Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Parameter calibration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

SAR calibration: A technology review

Various potential applications of amplitude-calibrated SAR systems are briefly described, along with an estimate of calibration performance requirements. A review of the basic SAR calibration problem is given. For background purposes and to establish consistent definition of terms, various conventional SAR performance parameters are reviewed along with three additional parameters which are directly related to calibrated SAR systems. Techniques for calibrating a SAR are described. Included in the results presented are: calibration philosophy and procedures; review of the calibration signal generator technology development with results describing both the development of instrumentation and internal calibration measurements for two SAR systems; summary of analysis and measurements required to determine optimum retroreflector design and configuration for use as a reference for the absolute calibration of a SAR system; and summary of techniques for in-flight measurements of SAR antenna response.

Larson, R. W.↗

Modeling the X-Ray Process, and X-Ray Flaw Size Parameter for POD Studies

Nondestructive evaluation (NDE) method reliability can be determined by a statistical flaw detection study called probability of detection (POD) study. In many instances the NDE flaw detectability is given as a flaw size such as crack length. The flaw is either a crack or behaving like a crack in terms of affecting the structural integrity of the material. An alternate approach is to use a more complex flaw size parameter. The X-ray flaw size parameter, given here, takes into account many setup and geometric factors. The flaw size parameter relates to X-ray image contrast and is intended to have a monotonic correlation with the POD. Some factors such as set-up parameters including X-ray energy, exposure, detector sensitivity, and material type that are not accounted for in the flaw size parameter may be accounted for in the technique calibration and controlled to meet certain quality requirements. The proposed flaw size parameter and the computer application described here give an alternate approach to conduct the POD studies. Results of the POD study can be applied to reliably detect small flaws through better assessment of effect of interaction between various geometric parameters on the flaw detectability. Moreover, a contrast simulation algorithm for a simple part-source-detector geometry using calibration data is also provided for the POD estimation.

Khoshti, Ajay↗

Modeling the X-ray Process, and X-ray Flaw Size Parameter for POD Studies

Nondestructive evaluation (NDE) method reliability can be determined by a statistical flaw detection study called probability of detection (POD) study. In many instances, the NDE flaw detectability is given as a flaw size such as crack length. The flaw is either a crack or behaving like a crack in terms of affecting the structural integrity of the material. An alternate approach is to use a more complex flaw size parameter. The X-ray flaw size parameter, given here, takes into account many setup and geometric factors. The flaw size parameter relates to X-ray image contrast and is intended to have a monotonic correlation with the POD. Some factors such as set-up parameters, including X-ray energy, exposure, detector sensitivity, and material type that are not accounted for in the flaw size parameter may be accounted for in the technique calibration and controlled to meet certain quality requirements. The proposed flaw size parameter and the computer application described here give an alternate approach to conduct the POD studies. Results of the POD study can be applied to reliably detect small flaws through better assessment of effect of interaction between various geometric parameters on the flaw detectability. Moreover, a contrast simulation algorithm for a simple part-source-detector geometry using calibration data is also provided for the POD estimation.

Koshti, Ajay M.↗

Constitutive Model Development for Aging Polymer Encapsulants (ASC P&EM FY2021 L2 Milestone 7836)

