Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Performance Rating Method”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Analysis of PNAR Spent Fuel Safeguards Measurements using the ORIGEN Data Analysis Module

This paper summarizes the analysis of the Passive Neutron Albedo Reactivity (PNAR) measurements using the ORIGEN data analysis module for 23 boiling water reactor spent fuel assemblies that were performed in Finland under an international collaboration on spent fuel safeguards verification methods. PNAR is part of the proposed integrated nondestructive system to be used for safeguards verifications at the planned Finnish encapsulation facility. Besides measuring passive neutron and gamma emission rates from an assembly like a Fork detector, PNAR also measures the PNAR ratio, which is expected to correlate with the fissile content in the assembly. The emission rates and PNAR ratio can be used to verify the operator declarations and the fissile content of an assembly, respectively. The analysis was performed using the ORIGEN Data Analysis Module, which was originally developed for predicting Fork detector neutron and gamma signals for spent fuel measurements and has been integrated into the Integrated Review and Analysis Package developed by Euratom and the IAEA. The Module includes the ORIGEN burnup analysis code and integrates detector response functions pre-generated using MCNP to predict detector signals in several seconds per assembly. In this study, new response functions specific to PNAR measurements were generated for ORIGEN Module. The study also analyzes impacts of using detailed fuel design and operation information vs. standard safeguards information on results calculated by ORIGEN Module. Using detailed information reduced the standard deviation of relative differences between calculated and measured neutron count rates among the 23 assemblies from ~10% to ~4%. The results obtained using standard safeguards information for these PNAR measurements were similar to those obtained for the Fork detector. A clear trend was found between the calculated net neutron multiplications and the measured PNAR ratios of the 23 assemblies. This paper describes how ORIGEN Module calculates the expected PNAR neutron and gamma signals and PNAR ratio and how they compare with corresponding measured values.

Ilas, Germina↗

Nonintrusive Uncertainty Quantification of Computational Fluid Dynamics Simulations of a Bench-Scale Fluidized-Bed Gasifier

Uncertainty quantification (UQ) analysis is increasingly becoming one of the major requirements of simulation-based engineering to assess the confidence in the results and make better-informed decisions based on the insight derived from the simulations. In an earlier study, Bayesian UQ analysis was applied to existing bench-scale fluidized-bed gasifier experiment results. In the current study, a series of simulations were carried over with the open-source computational fluid dynamics software MFiX to reproduce the experimental conditions, where three operating factors, i.e., coal flow rate, coal particle diameter, and steam-to-oxygen ratio, were systematically varied to understand their effect on the syngas composition. Bayesian UQ analysis was this time performed on the numerical results for comparison purposes. This is part of ongoing research efforts to explore the applicability of advanced UQ methods and processes such as Bayesian methods for large-scale complex multiphase flow simulations. As part of Bayesian UQ analysis, a global sensitivity analysis was performed based on the simulation results, which shows that the predicted syngas composition is strongly affected not only by the steam-to-oxygen ratio (which was observed in experiments as well) but also by variation in the coal flow rate and particle diameter (which was not observed in experiments). The carbon monoxide mole fraction is underpredicted at lower steam-to-oxygen ratios and overpredicted at higher steam-to-oxygen ratios. The opposite trend is observed for the carbon dioxide mole fraction. These discrepancies are attributed to either excessive segregation of the phases that leads to the fuel-rich or -lean regions or alternatively the selection of reaction models, where different reaction models and kinetics can lead to different syngas compositions throughout the gasifier.

01 COAL, LIGNITE, AND PEAT↗

Comparison of methods for the measurement of radiation dose distributions in high dose rate (HDR) brachytherapy: Ge-doped optical fiber, EBT3 Gafchromic film, and PRESAGE{sup Registered-Sign} radiochromic plastic

