Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PV installation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

PV DMFA [SWR-21-105]

The Photovoltaic Dynamic Material Flow Assessment (PV DMFA) model (also referred to here as “The model”) is a computational framework written in Python based on utility-scale PV electricity generation to quantify time-series stocks and flows of PV materials primarily in crystalline silicon PV technologies. The model evaluates cradle-to-cradle life cycle of utility-scale solar PV systems in the United States in the period 2000-2100. PV DMFA serves as a sustainability analysis tool to assess the impacts of different material circularity practices (i.e., reduce, reuse/refurbish, remanufacture, and recycle), PV module design shifts and sensitivity of material processing and technology related parameters to material installations, waste creation and raw material depletion in PV material supply chains. This tool enables advanced planning for future material needs and informs sustainable pathways for PV material management in the circular economy. This tool could be helpful to a wide range of stakeholders; Particularly, researchers and manufacturers looking for technoeconomic and/or environmental life cycle analysis (LCA) feedback for renewable energy (RE) systems.

Khalifa, SherifA.↗

City-Wide Distributed Roof-Top Photovoltaic System Adoption Forecast, Grid Impact Simulation, & Neighborhood Microgrid Contribution Assessment

The adoption of distributed photovoltaic (PV) systems grew significantly in recent years. Market projections anticipate future growth for both residential and commercial installations. To understand grid impacts associated with distributed PV, useful hosting capacity studies require accurate representations of the spatial distribution of PV adoptions. Prediction of PV locations and numbers depends on median income data, building use zoning maps, and permit records to understand existing trends and predict future adoption rates and locations throughout an entire city. Using the PV adoption data, advanced and realistic simulations were performed to capture the distributed PV impacts on the grid. Also, using graph theory community detection hundreds of neighborhood microgrids can be discovered for the entire city by identifying densely connected loads that are sparsely connected to other communities. Then, based on the PV adoption predictions, this work identified the contribution of PV within each of the newly discovered graph theory defined microgrid communities.

24 POWER TRANSMISSION AND DISTRIBUTION↗

The Value of Transparency in Distributed Solar PV Markets

Market transparency refers to the degree of customer awareness of product options and fair market prices for a given good. In The Value of Transparency in Distributed Solar PV Markets, we use residential solar photovoltaic (PV) quote data to study the value of transparency in distributed solar PV markets. We find that improved market transparency results in lower installation offer prices. Further, the results of this study suggest that PV customers benefit from gaining access to more PV quotes.

14 SOLAR ENERGY↗

PV Reliability Lessons from 100,000 Systems

Despite the importance of reliability to the cost competitiveness of PV, large data sets enabling high-level investigation of the technology’s performance in the field are relatively scarce. Dirk C. Jordan, Chris Deline, Bill Marion and Teresa Barnes of the National Renewable Energy Laboratory, and Mark Bolinger of the Lawrence Berkeley National Laboratory study a unique data set of 100,000 PV systems in the US, drawing out tips for better reliability that have relevance to other parts of the world.

41 EE - Solar Energy Technologies Office (EE-4S)↗

High-Penetration PV Integration Handbook for Distribution Engineers

This handbook has been developed as part of a five-year research project which began in 2010. The National Renewable Energy Laboratory (NREL), Southern California Edison (SCE), Quanta Technology, Satcon Technology Corporation, Electrical Distribution Design (EDD), and Clean Power Research (CPR) teamed together to analyze the impacts of high-penetration levels of photovoltaic (PV) systems interconnected onto the SCE distribution system. This project was designed specifically to leverage the experience that SCE and the project team would gain during the significant installation of 500 MW of commercial scale PV systems (1-5 MW typically) starting in 2010 and completing in 2015 within SCE’s service territory through a program approved by the California Public Utility Commission (CPUC).

14 SOLAR ENERGY↗

DC-Connected Solar Plus Storage Modeling and Analysis for Behind-the-Meter Systems in the System Advisor Model

A detailed model for PV plus DC-connected batteries was developed. This model was compared to an existing ACconnected battery model in the System Advisor Model (SAM) tool using a hypothetical Honolulu residence with a PV plus storage system. The stand-alone PV system was shown to provide the most value; however due to the increased difficulty of PV systems being approved for grid interconnection in Hawaii, it is valuable to install an AC or DC connected battery to enable full PV self-consumption under a less restrictive interconnection option. In that case both battery systems enabled full PV selfconsumption at the residence, requiring no power to be exported to the grid. The DC-connected battery system captured energy from the PV array which would have also been clipped due to inverter limitations. For a PV system with DC/AC ratio of 1.23, the battery configurations produced net-present values within 1% of each other, but when the DC/AC ratio increased to 1.85, the DC-connected system increased the net-present value by 13%.