This SAND report fulfills the completion requirements for the ASC Physics and Engineering Modeling Level 2 Milestone 7836 during Fiscal Year 2021. The Sandia Simplified potential energy clock (SPEC) non-linear viscoelastic constitutive model was developed to predict a whole host of polymer glass physical behaviors in order to provide a tool to assess the effects of stress on these materials over their lifecycle. Polymer glasses are used extensively in applications such as electronics packaging, where encapsulants and adhesives can be critical to device performance. In this work, the focus is on assessing the performance of the model in predicting material evolution associated with long-term physical aging, an area that the model has not been fully vetted in. These predictions are key to utilizing models to help demonstrate electronics packaging component reliability over decades long service lives, a task that is very costly and time consuming to execute experimentally. The initiating hypothesis for the work was that a model calibration process can be defined that enables confidence in physical aging predictions under ND relevant environments and timescales without sacrificing other predictive capabilities. To test the hypothesis, an extensive suite of calibration and aging data was assembled from a combination of prior work and collaborating projects (Aging and Lifetimes as well as the DoD Joint Munitions Program) for two mission relevant epoxy encapsulants, 828DGEBA/DEA and 828DGEBA/T403. Multiple model calibration processes were developed and evaluated against the entire set of data for each material. A qualitative assessment of each calibration's ability to predict the wide range of aging responses was key to ranking the calibrations against each other. During this evaluation, predictions that were identified as non-physical, i.e., demonstrated something that was qualitatively different than known material behavior, were heavily weighted against the calibration performance. Thus, unphysical predictions for one aspect of aging response could generate a lower overall rating for a calibration process even if that process generated better quantitative predictions for another aspect of aging response. This insurance that all predictions are qualitatively correct is important to the overall aim of utilizing the model to predict residual stress evolution, which will depend on the interplay amongst the different material aging responses. The DSC-focused calibration procedure generated the best all-around aging predictions for both materials, demonstrating material models that can qualitatively predict the whole host of different physical aging responses that have been measured. This step forward in predictive capability comes from an unanticipated source, utilization of calorimetry measurements to specify model parameters. The DSC-focused calibration technique performed better than compression-focused techniques that more heavily weigh measurements more closely related to the structural responses to be predicted. Indeed, the DSC-focused calibration procedure was only possible due to recent incorporation of the enthalpy and heat capacity features into SPEC that was newly verified during this L2 milestone. Fundamentally similar aspects of the two material model calibrations as well as parametric studies to assess sensitives of the aging predictions are discussed within the report. A perspective on the next steps to the overall goal of residual stress evolution predictions under stockpile conditions closes the report.

36 MATERIALS SCIENCE↗

The Precision and Accuracy of AIRS Level 1B Radiances for Climate Studies

We investigate uncertainties in the Atmospheric Infrared Sounder (AIRS) radiances based on in-flight and preflight calibration algorithms and observations. The global coverage and spectra1 resolution ((lamda)/(Delta)(lamda) ~ 1200) of AIRS enable it to produce a data set that can be used as a climate data record over the lifetime of the instrument. Therefore, we examine the effects of the uncertainties in the calibration and the detector stability on future climate studies. The uncertainties of the parameters that go into the AIRS radiometric calibration are propagated to estimate the accuracy of the radiances and any climate data record created from AIRS measurements. The calculated radiance uncertainties are consistent with observations. Algorithm enhancements may be able to reduce the radiance uncertainties by as much as 7%. We find that the orbital variation of the gain contributes a brightness temperature bias of < 0.01 K.

climate↗

MODIS On-board Blackbody Performance

Currently, there are two MODIS instruments operated on-orbit: one on-board the Terra spacecraft launched in December 1999 and the other on-board the Aqua spacecraft launched in May 2002. MODIS is a scanning radiometer that has 16 thermal emissive bands (TEBs) in the MWIR and LWIR regions. The remaining spectral bands are in the VISINIR and SWIR regions. The TEBs have a total of 160 detectors (10 detectors per band), which are calibrated on-orbit using an on-board blackbody (BB). MODIS TEB calibration is performed via a quadratic algorithm with its linear calibration coefficients updated on a scan-by-scan basis using each detector's response to the BB. The offset and nonlinear terms of the quadratic calibration equation are stored in a look-up table (LUT). The LUT parameters are derived from pre-launch calibration and updated on-orbit from BB observations, as needed. Typically, the BB is set at a fixed temperature. Periodically, a warm-up and cool-down activity is performed, which enables the BB temperature to be varied from instrument ambient up to 315K. The temperature of the BB is measured each scan using 12 thermistors, which were fully characterized pre-launch with reference to the NIST temperature scale. This paper describes MODIS on-board BB operational activities and performance. The TEB detector response (short-term stability and long-term changes) and noise characterization results derived from BB observations and their impact on the TEB calibration uncertainty are also presented.

