Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Particle accelerator sciences”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Silicon Micromachines for Science and Technology

The era of silicon micromechanics is upon us. In areas as diverse as telecommunications, automotive, aerospace, chemistry, entertainment and basic science, the ability to build microscopic machines from silicon is having a revolutionary impact. In my talk, I will discuss what micromachines are, how they are built and show examples of how they will have a revolutionary impact in many areas of science as well as technology.

43 PARTICLE ACCELERATORS↗

Graduate Student Program in Materials and Engineering Research and Development for Future Accelerators

The objective of the proposal was to develop graduate student training in materials and engineering research relevant to the development of particle accelerators. Many components used in today's accelerators or storage rings are at the limit of performance. The path forward in many cases requires the development of new materials or fabrication techniques, or a novel engineering approach. Often, accelerator-based laboratories find it difficult to get top-level engineers or materials experts with the motivation to work on these problems. The three years of funding provided by this grant was used to support development of accelerator components through a multidisciplinary approach that cut across the disciplinary boundaries of accelerator physics, materials science, and surface chemistry. The following results were achieved: (1) significant scientific results on fabrication of novel photocathodes, (2) application of surface science and superconducting materials expertise to accelerator problems through faculty involvement, (3) development of instrumentation for fabrication and characterization of materials for accelerator components, (4) student involvement with problems at the interface of material science and accelerator physics.

43 PARTICLE ACCELERATORS↗

Effects of electron beam irradiation on CrMnV and CrMnTiV high entropy alloys: Nano-mechanical, structural, and thermodynamic perspectives

Beam exit windows are crucial components of any particle accelerator as they provide an interface between the beamline vacuum and target material at atmospheric media. For high beam power machines, special materials and designs are required to withstand high radiation and mechanical loads, while minimizing energy loss during transition and maximizing window lifetime. This research investigates the impact of electron beam exposure to bulk CrMnV and CrMnTiV high entropy alloys (HEAs) with the primary goal of identifying suitable candidate materials for the design of robust and durable exit window settings. The selection criteria include intrinsic characteristics, power dissipation, and mechanical responses. According to the thermodynamic calculations, both equiatomic CrMnV and the addition of 7% of Ti with equiatomic CrMnV yield solid-solutions phases. The structural and mechanical properties of CrMnV and CrMnTiV samples were tested using field emission scanning electron microscopy, atomic force microscopy, scanning electron microcopy with energy dispersive x-ray spectroscopy, x-ray diffraction, and nanoindentation before and after exposure to a dose of ~66 kGy from a 10 MeV e-beam accelerator. Despite exhibiting beam transmission characteristics comparable to Cr and V, the indentation hardness of HEAs exceeded that of the Cr and V samples by five to six times. The examination of the CrMnTiV irradiated samples revealed organized deformation patterns depicting new features, which we suspect twinning and twin boundaries due to the addition of Ti to CrMnV. Ti, a hexagonal-close-packed crystal structure, is commonly known for deformation twinning behavior.

36 MATERIALS SCIENCE↗

Science and Technology Review October/November 2011

At Lawrence Livermore National Laboratory, we focus on science and technology research to ensure our nation’s security. We also apply that expertise to solve other important national problems in energy, bioscience, and the environment. Science & Technology Review is published eight times a year to communicate, to a broad audience, the Laboratory’s scientific and technological accomplishments in fulfilling its primary missions. The publication’s goal is to help readers understand these accomplishments and appreciate their value to the individual citizen, the nation, and the world. This is the October/November 2011 issue, with the cover story being "Proton Therapy Advances Cancer Treatment."

43 PARTICLE ACCELERATORS↗

The Klynac: An integrated klystron and linear accelerator

The Klynac concept integrates an electron gun, a radio frequency (RF) power source, and a coupled-cavity linear accelerator into a single resonant system. The klystron is essentially a conventional klystron structure with an input cavity, some number of intermediate cavities and an output cavity. The accelerator structure is, likewise, a conventional on-axis coupled structure. The uniqueness is the means of coupling the klystron output cavity to the accelerator. The coupler is a resonant coupler rather than an ordinary transmission line. The geometry of such a system need not be coaxial. However, if the klystron and accelerator are coaxial we can eliminate the need for a separate cathode for the accelerator by injecting some of the klystron beam into the accelerator. Such a device can be made cylindrical which is ideal for some applications.