Purpose: Dose distribution measurement in clinical high dose rate (HDR) brachytherapy is challenging, because of the high dose gradients, large dose variations, and small scale, but it is essential to verify accurate treatment planning and treatment equipment performance. The authors compare and evaluate three dosimetry systems for potential use in brachytherapy dose distribution measurement: Ge-doped optical fibers, EBT3 Gafchromic film with multichannel analysis, and the radiochromic material PRESAGE{sup Registered-Sign} with optical-CT readout. Methods: Ge-doped SiO{sub 2} fibers with 6 {mu}m active core and 5.0 mm length were sensitivity-batched and their thermoluminescent properties used via conventional heating and annealing cycles. EBT3 Gafchromic film of 30 {mu}m active thickness was calibrated in three color channels using a nominal 6 MV linear accelerator. A 48-bit transmission scanner and advanced multichannel analysis method were utilized to derive dose measurements. Samples of the solid radiochromic polymer PRESAGE{sup Registered-Sign }, 60 mm diameter and 100 mm height, were analyzed with a parallel beam optical CT scanner. Each dosimetry system was used to measure the dose as a function of radial distance from a Co-60 HDR source, with results compared to Monte Carlo TG-43 model data. Each system was then used to measure the dose distribution along one or more lines through typical clinical dose distributions for cervix brachytherapy, with results compared to treatment planning system (TPS) calculations. Purpose-designed test objects constructed of Solid Water and held within a full-scatter water tank were utilized. Results: All three dosimetry systems reproduced the general shape of the isolated source radial dose function and the TPS dose distribution. However, the dynamic range of EBT3 exceeded those of doped optical fibers and PRESAGE{sup Registered-Sign }, and the latter two suffered from unacceptable noise and artifact. For the experimental conditions used in this study, the useful range from an isolated HDR source was 5-40 mm for fibers, 3-50 mm for EBT3, and 4-21 mm for PRESAGE{sup Registered-Sign }. Fibers demonstrated some over-response at very low dose levels, suffered from volume averaging effects in the dose distribution measurement, and exhibited up to 9% repeatability variation over three repeated measurements. EBT3 demonstrated excellent agreement with Monte Carlo and TPS dose distributions, with up to 3% repeatability over three measurements. PRESAGE{sup Registered-Sign} gave promising results, being the only true 3D dosimeter, but artifacts and noise were apparent. Conclusions: The comparative response of three emerging dosimetry systems for clinical brachytherapy dose distribution measurement has been investigated. Ge-doped optical fibers have excellent spatial resolution for single-direction measurement but are currently too large for complex dose distribution assessment. The use of PRESAGE{sup Registered-Sign} with optical-CT readout gave promising results in the measurement of true 3D dose distributions but further development work is required to reduce noise and improve dynamic range for brachytherapy dose distribution measurements. EBT3 Gafchromic film with multichannel analysis demonstrated accurate and reproducible measurement of dose distributions in HDR brachytherapy. Calibrated dose measurements were possible with agreement within 1.5% of TPS dose calculations. The suitability of EBT3 as a dosimeter for 2D quality control or commissioning work has been demonstrated.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Fast Deposition of Aligning Edge‐On Polymers for High‐Mobility Ambipolar Transistors

Abstract Fast deposition of aligning ambipolar polymers for high‐performance organic field‐effect transistors (OFETs) and inverter circuits are highly desired for both scientific studies and industry applications. Here, large‐area and ordered polymer films are prepared by a bar‐coating method at a rate of 120 mm s −1 in air. Atomic force microscopy and grazing‐incidence wide‐angle X‐ray scattering analysis indicate uniform edge‐on poly(fluoroisoindigo‐difluorobithiophene‐fluoroisoindigo‐bithiophene) (PFIBI‐BT) in 11.7 ± 1 nm film (≈5 layers). The elongated, uniformly oriented grains can reduce the adverse effects of the grain boundaries and facilitate charge transport in polymers. Furthermore, OFETs based on parallel film show high hole/electron mobilities up to 5.5/4.5 cm 2 V −1 s −1 , which are approximately nine times of the devices prepared by spin‐coating. The gain of the inverter is as high as 174, which is one of the highest values in polymer inventers currently. These results demonstrate that the excellent bipolar performance of few‐layer PFIBI‐BT can be ensured while achieving the compatibility of the experimental process with industrial preparation.

Jiang, Yingying↗

Structural and Electrochemical Characterization of Thin Film Li 2 MoO 3 Electrodes