Xiong, Xiaoxiong↗

Numerical Simulation of AFP Nip Point Temperature Prediction for Complex Geometries

Material placement at the ideal nip point temperature over complex surfaces with uniformity across the width of the compaction rollers results in optimized part properties for Automated Fiber Placement (AFP) processes. However, current AFP systems utilize heat control models and methodologies, based on multiple process parameters such as feed-rate and orientation, that are mostly open-loop. Here, infrared (IR) heater input is calibrated as a function of process parameters during machine qualification. This work presents a numerical simulation to predict arrayed-infrared (AIR) emitter radiation onto a substrate that includes view factor implementation, IR radiative heat flow calculation, energy rate balance, and a transient heat transfer model. The purpose of this numerical model is to predict nip point temperature on complex surfaces, serving as a baseline for a new arrayed-infrared (AIR) thermoset heater to improve AFP process control. It is anticipated that this simulation will accurately control the temperature for high-speed AFP layup of complex geometries. An anticipated result of an AIR heater system is that material calibration and testing will be reduced as temperature is instantaneously monitored and controlled. Therefore, temperature across the roller width will be uniform during placement of complex parts, independent of their geometry.

Xia, Kaishu↗

Sixteen Years of Terra MODIS On-Orbit Operation, Calibration, and Performance

Terra MODIS has successfully operated for more than 16 years since its launch in December 1999. From its observations, many science data products have been generated in support of a broad range of research activities and remote sensing applications. Terra MODIS has operated in a number of configurations and experienced a few anomalies, including spacecraft and instrument related events. MODIS collects data in 36 spectral bands that are calibrated regularly by a set of on-board calibrators for their radiometric, spectral, and spatial performance. Periodic lunar observations and long-term radiometric trending over well-characterized ground targets are also used to support sensor on-orbit calibration. Dedicated efforts made by the MODIS Characterization Support Team (MCST) and continuing support from the MODIS Science Team have contributed to the mission success, enabling well-calibrated data products to be continuously generated and routinely delivered to users worldwide. This paper presents an overview of Terra MODIS mission operations, calibration activities, and instrument performance of the past 16 years. It illustrates and describes the results of key sensor performance parameters derived from on-orbit calibration and characterization, such as signal-to-noise ratio (SNR), noise equivalent temperature difference (NEdT), solar diffuser (SD) degradation, changes in sensor responses, center wavelengths, and band-to-band registration (BBR). Also discussed in this paper are the calibration approaches and strategies developed and implemented in support of MODIS Level 1B data production and re-processing, major challenging issues, and lessons learned. (2016) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.

Xiong, X.↗

Identifying multiple synergistic factors on the susceptibility to stress relaxation cracking in variously heat-treated weldments

The 347H austenitic stainless steel has been widely used for pressure vessels and pipeline (PVP) applications due to its excellent creep and corrosion resistance, which fit ideally to the harsh conditions in petrochemical industries, fossil fuel or nuclear power plants, and modern energy storages. However, a failure mode has been commonly observed with cracks emerging at the heat affected zone (HAZ) of weldments during post-weld heat treatment (PWHT) or under intermediate to high temperature service conditions. This phenomenon is termed as Stress Relaxation Cracking (SRC) since the purpose of PWHT is to relieve the welding-induced residual stress fields, or as Stress Age Cracking (SAC) if failure happens during service. A leading literature explanation of this failure suggests that the residual stress relaxation and the precipitation dissolution and/or re-precipitation occur in the same temperature range, which can lead to locally high strains and thus to crack at the grain boundaries. Since in situ spatial measurements of residual stress fields, microstructural evolution, and failure processes are nearly infeasible, this work recourses to a micromechanical finite element framework that models the high temperature failure as the nucleation and growth of grain boundary cavities, whereas various parameters such as thermomechanical loading history and its evolution, the competition of grain-interior dislocation creep and grain-boundary diffusion in failure lifetime, and microstructural heterogeneities (such as the precipitate free zone near grain boundaries) can be quantitatively incorporated. It can be concluded from these microstructure-explicit simulations that an accurate knowledge of residual stress evolution and a carefully calibrated set of material constitutive parameters are the essential prerequisites for lifetime predictions. The understanding of individual governing factors also leads to a mechanistic interpretation of the observed SRC susceptibility C-curves. In conclusion, these results suggest that the criticality of residual stress evolution, but not the precipitation-induced local strains, be the leading factor for SRC.

