible equipment and improve grid resiliency by safely absorbing these CM disturbances. This device will be referred to as a common-mode solid-state transformer (CM-SST). An SST architecture based on a four-legged AC/DC converter is developed. This architecture enables active control of CM signals without disturbing the AC voltages or the real and reactive power delivery capabilities. A system-level model of this architecture is created, and time-domain simulations are performed to evaluate the SST’s performance in response to simulated CM disturbances. A control strategy for mitigating CM current is also investigated. Hamiltonian surface shaping and power flow control (HSSPFC) is used to design a nonlinear controller for the SST’s output inverter. The objectives of the controller are to suppress CM-induced AC current offsets and regulate AC currents to desired setpoints. Nonlinear system analysis is applied to design and validate the controller. Two cases are tested: (a) the proposed four-leg inverter and (b) a standard three-leg inverter. The results show that the proposed controller rapidly mitigates CM disturbances while maintaining high-quality AC current waveforms in the four-leg configuration. Finally, the hardware performance of an SST prototype is evaluated. In particular, the ability of the SST to safely redirect and absorb CM currents is demonstrated, showing how it can protect neighboring conventional transformers in the system. The study confirms that appropriate control laws allow the SST to protect both itself and adjacent transformers during a HEMP or GMD event.
Fenestration systems are widely used across the world. There is expansive research on window configurations, frames, and glazing technology, but not enough research has been published on reducing window heat loss through heat application to a pane. The presented study attempted to evaluate the performance of heated windows by developing an experimental setup to test a window at various temperatures by varying the power input to the window. Heated double pane window was installed in an insulated box. A temperature gradient was developed across the window by cooling one side of the window using gel-based ice packs. The other face of the window was heated by enabling power at different wattages through the window. The temperature of the inside and outside panes, current and voltage input, and temperature of the room and box were recorded. The data was used to calculate the apparent effective resistance of the window when not being heated vs. when being heated. The study concluded that, when window temperature was maintained close to the room temperature, the heated double pane window is effective in reducing heat loss by as much as 50% as compared to a non-heated double pane window. When temperature of the window was much higher than the room temperature, the heat loss through the window increased beyond that of a non-heated window. The issues encountered during the current stages of experiments are noted, and recommendations are provided for future studies.
This presentation touches on motivation and applications of Zirconium. Performance of evaluated libraries on double and quasi differential experiments is considered. Additionally, the performance of evaluated libraries in select ICSBEP benchmarks is considered. Provided is a detailed look in the performance of evaluated libraries in preliminary benchmark configurations for IER-516: Zirconium Test Assembly (ZTA). Conclusions and recommended experiments to satisfy Zirconium scattering nuclear data needs are presented.
The control systems at Air handling units (AHUs) have nonlinear nature, resulting potentially in sluggish, aggressive, or oscillatory responses under variable operation conditions. This paper is to develop an approach for evaluating the nonlinear control performance of AHUs under variable operation conditions and for identifying the impact of varying multiple operation parameters which guides controller design. To do so, an operation parameter-based root distribution technique, intended to sketch the paths traced by closed-loop poles as multiple operation parameters are varied, is first introduced. The technique—which may be viewed as an extension of conventional, single-variable root locus—is then applied to a fan speed control system that includes a motor with a variable frequency drive and a supply fan with an air duct under variable fan speed and duct static pressure. Using the technique, the system’s stability region is graphically identified. The system is also found to be aggressive and gradually lose its stability as the fan speed decreases and the duct static pressure increases, which is validated by the field tests. Here, the root distribution approach is an effective tool to evaluate the performance of any nonlinear control systems at AHUs with multiple variable operation parameters without requiring time-domain simulations.