We report that Li 2 MoO 3 is a promising structural stabilizing unit for use in composite layered-layered cathodes for Li-ion batteries. To enable the rational design of such cathodes, studies on fundamental phenomena related to the active material structure and electrode/electrolyte interface are needed. The present work details the fabrication and characterization of thin film Li 2 MoO 3 cathodes and shows that their electrochemical performance greatly depends on the nature of the cathode/electrolyte interface. The Li 2 MoO 3 thin films exhibit poor cyclability in a liquid carbonate electrolyte (e.g., initial capacity of 166 mAh/g with 40% capacity fade over 20 cycles) whereas all-solid-state Li 2 MoO 3 /Lipon/Li batteries show negligible fade during cycling. A suite of characterization methods including Raman spectroscopy and X-ray photoelectron spectroscopy are used to study the evolution of the cathode structure and cathode electrolyte interphase (CEI) layer during charge/discharge cycling. Li transport rates are another important factor which affect cathode performance. AC impedance spectroscopy studies reveal that the Li diffusion coefficient (D Li ) in Li 2 MoO 3 decreases from 4.36 × 10 -11 cm 2 /s in the fully discharged state to 4.51 × 10 -13 cm 2 /s when charged to 3.6 V vs. Li/Li + . In conclusion, the results presented herein provide insight on the fundamental phenomena which govern Li 2 MoO 3 cathode performance.

25 ENERGY STORAGE↗

Magnetic Resonance–Based Automatic Air Segmentation for Generation of Synthetic Computed Tomography Scans in the Head Region

Purpose: To incorporate a novel imaging sequence for robust air and tissue segmentation using ultrashort echo time (UTE) phase images and to implement an innovative synthetic CT (synCT) solution as a first step toward MR-only radiation therapy treatment planning for brain cancer. Methods and Materials: Ten brain cancer patients were scanned with a UTE/Dixon sequence and other clinical sequences on a 1.0 T open magnet with simulation capabilities. Bone-enhanced images were generated from a weighted combination of water/fat maps derived from Dixon images and inverted UTE images. Automated air segmentation was performed using unwrapped UTE phase maps. Segmentation accuracy was assessed by calculating segmentation errors (true-positive rate, false-positive rate, and Dice similarity indices using CT simulation (CT-SIM) as ground truth. The synCTs were generated using a voxel-based, weighted summation method incorporating T2, fluid attenuated inversion recovery (FLAIR), UTE1, and bone-enhanced images. Mean absolute error (MAE) characterized Hounsfield unit (HU) differences between synCT and CT-SIM. A dosimetry study was conducted, and differences were quantified using γ-analysis and dose-volume histogram analysis. Results: On average, true-positive rate and false-positive rate for the CT and MR-derived air masks were 80.8% ± 5.5% and 25.7% ± 6.9%, respectively. Dice similarity indices values were 0.78 ± 0.04 (range, 0.70-0.83). Full field of view MAE between synCT and CT-SIM was 147.5 ± 8.3 HU (range, 138.3-166.2 HU), with the largest errors occurring at bone–air interfaces (MAE 422.5 ± 33.4 HU for bone and 294.53 ± 90.56 HU for air). Gamma analysis revealed pass rates of 99.4% ± 0.04%, with acceptable treatment plan quality for the cohort. Conclusions: A hybrid MRI phase/magnitude UTE image processing technique was introduced that significantly improved bone and air contrast in MRI. Segmented air masks and bone-enhanced images were integrated into our synCT pipeline for brain, and results agreed well with clinical CTs, thereby supporting MR-only radiation therapy treatment planning in the brain.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A practical approach for identifying various polarization behaviors of redox-stable electrodes in symmetrical solid oxide fuel cells

In symmetrical solid oxide fuel cells, comprehensively understanding the elementary reaction processes and the polarization behaviors of redox-stable electrode materials is critical for further optimization of the electrode performance. In this work, a systematical and practical approach, based on electrochemical impedance spectroscopy technology, is applied to identify the rate-limiting elementary reactions of the redox-stable electrodes. The feasibility of this proposed method is demonstrated in symmetrical solid oxide fuel cells with Sr 2 Fe 1.5 Mo 0.5 O 6-σ -Ce 0.9 Gd 0.1 O 1.95 as electrodes. Based on the characteristic frequency ranges and the experimental results tested under various fuel gas components, operating temperatures, and discharge current densities, the rate-limiting steps of the cathode are associated with the formation of adsorbed oxygen ions and the combination of oxygen ions and oxygen vacancies, while the rate-limiting steps of the anode are ascribed to the hydrogen dissociated adsorption and the steam desorption processes. This experimental and analysis framework can be straightforwardly extended to other electrode materials to unravel their electrochemical performance in detail.