347H stainless steel weldments↗

Improving the SMAP Level-4 Soil Moisture Product

The NASA Soil Moisture Active Passive (SMAP) mission generates, among other data sets, the Level 4 Soil Moisture (L4 SM) product. The L4 SM algorithm is based on the assimilation of SMAP radiometer brightness temperature observations into the NASA Catchment land surface model using a spatially distributed ensemble Kalman filter. The L4 SM data are published with a mean latency of approx. 2.5 days from the time of observation and provide global, three-hourly, 9 km resolution estimates of surface and root-zone soil moisture and related land surface states and fluxes. In 2018, the product was upgraded from Version 3 to Version 4. Underlying the new version is a revised modeling system that includes improved input parameter datasets for land cover, topography, and vegetation height that are based on recent, high quality space-borne remote sensing observations. Land cover inputs were updated to the GlobCover2009 product, which is based on satellite observations from the Medium Resolution Imaging Spectrometer. Topographic statistics now rely on observations from the Shuttle Radar Topography Mission. Finally, vegetation height inputs are derived from space-borne Lidar measurements. Additionally, SMAP Level-2 soil moisture retrievals and in situ soil moisture measurements were used to calibrate a particular Catchment model parameter that governs the recharge of soil moisture from the models root-zone excess reservoir into the surface excess reservoir. Specifically, the replenishment of soil moisture near the surface from below under non-equilibrium conditions was substantially reduced, which brings the models surface soil moisture more in line with the SMAP Level 2 and in situ soil moisture. Finally, the calibration of the assimilated SMAP brightness temperatures changed substantially from Version 3 to Version 4. Considerable effort went into the version upgrade, creating an expectation that the new version is improved over the old version. Indeed, some aspects of the new version are clearly better. However, other aspects are not, and on balance, the overall improvement is modest at best. In this presentation we summarize the skill of the new and old versions vs. independent in situ measurements and in terms of data assimilation diagnostics, including, for example, the statistics of the (soil moisture) analysis increments and the observation minus forecast (brightness temperatures) residuals. We share our experience with trying to improve to the L4 SM product and the lessons learned from the effort.

Reichle, Rolf↗

A Comprehensive Calibration Framework for the Northwest River Forecast Center

We present a comprehensive framework developed by the Northwest River Forecast Center for calibrating hydrologically diverse basins. The framework includes models for snow, soil moisture, routing, channel loss, and consumptive use. Data inputs include a wide range of open-access datasets for meteorology, land use, topography, and land cover. The framework uses conceptual hydrologic models to handle basins with various hydrologic regimes including rain-driven and snowmelt-dominated basins. We also develop a flexible automatic calibration system that can handle numerous unobservable model parameters in a computationally efficient manner. A single-basin automatic calibration run can typically be completed on a modern laptop in under 10 min. We found that model performance metrics for this new approach match the quality of the NWRFC's previous labor-intensive manual calibrations. The model performance also rivals that of a state-of-the-art deep learning model at a fraction of the computational cost. This framework presents a new standard for the quality of calibrations possible with lumped conceptual hydrologic models, combining careful data curation, an objective calibration framework, and expert local knowledge. In addition, we have made software packages available for the entire suite of National Weather Service River Forecast System models, including SAC-SMA, SNOW-17, and Lag-K. These modern interfaces are intended to increase accessibility and facilitate future research.

Forecasting↗

Hyper Suprime-Cam Year 3 results: Cosmology from galaxy clustering and weak lensing with HSC and SDSS using the emulator based halo model

