Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PPb”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Changes in Anthropogenic Precursor Emissions Drive Shifts in the Ozone Seasonal Cycle Throughout the Northern Midlatitude Troposphere

Simulations by six Coupled Model Intercomparison Project Phase 6 (CMIP6) Earth system models indicate that the seasonal cycle of baseline tropospheric ozone at northern midlatitudes has been shifting since the mid-20th century. Beginning in ∼ 1940, the magnitude of the seasonal cycle increased by ∼10 ppb (measured from seasonal minimum to maximum), and the seasonal maximum shifted to later in the year by about 3 weeks. This shift maximized in the mid-1980s, followed by a reversal – the seasonal cycle decreased in amplitude and the maximum shifted back to earlier in the year. Similar changes are seen in measurements collected from the 1970s to the present. The timing of the seasonal cycle changes is generally concurrent with the rise and fall of anthropogenic emissions that followed industrialization and the subsequent implementation of air quality emission controls. A quantitative comparison of the temporal changes in the ozone seasonal cycle at sites in both Europe and North America with the temporal changes in ozone precursor emissions across the northern midlatitudes found a high degree of similarity between these two temporal patterns. We hypothesize that changing precursor emissions are responsible for the shift in the ozone seasonal cycle; this is supported by the absence of such seasonal shifts in southern midlatitudes where anthropogenic emissions are much smaller. We also suggest a mechanism by which changing emissions drive the changing seasonal cycle: increasing emissions of NOx allow summertime photochemical production of ozone to become more important than ozone transported from the stratosphere, and increasing volatile organic compounds (VOCs) lead to progressively greater photochemical ozone production in the summer months, thereby increasing the amplitude of the seasonal ozone cycle. Decreasing emissions of both precursor classes then reverse these changes. The quantitative parameter values that characterize the seasonal shifts provide useful benchmarks for evaluating model simulations, both against observations and between models.

Ozone↗

Contamination, Transportation or Transmutation in LENR Material Analyses

LENR experiments using various loading and triggering mechanisms rely on a variety of elemental and isotopic assays to determine LENR effects. These assays include optical microscopy, Scanning Electron Microscopy with Energy Dispersive X-Ray Analysis (SEM/EDX), X-Ray Photoelectron Spectroscopy (XPS) and Transmission Electron Microscopy (TEM). All of these methods observe the surface of a material. By dissolving or vaporizing the sample, Inductively Coupled Plasma Optical Element Spectroscopy (ICP-OES) can determine elemental composition (ppb) or with mass spectroscopy, isotopes (ICP/MS). One can use a focused ion beam (FIB) to cut open a sample and observe the “cut” with either SEM/EDX, or Time-of-Flight Secondary Ion Mass Spectroscopy (TOF-SIMS). High Purity Gamma Ray Spectroscopy (HPGe) and alpha/ beta Liquid Scintillator spectroscopy can be used. We’ve employed these assay methods in our NASA GRC research under both the Advanced Energy Conversion and Lattice Confinement Fusion Projects. However, there are limitations associated with each of these methods ranging from handling contamination, instrumental limitations including sensitivity and field of view, and sample preparation.

Low Energy Nuclear Reactions↗

High Sensitive and Low Power Nanosensors for Space and Terrestrial Applications

Nanotechnology offers the ability to work at the molecular level, atom by atom, to create large structures with fundamentally new molecular organization. It is essentially concerned with materials, devices, and systems whose structures and components exhibit novel and significantly improved physical, chemical and biological properties, phenomena, and process control due to their nanoscale size. A nanosensor technology has been developed at NASA Ames using nanostructure, single walled carbon nanotubes (SWNTs). The nanosensors have achieved low detection limit of chemicals in the concentration range of ppm to ppb. Due to large surface area, low surface energy barrier and high thermal and mechanical stability, nanostructured chemical sensors offer higher sensitivity, lower power consumption and a more robust solution than most state-of-the-art systems making them attractive for space and terrestrial applications. An example of a sensor module, the first space flown nano device, will be introduced in this presentation. Such sensors have drawn attention from space community for global weather monitoring, space exploration, life search in the universe, and launch pad fuel leak detection and in-flight cabin air and life support system monitoring, and engine operation monitoring. Additionally, the wireless capability of such sensors can be leveraged to network mobile and fixed-base detection and warning systems for civilian population centers, military bases and battlefields, as well as other high-value or high-risk assets and areas in industry.