25 ENERGY STORAGE↗

High-Performance Low-Cobalt Cathode Materials for Li-ion Batteries

The layer-structured Li[Ni x Co y Mn 1-x-y ]O 2 (NCM) cathode materials have been the best choice for increasing electric vehicle driving distance per charge. The high Ni layered oxide represents successfully commercialized NCM cathodes (such as NCM622 and NCA) in lithium-ion batteries (LIBs) for EV applications due to their high energy density and acceptable cycling stability. However, the price of cobalt, the key element within LIBs for stability, has nearly tripled over the past few years due to increased demand from the cell phone industry. As mentioned in the DOE Funding Opportunity Announcement, the current materials shortage will also cause speculation for a future global shortage. Therefore, to meet the requirement and sustainability of the next-generation long-range and low-cost EVs, developing cathode materials with low-Co content to achieve higher energy density and lower cost is both essential and urgent. The overarching objective of this work is to develop stabilized NCM cathode materials with low Co content (namely LiNi x Co y Mn 1-x-y O 2 , y ≤ 0.04) to meet DOE’s goal of reducing Co loading below 50 mg Wh -1 while maintaining energy density greater than 600 Wh kg -1 based on cathode material. Via various dopings and coatings scalable methods, we explored and enhanced the cycling performance of low-cobalt cathodes. The final obtained NCM cathodes paired with graphite anode aim to deliver batteries with a high initial specific energy density of over 240 Wh kg -1 and a low capacity fading rate of less than 20% in 1000 cycles under a C/3 discharge rate. To accomplish this goal, a multidisciplinary team with several co-investigators has been formed from three organizations: The Pennsylvania State University (PSU), Oak Ridge National Laboratory (ORNL), and Pacific Northwest National Laboratory (PNNL). The PI and co-investigators are Dr. Donghai Wang (PI) from PSU with expertise in the synthesis of nanostructured materials and manipulation of interfacial properties of electrochemically active materials, Dr. Jagjit Nanda, with substantial knowledge of and expertise in state-of-the-art cathodes from ORNL, Dr. Chao-Yang Wang with significant experience in advanced cell design and fabrication and cell diagnostics from PSU, and Dr. Chongmin Wang with world-wide known expertise of advance atomic scale characterization of electrode materials from PNNL. Furthermore, this project will leverage and synergistically work with the current DOE-funded programs on battery materials at PSU and ORNL and electrode materials characterization at PNNL. During this funded period, we have accomplished milestones stated as follows: • Scale up production of LiFePO 4 (LFP) coated NCM811 with a production of 300g/batch. Fifteen (≥2 Ah) pouch cells with LFP-coated NCM811 cathode are delivered. Self-evaluated pouch cells in PSU show superior over 80% capacity retention performance even after 1500 cycles at C/3 rate. • Various cations (Al, Ti, Zr, and Mo) substitute cobalt in low-cobalt partially and Co-free cathodes. Their effects on crystal structure and electrochemical behavior are explored. • Phosphate compounds as coating materials represent promising surface protection precursors for low-cobalt cathode materials. Therefore, several metal phosphates were selected for improving the NMC cycling performance and are regarded as effective approaches for a scalable and practical surface protection method. • Production of NCM92, where Nickel content is 92% among transition metals, is scaled up from synthesis to coating and heat treatment procedures. Fifteen 2.7Ah pouch cells with Ti-doped NCM92 cathodes and industrial graphite anode are delivered to Idaho National Lab for testing.

25 ENERGY STORAGE↗

A Facile, Low-Cost Hot-Pressing Process for Fabricating Lithium-Sulfur Cells with Stable Dynamic and Static Electrochemistry

Lithium–sulfur batteries are among the most promising low-cost, high-energy-density storage devices. However, the inability to host a sufficient amount of sulfur in the cathode while maintaining good electrochemical stability under a lean electrolyte condition has limited the progress. The main cause of these challenges is the sensitivity of the sulfur cathode to the cell-design parameters (i.e., the amount of sulfur and electrolyte) and the experimental testing conditions (i.e., cycling rates and analysis duration). Here, a hot-pressing method is presented that effectively encapsulates a high amount of sulfur in the cathode within only 5 s, resulting in high sulfur loading and content of, respectively, 10 mg cm -2 and 65 wt%. The hot-pressed sulfur (HPS) cathodes exhibit superior dynamic and static electrochemical performance under a broad cycling-rate (C/20–1C rates) and low electrolyte/sulfur ratio (6 µL mg -1 ) conditions. The dynamic cell stability is demonstrated by high gravimetric and areal capacities of, respectively, 415–730 mAh g -1 and 7–12 mAh cm -2 at C/20–1C rates with a high capacity retention of over 70% after 200 cycles. As a result, the static cell stability is demonstrated by excellent shelf life with low self-discharge and stable cycle life on storing for over one year.