We present cosmology results from a blinded joint analysis of cosmic shear, galaxy-galaxy weak lensing, and projected galaxy clustering, measured from the Hyper Suprime-Cam three-year (HSC-Y3) shape catalog and the Sloan Digital Sky Survey (SDSS) DR11 spectroscopic galaxy catalog—a cosmology analysis. We define luminosity-cut, and therefore nearly volume-limited, samples of SDSS galaxies to serve as the tracers of w p and as the lens samples for Δ⁢Σ in three spectroscopic redshift bins spanning the range 0.15± and Δ⁢Σ measurements, we use a single sample of about seven million source galaxies over 416 deg 2 , selected from HSC-Y3 based on having photometric redshifts (photo-z) greater than 0.75. The deep, high-quality HSC-Y3 data enable significant detections of the Δ⁢Σ signals, with integrated signal-to-noise ratio S/N~24 in the range 3≤R/[ℎ –1 Mpc]≤30 over the three lens samples. ξ ± has S/N ~19 in the range 8' ≤$\theta$ ≤5⁢0' and 30' ≤$\theta$ ≤15⁢0' for ξ + and ξ – , respectively. For cosmological parameter inference, we use the dark emulator package, combined with a halo occupation distribution prescription for the relation between galaxies and halos, to model w p and Δ⁢Σ down to quasinonlinear scales, and we estimate cosmological parameters after marginalizing over nuisance parameters. In our baseline analysis we employ an uninformative flat prior of the residual photo-z error, given by Π⁡(Δz ph )=$U$⁡(–1,1), to model a residual bias in the mean redshift of HSC source galaxies. Comparing the relative lensing amplitudes for Δ⁢Σ in the three redshift bins and for ξ ± with the single HSC source galaxy sample allows us to calibrate the photo-z parameter Δ⁢z ph to the precision of σ⁡(Δ⁢z ph )≃0.09. With these methods, we obtain a robust constraint on the cosmological parameters for the flat Λ⁢CDM model: S 8 =σ 8 ⁢(Ω m /0.3) 0.5 =$0.763^{+0.040}_{–0.036}$, or the best-constrained parameter given by $S^{'}_{8}$ = σ 8 ⁢(Ω m /0.3) 0.22 =0.721±0.028, determined with about 4% fractional precision. Based on multidimensional tension metrics, HSC-Y3 data exhibits about 2.5σ tension with the cosmological constraint inferred by Planck for the Λ⁢CDM model, and hints at a nonzero residual photo-z bias implying that the true mean redshift of the HSC galaxies at z ≳0.75 is higher than that implied by the original photo-z estimates.

79 ASTRONOMY AND ASTROPHYSICS↗

Source scaling comparison and validation in Central Italy: data intensive direct S waves versus the sparse data coda envelope methodology

SUMMARY Robustness of source parameter estimates is a fundamental issue in understanding the relationships between small and large events; however, it is difficult to assess how much of the variability of the source parameters can be attributed to the physical source characteristics or to the uncertainties of the methods and data used to estimate the values. In this study, we apply the coda method by Mayeda et al. using the coda calibration tool (CCT), a freely available Java-based code (https://github.com/LLNL/coda-calibration-tool) to obtain a regional calibration for Central Italy for estimating stable source parameters. We demonstrate the power of the coda technique in this region and show that it provides the same robustness in source parameter estimation as a data-driven methodology [generalized inversion technique (GIT)], but with much fewer calibration events and stations. The Central Italy region is ideal for both GIT and coda approaches as it is characterized by high-quality data, including recent well-recorded seismic sequences such as L'Aquila (2009) and Amatrice–Norcia–Visso (2016–2017). This allows us to apply data-driven methods such as GIT and coda-based methods that require few, but high-quality data. The data set for GIT analysis includes ∼5000 earthquakes and more than 600 stations, while for coda analysis we used a small subset of 39 events spanning 3.5 < Mw < 6.33 and 14 well-distributed broad-band stations. For the common calibration events, as well as an additional 247 events (∼1.7 < Mw < ∼5.0) not used in either calibration, we find excellent agreement between GIT-derived and CCT-derived source spectra. This confirms the ability of the coda approach to obtain stable source parameters even with few calibration events and stations. Even reducing the coda calibration data set by 75 per cent, we found no appreciable degradation in performance. This validation of the coda calibration approach over a broad range of event size demonstrates that this procedure, once extended to other regions, represents a powerful tool for future routine applications to homogeneously evaluate robust source parameters on a national scale. Furthermore, the coda calibration procedure can homogenize the Mw estimates for small and large events without the necessity of introducing any conversion scale between narrow-band measures such as local magnitude (ML) and Mw, which has been shown to introduce significant bias.

