Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PROBE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

A Common Probe Design for Multiple Planetary Destinations

Atmospheric probes have been successfully flown to planets and moons in the solar system to conduct in-situ measurements. They include the Pioneer Venus multi-probes, the Galileo Jupiter probe, and Huygens probe. Probe mission concepts to five destinations, including Venus, Jupiter, Saturn, Uranus, and Neptune, have all utilized similar-shaped aeroshells and concept of operations, namely a 45 deg sphere cone shape with high density heatshield material and parachute system for extracting the descent vehicle from the aeroshell. Each concept designed its probe to meet specific mission requirements and to optimize mass, volume, and cost. At the 2017 IPPW, NASA Headquarters postulated that a common aero-shell design could be used successfully for multiple destinations and missions. This "common probe" design could even be assembled with multiple copies, properly stored, and made available for future NASA missions, potentially realizing savings in cost and schedule and reducing the risk of losing technologies and skills difficult to sustain over decades. Thus the NASA Planetary Science Division funded a study to investigate whether a common probe design could meet most, if not all, mission needs to the five planetary destinations with extreme entry environments. The Common Probe study involved four NASA Centers and addressed these issues, including constraints and inefficiencies that occur in specifying a common design.Study methodology: First, a notional payload of instruments for each destination was defined based on priority measurements from the Planetary Science Decadal Survey. Steep and shallow entry flight path angles (EFPA) were defined for each planet based on qualification and operational g-load limits for current, state-of-the-art instruments. Interplanetary trajectories were then identified for a bounding range of EFPA. Next, 3-DoF simulations for entry trajectories were run using the entry state vectors from the interplanetary trajectories. Aeroheating correlations were used to generate stagnation point convective and radiative heat flux profiles for several aeroshell shapes and entry masses. High fidelity thermal response models for various TPS materials were used to size stagnation point thicknesses, with margins based on previous studies. Backshell TPS masses were assumed based on scaled heat fluxes from the heatshield and also from previous mission concepts.

Hwang, Helen H.↗

Next Generation Thermal Protection System for Outer Planet Probes and Orbiter

Saturn Probe and Ice Giant Orbiter along with in-situ Probe Missions continue to be very high priority mis-sions. A result of the advocacy by OPAG and other Analysis Groups, the 3D Woven, Dual-Layer HEEET thermal protection system, mature at TRL 6, has closed the TPS gap for extreme environment missions. A mid density follow on to DL HEEET, developed to meet earth entry requirements, is a Single Layer vari-ant of the 3D woven TPS, which provides a mass effi-cient single layer 3D Mid-Density TPS (3MDCP) that has been baselined as the heatshield for MSR EEV. Continued development of 3MDCP will elevate it to TRL 6 by 2025. Conformal-PICA (C-PICA) devel-opment was pursued to establish a more efficient and robust alternate to PICA, and it is at TRL 4+. Our rationale for the next generation of TPS de-velopment is based on the on the missions needs of the next decade Outer Planet missions that are unique and more demanding than any other destinations. Taking advantage of the recent planned development of sev-eral materials, the next generation of TPS offers a much more mass efficient option for small, medium, and large class Outer Planet missions. Saturn Probes: While mission designers are gen-erally interested in shallow entry to maintain the g-load during entry around 50g, the heat-load for shallow entry can range between (100 kJ/cm2 – 300 kJ/cm2), two orders of magnitude higher than Venus or Sample Return missions. TPS must not only offer protection but must be mass efficient to perform reasonable sci-ence. TPS mass can quickly become 50% or more of the mass of the entire entry system. Recent analysis performed shows Saturn Probe missions could signifi-cantly benefit from the single layer HEEET (SL-HEEET/3MDCP). A DL-HEEET based heatshield mass could be ~ (40% -50%), SL-HEEET can provide additional (30% - 50%) mass savings. At the same time, C-PICA can provide (30% - 50%) mass savings on the backshell. The combined mass savings can be significant enough to carry an additional probe, if de-sired. Ice Giant Aerocapture Missions: Aerocapture mission architectures can provide significant ad-vantage over traditional propulsive insertion missions in multiple ways. 1) Reduced trip time ~ (4- 6) years (30% -40%), 2) Enables placing the orbiter, probe, and lander, all together and 3) Allows for greater science mass (probes and landers) due to mass efficiency. The delivery of a probe from orbit makes it easier and eliminates mission design constraints by HEEET for direct entry [4] of probes and allows for more targeted in-situ science once the Orbiter is able to collect data. In the past 20 years, progress made in GN&C for lift-guided entry missions (MSL, Orion EFT1, Mars 2020) and the expertise in blunt body aerodynamics at large scale (~ 5m) has led the EDL community to conclude that aerocapture is a “go do” engineering activity. An aerocapture mission that will deplete the excess energy of a fast arrival mission will require a mass efficient TPS that can handle extreme heat-load, ~ (100 kJ/cm2 – 500 kJ/cm2). Hence TPS, feasibility as well as mass efficiency requires assessment. Utilizing the recent developments, a comprehensive, bounding analysis was done to establish the potential for SOA (HEEET) system as well as emerging new TPS such as SL-HEEET and C-PICA. In this proposed poster, we will outline the process by which we establish bounding aerocapture trajecto-ries for hyperbolic excess velocities ranging from 27 km/s to 35 km/s, for low L/D (~ 0.4) configurations and determine conservative/bounding estimate of aer-othermal environment by using a combination of CFD simulations and stagnation point heating estimates [7]. This engineering approach allows us to assess the TPS need vs. TPS capability and determine the applicability of existing TPS. Once an applicable suite of TPS is determined, the TPS thickness and mass are comput-ed. We show that the TPS mass fraction can be as low as 5% to as high as 20%, depending on the use of ad-vanced TPS, while HEEET is sufficient but will require 50% of the entry mass.