25 ENERGY STORAGE↗

Radiation Resistance of XLPE Nano-dielectrics for Advanced Reactor Applications

Recently there has been renewed interest in nuclear reactor safety, particularly as commercial reactors are approaching 40 years service and lifetime extensions are considered, as well as for new reactor building projects around the world. The materials that are currently used in cabling for instrumentation, reactor control, and communications include cross-linked polyethylene (XLPE), ethylene propylene rubber (EPR), polyvinyl chloride (PVC), neoprene, and chlorosulfonated polyethylene. While these materials show suitable radiation tolerance in laboratory tests, failures before their useful lifetime occur due to the combined environmental effects of radiation, temperature and moisture, or operation under abnormal conditions. In addition, the extended use of commercial reactors beyond their original service life places a greater demand on insulating materials to perform beyond their current ratings in these nuclear environments. Nanocomposite materials that are based on XLPE and other epoxy resins incorporating TiO2, MgO, SiO2, and Al2O3 nanoparticles are being fabricated using a novel in-situ method established at ORNL to demonstrate materials with increased resistance to radiation. As novel nanocomposite dielectric materials are developed, characterization of the non-irradiated and irradiated nanodielectrics will lead to a knowledge base that allow for dielectric materials to be engineered with specific nanoparticle additions for maximum benefit to wide-variety of radiation environments found in nuclear reactors. This paper presents the initial findings on the development of XLPE-based SiO2 nano-composite dielectrics in the context of electrical performance and radiation degradation.

dielectrics↗

VERA and VERA-EDU 3.5 Release Notes

The Virtual Environment for Reactor Applications components included in this distribution include selected computational tools and supporting infrastructure that solve neutronics, thermal-hydraulics, fuel performance, and coupled neutronics-thermal hydraulics problems. The infrastructure components provide a simplified common user input capability and provide for the physics integration with data transfer and coupled-physics iterative solution algorithms. Neutronics analysis can be performed for 2D lattices, 2D core and 3D core problems for pressurized water reactor geometries that can be used to calculate criticality and fission rate distributions by pin for input fuel compositions. MPACT uses the Method of Characteristics transport approach for 2D problems. For 3D problems, MPACT uses the 2D/1D method which uses 2D MOC in a radial plane and diffusion or SPn in the axial direction. MPACT includes integrated cross section capabilities that provide problem-specific cross sections generated using the subgroup methodology. The code can be executed both 2D and 3D problems in parallel to reduce overall run time. A thermal-hydraulics capability is provided with CTF (an updated version of COBRA-TF) that allows thermal-hydraulics analyses for single and multiple assemblies using the simplified VERA common input. This distribution also includes coupled neutronics/thermal-hydraulics capabilities to allow calculations using MPACT coupled with CTF. The VERA fuel rod performance component BISON calculates, on a 2D or 3D basis, fuel rod temperature, fuel rod internal pressure, free gas volume, clad integrity and fuel rod waterside diameter. These capabilities allow simulation of power cycling, fuel conditioning and deconditioning, high burnup performance, power uprate scoping studies, and accident performance. Input/Output capabilities include the VERA Common Input (VERAIn) script which converts the ASCII common input file to the intermediate XML used to drive all of the physics codes in the VERA Core Simulator (VERA-CS). VERA component codes either input the VERA XML format directly, or provide a preprocessor which can convert the XML into native input. VERAView is an interactive graphical interface for the visualization and engineering analyses of output data from VERA. The python-based software is easy to install and intuitive to use, and provides instantaneous 2D and 3D images, 1D plots, and alpha-numeric data from VERA multi-physics simulations. Testing within CASL has focused primarily on Westinghouse four-loop reactor geometries and conditions with example problems included in the distribution.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

