Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PLATES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Experimental analysis of thermal performance of flat plate and evacuated tube solar collectors in stationary standard and daily conditions

New comparative tests on two different types of solar collectors are presented in this paper. A standard glazed flat plate collector and an evacuated tube collector are installed in parallel and tested at the same working conditions; the evacuated collector is a direct flow through type with external compound parabolic concentrator (CPC) reflectors. Efficiency in steady-state and quasi-dynamic conditions is measured following the standard and it is compared with the input/output curves measured for the whole day. The first purpose of the present work is the comparison of results in steady-state and quasi-dynamic test methods both for flat plate and evacuated tube collectors. Besides this, the objective is to characterize and to compare the daily energy performance of these two types of collectors. An effective mean for describing and analyzing the daily performance is the so called input/output diagram, in which the collected solar energy is plotted against the daily incident solar radiation. Test runs have been performed in several conditions to reproduce different conventional uses (hot water, space heating, solar cooling). Results are also presented in terms of daily efficiency versus daily average reduced temperature difference: this allows to represent the comparative characteristics of the two collectors when operating under variable conditions, especially with wide range of incidence angles. (author)

14 SOLAR ENERGY↗

High heat flux Langmuir probe array for the DIII-D divertor plates

Two modular arrays of Langmuir probes designed to handle a heat flux of up to 25 MW/m{sup 2} for 10 s exposures have been installed in the lower divertor target plates of the DIII-D tokamak. The 20 pyrolytic graphite probe tips have more than three times higher thermal conductivity and 16 times larger mass than the original DIII-D isotropic graphite probes. The probe tips have a fixed 12.5 deg. surface angle to distribute the heat flux more uniformly than the previous 6 mm diameter domed collectors and a symmetric 'rooftop' design to allow operation with reversed toroidal magnetic field. A large spring-loaded contact area improves heat conduction from each probe tip through a ceramic insulator into a cooled graphite divertor floor tile. The probe tips, brazed to molybdenum foil to ensure good electrical contact, are mounted in a ceramic tray for electrical isolation and reliable cable connections. The new probes are located 1.5 cm radially apart in a staggered arrangement near the entrance to the lower divertor pumping baffle and are linearly spaced 3 cm apart on the shelf above the in-vessel cryopump. Typical target plate profiles of J{sub sat}, T{sub e}, and V{sub f} with 4 mm spatial resolution are shown.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Radiation stability of CsBr:Eu needle image plates

Needle image plates (NIPs) based on CsBr:Eu are a good alternative to the BaFBr:Eu powder image plates due to their higher sensitivity and improved spatial resolution. The x-ray radiation stability of the NIPs produced by Agfa Gevaert was investigated and it was found that the radiation stability of the optimized NIPs is as high as that of the commercial CsI:Tl single crystals and much higher than reported in literature for the CsBr:Eu NIPs. The dependence of the sensitivity of the NIPs on the accumulated dose was determined for three different types of x-ray irradiation. It is shown that degradation of the sensitivity starts at about 10 Gy and it is the strongest for the most hard x-ray beam. If the energy absorbed by a NIP is taken into account, the degradation does not depend on the hardness of the applied x-ray beam. It is suggested that the main reason for the observed high radiation stability of the CsBr:Eu NIPs is the use of the oxygen-free Eu{sup 2+}-containing precursor CsEuBr{sub 3} for the doping in the manufacturing process.

36 MATERIALS SCIENCE↗

ULTRASONIC MEASUREMENT MODELS FOR SURFACE WAVE AND PLATE WAVE INSPECTIONS

A complete ultrasonic measurement model for surface and plate wave inspections is obtained, where all the electrical, electromechanical, and acoustic/elastic elements are explicitly described. Reciprocity principles are used to describe the acoustic/elastic elements specifically in terms of an integral of the incident and scattered wave fields over the surface of the flaw. As with the case of bulk waves, if one assumes the incident surface waves or plate waves are locally planar at the flaw surface, the overall measurement model reduces to a very modular form where the far-field scattering amplitude of the flaw appears explicitly.