43 PARTICLE ACCELERATORS↗

New Structural Biology Facilities at NSLS-II

The National Synchrotron Light Source II (NSLS-II), a Department of Energy (DOE) Office of Science User Facility located at Brookhaven National Laboratory offers an advanced suite of beamlines dedicated to structural biology research for investigating problems ranging from the atomic to the cellular scale. The beamlines are now available for general users, while adjacent wet and dry laboratories will become available soon. These beamlines offer X-ray diffraction, scattering, footprinting, spectroscopy, and imaging techniques that capitalize on NSLS-II's brightness.

43 PARTICLE ACCELERATORS↗

First Principles Modeling of RFQ Cooling System and Resonant Frequency Responses for Fermilab’s PIP-II Injector Test

In this study we develop an a priori method for simulating dynamic resonant frequency and temperature responses in a radio frequency quadrupole (RFQ) and its associated water-based cooling system respectively. Our model provides a computationally efficient means to evaluate the transient response of the RFQ over a large range of system parameters. The model was constructed prior to the delivery of the PIP-II Injector Test RFQ and was used to aid in the design of the water-based cooling system, data acquisition system, and resonance control system. Now that the model has been validated with experimental data, it can confidently be used to aid in the design of future RFQ resonance controllers and their associated water-based cooling systems. Finally, without any empirical fitting, it has demonstrated the ability to predict absolute temperature and frequency changes to 11% accuracy on average, and relative changes to 7% accuracy.

43 PARTICLE ACCELERATORS↗

Optical stochastic cooling at Fermilab’s IOTA ring

Stochastic cooling (SC) constitutes one of the greatest conceptual and technological achievements in particle beam cooling. Numerous SC systems have been built in the microwave regime and used to extend the science reach of accelerator facilities worldwide. The ability to sense and correct the particle ensemble using high-bandwidth feedback systems is at the core of the concept. Here, we describe the first realization of SC at optical frequencies and bandwidths. The demonstration was recently carried out at Fermilab’s integrable optics test accelerator (IOTA) storage ring using the transit-time method of optical stochastic cooling (OSC) and achieved an integrated system bandwidth of approximately 20 THz, which is more than 2000 times that of conventional SC systems. This demonstration establishes the foundation for more advanced OSC experiments with high-gain amplification, currently underway at Fermilab, and the eventual application of OSC to colliders and other accelerator facilities.

Jarvis, Jonathan D. [Fermilab]↗

Mechanisms of Low Dose Radiation-induced T helper Cell Function

Exposure to radiation above levels normally encountered on Earth can occur during wartime, accidents such as those at Three Mile Island and Chernobyl, and detonation of “dirty bombs” by terrorists. Relatively high levels of radiation exposure can also occur in certain occupations (low-level waste sites, nuclear power plants, nuclear medicine facilities, airline industry, and space agencies). Depression or dysfunction of the highly radiosensitive cells of the immune system can lead to serious consequences, including increased risk for infections, cancer, hypersensitivity reactions, poor wound healing, and other pathologies. The focus of this research was on the T helper (Th) subset of lymphocytes that secrete cytokines (proteins), and thus control many actions and interactions of other cell types that make up what is collectively known as the immune system. The Department of Energy (DOE) Low Dose Radiation Program is concerned with mechanisms altered by exposure to high energy photons (x- and gamma-rays), protons and electrons. This study compared, for the first time, the low-dose effects of two of these radiation forms, photons and protons, on the response of Th cells, as well as other cell types with which they communicate. The research provided insights regarding gene expression patterns and capacity to secrete potent immunostimulatory and immunosuppressive cytokines, some of which are implicated in pathophysiological processes. Furthermore, the photon versus proton comparison was important not only to healthy individuals who may be exposed, but also to patients undergoing radiotherapy, since many medical centers in the United States, as well as worldwide, are now building proton accelerators. The overall hypothesis of this study was that whole-body exposure to low-dose photons (gamma-rays) will alter CD4+ Th cell function. We further proposed that exposure to low-dose proton radiation will induce a different pattern of gene and functional changes compared to photons. Over the course of this research, tissues other than spleens were archived and with funding obtained from other sources, including the Department of Radiation Medicine at the Loma Linda University Medical Center, some additional assays were performed. Furthermore, groups of additional mice were included that were pre-exposed to low-dose photons before irradiating with acute photons, protons, and simulated solar particle event (SPE) protons. Hence, the original support together with the additional funding for our research led to generation of much valuable information that was originally not anticipated. Some of the data has already resulted in published articles, manuscripts in review, and a number of presentations at scientific conferences and workshops. Difficulties in reliable and reproducible quantification of secreted cytokines using multi-plex technology delayed completion of this study for a period of time. However, final analyses of the remaining data are currently being performed and should result in additional publications and presentations in the near future. Some of the most notable conclusions, thus far, are briefly summarized below: - Distribution of leukocytes were dependent upon cell type, radiation quality, body compartment analyzed, and time after exposure. Low-dose protons tended to have less effect on numbers of major leukocyte populations and T cell subsets compared to low-dose photons. - The patterns of gene and cytokine expression in CD4+ T cells after protracted low-dose irradiation were significantly modified and highly dependent upon the total dose and time after exposure. - Patterns of gene and cytokine expression differed substantially among groups exposed to low-dose photons versus low-dose protons; differences were also noted among groups exposed to much higher doses of photons, protons, and simulated SPE protons. - Some measurements indicated that exposure to low-dose photon radiation, especially 0.01 Gy, significantly “normalized” at least some adverse effects of simulated SPE protons, thereby suggesting that this low level of radiation may induce protective mechanisms against a relatively large radiation event. - Analysis of signal transduction pathways in CD4+ T cells showed that whole-body priming with 0.01 Gy photons before exposure to simulated SPE protons significantly increased expression of p38MAPK and NF-kappaB, while JNK expression was decreased. Overall, it appears that the p38MAPK signaling pathway may be most important in inducing a radioprotective response.