The SCALE/AMPX multigroup cross section processing for fast reactor analysis

The SCALE/AMPX multigroup (MG) cross section processing procedure has been updated to minimize reactivity differences for fast reactor designs and boiling water reactors (BWRs) with very high void fractions to provide excellent agreement with continuous-energy reference calculations. SCALE MG calculations are widely applied to thermal spectrum light-water reactor (LWR) systems as well as fast spectrum metallic systems of interest to National Nuclear Security Administration. With growing interest from industry and regulators in applying SCALE for the design of fast spectrum reactors, both sodium and molten salt, and in the licensing of power up rates for BWRs, it is desirable to review the SCALE/AMPX procedure for unresolved resonance self-shielded data and high energy neutron spectra. The data were improved by generating MG unresolved resonance data based on the analytic probability table method with the narrow resonance approximation as well as the use of a very fine group structure typically used in fast system analysis. This study focused on verifying the probability table and the SCALE/AMPX MG cross section processing procedure by performing reaction rate analysis and benchmark calculations for various fast reactor and high void BWR systems. Here, results indicate that the improved SCALE/AMPX MG cross section processing provides excellent results for the fast reactor analysis.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Comparing field and lab quantitative stable isotope probing for nitrogen assimilation in soil microbes

ABSTRACT Soil microbial communities play crucial roles in nutrient cycling and can help retain nitrogen in agricultural soils. Quantitative stable isotope probing (qSIP) is a useful method for investigating taxon-specific microbial growth and utilization of specific nutrients, such as nitrogen (N). Typically, qSIP is performed in a highly controlled lab setting, so the field relevance of lab qSIP studies remains unknown. We conducted and compared tandem lab and field qSIP to quantify the assimilation of 15 N by maize-associated soil prokaryotic communities at two agricultural sites. Here, we show that field qSIP with 15 N can be used to measure taxon-specific microbial N assimilation. Relative 15 N assimilation rates were generally lower in the field, and the magnitude of this difference varied by site. Rates differed by method (lab vs field) for 19% of the top N assimilating genera. The field and lab measures were more comparable when relative assimilation rates were weighted by relative abundance to estimate the proportion of N assimilated by each genus with only ~10% of taxa differing by method. Of those that differed, the taxa consistently higher in the lab were inclined to have opportunistic lifestyle strategies, whereas those higher in the field had niches reliant on plant roots or in-tact soil structure (biofilms, mycelia). This study demonstrates that 15 N-qSIP can be successfully performed using field-incubated soils to identify microbial allies in N retention and highlights the strengths and limitations of field and lab qSIP approaches. IMPORTANCE Soil microbes are responsible for critical biogeochemical processes in natural and agricultural ecosystems. Despite their importance, the functional traits of most soil organisms remain woefully under-characterized, limiting our ability to understand how microbial populations influence the transformation of elements such as nitrogen (N) in soil. Quantitative stable isotope probing (qSIP) is a powerful tool to measure the traits of individual taxa. This method has rarely been applied in the field or with 15 N to measure nitrogen assimilation. In this study, we measured genus-specific microbial nitrogen assimilation in two agricultural soils and compared field and lab 15 N qSIP methods. Our results identify taxa important for nitrogen assimilation in agricultural soils, shed light on the field relevance of lab qSIP studies, and provide guidance for the future application of qSIP to measure microbial traits in the field.

Reed, Kinsey (ORCID:0000000155178664)↗

Investigation of In Situ and Ex Situ Passivation of Pyrophoric Uranium–Niobium Alloy Powder

This work evaluates the effectiveness of in situ and ex situ passivation methods for mitigating the pyrophoricity of uranium–6 wt.% niobium spherical powders produced via the hydride–dehydride process coupled with plasma spheroidization. Oxide layer thickness was characterized using STEM/EDX, and pyrophoricity was assessed by a UN-recommended test method, which involves directly dropping the powders in the air. In situ passivation, performed by introducing flowing oxygen during spheroidization, produced oxide layers ranging from tens to hundreds of nanometers but resulted in inconsistent pyrophoricity mitigation at lower oxygen flow rates. Ex situ passivation, achieved by slow oxygen exposure over several months, formed uniform oxide layers of approximately 20 nm and consistently mitigated pyrophoricity. Despite requiring higher bulk oxygen content, in situ passivation enables faster processing and control of oxygen, while ex situ passivation achieves superior oxide uniformity with lower oxygen incorporation. These findings highlight the trade-offs between passivation methods and provide a foundation for improving the safety and scalability of reactive metal powder production.