36 MATERIALS SCIENCE↗

Damage Detection of CFRP Plates by Full-Spectral Analysis of a Fibre Bragg Grating Sensor Signal

This paper describes the measurement of average strain, strain distribution and vibration of cantilever beam made of Carbon Fiber Reinforced Plastics (CFRP), using a single Fibre Bragg Grating (FBG) sensor mounted on the beam surface. Average strain is determined from the displacement of the peak wavelength of reflected light from the FBG sensor. Unstrained reference FBG sensors were used to compensate for temperature drift and the photoelastic coefficient (P{sub e}), which was used to calculate the gauge factor. Measured strains agree with those measured by a resistance foil strain gauge attached to the sample. Stress distributions are measured by monitoring the variation in the full width half maximum (FWHM) values of the reflected spectrum, using a proposed optical analytical model, described in the paper. FWHM values were measured for both the cantilever test beam and a for a reference beam, loaded using a four-point bending rig. The trend of the stress distribution for the test beam matches with our analytical model, however with a relatively large noise present in the experimentally determined data. The vibration of cantilever beam was measured by temporal analysis of the peak reflection wavelength. This technique is very stable as measurements are not affected by variations in the signal amplitude. Finally an application of FBG sensors for damage detection of CFRP plates is demonstrated, by measuring the average strain and natural frequency. With small defects of different sizes applied to the CFRP plate, average strains were seen to increase with damage size and the natural frequency decreased with damage size.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Acoustic plate mode propagation and interaction with ultraviolet light in periodic AIN-on-sapphire structure

AlN overlay featuring periodic columnar structure fabricated by epitaxial lateral overgrowth technique leads to excitation of acoustic plate modes (APMs) not observed in overlays without such periodic structure. The measured velocities of acoustic plate modes propagating in AlN-on-sapphire structure were verified by numerical simulation. The APM velocity is strongly modulated by UV illumination at wavelengths from 240 to 365 nm, and the corresponding phase response is sensitive to both the UV power and the wavelength with maximum sensitivity of 3.0 ppm/({mu}W/cm{sup 2}) at 240 nm.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Optimum exposure conditions for computed radiography depending on fixed pattern noise and efficiency of imaging plate-scanner systems

The presently active standards on Computed Radiography (CR) need a major revision. It was observed by many users that the image quality for class B of EN 14784-2 is not achievable under the same exposure conditions as used for film exposure. A mathematical model was developed and tested, which allows the calculation of the image quality, proven by image quality indicators (IQI), depending on the fixed pattern noise and the efficiency of the used imaging plate (IP) scanner system. All tested IP scanner systems provide a fixed correlation between the measured signal/noise ratio (SNR) and the grey values in the digital images. The maximum achievable SNR{sub max} depends on the fixed pattern noise of the plate (high dose limit). Depending on the exposure dose an optimum visibility of IQIs can be predicted by calculation and measured considering the attenuation coefficient for calculation of the contrast/noise ratio (CNR). The diameter of the just visible wire is proportional to 1/sqrt(CNR). The optimum tube voltage for best visibility of IQIs and maximum CNR depend on the exposure dose. The optimum tube voltage for best visibility is achieved only at exposures with high dose. A dose dependant optimal tube voltage was not observed for film radiography.

07 ISOTOPE AND RADIATION SOURCES↗

Diagnosis of the ion density in two discharge modes generated in atmospheric pressure argon with pin-to-plate dielectric barrier geometry

In this study, the ion densities of an ac dielectric barrier discharge (DBD) (that is, a pin-to-plate DBD) as a function of the applied frequency in argon have been studied by means of the plasma radiation. The pin-to-plate DBD shows the characteristic of radiation oscillations with a low-frequency wave hidden in a high-frequency wave to form a mosaic structure, which reveals the coexistence of two discharge modes in the ac barrier discharge, i.e., the streamer mode and the corona mode. According to the oscillation frequencies, the ion densities are calculated. The results show that the ion density in streamer discharge is higher than that in corona discharge for about 1-2 magnitude orders.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Cerenkov and cyclotron Cerenkov instabilities in a dielectric loaded parallel plate waveguide sheet electron beam system