Jing Li↗

Phosphine in the Venusian Atmosphere: A Strict Upper Limit from SOFIA GREAT Observations

The presence of phosphine (PH3) in the atmosphere of Venus was reported by Greaves et al. based on observations of the J = 1–0 transition at 267 GHz using ground-based, millimeter-wave spectroscopy. This unexpected discovery presents a challenge for our understanding of Venus's atmosphere, and has led to a reappraisal of the possible sources and sinks of atmospheric phosphorous-bearing gases. Here we present results from a search for PH3 on Venus using the German REceiver for Astronomy at Terahertz Frequencies instrument aboard the Stratospheric Observatory for Infrared Astronomy aircraft, over three flights conducted in November 2021. Multiple PH3 transitions were targeted at frequencies centered on 533 and 1,067 GHz, but no evidence for atmospheric PH3 was detected. Through radiative transfer modeling, we derived a disk-averaged upper limit on the PH3 abundance of 0.8 ppb in the altitude range 75–110 km, which is more stringent than previous ground-based studies.

M. A. Cordiner↗

Mineral-Catalysed Formation of Marine NO and N 2 O on the Anoxic Early Earth

Microbial denitrification converts fixed nitrogen species into gases in extant oceans. However, it is unclear how such transformations occurred within the early nitrogen cycle of the Archean. Here 5we present experimental anoxic surface-catalyzed reduction of nitrite and nitrate via green rust and magnetite combined with diffusion and photochemical modeling. We find that in a Fe 2+ -rich marine environment, Fe minerals could have catalyzed abiotic denitrification reactions leading to the formation of nitric oxide (NO) and nitrous oxide (N 2 O). Nitrate did not exhibit reactivity in the presence of either mineral or aqueous Fe2+, however, both minerals induced rapid nitrite reduction 10to NO and N 2 O. While N 2 O escaped into the atmosphere (63% of nitrite-nitrogen, with green rust as catalyst), NO remained associated with precipitates (7%) serving as a potential shuttle to the benthic ocean.The modeling suggests that marine N 2 O emissions would have sustained 0.8-6 ppb of atmospheric N 2 O without a protective ozone layer. Our findings add detail to the as yet incompletely documented Archean nitrogen cycle, implying a globally distributed process driven 15by chemical kinetics similar to those of modern enzymatically mediated conversions.

Steffen Buessecker↗

Electronic Nose Development and Preliminary Human Breath Testing for Rapid, Non-Invasive COVID-19 Detection

We adapted an existing, spaceflight-proven, robust “electronic nose” (E-Nose) that uses an array of electrical resistivity-based nanosensors mimicking aspects of mammalian olfaction to conduct on-site, rapid screening for COVID-19 infection by measuring the pattern of sensor responses to volatile organic compounds (VOCs) in exhaled human breath. We built and tested multiple copies of a hand-held prototype E-Nose sensor system, composed of 64 chemically sensitive nanomaterial sensing elements tailored to COVID-19 VOC detection; data acquisition electronics; a smart tablet with software (App) for sensor control, data acquisition and display; and a sampling fixture to capture exhaled breath samples and deliver them to the sensor array inside the E-Nose. The sensing elements detect the combination of VOCs typical in breath at parts-per-billion (ppb) levels, with repeatability of 0.02% and reproducibility of 1.2%; the measurement electronics in the E-Nose provide measurement accuracy and signal-to-noise ratios comparable to benchtop instrumentation. Preliminary clinical testing at Stanford Medicine with 63 participants, their COVID-19-positive or COVID-19-negative status determined by concomitant RT-PCR, discriminated between these two categories of human breath with a 79% correct identification rate using “leave-one-out” training-and-analysis methods. Analyzing the E-Nose response in conjunction with body temperature and other non-invasive symptom screening using advanced machine learning methods, with a much larger database of responses from a wider swath of the population, is expected to provide more accurate on-the-spot answers. Additional clinical testing, design refinement, and a mass manufacturing approach are the main steps toward deploying this technology to rapidly screen for active infection in clinics and hospitals, public and commercial venues, or at home.