U-6Nb↗

Delayed Gamma-Ray Spectroscopy for Non-Destructive Assay of Nuclear Materials

High-­energy, beta-delayed gamma-­ray spectroscopy is a potential, non-­destructive assay techniques for the independent verification of declared quantities of special nuclear materials at key stages of the fuel cycle and for directly assaying nuclear material inventories for spent fuel handling, interim storage, reprocessing facilities, repository sites, and final disposal. Other potential applications include determination of MOX fuel composition, characterization of nuclear waste packages, and challenges in homeland security and arms control verification. Experimental measurements were performed to evaluate fission fragment yields, to test methods for determining isotopic fractions, and to benchmark the modeling code package. Experimental measurement campaigns were carried out at the IAC using a photo-­neutron source and at OSU using a thermal neutron beam from the TRIGA reactor to characterize the emission of high-­energy delayed gamma rays from 235 U, 239 Pu, and 241 Pu targets following neutron induced fission. Data were collected for pure and combined targets for several irradiation/spectroscopy cycle times ranging from 10/10 seconds to 15/30 minutes.The delayed gamma-ray signature of 241 Pu, a significant fissile constituent in spent fuel, was measured and compared to 239 Pu. The 241 Pu/ 239 Pu ratios varied between 0.5 and 1.2 for ten prominent lines in the 2700-­3600 keV energy range. Such significant differences in relative peak intensities make it possible to determine relative fractions of these isotopes in a mixed sample. A method for determining fission product yields by fitting the energy and time dependence of the delayed gamma-­ray emission was developed and demonstrated on a limited 235 U data set. De-­convolution methods for determining fissile fractions were developed and tested on the experimental data. The use of high count-­rate LaBr 3 detectors was investigated as a potential alternative to HPGe detectors. Modeling capabilities were added to an existing framework and codes were adapted as needed for analyzing experiments and assessing application-­specific assay concepts. A de-­convolution analysis of the delayed gamma-­ray response spectra modeled for spent fuel assemblies was performed using the same method that was applied to the experimental spectra.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Incidence of atrioventricular block with vasodilator stress SPECT: A meta-analysis

Background: Adenosine or regadenoson are often used with pharmacologic stress testing. Adenosine may trigger atrioventricular block (AVB). Despite its higher selectivity, regadenoson has also been associated with AVB. We studied the incidence of de novo AVB with these agents. Methods: A comprehensive search of SCOPUS was performed from inception to March 2016. Studies of at least 10 patients, using adenosine and/or regadenoson with SPECT-MPI, reporting rates of AVB were selected for further review. Results: Thirty four studies were pooled including 22,957 patients. Adenosine was used in 21 studies and regadenoson in 15. Both were administered in two studies. The estimated incidence of overall and high-grade AVB was 3.81% (95% CI 1.99%-6.19%) and 1.93% (95% CI 0.77%-3.59%), respectively. The incidence of AVB (8.58%; 95% CI 5.55%-12.21% vs 0.30%; 95% CI 0.04%-0.82%, respectively, P < .001) and high-grade AVB (5.21%; 95% CI 2.81%-8.30% vs 0.05%; 95% CI < .001%-0.19% respectively, P < .001) were higher with adenosine compared to regadenoson. Conclusion: AVB is seen in about 4% of patients undergoing vasodilator stress test. Both overall and high-grade AVB are more frequent with adenosine compared to regadenoson.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Exploring strain rate effects upon 3D materials using high speed in situ X-ray tomoscopy

Cellular materials are ubiquitous in our modern society. They may be stochastic gas-blown foams (e.g., polyurethane), foamed starches (e.g., cereals), or, in this case, 3D printed microlattices. Failure in these materials is often driven by surface or sub-surface defects, which may be nucleated at a surface roughness, an interior void, or inclusion interfaces that may not be typically observable. Obfuscating our understanding further, bulk materials are known to exhibit strain-rate-dependent mechanical response, making a subsurface understanding of damage even more critical. For the first time, an in situ uniaxial mechanical loading stage that simultaneously rotates specimens up to 18 Hz was fielded at a synchrotron for 3D tomographic imaging. This capability opens a plethora of materials science opportunities to explore strain rate effects in materials and examining deformation, fracture, and delamination’s (in composites) for a complete 3D picture (movie) of material response. We demonstrate the deformation of 3D printed polymer lattice structures, of three different material types, at 0.25, 1.1, and 2.2 s −1 strain rates. We successfully imaged the 3D deformation of these materials and can directly compare the same printed structure to the three material types at three strain rates, all in 3D. Material point method simulations were applied to one of the materials to better understand the role of voids on the 3D printed structure’s performance.

36 MATERIALS SCIENCE↗