43 PARTICLE ACCELERATORS↗

“Snowmass’21 Discussions on Future HEP Facilities in the US

The US particle physics community planning exercise (a.k.a. “Snowmass”) is organized every 7 to 9 years to provide a forum for discussions among the entire particle physics community to develop a scientific vision for the future of particle physics in the U.S. and its international partners. The Snowmass'21 Accelerator Frontier activities include discussions on high-energy hadron and lepton colliders, high-intensity beams for neutrino research and for “Physics Beyond Colliders”, accelerator technologies, science, education and outreach as well as the progress of core accelerator technologies, including RF, magnets, targets and sources. Here we summarize the Snowmass'21 discussions on future HEP accelerator facilities.

43 PARTICLE ACCELERATORS↗

Accelerator Science: Luminosity vs. Energy

In the world of high energy physics there are several parameters that are important when one constructs a particle accelerator. Two crucial ones are the energy of the beam and the luminosity, which is another word for the number of particles in the beam. In this video, Fermilab’s Dr. Don Lincoln explains the differences and the pros and cons. He even works in an unexpected sporting event.

43 PARTICLE ACCELERATORS↗

Enrico Fermi Awards Ceremony for Dr. Mildred S. Dresselhaus and Dr. Burton Richter, May 2012 (Presentations, including remarks by Energy Secretary, Dr. Steven Chu)

The Fermi Award is a Presidential award and is one of the oldest and most prestigious science and technology honors bestowed by the U.S. Government. On May 7, 2012 it was conferred upon two exceptional scientists: Dr. Mildred Dresselhaus, 'for her scientific leadership, her major contributions to science and energy policy, her selfless work in science education and the advancement of diversity in the scientific workplace, and her highly original and impactful research,' and Dr. Burton Richter, 'for the breadth of his influence in the multiple disciplines of accelerator physics and particle physics, his profound scientific discoveries, his visionary leadership as SLAC Director, his leadership of science, and his notable contributions in energy and public policy.' Dr. John Holder, Director of the White House Office of Science and Technology Policy, opened the ceremony, and Dr. Bill Brinkman, Director of DOE's Office of Science introduced the main speaker, Dr. Steven Chu, U.S. Energy Secretary.