14 SOLAR ENERGY↗

DC-connected Solar Plus Storage Modeling and Analysis for Behind-The-Meter Systems in the System Advisor Model: Preprint

A detailed model for PV plus DC-connected batteries was developed. This model was compared to an existing AC connected battery model in the System Advisor Model (SAM) tool using a hypothetical Honolulu residence with a PV plus storage system. The stand-alone PV system was shown to provide the most value; however due to the increased difficulty of PV systems being approved for grid interconnection in Hawaii, it is valuable to install an AC or DC connected battery to enable full PV self-consumption under a less restrictive interconnection option. In that case both battery systems enabled full PV self consumption at the residence, requiring no power to be exported to the grid. The DC-connected battery system captured energy from the PV array which would have also been clipped due to inverter limitations. For a PV system with DC/AC ratio of 1.23, the battery configurations produced net-present values within 1% of each other, but when the DC/AC ratio increased to 1.85, the DC-connected system increased the net-present value by 13%.

14 SOLAR ENERGY↗

DC-Connected Solar Plus Storage Modeling for Behind-the-Meter Systems in SAM

A detailed model for PV plus DC-connected batteries was developed. This model was compared to an existing AC connected battery model in the System Advisor Model (SAM) tool using a hypothetical Honolulu residence with a PV plus storage system. The stand-alone PV system was shown to provide the most value; however due to the increased difficulty of PV systems being approved for grid interconnection in Hawaii, it is valuable to install an AC or DC connected battery to enable full PV self-consumption under a less restrictive interconnection option. In that case both battery systems enabled full PV self consumption at the residence, requiring no power to be exported to the grid. The DC-connected battery system captured energy from the PV array which would have also been clipped due to inverter limitations. For a PV system with DC/AC ratio of 1.23, the battery configurations produced net-present values within 1% of each other, but when the DC/AC ratio increased to 1.85, the DC-connected system increased the net-present value by 13%.

14 SOLAR ENERGY↗

Uncertainty Quantification of Bifacial Performance Modeling

Analysis on uncertainty in the annual energy of PV systems that can be attributed to parameters of particular importance to bifacial PV modules is presented. Monte Carlo simulations are used to evaluate the effect of uncertain module bifaciality factors, module transmission fractions, albedo values, and ground clearance. The analyses cover a wide spectrum of potential PV array archetypes through variation of installation parameters. The results of the Monte Carlo analysis reveal that the uncertainty is largely dependent on albedo uncertainty, but more simulations are needed to identify trends across system archetypes. The simulations are aimed at attributing an annual energy uncertainty factor for bifacial considerations that can be applied in post-processing of project probability of exceedance analysis.

bifacial↗

Preliminary Environmental and Financial Viability Analysis of Circular Economy Scenarios for Satisfying PV System Service Lifetime

PV deployment has grown rapidly in recent decades, and this growth is expected to continue. At the same time, the rapid increase in PV panel efficiencies offers the opportunity to repower/revamp existing installations - replacing operational, lower-efficiency panels before the end of their 30-year service lifetime with newer, higher-efficiency panels. As a result, an increasing volume of PV panels could be decommissioned well before reaching the end of their 30-year service lifetime. Two broad strategies can be applied to manage the expected increase in decommissioned PV panels: (i) recycle prematurely decommissioned panels, and (ii) prevent recycling of these panels by satisfying the typical service lifetime of 30 years through circular economy strategies such as repair and reuse. Each strategy presents an environmental and economic trade-off. Retaining and satisfying the lifetime of the older, lower-efficiency panels avoids environmental burdens from recycling or landfilling but incurs burdens from additional repair and forgoing the opportunity to install newer panels with greater electricity-generation capabilities. This study assesses whether satisfying the expected service lifetime of a PV system through circular economy scenarios generates a greater environmental and financial benefit than recycling used panels and installing newer panels with higher efficiencies. The circular economy scenarios include repair and reuse of the PV system. Specifically, the study determines whether it is better for the environment to keep a PV panel in use for its 30-year service life after accounting for potential repair and additional transportation, or to replace older panels with more efficient new ones. In addition, we explore whether satisfying the service lifetime of PV panels proves competitive with the recycling route from a financial perspective.

14 SOLAR ENERGY↗

Tracking the Sun: Pricing and Design Trends for Distributed Photovoltaic Systems in the United States - 2019 Edition

Lawrence Berkeley National Laboratory (LBNL)’s annual Tracking the Sun report summarizes installed prices and other trends among grid-connected, distributed solar photovoltaic (PV) systems in the United States. This edition focuses on systems installed through year-end 2018, with preliminary trends for the first half of 2019. As in years past, the primary emphasis is on describing changes in installed prices over time and variation across projects. This year’s report also includes an expanded discussion of other key technology and market trends, along with several other new features, as noted in the text box below.