COVID-19↗

Measurement Report :Emission Factors of NH3 and NHx for Wildfires and Agricultural Fires in the United States

During the 2019 Fire Influence on Regional to Global Environments and Air Quality (FIREX-AQ) study, the NASA DC-8 carried out in situ chemical measurements in smoke plumes emitted from wildfires and agricultural fires in the contiguous United States. The DC-8 payload included a modified proton-transfer-reaction time-of-flight mass spectrometer (PTR-ToF-MS) for the fast measurement of gaseous ammonia (NH 3 ) and a high-resolution time-of-flight aerosol mass spectrometer (AMS) for the fast measurement of submicron particulate ammonium (NH 4 + ). We herein report data collected in smoke plumes emitted from 6 wildfires in the Western United States, 2 prescribed grassland fires in the Central United States, 1 prescribed forest fire in the Southern United States, and 66 small agricultural fires in the Southeastern United States. Smoke plumes contained double to triple digit ppb levels of NH 3 . In the wildfire plumes, a significant fraction of NH 3 had already been converted to NH 4 + at the time of sampling (≥2 h after emission). Substantial amounts of NH 4 + were also detected in freshly emitted smoke from corn and rice field fires. We herein present a comprehensive set of emission factors of NH 3 and NH x , with NH x = NH 3 + NH 4 + . Average NH 3 and NH x emission factors for wildfires in the Western United States were 1.86±0.75 g kg −1 and 2.47±0.80 g kg −1 of fuel burned, respectively. Average NH 3 and NH x emission factors for agricultural fires in the Southeastern United States were 0.89±0.58 and 1.74±0.92 g kg −1 , respectively. Our data show no clear inverse correlation between modified combustion efficiency (MCE) and NH 3 emissions. The observed NH 3 emissions were significantly higher than measured in previous laboratory experiments in the FIREX FireLab 2016 study.

Laura Tomsche↗

Evaluation of the Interference of Tenax®TA Adsorbent With Dimethylformamide Dimethyl Acetal Reagent for Gas Chromatography-Dragonfly Mass Spectrometry and Future Gas Chromatography-Mass Spectrometry in Situ Analysis

Among future space missions, national aeronautics and space administration (NASA) selected two of them to analyze the diversity in organic content within Martian and Titan soil samples using a gas chromatograph – mass spectrometer (GC–MS) instrument. The Dragonfly space mission is planned to be launched in 2027 to Titan's surface and explore the Shangri-La surface region for years. One of the main goals of this mission is to understand the past and actual abundant prebiotic chemistry on Titan, which is not well characterized yet. The ExoMars space mission is planned to be launched in 2028 to Mars’ surface and explore the Oxia Planum and Mawrth Vallis region for years. The main objectives focus on the exploration of the subsurface soil samples, potentially richer in organics, that might be relevant for the search of past life traces on Mars where irradiation does not impact the matrices and organics. One recently used sample pre-treatment for gas chromatography – mass spectrometry analysis is planned on both space missions to detect refractory organic molecules of interest for astrobiology. This pre-treatment is called derivatization and uses a chemical reagent – called dimethylformamide dimethyl acetal (DMF-DMA) – to sublimate organic compounds keeping them safe from thermal degradation and conserving the chirality of the molecules extracted from Titan or Mars’ matrices. Indeed, the detection of building blocks of life or enantiomeric excess of some organics (e.g. amino acids) after DMF-DMA pre-treatment and GC–MS analyses would be both bioindicators. The main results highlighted by our work on DMF-DMA and Tenax®TA interaction and efficiency to detect organic compounds at ppb levels in a fast and single preparation are first that Tenax®TA did not show the onset of degradation until after 150 experiments – a 120 h at 300 °C experiment – which greatly exceeds the experimental lifetimes for the DraMS and GC-space in situ investigations. Tenax®TA polymer and DMF-DMA produce many by-products (about 70 and 46, respectively, depending on the activation temperature). Further, the interaction between the two leads to the production of 22 additional by-products from DMF-DMA degradation, but these listed by-products do not prevent the detection of trace-level organic molecules after their efficient derivatization and volatilization by DMF-DMA in the oven ahead the GC–MS trap and column.