E Venkatapathy↗

Air Data Probe Anomalies in Flight through Measured High Ice Water Content Conditions

High concentrations of ice crystals in convective storms have caused anomalous air temperature and airspeed readings during commercial and research flight operations. These anomalies occur when ice crystals are ingested in the heated probe inlet, melt or partially melt to liquid water, and then refreeze or remain in a liquid state depending on the probe heat and cloud conditions. In pitot probes, the refreezing may cause complete blockage of the total pressure, which causes airspeed anomalies. In total air temperature probes, the melted ice water may flow near the temperature sensing element and cause the total air temperature reading to approach 0 degree Celsius. During the High Ice Water Content (HIWC) RADAR and HIWC-2022 flight campaigns and the Convective Process Experiment (CPEX-CV) flight campaign, a total of 71 anomalies were recorded on the NASA DC-8 pitot probes when subjected to specific flight and cloud conditions. Similarly, a research TAT probe mounted near the pitot probes had 19 anomalies. This paper presents analyses of the measured natural conditions that led to these TAT and pitot anomalies, identifies two types of pitot probe anomalies, applies a concentration factor to estimate local TWC conditions near the TAT and pitot probes, and identifies the static air temperature and pressure altitude where the anomalies occurred on the Part 33 Appendix D envelope.

Aircraft Icing↗

Air Data Probe Anomalies in Flight through Measured High Ice Water Content Conditions

High concentrations of ice crystals in convective storms have caused anomalous air temperature and airspeed readings during commercial and research flight operations. These anomalies occur when ice crystals are ingested in the heated probe inlet, melt or partially melt to liquid water, and then refreeze or remain in a liquid state depending on the probe heat and cloud conditions. In pitot probes, the refreezing may cause complete blockage of the total pressure, which causes airspeed anomalies. In total air temperature probes, the melted ice water may flow near the temperature sensing element and cause the total air temperature reading to approach 0 degree Celsius. During the High Ice Water Content (HIWC) RADAR and HIWC-2022 flight campaigns and the Convective Process Experiment (CPEX-CV) flight campaign, a total of 71 anomalies were recorded on the NASA DC-8 pitot probes when subjected to specific flight and cloud conditions. Similarly, a research TAT probe mounted near the pitot probes had 19 anomalies. This paper presents analyses of the measured natural conditions that led to these TAT and pitot anomalies, identifies two types of pitot probe anomalies, applies a concentration factor to estimate local TWC conditions near the TAT and pitot probes, and identifies the static air temperature and pressure altitude where the anomalies occurred on the Part 33 Appendix D envelope.