A dielectric loaded parallel plate waveguide sheet electron beam system can be taken as a reliable model for the practical dielectric loaded rectangular waveguide sheet beam system that has a transverse cross section with a large width to height ratio. By using kinetic theory, the dispersion equations for Cerenkov and cyclotron Cerenkov instabilities in the parallel plate waveguide sheet beam system have been obtained rigorously. The dependences of the growth rate of both instabilities on the electric and structural parameters have also been investigated in detail through numerical calculations. It is worthwhile to point out that adopting an electron beam with transverse velocity can evidently improve the growth rate of Cerenkov instability, which seems like the case of cyclotron Cerenkov instability.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Characterization of pulsed (plasma focus) neutron source with image plate and application to neutron radiography

Plasma focus device of Mather type developed in house has been used first time for neutron radiography of different objects. The device gives (1.2{+-}0.3) Multiplication-Sign 10{sup 9} neutrons per pulse produced by D-D fusion reaction with a pulse width of 50{+-}5 ns. The method involves exposing sample to be radiographed to thermalized D-D neutrons and recording the image on Fuji-film BAS-ND image plates. The thermal neutron component of the moderated beam was estimated using two image plates: a conventional IP for X-rays and gamma rays, and an IP doped with Gd for detecting neutrons.

07 ISOTOPE AND RADIATION SOURCES↗

Sphere-plate Casimir interaction in (D + 1)-dimensional spacetime

In this paper, we derive the formula for the Casimir interaction energy between a sphere and a plate in (D + 1)-dimensional Minkowski spacetime. It is assumed that the scalar field satisfies the Dirichlet or Neumann boundary conditions on the sphere and the plate. As in the D = 3 case, the formula is of TGTG type. One of our main contributions is deriving the translation matrices which express the change of bases between plane waves and spherical waves for general D. Using orthogonality of Gegenbauer polynomials, it turns out that the final TGTG formula for the Casimir interaction energy can be simplified to one that is similar to the D = 3 case. To illustrate the application of the formula, both large separation and small separation asymptotic behaviors of the Casimir interaction energy are computed. The large separation leading term is proportional to L{sup −D+1} if the sphere is imposed with Dirichlet boundary condition, and to L{sup −D−1} if the sphere is imposed with Neumann boundary condition, where L is distance from the center of the sphere to the plane. For the small separation asymptotic behavior, it is shown that the leading term is equal to the one obtained using proximity force approximation. The next-to-leading order term is also computed using perturbation method. It is shown that when the space dimension D is larger than 5, the next-to-leading order has sign opposite to the leading order term. Moreover, the ratio of the next-to-leading order term to the leading order term is linear in D, indicating a larger correction at higher dimensions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Broadband asymmetric acoustic transmission by a plate with quasi-periodic surface ridges

In this paper, an acoustic system with broadband asymmetric transmission is designed and fabricated, which consists of a water-immersed aluminum plate engraved with quasi-periodically-patterned ridges on single surface. It demonstrates that when the acoustic waves are launched into the system from the structured side, they can couple into the Lamb modes in the plate efficiently and attain a high transmission; on the contrary, when the waves are incident from the opposite flat side, the coupling is weak, and the transmission is low. Superior to systems with periodic patterning, this quasi-periodically-patterned system has a broad working frequency range due to the collective contributions from the multiple diffractions specific to the structure.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Image plate characterization and absolute calibration to low kilo-electron-volt electrons

We report on the characterization of an image plate and its absolute calibration to electrons in the low keV energy range (1–30 keV). In our case, an Agfa MD4.0 without protection layer was used in combination with a Fuji FLA7000 scanner. The calibration data are compared to other published data and a consistent picture of the sensitivity of image plates to electrons is obtained, which suggests a validity of the obtained calibration up to 100 keV.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Control design and robustness analysis of a ball and plate system by using polynomial chaos

In this paper, we present a mathematical model of a ball and plate system, a control law and analyze its robustness properties by using the polynomial chaos method. The ball rolls without slipping. There is an auxiliary robot vision system that determines the bodies' positions and velocities, and is used for control purposes. The actuators are to orthogonal DC motors, that changes the plate's angles with the ground. The model is a extension of the ball and beam system and is highly nonlinear. The system is decoupled in two independent equations for coordinates x and y. Finally, the resulting nonlinear closed loop systems are analyzed by the polynomial chaos methodology, which considers that some system parameters are random variables, and generates statistical data that can be used in the robustness analysis.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Near-field radiative heat transfer between two parallel SiO{sub 2} plates with and without microcavities

