Performance evaluation of electrochemical concentration cell ozonesondes

Laboratory calibrations of more than a hundred electrochemical concentration cell (ECC) ozonesondes were determined relative to UV-photometry. The average intercept and slope, 0 plus or minus 5 nb and 0.96 plus or minus 0.06, respectively, indicate reasonable agreement with UV photometry, but with considerable variation from one ECC ozonesonde to another. The time required to reach 85% of the final reaction to a step-change in ozone concentration was found to average 51 seconds. Application of the individual calibrations to 20 sets of 1976 flight data reduced the average of the differences between ozonesonde and Dobson spectrophotometric measurements of total ozone from 3.9 to 1.3%. A similar treatment of a set of 10 1977 flight records improved the average ECC-Dobson agreement from -8.5 to -1.4%. Although systematic differences were reduced, no significant effect on the random variations was evident.

Torres, A. L.↗

Thermal performance evaluation of Solar Energy Products Company (SEPCO) 'Soloron' collector tested outdoors

The test article, Model EF-212, Serial Nr. 002, is a single glazed collector with a nonselective absorber plate, using flowing air as the heat transfer medium. The absorber plate and box frame are aluminum and the insulation is one inch isocyanurate foam board with thermal conductivity of 0.11 (BTU/sq ft Hr0/ft.) The tests included the following. (1) time constant test, (2) collector efficiency test, (3) collector stagnation test, (4) incident angle modifier test, (5) load test, (6) weathering test, and (7) absorber plate optical properties test. The results of these tests are tabulated, graphed, or otherwise recorded.

Chiou, J., Sr.↗

Indoor test for thermal performance evaluation of Lenox-Honeywell solar collector

The test procedures used and the test results obtained from an evaluation test program conducted on a double-covered liquid solar collector under simulated conditions are presented. The test article was a flat plate solar collector using liquid as the heat transfer medium. The absorber plate was steel with the copper tubes bonded on the upper surface. The plate was coated with black chrome with an absorptivity factor of .95 and emissivity factor of .12. A time constant test and incident angle modifier test were conducted to determine the transient effect and the incident angle effect on the collector.

Shih, K.↗

Design and Performance Evaluation of Slotted Walls for Two-Dimensional Wind Tunnels

A procedure for designing slotted walls for two dimensional wind tunnels is is presented. The design objective is the minimization of blockage of streamline curvature or the reduction of both. The slotted wall boundary condition is derived both for flow from the tunnel into the plenum and vice versa, and the procedure for evaluating wall interference is described. A correlation of experimental data for the slotted wall boundary condition is given. Results are given for several designs and evaluations of slotted wind tunnel walls.

Barnwell, R. W.↗

Indoor test for thermal performance evaluation of Sunworks (liquid) solar collector

Test procedures used and test results obtained from an evaluation test program conducted on a single covered liquid solar collector under simulated conditions are presented. The test article was a flat plate solar collector using water as the heat transfer medium. The absorber plate was copper with copper tubes bonded by soft solder. The plate was coated with Enthone selective black with an absorptivity factor of .87 approximately .92 and an emissivity factor of .10 approximately .20. A time constant test and incident angle modifier test were conducted to determine the transient effect and the incident angle effect on the collector.

Shih, K.↗

Indoor thermal performance evaluation of the SEPCO air collector

The procedures used and the results obtained during the evaluation test program on the Solaron solar air collector, model EF-212, under simulated conditions for comparison with data collected in outdoor tests on the same collector are given. The test article was a single glazed collector with a nonsensitive absorber plate, aluminum box frame, and one inch isocyanurate foam insulation.

Source record↗

Thermal performance evaluation of MSFC hot air collectors with various flow channel depth

The test procedures used and the results obtained during the evaluation test program on the MSFC air collector with flow channel depth of 3 in., 2 in., and 1 in., under simulated conditions are presented. The MSFC hot air collector consists of a single glass cover with a nonselective coating absorber plate and uses air as the heat transfer medium. The absorber panel consists of a thin flat sheet of aluminum.

Source record↗

Electrochemical concentration cell ozonesonde performance evaluation

A large number of electrochemical concentration cell (EDD) ozonesondes were calibrated relative to ultraviolet photometric absorption (254 nm) to determine their precision and accuracy. The average agreement with UV photometry was found to be good, but with considerable variation from one ECC ozonesonde to another. Applying individual calibrations to vertical ozone profiles reduced the systematic differences between ECC ozonesonde total ozone values and Dobson spectrophotometric determinations of the same quantity, but did not improve random differences.