Aircraft Icing↗

Stationary probe rotating disk electrode

A stationary probe having a probe holder and a probe with a probe tip. The stationary probe may be part of a stationary probe rotating disk electrode wherein the stationary probe has a passage therethrough for rotatably receiving a rotating disk electrode comprising a rotating shaft, rotatable about a longitudinal axis, and having an electrode portion extending therefrom configured to receive an electrode. The stationary probe rotating disk electrode may be part of an analytical system wherein the probe tip includes a capillary entrance spaced apart from the electrode and connected to an analyte flow path.

Lopes, Pietro Papa↗

Surface Charge Distribution Mapping Using an Electrostatic Probe

Undesired accumulation of charge on dielectric materials causing electrostatic discharges can be an issue in pulsed power systems and electrical systems in general. As such, an understanding of surface charge distribution, charge accumulation, and decay is required. An in-house no-contact electrostatic probe designed with a 2 mm resolution was fabricated to measure and map surface charge distribution. Designed as a contactless instrument, the probe consisting of a metal rod and low leakage amplifier circuit probes the electric potential near the surface. A scan of the surface then provides the raw data, a potential distribution. The actual probe response - i.e., the surface charge to voltage transfer function, is accounted for in post-processing. This is accomplished via an Inverse Wien Filter - a technique often applied in image processing - to deconvolve the probe response from the measured data. A commercially available electrostatic probe, the Trek 341B meter with a 3455ET probe, capable of measuring +/- 20 kV was compared to the in- house probe that is designed to cover a wider range from +/- 35 kV. A resolution better than the simple probe resolution is achieved through the distribution’s scanning voltage method and deconvolution. Applying repeated scans, surface charge decay was tracked on various polymer materials to determine the material and environment dependence; materials included were PA6, PTFE, and others. As an example of material dependence, samples charged to 20 kV at 65% humidity experience full charge decay in approximately 45 seconds for PA5 (152 mm dia.), while it took about 100 times longer for PTFE (51 mm dia.) to observe the same decay/redistribution of charge.

36 MATERIALS SCIENCE↗

Magnetically insulated baffled probe for real-time monitoring of equilibrium and fluctuating values of space potentials, electron and ion temperatures, and densities

By restricting the electron-collection area of a cold Langmuir probe compared to the ion-collection area, the probe floating potential can become equal to the space potential, and thus conveniently monitored, rather than to a value shifted from the space potential by an electron-temperature-dependent offset, i.e., the case with an equal-collection-area probe. This design goal is achieved by combining an ambient magnetic field in the plasma with baffles, or shields, on the probe, resulting in species-selective magnetic insulation of the probe collection area. This permits the elimination of electron current to the probe by further adjustment of magnetic insulation which results in an ion-temperature-dependent offset when the probe is electrically floating. Subtracting the floating potential of two magnetically insulated baffled probes, each with a different degree of magnetic insulation, enables the electron or ion temperature to be measured in real time.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

In-flight calibration of mesospheric rocket plasma probes

Many effects and factors can influence the efficiency of a rocket plasma probe. These include payload charging, solar illumination, rocket payload orientation and rotation, and dust impact induced secondary charge production. As a consequence, considerable uncertainties can arise in the determination of the effective cross sections of plasma probes and measured electron and ion densities. We present a new method for calibrating mesospheric rocket plasma probes and obtaining reliable measurements of plasma densities. This method can be used if a payload also carries a probe for measuring the dust charge density. It is based on that a dust probe's effective cross section for measuring the charged component of dust normally is nearly equal to its geometric cross section, and it involves the comparison of variations in the dust charge density measured with the dust detector to the corresponding current variations measured with the electron and/or ion probes. In cases in which the dust charge density is significantly smaller than the electron density, the relation between plasma and dust charge density variations can be simplified and used to infer the effective cross sections of the plasma probes. We illustrate the utility of the method by analysing the data from a specific rocket flight of a payload containing both dust and electron probes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Biasing, Acquisition and Interpretation of a Dense Langmuir Probe Array in NSTX