14 SOLAR ENERGY↗

Installed Cost Benchmarks and Deployment Barriers for Residential Solar Photovoltaics with Energy Storage: Q1 2016

In this report, we fill a gap in the existing knowledge about PV-plus-storage system costs and value by providing detailed component- and system-level installed cost benchmarks for residential systems. We also examine other barriers to increased deployment of PV-plus-storage systems in the residential sector. The results are meant to help technology manufacturers, installers, and other stakeholders identify cost-reduction opportunities and inform decision makers about regulatory, policy, and market characteristics that impede solar plus storage deployment. In addition, our periodic cost benchmarks will document progress in cost reductions over time. To analyze costs for PV-plus-storage systems deployed in the first quarter of 2016, we adapt the National Renewable Energy Laboratory's component- and system-level cost-modeling methods for standalone PV. In general, we attempt to model best-in-class installation techniques and business operations from an installed-cost perspective. In addition to our original analysis, model development, and review of published literature, we derive inputs for our model and validate our draft results via interviews with industry and subject-matter experts. One challenge to analyzing the costs of PV-plus-storage systems is choosing an appropriate cost metric. Unlike standalone PV, energy storage lacks universally accepted cost metrics, such as dollars per watt of installed capacity and lifetime levelized cost of energy. We explain the difficulty of arriving at a standard approach for reporting storage costs and then provide the rationale for using the total installed costs of a standard PV-plus-storage system as our primary metric, rather than using a system-size-normalized metric.

14 SOLAR ENERGY↗

Broad Overview of Energy Efficiency and Renewable Energy Opportunities for Department of Defense Installations

The Strategic Environmental Research and Developmental Program (SERDP)/Environmental Security Technology Certification Program (ESTCP) is the Department of Defense?s (DOD) environmental science and technology program focusing on issues related to environment and energy for the military services. The SERDP/ESTCP Office requested that the National Renewable Energy Laboratory (NREL) providetechnical assistance with strategic planning by evaluating the potential for several types of renewable energy technologies at DOD installations. NREL was tasked to provide technical expertise and strategic advice for the feasibility of geothermal resources, waste-to-energy technology, photovoltaics (PV), wind, microgrids, and building system technologies on military installations. Thistechnical report is the deliverable for these tasks.

14 SOLAR ENERGY↗

Transfer Printed Microcells with Micro-Optic Concentrators for Low Cost, High Performance Photovoltaic Modules (Final Scientific and Technical Report)

This program of work established and validated a new form factor and fully scalable manufacturing processes for low cost, high performance photovoltaic modules. The programmatic highlights of the work include cost-effective assembly of modules fabricated from single crystalline semiconductor inks by high-throughput transfer printing of the micro-cells, advanced methods of systems level integration of sparse arrays, and design and fabrication of micro optical concentrator arrays that provide significant collection efficiencies of light and high performance of the system when integrated with the PV array module. The designs further provide efficient but fully passive heat management that simplifies fabrication while further enhancing operating capabilities of the modules. This collaborative program of research carried out under this award has exceeded all key guidelines laid out in the original proposal. It first has provided a new means to utilize high performance semiconductor materials in an exceptionally low cost and robust form factor. The technology so engendered by these key materials discoveries, new means of manufacturing, and advanced systems level designs are establishing new benchmarks for reductions in the installed cost/kWh relative to any commercial photovoltaic (PV) energy technology currently in use. The work in this program, having surpassed its key scientific milestones, has gone further and with our partners has now fully validated designs with scalable manufacturing methods for photovoltaic modules that use large-scale arrays of high efficiency solar microcells created from bulk wafers, integrating them in diverse spatial layouts on foreign substrates by transfer printing. Full research modules installed and operating at a utility site since 2010 have established the designs to be a viable PV technology.

36 MATERIALS SCIENCE↗

Microgrid Hardening Design Toolkit: Puerto Rico Use Case

This document provides a comprehensive example of the microgrid hardening framework and the Sandia developed Microgrid Hardening Design Toolkit v0.27 using a census tract in a coastal area of southern Puerto Rico as a case study. The census tract (72123953100) is located in the municipality of Salinas. Currently, the La Margarita neighborhood within this census tract is part of the Department of Energy’s Cohort 5 of the Energy Technology Innovation and Partnership Program (ETIPP). The neighborhood’s local energy cooperative, Abeyno Coop, has been operating several residential solar photovoltaic (PV) and battery energy storage system (BESS) installations (with around 30 rooftop solar systems as of 2026). As part of the ETIPP project, Abeyno Coop is planning to integrate a larger microgrid into the existing distribution feeder in the area, including solar PV and BESS to supply energy for homes and critical loads such as the medical facilities and the community center that provides emergency shelter and backup power during outages.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Analyzing the Energy Performance, Wind Loading, and Costs of Photovoltaic Slat Modules on Commercial Rooftops