Torres, A. L.↗

Hydrogen-fueled postal vehicle performance evaluation

Fuel consumption, range, and emissions data were obtained while operating a hydrogen-fueled postal delivery vehicle over a defined Postal Service Driving Cycle and the 1975 Urban Driving Cycle. The vehicle's fuel consumption was 0.366 pounds of hydrogen per mile over the postal driving cycle and 0.22 pounds of hydrogen per mile over the urban driving cycle. These data correspond to 6.2 and 10.6 mpg equivalent gasoline mileage for the two driving cycles, respectively. The vehicle's range was 24.2 miles while being operated on the postal driving cycle. Vehicle emissions were measured over the urban driving cycle. HC and CO emissions were quite low, as would be expected. The oxides of nitrogen were found to be 4.86 gm/mi, a value which is well above the current Federal and California standards. Vehicle limitations discussed include excessive engine flashbacks, inadequate acceleration capability the engine air/fuel ratio, the water injection systems, and the cab temperature. Other concerns are safety considerations, iron-titanium hydride observed in the fuel system, evidence of water in the engine rocker cover, and the vehicle maintenance required during the evaluation.

Hall, R. A.↗

Fiber optic rotation sensor /FORS/ laboratory performance evaluation

A single axis rotation sensor, utilizing a 200 m single mode optical fiber in a 30 cm diameter coil has been constructed and tested in the laboratory. A He-Ne laser is the light source for the Sagnac interferometer-mode sensor. The outputs of Si detectors viewing two complementary interference patterns are electronically differenced to obtain a rotation-dependent signal. Linear response over a rotation rate range of about 0.0001 to 0.1 rad/sec was obtained.

Goldstein, R.↗

Performance evaluation of the SAO VLG-11 atomic hydrogen masers

A new generation of frequency standards, the VLG-11 hydrogen maser, has been designed and built at the Smithsonian Astrophysical Observatory (SAO). A comprehensive series of environmental and short-term stability tests on three VLG-11 masers has been completed and evaluated. The test results reported here show substantial improvements over previous hydrogen masers in measured sensitivity to variations in ambient temperature, barometric pressure, and magnetic fields. The maser frequency stability, as represented by the two-sample (Allan) variance, has been measured for averaging times ranging from 1 to 100,00 seconds. The variance is lower than 1 x 10 to the -15th for averaging intervals between 1400 and 20,000 seconds. For times shorter than 4000 seconds, the measured stability data agree remarkably well with theoretical values calculated from thermal noise mechanisms and the 'noise within the linewidth' regime is clearly discernable in the data.

Levine, M. W.↗

Accuracy assessment: The statistical approach to performance evaluation in LACIE

A statistical methodology was developed to check the accuracy of the products of the experimental operations throughout crop growth and to determine whether the procedures are adequate to accomplish the desired accuracy and reliability goals. It has allowed the identification and isolation of key problems in wheat area yield estimation, some of which have been corrected and some of which remain to be resolved. The major unresolved problem in accuracy assessment is that of precisely estimating the bias of the LACIE production estimator. Topics covered include: (1) evaluation techniques; (2) variance and bias estimation for the wheat production estimate; (3) the 90/90 evaluation; (4) comparison of the LACIE estimate with reference standards; and (5) first and second order error source investigations.

Houston, A. G.↗

Performance evaluation of telecommunication systems using computer simulation

The SYSTID time domain digital simulation technique is reviewed. A technique is illustrated which estimates the signal to noise ratio at a point in the simulation of a communication system. Signals having a lowpass or bandpass spectra are utilized. Simulation results show the technique to be accurate over a wide range of signal to noise ratios. Examples which illustrate application to both analog and digital communication systems are provided.

Tranter, W. H.↗

Solar energy system performance evaluation: Seasonal report for Elcam Tempe Arizona State University, Tempe, Arizona

The solar system, Elcam-Tempe, was designed by Elcam Incorporated, Santa Barbara, California, to supply commercial domestic hot water heating systems to the Agriculture Department residence at Arizona State University. The building is a single story residence located at the agriculture experiment farm of the Arizona State University. The energy system's four modes of operation are described. Electrical energy savings at the site was a net of 5.54 million Btu after the 0.17 million Btu of operating energy required to operate collector loop circulating pump were subtracted. The energy savings due to solar was less than the system's potential. On an average, twice as much hot water could have been used with significant solar energy contribution. The system corrosion and deposits caused by using dissimilar metals in the collector loop was the only problem noted with the Elcam-Tempe system.

Source record↗