A dense array of 99 Langmuir probes has been installed in the lower divertor region of the National Spherical Torus Experiments (NSTX). This array is instrumented with a system of elec- tronics that allows flexibility in the choice of probes to bias as well as the type of measurement (including standard swept, single probe, triple probe and operation as passive floating potential and scrape-off-layer (SOL) current monitors). The use of flush-mounted probes requires careful inter- pretation. The time dependent nature of the SOL makes swept-probe traces difficult to interpret. To overcome these challenges, the single- and triple-Langmuir probe signals are used in comple- mentary fashion to determine the temperature and density at the probe location. A comparison to mid-plane measurements is made. Work is supported by DOE contracts DE-AC02-09CHI1466 and DE-PS02-07ER07-29.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Data Mining Empowers the Generation of a Novel Class of Chromosome-specific DNA Probes

Probes that allow accurate delineation of chromosome-specific DNA sequences in interphase or metaphase cell nuclei have become important clinical tools that deliver life-saving information about the gender or chromosomal make-up of a product of conception or the probability of an embryo to implant, as well as the definition of tumor-specific genetic signatures. Often such highly specific DNA probes are proprietary in nature and have been the result of extensive probe selection and optimization procedures. We describe a novel approach that eliminates costly and time consuming probe selection and testing by applying data mining and common bioinformatics tools. Similar to a rational drug design process in which drug-protein interactions are modeled in the computer, the rational probe design described here uses a set of criteria and publicly available bioinformatics software to select the desired probe molecules from libraries comprised of hundreds of thousands of probe molecules. Examples describe the selection of DNA probes for the human X and Y chromosomes, both with unprecedented performance, but in a similar fashion, this approach can be applied to other chromosomes or species.

60 APPLIED LIFE SCIENCES↗

PNA-COMBO-FISH: From combinatorial probe design in silico to vitality compatible, specific labelling of gene targets in cell nuclei

Recently, advantages concerning targeting specificity of PCR constructed oligonucleotide FISH probes in contrast to established FISH probes, e.g. BAC clones, have been demonstrated. These techniques, however, are still using labelling protocols with DNA denaturing steps applying harsh heat treatment with or without further denaturing chemical agents. COMBO-FISH (COMBinatorial Oligonucleotide FISH) allows the design of specific oligonucleotide probe combinations in silico. Thus, being independent from primer libraries or PCR laboratory conditions, the probe sequences extracted by computer sequence data base search can also be synthesized as single stranded PNA-probes (Peptide Nucleic Acid probes). Gene targets can be specifically labelled with at least about 20 PNA-probes obtaining visibly background free specimens. By using appropriately designed triplex forming oligonucleotides, the denaturing procedures can completely be omitted. These results reveal a significant step towards oligonucleotide-FISH maintaining the 3D-nanostructure and even the viability of the cell target. The method is demonstrated with the detection of Her2/neu and GRB7 genes, which are indicators in breast cancer diagnosis and therapy. - Highlights: • Denaturation free protocols preserve 3D architecture of chromosomes and nuclei. • Labelling sets are determined in silico for duplex and triplex binding. • Probes are produced chemically with freely chosen backbones and base variants. • Peptide nucleic acid backbones reduce hindering charge interactions. • Intercalating side chains stabilize binding of short oligonucleotides.