Morasca, Paola (ORCID:0000000265254867)↗

The AGORA High-resolution Galaxy Simulations Comparison Project. III. Cosmological Zoom-in Simulation of a Milky Way–mass Halo

In this work, we present a suite of high-resolution cosmological zoom-in simulations to z = 4 of a 10 12 M⊙ halo at z = 0, obtained using seven contemporary astrophysical simulation codes (Art-I, Enzo, Ramses, Changa, Gadget-3, Gear, and Gizmo) widely used in the numerical galaxy formation community. The physics prescriptions for gas cooling and heating and star formation are the same as the ones used in our previous Assembling Galaxies of Resolved Anatomy (AGORA) disk comparison but now account for the effects of cosmological processes such as the expansion of the universe, intergalactic gas inflow, and the cosmic ultraviolet background radiation emitted by massive stars and quasars. In this work, we introduce the most careful comparison yet of galaxy formation simulations run by different code groups, together with a series of four calibration steps each of which is designed to reduce the number of tunable simulation parameters adopted in the final run. In the first two steps, we methodically calibrate the gas physics, such as cooling and heating, in simulations without star formation. In the third step, we seek agreement on the total stellar mass produced with the common star formation prescription used in the AGORA disk comparison, in stellar-feedback-free simulations. In the last calibration step, we activate stellar feedback, where each code group is asked to set the feedback prescription to as close to the most widely used one in its code community as possible, while aiming for convergence in the stellar mass at z = 4 to the values predicted by semiempirical models. After all the participating code groups successfully complete the calibration steps, we achieve a suite of cosmological simulations with similar mass assembly histories down to z = 4. With numerical accuracy that resolves the internal structure of a target halo (≲100 physical pc at z = 4), we find that the codes overall agree well with one another, e.g., in gas and stellar properties, but also show differences, e.g., in circumgalactic medium (CGM) properties. We argue that, if adequately tested in accordance with our proposed calibration steps and common parameters, high-resolution cosmological zoom-in simulations can have robust and reproducible results. New code groups are invited to join and enrich this comparison by generating equivalent models or to test the code's compatibility on their own, by adopting the common initial conditions, the common easy-to-implement physics package, and the proposed calibration steps. Further analyses of the zoom-in simulations presented here will be presented in forthcoming reports from the AGORA Collaboration, including studies of the CGM, simulations by additional codes, and results at lower redshift.

79 ASTRONOMY AND ASTROPHYSICS↗

Simulating energy performance of buildings: a study using eQUEST and Energy Star ® portfolio manager

Commercial buildings consume significant energy in the United States and exhibit high potential for energy use reduction through retrofits. Benchmarking and energy simulation are well established tools in the industry to identify potential improvements and measure performance. Analysis to identify most sensitive retrofit parameters to energy performance can optimize investment and available energy savings. Presented study demonstrates methodology using a static model to determine sensitivity of building design and retrofit parameters with respect to energy performance. Calibrated simulation energy models (eQUEST) of two distribution centers (A, B) are presented. A fractional factorial analysis is conducted on retrofit parameters of efficiency measures targeting the highest energy consumers, and the results are benchmarked using Energy Star® Portfolio Manager. A custom Microsoft Excel® based simulation model is created to simulate occupancy levels, lighting, plug loads, and other equipment used in various spaces throughout the day. For Building A, efficient lighting was the most influential parameter for energy savings, carbon savings and benchmarking score; whereas, for Building B, HVAC efficiency was most influential for energy and demand controlled ventilation and economizers was most influential for benchmarking score. While retrofit projects can save energy and carbon emissions, variation in source-site ratios and state grid emissions, benchmarking scores may not always reflect equivalent improvement. State grid emissions factors, natural gas composition are difficult to model and hence not considered in this study. In conclusion, the synergistic analysis presented, emphasizes the importance of benchmarking and efficiency retrofits in promoting sustainable building practices to reduce energy consumption.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Utilizing Commercial Hardware and Open Source Computer Vision Software to Perform Motion Capture for Reduced Gravity Flight