DraMS-Dragonfly mission↗

Primordial Aqueous Alteration Recorded in Water-Soluble Organic Molecules from the Carbonaceous Asteroid (162173) Ryugu

We report primordial aqueous alteration signatures in water-soluble organic molecules from the carbonaceous asteroid (162173) Ryugu by the Hayabusa2 spacecraft of JAXA. Newly identified low-molecular-weight hydroxy acids (HO-R-COOH) and dicarboxylic acids (HOOC-R-COOH), such as glycolic acid, lactic acid, glyceric acid, oxalic acid, and succinic acid, are predominant in samples from the two touchdown locations at Ryugu. The quantitative and qualitative profiles for the hydrophilic molecules between the two sampling locations shows similar trends within the order of ppb (parts per billion) to ppm (parts per million). A wide variety of structural isomers, including α- and β-hydroxy acids, are observed among the hydrophilic molecules. We also identify pyruvic acid and dihydroxy and tricarboxylic acids, which are biochemically important intermediates relevant to molecular evolution, such as the primordial TCA (tricarboxylic acid) cycle. Here, we find evidence that the asteroid Ryugu samples underwent substantial aqueous alteration, as revealed by the presence of malonic acid during keto–enol tautomerism in the dicarboxylic acid profile. The comprehensive data suggest the presence of a series for water-soluble organic molecules in the regolith of Ryugu and evidence of signatures in coevolutionary aqueous alteration between water and organics in this carbonaceous asteroid.

Asteroids, comets and Kuiper belt↗

Morphology and Luminescence Properties of Transition Metal Doped Zinc Selenide Crystals

Zinc selenide is an excellent matrix material to dope with rare-earth and transition metal to achieve mid-infrared luminescence to develop high power lasers. The luminescence, morphology and refractive index is significantly affected by the doping and defects generated due to size and valency of dopants, concentration, growth process and convection during the growth. The aim of the study is to investigate effect of point and line defects generated due to low doping of iron and chromium on the emission and morphology of the zinc selenide. Luminescence and morphological properties of large iron and chromium doped zinc selenide single crystals were studied to evaluate the effect of extremely low residual impurities and defects associated with the doping process. The emission properties following both short wavelength (i.e., ultraviolet; 350 – 370 nm) excitation and longer wavelength (i.e., near infrared; 850 – 870 nm) excitation were characterized. Luminescence emission bands were identified in both doped crystals. In addition to the primary emission bands, satellite peaks and intra-center transitions were also observed. Due to local population defects associated with the residual impurities (ppm to ppb) in the Fe-ZnSe and Cr-ZnSe crystals, peak emission wavelengths were observed to shift. Raman studies using 266 and 532 – nm excitation revealed different positions of longitudinal and transverse peaks for Fe-ZnSe and Cr-ZnSe crystals, associated with different levels of defects due to the different ion sizes. The emission bands were found to decrease in intensity due to recombination of residual impurity co-dopants and complex defects generated during growth and fabrication. Cryogenic temperature analyses revealed a very clean emission band due to freezing of some of the point and line defects. An emission band observed at 980 nm for both crystals at room temperature as well as cryogenic temperatures indicates a vibronic peak in ZnSe. The scanning electron microscopy (SEM) images of the local morphology support the conclusion that small crystallites in doped crystals are also present.