Near-to-far-field radiative heat transfer between two macroscopic SiO{sub 2} plates—with and without microcavities—was observed using a highly precise and accurate optical gap-measurement method. The experiments, conducted near 300 K, measured heat transfer as a function of gap separation from 1.0 μm to 50 μm and also as a function of temperature differences between 4.1 and 19.5 K. The gap-dependent heat flux was in excellent agreement with theoretical predictions. Furthermore, the effects of microcavities on the plate surfaces were clearly observed and significant enhancement of near-field radiative heat transfer was confirmed between gold-coated microcavities with narrow vacuum separation.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

High magnetic-refrigeration performance of plate-shaped La{sub 0.5}Pr{sub 0.5}Fe{sub 11.4}Si{sub 1.6} hydrides sintered in high-pressure H{sub 2} atmosphere

La(Fe, Si){sub 13} hydride is regarded as one of the most promising room-temperature refrigerants. However, to use the alloys in an active magnetic regenerator machine, it is vital to prepare thin refrigerants. In this work, a high H{sub 2} gas pressure of 50 MPa was employed to suppress the desorption of hydrogen atoms during the sintering process of plate-shaped La{sub 0.5}Pr{sub 0.5}Fe{sub 11.4}Si{sub 1.6} hydrides. At 330 K, a high-density sintered thin plate shows a large magnetic-entropy change ΔS{sub m} of 15.5 J/kg K (106 mJ/cm{sup 3 }K) for a field change of 2 T. The volumetric ΔS{sub m} is almost twice as large as that of bonded La(Fe,Si){sub 13} hydrides. Favorably, hysteresis is almost absent due to the existence of micropores with a porosity of 0.69% which has been analyzed with high-resolution X-ray microtomography.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Mo layer thickness requirement on the ion source back plate for the HNB and DNB ion sources in ITER

All the inner surfaces of the ion sources and the upstream surface of the plasma grid of the ITER neutral beam ion sources are proposed to be coated with molybdenum. This is done to avoid sputtering of the base material (Cu or CuCrZr) by the ions in the source plasma (D{sup +}, D{sub 2}{sup +}, D{sub 3}{sup +} or H{sup +}, H{sub 2}{sup +}, H{sub 3}{sup +}). The sputtering of Mo by the ions in the source plasma is low compared to that from Cu, and the threshold energy for sputtering ∼80 eV) is high compared to the energy of the ions in the source. However the D{sub 2}{sup +}, H{sub 2}{sup +} and D{sup +}, H{sup +} ions backstreaming from the accelerators will have energies that substantially exceed that threshold and it is important that the Mo layer is not eroded such that the base material is exposed to the source plasma. In the case of the HNB, the backstreaming ion power is calculated to be in the order of ∼1 MW, and the average energy of the backstreaming ions is calculated to be ∼300 keV. The ion sources in the HNB beam lines, 40 A 1 MeV D and 46 A 870 keV H beams, are supposed to operate for a period of 2 x 10{sup 7} s. For the DNB, 60 A 100 keV H beams, the corresponding number is 1.4 × 10{sup 6} s considering a beam duty cycle of 3s ON/20s OFF with 5 Hz modulation. The Mo layer on the ion source back plate should be thick enough to survive this operational time. Thickness estimation has been carried out taking into account the sputtering yields (atoms/ion), the energy spectrum of the backstreaming ions and the estimated profiles on the ion source back plate.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Spatial resolution of imaging plate with flash X-rays and its utilization for radiography

A flash X-ray source developed using pulsed electron accelerator with electron energy range of 400keV to 1030keV and a field emission cathode is characterized using X-ray imaging plates. Spatial resolution of the imaging system is measured using edge spread function fitted to data obtained from radiograph of Pb step wedge. A spatial resolution of 150±6 µm is obtained. The X-ray beam size is controlled by the anode-cathode configuration. Optimum source size of ∼13±2 mm diameter covering an area with intensity of ∼27000 PSL/mm{sup 2} is obtained on the imaging plate kept at a distance of ∼200 mm from the tip of the anode. It is used for recording radiographs of objects like satellite cable cutter, aero-engine turbine blade and variety of pyro-devices used in aerospace industry.

07 ISOTOPE AND RADIATION SOURCES↗