43 PARTICLE ACCELERATORS↗

Measurement of the Circular Dichroism of Electronic Transitions

This chapter describes the measurement of circular dichroism (CD) for absorption due to transitions between two distinct electronic states. This is distinguished from absorption of lower energy photons, which are associated with changes of only the vibrational modes of the absorber and from the absorption of higher energy photons, which may result in ionizations. From the instrumental viewpoint, the chapter describes the measurement of CD that can be recorded using a photomultiplier or avalanche photodiode to quantify the intensity of a light beam, a photoelastic modulator to periodically alter the beam's polarization, and a monochromator located between the light source and the modulator. Using either criterion, the focus is on the spectral domain spanning about a decade in wavelength (photon energy) from roughly 1.2 {micro}m (1 eV {approx} 160 zJ) in the near infrared to 120 nm (10 eV {approx} 1.6 aJ) in the vacuum ultraviolet (VUV). In the near infrared, there is overlap between the domain of electronic and purely vibrational transitions, the use of photomultipliers or avalanche photodiodes versus solid state detectors and dispersive versus Fourier-transform spectrometers. There is also some overlap in the VUV with synchrotron beamlines that use arrays of magnets called 'insertion devices' to cause the emitted synchrotron radiation to be elliptically polarized. To my knowledge, no single spectrometer spans this entire spectral domain discussed here, and the vast majority of laboratory instruments come nowhere close to either the upper or lower limit. However, similar analytical approaches and types of instrumentation are employed throughout this spectral domain and thus are logically treated together. The focus in this chapter is on the measurement of CD resulting from the inherent chirality of the absorbing system. Several spectroscopic methods that are closely related in terms of science or instrumentation are treated in other chapters. These include magnetic circular dichroism (MCD), linear dichroism (LD), optical rotary dispersion (ORD), fluorescence detected circular dichroism (FDCD), and circularly polarized luminescence (CPL). A basic CD instrument of the type described here can be configured by temporary alterations of the sample compartment, an additional or repositioned detector and modified electronics to perform many of the important experiments in the visible and UV regions. These include unpolarized absorption and total fluorescence in addition to most of the experiments mentioned above. Except for absorption, such extensions of the basic technology will not be discussed here. Other reviews of instrumentation related to CD have appeared, some containing information complementary to that included here.

43 PARTICLE ACCELERATORS↗

Recent Advances in Thermionic Cathodes

The latest advances in thermionic cathodes, including scandate and controlled porosity reservoir cathodes, are reviewed. These new cathodes provide improved performance over conventional cathodes for many applications. Advantages and disadvantages are presented.

43 PARTICLE ACCELERATORS↗

Generating ultrabroadband terahertz radiation based on the under-compression mode of velocity bunching

We propose and analyze a scheme to generate enhanced ultrabroadband terahertz (THz) radiation through coherent transition radiation emitted by ultrashort electron beams based on a 10.5 m beamline at Tsinghua University. The proposed scheme involves the initial compression of the electron beam with a few hundred pC charges using a velocity bunching scheme (i.e., RF compression) in an under-compression mode instead of the usual critical-compression mode in order to maintain a positive energy chirp at the exit of the traveling wave accelerator. After a long drift segment, the particles in the tail catch up with the bunch head. More than 80% of the particles are distributed in a spike with an rms length less than 20 fs. Such beams correspond to an ultrabroadband coherent transition radiation (CTR) spectrum of 0.1 THz to 25 THz, with the single-pulse THz radiation energy of up to 50 {mu}J. The principle of CTR and under-compression mode of velocity bunching are introduced in this paper. And the ASTRA simulation parameters and the stability of the system are also discussed.

43 PARTICLE ACCELERATORS↗

Design of a high-power, high-gain, 2nd harmonic, 22.848 GHz gyroklystron

In this paper we consider the design of a four-cavity, high-gain K-band gyroklystron experiment for high gradient structure testing. The frequency doubling gyroklystron utilizes a beam voltage of 500 kV and a beam current of 200 A from a magnetron injection gun (MIG) originally designed for a lower-frequency device. The microwave circuit features input and gain cavities in the circular TE{sub 011} mode and penultimate and output cavities that operate at the second harmonic in the TE{sub 021} mode. We investigate the MIG performance and study the behavior of the circuit for different values of perpendicular to parallel velocity ratio (α= V{sub ⊥}/ V{sub z}). This microwave tube is expected to be able to produce at least 20 MW of power in 1μs pulses at a repetition rate of at least 120 Hz. A maximum efficiency of 26% and a large signal gain of 58 dB under zero-drive stable conditions were simulated for a velocity ratio equal to 1.35.

43 PARTICLE ACCELERATORS↗