60 APPLIED LIFE SCIENCES↗

Data-Driven Discovery of Linear Molecular Probes with Optimal Selective Affinity for PFAS in Water

Approaches to tackle the wide and growing variety of highly persistent per- and polyfluoroalkyl substances (PFAS) are of pressing global need because of their detrimental human health effects, such as cancer, birth defects, and hormone imbalance. Sensitive, selective, and easy-to-use real-time sensors to monitor and detect PFAS and sorbents to extract them are critical to meeting government-mandated environmental concentrations. In this work, we combine all-atom molecular dynamics simulations, enhanced sampling, deep representational learning, and Bayesian optimization to perform high-throughput virtual screening for highly sensitive and selective molecular probes. Our molecular design space consists of 3850 linear hydrocarbon chains with varying degrees of halogenation with and without amine- and phosphine-based headgroups. By employing a data-driven search process, we efficiently explore the molecular design space to optimize the sensitivity to perfluorooctanesulfonic acid (PFOS) as a prototypical PFAS analyte and selectivity relative to a sodium dodecyl sulfate (SDS) interferent. We calculate 504 Gibbs free energies of probe-analyte and probe-interferent interactions and identify probes with PFOS association free energies of up to (-ΔG PFOS ) = 9.8 ± 0.2 kJ/mol and selectivities relative to SDS of (-ΔΔG PFOS–SDS ) = 3.1 ± 1.5 kJ/mol. A C 11 Br 23 P(CH 3 ) 2 probe containing 11 backbone brominated carbons and a tertiary phosphine headgroup possesses the most sensitive binding constant to PFOS within the defined search space of K b PFOS = 177.4 ± 12.7, and a semibrominated probe C 5 H 11 C 7 Br 14 N(CH 3 ) 2 containing 12 backbone carbons and a tertiary amine headgroup possesses the highest selectivity relative to SDS of K b PFOS /K b SDS = 4.6 ± 1.7. A retrospective analysis of our data to extract interpretable design rules reveals that the sensitivity of linear hydrogenated probes increases by approximately 1 kJ/mol per C–C bond. The addition or removal of halogen atoms and amine or phosphine headgroups produces nonmonotonic changes in both sensitivity and selectivity with changes to the sensitivity of up to 2.5 kJ/mol. Finally, this work places empirical limitations on the performance of a wide range of linear probes for PFOS detection and offers a generic strategy for high-throughput computational screening to promote selective and sensitive binding.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The Interplay of Pauli Repulsion, Electrostatics, and Field Inhomogeneity for Blueshifting and Redshifting Vibrational Probe Molecules

Many molecules' vibrational frequencies are sensitive to intermolecular electric fields, enabling them to probe the field in complex molecular environments. However, it is often unclear whether the probe is responding to the local electric field or other types of intermolecular interactions, inhibiting interpretation of the frequency and effectiveness as probes. This is especially true for molecules whose vibrational frequencies blueshift instead of the more typical redshift in hydrogen bonding configurations. In this work, we computationally investigate the causes of redshifting versus blueshifting over a range of vibrational reporters. First, we apply adiabatic energy decomposition analysis to a paradigmatic set of probes, finding that redshifting only occurs when electrostatic interactions are strong enough to overcome the dominant and large blueshifting contribution of Pauli repulsion. Furthermore, we demonstrate that field inhomogeneity can further shift the frequency of many probes substantially to either reinforce or counteract the shift expected from a homogeneous field. We find that redshifting is reinforced by electric field inhomogeneity, otherwise field inhomogeneity further weakens the electrostatic contribution relative to Pauli repulsion, leading to blueshifting. Further calculations indicate that the probe's response to field inhomogeneity can be understood by considering the mass of the atoms involved in the stretching mode and sign of the electric field. In explaining the interplay of different intermolecular interactions and field inhomogeneity for many probes, our results should enable the use and interpretation of spectroscopic probes and their connection to electric fields in more complex systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Wall scanning probe for high-field side plasma measurements on Alcator C-Mod