A high-performance cold-climate heat pump (CCHP) was developed and experimentally validated through comprehensive laboratory and field testing. The system utilized two equal-size tandem vapor-injection (VI) compressors with an inter-stage flash tank to improve efficiency and capacity retention under subfreezing conditions. Laboratory testing was conducted on a 3-ton prototype in a controlled environmental chamber equipped with calibrated thermocouples, refrigerant-side mass flow and pressure transducers, and precision airflow measurement for energy balance verification. The prototype achieved heating coefficients of performance (COPs) of 4.4 at 47 °F, 3.1 at 17 °F, and 2.0 at –13 °F, while maintaining 88% of its rated heating capacity at –13°F. These results confirm strong low-temperature performance and indicate the potential for significant reductions in electric resistance backup use. A field prototype was installed and monitored in a residential building in Fairbanks, Alaska, during a heating season. Instrumentation included real-time power, temperature, and refrigerant state measurements to evaluate performance under dynamic outdoor conditions. The heat pump operated reliably down to –30 °F, delivering 75% of its rated heating capacity with a COP of 1.8, while maintaining stable operation, effective defrost control, and indoor comfort without auxiliary heating. The combined laboratory and field results demonstrate that the tandem VI compressor configuration provides a practical and energy-efficient approach for residential heat pumps designed for cold and very cold climate regions.
The area under the receiver operating characteristic curve (AUC) is widely used in evaluating diagnostic performance for many clinical tasks. It is still challenging to evaluate the reading performance of distinguishing between positive and negative regions of interest (ROIs) in the nested-data problem, where multiple ROIs are nested within the cases. To address this issue, we identify two kinds of AUC estimators, within-cases AUC and between-cases AUC. We focus on the between-cases AUC estimator, since our main research interest is in patient-level diagnostic performance rather than location-level performance (the ability to separate ROIs with and without disease within each patient). Another reason is that as the case number increases, the number of between-cases paired ROIs is much larger than the number of within-cases ROIs. We provide estimators for the variance of the between-cases AUC and for the covariance when there are two readers. We derive and prove the above estimators’ theoretical values based on a simulation model and characterize their behavior using Monte Carlo simulation results. We also provide a real-data example. Moreover, we connect the distribution-based simulation model with the simulation model based on the linear mixed-effect model, which helps better understand the sources of variation in the simulated dataset.
Tandem solar cells are not limited to the conventional two-terminal (2-T) configuration. Multi-terminal designs like three-terminal (3-T) and four-terminal (4-T) devices have gained increasing attention in the PV community due to their relaxed current-matching requirement between subcells and their potential for enhanced energy yield. However, reliable and standardized methods for evaluating the performance of multi-terminal tandems remain underdeveloped. This work addresses this gap by providing comprehensive measurement guidelines tailored to these advanced configurations. We examine key coupling mechanisms between subcells, including the shared electrical load in 3-T devices and optical luminescent coupling in both 3-T and 4-T devices, to enable accurate and consistent performance evaluation. Furthermore, we propose two stabilized measurement methods for emerging 3-T tandem cells incorporating perovskite subcells: (1) a two-dimensional maximum-power-point tracking (MPPT) approach that continuously tracks both subcells' maximum power points (P MAX ) until convergence to stabilized outputs, and (2) a hybrid approach that combines MPPT for one subcell with stabilized current recording under fixed voltage biases near the P MAX of the other, allowing robust extraction of the overall stabilized P MAX (termed “MPPT + asymptotic P MA X scan” method). These methods directly address the dynamic current responses inherent to perovskite-containing tandems, providing a foundation for meaningful and reproducible performance comparisons.
Radiolysis of water in nuclear waste storage generates hydrogen gas that can accumulate within sludge style waste and be rapidly released during agitation events, creating a significant flammability hazard. Engineering controls are therefore required to limit hydrogen concentrations during both quiescent storage and transient disturbances. Catalytic recombination of hydrogen in waste storage offgas is a proven mitigation strategy, maintaining hydrogen levels below flammability limits and managing sudden concentration spikes. Conventional recombiners rely on platinum and/or palladium catalysts, with development efforts focused on extending service life, increasing active surface area, and ensuring safe deployment in radioactive environments. Savannah River National Laboratory (SRNL) is evaluating a newly developed hydrogen recombiner catalyst from Canadian Nuclear Laboratories as a cost-effective and durable alternative for nuclear waste applications. Testing was conducted in SRNL’s Shielded Cells facility, which enables reduced-scale experimental modeling under radiation fields and near-use-case conditions relevant to radioactive waste storage. Catalyst performance was evaluated using a custom offgas characterization system designed for near-zero flow conditions. The experimental apparatus consisted of a gas-tight 2.7 L PTFE vessel equipped with temperature monitoring, gas flow controls, and a variable-speed mixer to simulate sludge agitation. Offgas composition was monitored using a dedicated gas chromatograph with argon carrier gas and a krypton internal standard. Measurements were obtained for an empty vessel, the vessel containing a well characterized radioactive tank waste sample, and the same configuration with the candidate catalyst installed. Results demonstrate that the new catalyst effectively reduced hydrogen concentrations in the offgas within the constraints of the experimental design. In addition to confirming catalytic activity, the testing provided valuable insights into experimental optimization and considerations for future performance evaluations. These findings support the potential scalability of the technology and highlight its applicability to broader nuclear waste management operations, offering improved safety and reduced operational costs through enhanced catalyst durability and lower replacement frequency.