Zinc selenide↗

Neutron Skin Measurement of208Pb Using Parity-Violating Electron Scattering

Nuclear stability requires large nuclei to have more neutrons than protons. While the central core of the nucleus is composed of symmetric nuclear matter, the extra neutrons in heavy nuclei are pushed out to the surface of the nucleus, forming a pure outer neutron skin layer. While the proton distribution inside a nucleus has been accurately measured using electromagnetic probes, previous measurements of neutron distributions in complex nuclei have suffered a lack of systematic precision. PREX-2 and CREX use Parity-Violating electron Scattering (PVeS), as an electroweak interaction probe, to measure the neutron distributions in208Pb and48Ca, respectively. Making use of elastic scattering of longitudinally polarized electrons from unpolarized (isotopically pure) targets, PREX-2 and CREX measure the asymmetry in scattering rates between opposite beam polarization states. Since both experiments share the same exact measurement concept and apparatus, much of this dissertation applies to both PREX-2 and CREX. However, the presented asymmetry analysis and neutron skin extraction are only for PREX-2. PREX-2 measures the parity-violating asymmetry, APV, for 953 MeV electrons scattered elastically from208Pb at?5°in the lab. The final result is APV= 550.00±16.09(stat.)±8.16(syst.)ppb. From this measurement, we report the neutron skin thickness in208Pb nuclei to be, Rskin= 0.278±0.078(exp.)±0.012(model) fm. This measurement has broad implications throughout the physics community, increasing our knowledge in neutron star structure, the equation of state of nuclear matter, nuclear baryon density, nuclear electric dipole polarizability, and more. Key Words: Neutron skin, electroweak interaction, PREX-2, CREX, parity-violating asymmetry, neutron star, quartz detector, weak charge radius, symmetry energy, Hall A, Jefferson Lab

Adhikari, Devi↗

Specialized diamond materials for NMR applications

Polarizable diamond materials and methods for obtaining nuclear magnetic resonance spectra of samples external to the diamond materials are described. The diamond materials can include 12C, 13C, substitutional nitrogen, and nitrogen vacancy defects in a crystalline lattice, wherein the substitutional nitrogen concentration is between 10 ppm and 200 ppm, the nitrogen vacancy concentration is between 10 ppb and 10 ppm, and the 13C concentration is greater than 1.1% and not more than 25%. Methods for obtaining nuclear magnetic resonance spectra can include optically pumping a diamond material to generate electron spin hyperpolarization in nitrogen vacancy centers, transferring the electron spin hyperpolarization to nuclei of the sample, and generating a nuclear magnetic resonance spectrum by applying a magnetic field to the sample, exciting the sample with a radio frequency pulse, and detecting a nuclear magnetic resonance response from the sample.

Parker, Alfred↗

Search for CPT and Lorentz invariance violation in the muon $g -2$ experiment at Fermilab

The Muon g-2 experiment at Fermilab (E989) aims to measure the anomalous magnetic moment of the muon, $a_{\mu}= (g-2)/2$, to a groundbreaking precision of $140$ ppb, obtaining a near four-fold increase in precision over the previous experiment, E821, at the Brookhaven National Laboratory (BNL). The value of $a_{\mu}$ from BNL currently differs from the Standard Model prediction by $\sim 3.7$ standard deviations, suggesting the potential for new physics and therefore, motivating a new experiment.Because the theory predicts this number with high precision, testing the g-factor through experiment provides a stringent test of the SM and can suggest physics beyond the Standard Model. The goal of the Fermilab Muon $g-2$ experiment is to increase the statistical precision by more than a factor of 20 and reduce systematic errors by a factor of 3. By measuring muon precession rate ($\omega_a$) in an external magnetic field, the anomalous magnetic moment will be calculated. This is an incredibly challenging experiment with a unique opportunity to provide new insight into nature. \\ The $g-2$ data also provides a great opportunity for setting the most stringent limits on some of the Standard Model Extension CPT Lorentz violating (LV) parameters in the muon sector. One of the CPT and Lorentz violating signatures that we can look for using $g-2$ data is a sidereal variation of $\omega_a(t)$. Extensive simulation studies confirm that the sensitivity regarding the sidereal varation roughly scales with $\omega_a$ uncertainty. Hence, the $g-2$ experiment at FNAL should be able to reach limits of $\sim 5\times10^{-25}$ GeV. Because the CPT and LV analyses are essentially studies of variations in $\omega_a$ as a function of time and charge, performing an $\omega_a$ analysis sets the stage for the CPT and LV measurement. This dissertation focuses on the methodology of a fully functioning framework and analyzing the Fermilab Muon $g - 2$ Run 2 data containing $\sim 11$ billion events above an energy threshold of $1.7$~GeV.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Muon Campus at Fermilab