A new, high-field side scanning probe has been added to Alcator C-Mod's complement of edge diagnostics. The wall scanning probe is designed to provide all the benefits of a linear plunge, multielectrode scanning probe while working from the confined space of the inner tokamak wall. The drive mechanism is an embedded coil which produces a torque with the ambient toroidal magnetic field when energized, thus allowing the probe to plunge to different preprogramed depths at different times during a plasma discharge. The probe tip is designed for easy replacement and is presently configured to operate as a modified, high heat-flux ''Gundestrup-type'' probe with four tungsten electrodes. The probe has demonstrated the ability to obtain cross-field profiles for electron temperature, density, floating potential, and plasma flow information (parallel and perpendicular to B) up to a depth of a few millimiters inside the last-closed flux surface in standard C-Mod discharges. The tungsten-tipped probe has proved very robust and shows little or no damage though it routinely handles surface heat fluxes on the order of 100 MW/m{sup 2} at peak insertion.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Biasing, acquisition, and interpretation of a dense Langmuir probe array in NSTX

A dense array of 99 Langmuir probes has been installed in the lower divertor region of the National Spherical Torus Experiment (NSTX). This array is instrumented with a system of electronics that allows flexibility in the choice of probes to bias as well as the type of measurement (including standard swept, single probe, triple probe, and operation as passive floating potential and scrape-off-layer SOL current monitors). The use of flush-mounted probes requires careful interpretation. The time dependent nature of the SOL makes swept-probe traces difficult to interpret. To overcome these challenges, the single- and triple-Langmuir probe signals are used in complementary fashion to determine the temperature and density at the probe location. A comparison to midplane measurements is made.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Novel rotating field probe for inspection of tubes

Inspection of steam generator tubes in nuclear power plants is extremely critical for safe operation of the power plant. In the nuclear industry, steam generator tube inspection using eddy current techniques has evolved over the years from a single bobbin coil, to rotating probe coil (RPC) and array probe, in an attempt to improve the speed and reliability of inspection. The RPC probe offers the accurate spatial resolution but involves complex mechanical rotation. This paper presents a novel design of eddy current probes based on rotating fields produced by three identical coils excited by a balanced three-phase supply. The sensor thereby achieves rotating probe functionality by electronic means and eliminates the need for mechanical rotation. The field generated by the probe is largely radial that result in induced currents that flow circularly around the radial axis and rotating around the tube at a synchronous speed effectively producing induced eddy currents that are multidirectional. The probe will consequently be sensitive to cracks of all orientations in the tube wall. The finite element model (FEM) results of the rotating fields and induced currents are presented. A prototype probe is being built to validate simulation results.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Scanning ion sensitive probe for plasma profile measurements in the boundary of the Alcator C-Mod tokamak

A new Ion Sensitive Probe head has been created for the outer-midplane scanning probe system on the Alcator C-Mod tokamak. The new probe head contains three elements: an ion sensitive probe to measure ion temperature and plasma potential, a Langmuir probe to measure electron temperature, density, and floating potential, and a second Langmuir probe to measure ion saturation current and the density fluctuations arising from ''blob'' events. The ion sensitive probe current is normalized to this measurement to reduced deleterious effects of the strong fluctuations. Design of the high heat flux probe (>100 MW/m{sup 2}) and initial results are presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A variable-width harmonic probe for multifrequency atomic force microscopy

In multifrequency atomic force microscopy (AFM) to simultaneously measure topography and material properties of specimens, it is highly desirable that the higher order resonance frequencies of the cantilever probe are assigned to be integer harmonics of the excitation frequency. The harmonic resonances are essential for significant enhancement of the probe's response at the specified harmonic frequencies. In this letter, a structural optimization technique is employed to design cantilever probes so that the ratios between one or more higher order resonance frequencies and the fundamental natural frequency are ensured to be equal to specified integers and, in the meantime, that the fundamental natural frequency is maximized. Width profile of the cantilever probe is the design variable in optimization. Thereafter, the probes were prepared by modifying a commercial probe through the focused ion beam (FIB) milling. The resonance frequencies of the FIB fabricated probes were measured with an AFM. Results of the measurement show that the optimal design of probe is as effective as design prediction.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