Long duration space travel to Mars or to an asteroid will expose astronauts to extended periods of reduced gravity. Since gravity is not present to aid loading, astronauts will use resistive and aerobic exercise regimes for the duration of the space flight to minimize the loss of bone density, muscle mass and aerobic capacity that occurs during exposure to a reduced gravity environment. Unlike the International Space Station (ISS), the area available for an exercise device in the next generation of spacecraft is limited. Therefore, compact resistance exercise device prototypes are being developed. The NASA Digital Astronaut Project (DAP) is supporting the Advanced Exercise Concepts (AEC) Project, Exercise Physiology and Countermeasures (ExPC) project and the National Space Biomedical Research Institute (NSBRI) funded researchers by developing computational models of exercising with these new advanced exercise device concepts. To perform validation of these models and to support the Advanced Exercise Concepts Project, several candidate devices have been flown onboard NASAs Reduced Gravity Aircraft. In terrestrial laboratories, researchers typically have available to them motion capture systems for the measurement of subject kinematics. Onboard the parabolic flight aircraft it is not practical to utilize the traditional motion capture systems due to the large working volume they require and their relatively high replacement cost if damaged. To support measuring kinematics on board parabolic aircraft, a motion capture system is being developed utilizing open source computer vision code with commercial off the shelf (COTS) video camera hardware. While the systems accuracy is lower than lab setups, it provides a means to produce quantitative comparison motion capture kinematic data. Additionally, data such as required exercise volume for small spaces such as the Orion capsule can be determined. METHODS: OpenCV is an open source computer vision library that provides the ability to perform multi-camera 3 dimensional reconstruction. Utilizing OpenCV, via the Python programming language, a set of tools has been developed to perform motion capture in confined spaces using commercial cameras. Four Sony Video Cameras were intrinsically calibrated prior to flight. Intrinsic calibration provides a set of camera specific parameters to remove geometric distortion of the lens and sensor (specific to each individual camera). A set of high contrast markers were placed on the exercising subject (safety also necessitated that they be soft in case they become detached during parabolic flight); small yarn balls were used. Extrinsic calibration, the determination of camera location and orientation parameters, is performed using fixed landmark markers shared by the camera scenes. Additionally a wand calibration, the sweeping of the camera scenes simultaneously, was also performed. Techniques have been developed to perform intrinsic calibration, extrinsic calibration, isolation of the markers in the scene, calculation of marker 2D centroids, and 3D reconstruction from multiple cameras. These methods have been tested in the laboratory side-by-side comparison to a traditional motion capture system and also on a parabolic flight.

Biodynamics↗

Model certainty in cellular network-driven processes with missing data

Mathematical models are often used to explore network-driven cellular processes from a systems perspective. However, a dearth of quantitative data suitable for model calibration leads to models with parameter unidentifiability and questionable predictive power. Here we introduce a combined Bayesian and Machine Learning Measurement Model approach to explore how quantitative and non-quantitative data constrain models of apoptosis execution within a missing data context. We find model prediction accuracy and certainty strongly depend on rigorous data-driven formulations of the measurement, and the size and make-up of the datasets. For instance, two orders of magnitude more ordinal (e.g., immunoblot) data are necessary to achieve accuracy comparable to quantitative (e.g., fluorescence) data for calibration of an apoptosis execution model. Notably, ordinal and nominal (e.g., cell fate observations) non-quantitative data synergize to reduce model uncertainty and improve accuracy. Finally, we demonstrate the potential of a data-driven Measurement Model approach to identify model features that could lead to informative experimental measurements and improve model predictive power.

59 BASIC BIOLOGICAL SCIENCES↗

The correspondence of surface climate parameters with satellite and terrain data

One of the goals of the research was to develop a ground sampling stragegy for calibrating remotely sensed measurements of surface climate parameters. The initial sampling strategy involved the stratification of the terrain based on important ancillary surface variables such as slope, exposure, insolation, geology, drainage, fire history, etc. For a spatially heterogeneous population, sampling error is reduced and efficiency increased by stratification of the landscape into more homogeneous sub-areas and by employing periodic random spacing of samples. These concepts were applied in the initial stratification of the study site for the purpose of locating and allocating instrumentation.

Dozier, Jeff↗