NREL studied a new type of photovoltaic (PV) module configuration wherein multiple narrow, tilted slats are mounted in a single frame. Each slat of the PV slat module contains a single row of cells and is made using ordinary crystalline silicon PV module materials and processes, including a glass front sheet and weatherproof polymer encapsulation. Compared to a conventional ballasted system, a system using slat modules offer higher energy production and lower weight at lower LCOE. The key benefits of slat modules are reduced wind loading, improved capacity factor and reduced installation cost. First, the individual slats allow air to flow through, which reduce wind loading. Using PV performance modeling software, we compared the performance of an optimized installation of slats modules to a typical installation of conventional modules in a ballasted rack mounting system. Based on the results of the performance modeling two different row tilt and spacing were tested in a wind tunnel. Scaled models of the PV Slat modules were wind tunnel tested to quantify the wind loading of a slat module system on a commercial rooftop, comparing the results to conventional ballasted rack mounted PV modules. Some commercial roofs do not have sufficient reserve dead load capacity to accommodate a ballasted system. A reduced ballast system design could make PV system installation on these roofs feasible for the first time without accepting the disadvantages of penetrating mounts. Finally, technoeconomic analysis was conducted to enable an economic comparison between a conventional commercial rooftop system and a reduced-ballast slat module installation.

14 SOLAR ENERGY↗

Utility-Scale Solar, 2024 Edition: Empirical Trends in Deployment, Technology, Cost, Performance, PPA Pricing, and Value in the United States [Slides]

Berkeley Lab’s “Utility-Scale Solar, 2024 Edition” presents analysis of empirical plant-level data from the U.S. fleet of ground-mounted photovoltaic (PV), PV+battery, and concentrating solar-thermal power (CSP) plants with capacities exceeding 5 MWAC (PV plants of 5 MWAC or less, including residential rooftop systems, are covered separately in Berkeley Lab’s companion annual report, Tracking the Sun). Key findings from this year’s report include: -18.5 GWAC of new utility-scale PV capacity came online in 2023, bringing cumulative installed capacity to more than 80.2 GWAC across 47 states. Installed costs continued to fall in 2023. Relative to 2022, capacity-weighted averages decreased by 8% to -$\$1.43$/WAC (or $\$1.08$/WDC). Costs, based on a 7.1 GWAC sample of 76 plants completed in 2023, have fallen by 75% (averaging 10% annually) since 2010. Plant-level capacity factors vary widely, from 6% to 36% (on an AC basis), with a sample median of 24%. -Levelized cost of energy (LCOE) of new 2023 projects increased slightly to $\$46$/MWh prior to the application of tax credits but continued to fall to $\$31$/MWh when accounting for federal incentives. PPA prices have largely followed the decline in solar’s LCOE over time, but newly signed longer-term PPA prices have increased since 2021, to an average of $\$35$/MWh (levelized, in 2023 dollars). -Solar’s average energy and capacity value (i.e., ability to offset costs of other power generation sources) across the U.S. was $\$45$/MWh in 2023. Solar’s average market value was lowest in CAISO ($\$27$/MWh), the market with the greatest solar generation share, and highest in ERCOT ($\$67$/MWh). -Newer solar projects had greater market value in 2023 than their generation costs, yielding $\$1.1$ billion in benefits. Projects built in 2022 delivered on average $\$15$/MWh more market value than their costs in 2023. -Solar’s combined value from wholesale electricity markets, public health and climate damage reduction were greater than generation costs and incentives, yielding $\$13.7$ billion in net benefits in 2023. We estimate U.S. health benefits of $\$24$/MWh and reduced global climate damages of $\$101$/MWh. -Adding battery storage is one way to increase the value of solar. Deployment of 52 new PV+battery hybrid plants set a record with 5.3 GW installed in 2023. Our public data file tracks metadata and PPA prices from more than 100 PV+battery hybrid projects that are already online or that have secured offtake arrangements. -Looking ahead, a massive pipeline of at least 1,085 GW of solar capacity dominates the nation’s interconnection queues at the end of 2023. Nearly 571 GW, or 53%, of that total was paired with a battery – in CAISO it was a staggering 98%. Historically only 10% of the requested solar capacity is built. -For more information, and to explore related interactive data visualizations, go to utilityscalesolar.lbl.gov.

14 SOLAR ENERGY↗