Accurate timing estimates of when participants acquire HIV in HIV prevention trials are necessary for determining antibody levels at acquisition. The Antibody-Mediated Prevention (AMP) Studies showed that a passively administered broadly neutralizing antibody can prevent the acquisition of HIV from a neutralization-sensitive virus. We developed a pipeline for estimating the date of detectable HIV acquisition (DDA) in AMP Study participants using diagnostic and viral sequence data. Using a Bayesian strategy that combines three streams of data (REN [rev/vpu/env/Δnef] sequence, GP [gag/Δpol] sequence, and diagnostic) where their 95% credible intervals overlap based on pre-specified criteria and decision rules. We evaluated the performance of our AMP pipeline using PacBio viral sequence data from 41 participants across two prospective acute HIV acquisition cohort studies, FRESH and RV217, with twice-weekly sampling. These cohort studies enrolled young women in South Africa and men and women in Kenya and Thailand, respectively, with a high likelihood of HIV acquisition. In evaluating performance, “true DDA” was the center of bounds between last-negative and first-positive RNA diagnostic tests (median time 4 days, range 2–7 days); bias was the mean difference between estimated and true DDA. Using diagnostic data alone yielded timing estimates with a bias of 2.4 days and root mean square error (RMSE) of 7.9 days. These results were improved using sequence + diagnostic data (bias 1.5 days, RMSE 6.9 days), as well as by restricting sequence-based estimation to samples from ≤5 weeks post-DDA (bias 0.2 days, RMSE 7.8 days).
Numerous efficient semiconductors suffer from instability in aqueous electrolytes. Strategies utilizing protective coatings have thus been developed to protect these photoabsorbers against corrosion while synergistically improving charge separation and reaction kinetics. Recently, various photoelectrochemical (PEC) protective coatings have been reported with suitable electronic properties to ensure low charge transport loss and reveal the fundamental photoabsorber efficiency. However, protocols for studying the critical figures of merit for protective coatings have yet to be established. For this reason, we propose four criteria for evaluating the performance of a protective coating for PEC water-splitting: stability, conductivity, optical transparency, and energetic matching. We then propose a flow chart that summarizes the recommended testing protocols for quantifying these four performance metrics. In particular, we lay out the stepwise testing protocols to evaluate the energetics matching at a semiconductor/coating/(catalyst)/liquid interface. Finally, we provide an outlook for the future benchmarking needs for coatings.
This paper introduces Pandora, a parallel algorithm for computing dendrograms, the hierarchical cluster trees for single linkage clustering (SLC). Current parallel approaches construct dendrograms by partitioning a minimum spanning tree and removing edges. However, they struggle with skewed, hard-to-parallelize real-world dendrograms. Consequently, computing dendrograms is the sequential bottleneck in HDBSCAN*[21], a popular SLC variant. Pandora uses recursive tree contraction to address this limitation. Pandora contracts nodes to construct progressively smaller trees. It computes the smallest contracted dendrogram and expands it by inserting contracted edges. This recursive strategy is highly parallel, skew-independent, work-optimal, and well-suited for GPUs and multicores. We develop a performance portable implementation of Pandora in Kokkos[31] and evaluate its performance on multicore CPUs and multi-vendor GPUs (e.g., Nvidia, AMD) for dendrogram construction in HDBSCAN*. Multithreaded Pandora is 2.2x faster than the current best-multithreaded implementation. Our GPU version achieves 6-20x speedup on AMD GPUs and 10-37x on NVIDIA GPUs over multithreaded Pandora. Pandora removes HDBSCAN*’s sequential bottleneck, greatly boosting efficiency, particularly with GPUs.