The Muon Campus at Fermilab provides world class accelerator infrastructure supporting the next generation intensity frontier experiments. The anti-proton source from the Tevatron era was converted to the present day Muon Campus at the end of the collider program in 2011. Currently, the Muon Campus delivers highly polarized muon beams to the Muon g-2 experiment and in a few years, it will provide muon beams to the Mu2e experiment. The Muon g-2 experiment is a high precision test of the standard model; it is precise enough to measure QED, Weak, and QCD Standard Model contributions.The Muon g-2 experiment looks for a significant deviation from the Standard Model whereas the Mu2e experiment looks for rare processes using high intensity muon beams. The Muon g-2 experiment has measured the anomalous magnetic moment of muons to an unprecedented 460 ppb precision with Run 1 data. The experiment has completed 5 runs, accumulating 19$\times$ Brookhaven E821 data set. The Mu2e experiment has completed the construction phase and first beam to the Diagnostic Absorber was run on April 14, 2022. Installation and commissioning of the Mu2e experiment will begin in 2023 and beam commissioning and physics run is currently planned for 2026.

43 PARTICLE ACCELERATORS↗

Effect of Water Chemistry on Crack Growth Rate in Neutron Irradiated X-750 and XM-19

The Advanced Test Reactor (ATR) National Science User Facility (NSUF) was used to study the effect of neutron damage on crack growth rates (CGR) under simulated boiling water reactor (BWR) water chemistry conditions using a fast neutron spectrum to accelerate the damage process. Nickel based Alloy X-750 and XM-19 were irradiated in the ATR center flux trap (CFT), with this experiment marking the first civilian project to utilize this position within the reactor. 0.4T-CT specimens were used to study crack growth rates for two sample fluences (~1.9 x 1020 n/cm2 and ~9.5 x 1020 n/cm2, E > 1MeV)) in both normal water chemistry (NWC) at 2.5 ppm O2 and hydrogen water chemistry (HWC) at ~80 ppb H2. CGR testing was conducted at a temperature of 288 °C. A decrease in CGR was observed for both alloys with the average ratio (CGR in NWC/CGR in HWC) being a factor of 281 for the XM-19 samples and a factor of 27.8 for the X-750 samples. Observed CGRs in this study showed little difference compared to non-irradiated samples (the non-irradiated XM-19 was 20% cold worked), suggesting limited sensitivity of these susceptible alloys to irradiation effects. Detailed results of CGR response to varying environmental electrochemical potential (ECP) and water purity will be presented in the context of crack growth mitigation in different water chemistries and the change in material behavior relative to non-irradiated samples of the material.

36 MATERIALS SCIENCE↗

Effect of Water Chemistry on Crack Growth Rates in Neutron Irradiated X-750 and XM-19

The Advanced Test Reactor (ATR) National Science User Facility (NSUF) was used to study the effect of neutron damage on crack growth rates (CGR) under simulated boiling water reactor (BWR) water chemistry conditions using a fast neutron spectrum to accelerate the damage process. Nickel based Alloy X-750 and XM-19 were irradiated in the ATR center flux trap (CFT), with this experiment marking the first civilian project to utilize this position within the reactor. 0.4T-CT specimens were used to study crack growth rates for two sample fluences (~1.9 x 1020 n/cm2 and ~9.5 x 1020 n/cm2, E > 1MeV) in both normal water chemistry (NWC) at 2.5 ppm O2 and hydrogen water chemistry (HWC) at ~80 ppb H2. A decrease in CGR was observed with HWC for both alloys with the average ratio (CGR in NWC/CGR in HWC) being a factor of 281 for the XM-19 samples and a factor of 27.8 for the X-750 samples. Observed CGRs in this study showed little difference compared to non-irradiated samples (the non-irradiated XM-19 was 20% cold worked), suggesting limited sensitivity of these susceptible alloys to irradiation effects. The CGR response to varying environmental electrochemical potential (ECP) and water purity will be presented.