Abstract Geologic parameters, geophysical logging, injection testing, and operational metrics from wastewater injection wells were integrated to develop a preliminary design of a carbon storage facility in the Appalachian Basin. A scattered group of 10–20 commercial wastewater injection wells dispose off produced water from oil and gas wells in the region, utilizing a sequence of stacked deep saline formations for injection zones. These wastewater injection wells provide practical benchmarks for understanding the feasibility of carbon dioxide (CO 2 ) storage. Geologic models were developed based on characterization data from the wastewater injection wells. Reservoir simulations were calibrated according to injection testing and operational data from the wastewater injection wells. Long‐term operational data on injection flow rates and pressures measured in the wastewater injection wells were especially useful to evaluate the performance of carbon storage applications. The simulations were used to estimate injection pressures, radius of CO 2 saturation, and pressure response for industrial scale CO 2 storage applications. Results were also used to provide a design basis in terms of number of injection wells, well spacing, area of review, injection system components, monitoring plan, and CO 2 pipeline distribution system. The analysis demonstrates that there is sufficient injectivity in the deep saline formations in the west‐central Appalachian Basin to store commercial volumes of anthropogenic CO 2 . The geologic system appears suitable for supporting CO 2 injection rates of 0.5–1.0 million metric tons per year at injection pressures below formation fracture pressure in a single well. The long‐term operational data of wastewater injection wells within the study area suggested a lower permeability‐thickness values than indicated by initial reservoir tests. A workflow for developing realistic permeability values for input into reservoir simulations is presented. © 2020 Society of Chemical Industry and John Wiley & Sons, Ltd.
The accurate quantification of the performance loss rate of photovoltaic systems is critical for project economics. Following the current research activities in the photovoltaic performance and reliability field, this work presents a comparative assessment between common change point methods for performance loss rate estimation of fielded photovoltaic installations. An extensive testing campaign was thus performed to evaluate time series analysis approaches for performance loss rate evaluation of photovoltaic systems. Historical electrical data from eleven photovoltaic systems installed in Nicosia, Cyprus, and the locations’ meteorological measurements over a period of 8 years were used for this investigation. The application of change point detection algorithms on the constructed monthly photovoltaic performance ratio series revealed that the obtained trend might not always be linear. Specifically, thin film photovoltaic systems showed nonlinear behavior, while nonlinearities were also detected for some crystalline silicon photovoltaic systems. When applying several change point techniques, different numbers and locations of changes were detected, resulting in different performance loss rate values (varying by up to 0.85%/year even for the same number of change points). The results highlighted the importance of the application of nonlinear techniques and the need to extract a robust nonlinear model for detecting significant changes in time series data and estimating accurately the performance loss rate of photovoltaic installations.
Los Alamos National Laboratory (LANL) is a multidisciplinary national laboratory that conducts research and development in national security, engineering, materials science, computational modeling, and advanced manufacturing. The laboratory develops innovative technologies to address complex scientific and engineering challenges. This project focuses on the development and evaluation of high-performance absorbing structures through computational design, simulation, and engineering analysis. Absorbing structures are used in applications where damage mitigation, structural protection, and material efficiency are critical performance requirements. The increasing demand for lightweight, high-strength, and highly efficient structural systems has created a need for improved design methodologies capable of maximizing absorption while minimizing weight and material usage. The project utilizes advanced engineering software, including 3D CAD software and FEA, to generate and optimize structural concepts. Computational simulations are performed to evaluate structural behavior under loading conditions, while mathematical analyses are conducted using Python-based tools as well as established analytical equations from material and structural mechanics. The project benefits LANL by supporting the development of advanced design methodologies and improving the understanding of material and structural performance. During the internship term, a significant portion of the design development, simulation, and data analysis activities will be completed. Success of the project depends on collaboration among engineering mentors and technical staff members. Work will be conducted at Los Alamos National Laboratory using laboratory computing resources and engineering software.