36 MATERIALS SCIENCE↗

THE POTENTIAL FOR REUSE OF PRODUCED WATER IN THE CRITICAL MINERALS SUPPLY CHAIN IN THE POWDER RIVER BASIN OF WYOMING AND MONTANA

The Powder River Basin (PRB) Carbon Ore, Rare Earth, and Critical Minerals (CORE-CM) project is part of the Department of Energy sponsored CORE-CM initiative focused on domestic production of critical minerals and promoting economic development in traditionally fossil fuel producing basins. An important part of this project is regional assessment of waste streams and development of basinal strategies for waste stream reuse within the critical minerals (CM) supply chain. The availability of water for all parts of the CM supply chain is of particular concern in the arid mountain west. In the Wyoming PRB, average annual production of produced water (PW) by the oil and gas industry is more than 16 billion gallons (2015-2022). Through published data and engagement with industry partners, we conducted a preliminary investigation of PW in the PRB to understand volumes, quality, and the potential for use in the CM supply chain. PW was assessed for potential as a direct feedstock and for use in CM processing of a variety of conventional and unconventional feedstocks, including ore from the Bear Lodge Alkaline Complex, coal, and coal byproducts. Preliminary findings suggest that PRB PW contains significantly lower concentrations of rare earth elements (REE) and lithium than would be considered economic at this time. For example, concentrations of REE+Sc measured in PRB PW are <1 ppb (DE-EE0007603), and only seven PRB PW samples reported in the USGS PW database had lithium concentrations ≥50 ppm. However, enrichment of CM in residual brine and sludge from PW evaporation and solidification treatment ponds may yield concentrations of interest over a pond lifetime and should be considered in future studies. Coal bed methane (CBM) PW accounted for 42% of all PW in the Wyoming PRB in 2022. Compared to non-CBM PW, PRB CBM water quality generally meets standards allowing surface discharge and reuse in local industries such as livestock. CBM PW may help to fill water needs within the CM supply chain. Understanding the distribution of CBM PW that is discharged versus reused will help develop basinal reuse strategies.

Jackson, Lily↗

Probabilistic Groundwater Modeling of the RDX Plume at Los Alamos National Laboratory to Support Risk Assessment - 20359

A plume of the contaminant hexahydro-1,3,5-trinitro-1,3,5-triazine (RDX) with concentrations greater than the New Mexico tap water drinking standard (9.66 ppb) is present in the regional aquifer near the southwestern boundary of Los Alamos National Laboratory (LANL). A risk assessment is performed for exposure to regional aquifer groundwater, with long-term predictions of RDX concentrations provided by a calibrated, probabilistic, numerical fate and transport model. The structure of the model is hierarchical, with the RDX Regional Aquifer (RA) groundwater model acting as the primary tool for analysis of downgradient RDX concentrations. The RA model is deeply informed by the conceptual site model (CSM) and is calibrated using site RDX concentration data and hydraulic head measurements, along with other analyses. The model is calibrated using data through December 2019. Where data are scarce other lines of evidence are used to inform inputs, including the multiphase RDX Vadose Zone (VZ) model and Pipe and Disk analytical screening tool. Model inputs are described with informative prior distributions using a robust approach to development that incorporates all available lines of evidence for every parameter used as an input to the RA model. Calibration is performed using a classical nonlinear optimization routine, which is then used to initialize a Bayesian calibration. The Bayesian calibration constrains the uncertainty in the classical calibration, ultimately providing posterior distributions for all model parameters. The challenges of the calibration include high-dimensional parameter space, including spatially heterogeneous hydraulic conductivities, comparatively sparse data, and low RDX concentrations. Posterior parameter distributions developed in the calibration process are then used for stochastic predictive model runs into the future. The result of the forward runs is spatially and temporally explicit estimates of head and concentration with uncertainty at all points in space and time. The probabilistic modeling approach presented here includes innovative computational and statistical methods that leverage high-performance computing (HPC) resources. It makes use of prior modeling work performed at the chromium plume site in the central LANL area, with extensive updates. The risk assessment will ultimately be used to support decision-making at the site, using multiple appropriately weighted sources of information, as well as uncertainty, sensitivity, and value-of-information analyses. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