Study of the collector/heat pipe cooled externally configured thermionic diode

A collector/heat pipe cooled, externally configured (heated) thermionic diode module was designed for use in a laboratory test to demonstrate the applicability of this concept as the fuel element/converter module of an in-core thermionic electric power source. During the course of the program, this module evolved from a simple experimental mock-up into an advanced unit which was more reactor prototypical. Detailed analysis of all diode components led to their engineering design, fabrication, and assembly, with the exception of the collector/heat pipe. While several designs of high power annular wicked heat pipes were fabricated and tested, each exhibited unexpected performance difficulties. It was concluded that the basic cause of these problems was the formation of crud which interfered with the liquid flow in the annular passage of the evaporator region.

Source record↗

An electrohydrodynamic heat pipe.

A heat pipe of new design, using an electrode structure to orient and guide the dielectric liquid phase flow, is proposed. Analysis indicates that the operation of the electrohydrodynamic heat pipe is in direct analogy to capillary devices, with the polarization force acting in place of capillarity. Advantages of these new heat pipes include greatly reduced liquid friction, electrohydrodynamically enhanced evaporation and condensation heat transfer, and a possible voltage-controlled on/off feature. Preliminary calculations indicate that relatively high performance devices are possible.

Jones, T. B.↗

Electrohydrodynamic heat pipes.

An electrohydrodynamic heat pipe of radical design is proposed which substitutes polarization electrohydrodynamic force effects for capillarity in collecting, guiding, and pumping a condensate liquid phase. The discussed device is restricted to the use of dielectric liquids as working fluids. Because of the relatively poor thermal transport properties of these liquids, capillary heat pipes using these liquids have not been high performance devices. The employment of the electrohydrodynamic concept should enhance this performance and help fill the performance gap that exists in the temperature range from 250 F to 750 F for 'conventional' capillary heat pipes.

Jones, T. B.↗

Phenomena associated with bench and thermal-vacuum testing of super conductors - Heat pipes.

Test failures of heat pipes occur when the functional performance is unable to match the expected design limits or when the power applied to the heat pipe (in the form of heat) is distributed unevenly through the system, yielding a large thermal gradient. When a thermal gradient larger than expected is measured, it normally occurs in the evaporator or condenser sections of the pipe. Common causes include evaporator overheating, condenser dropout, noncondensable gas formation, surge and partial recovery of evaporator temperatures, masking of thermal profiles, and simple malfunctions due to leaks and mechanical failures or flaws. Examples of each of these phenomena are described along with corresponding failure analyses and corrective measures.

Marshburn, J. P.↗

Hydrogen evolution in nickel-water heat pipes.

A study was made of the evolution of hydrogen gas in nickel-water heat pipes for the purpose of investigating methods of accelerated life testing. The data were analyzed in terms of a phenomenological corrosion model of heat pipe degradation which incorporates corrosion and oxidation theory and contains parameters which can be determined by experiment. The gas was evolved with a linear time dependence and an exponential temperature dependence with an activation energy of 1.03 x 10 to the minus 19th joules. A flow-rate dependence of the gas evolution was found in the form of a threshold. The results were used to predict usable lifetimes of heat pipes operated at normal operating conditions from results taken under accelerated operating conditions.

Anderson, W. T.↗

Variable conductance heat pipe technology

Research and development programs in variable conductance heat pipe technology were conducted. The treatment has been comprehensive, involving theoretical and/or experimental studies in hydrostatics, hydrodynamics, heat transfer into and out of the pipe, fluid selection, and materials compatibility, in addition to the principal subject of variable conductance control techniques. Efforts were not limited to analytical work and laboratory experimentation, but extended to the development, fabrication and test of spacecraft hardware, culminating in the successful flight of the Ames Heat Pipe Experiment on the OAO-C spacecraft.

Marcus, B. D.↗

Variable Conductance Heat Pipe Technology

A research and development program in variable conductance heat pipe technology is reported. The project involved: (1) theoretical and/or experimental studies in hydrostatics, (2) hydrodynamics, (3) heat transfer into and out of the pipe, (4) fluid selection, and (5) materials compatibility. The development, fabrication, and test of the space hardware resulted in a successful flight of the heat pipe experiment on the OAO-3 satellite. A summary of the program is provided and a guide to the location of publications on the project is included.

Anderson, W. T.↗

Communications technology satellite - A variable conductance heat pipe application

A variable-conductance heat pipe system (VCHPS) has been designed to provide thermal control for a transmitter experiment package (TEP) to be flown on the Communications Technology Satellite. The VCHPS provides for heat rejection during TEP operation and minimizes the heat leak during power down operations. The VCHPS described features a unique method of aiding priming of arterial heat pipes and a novel approach to balancing heat pipe loads by staggering their control ranges.

Mock, P. R.↗

Heat pipes

The development and use of heat pipes are described, including space requirements and contributions. Controllable heat pipes, and designs for automatically maintaining a selected constant temperature, are discussed which would add to the versatility and usefulness of heat pipes in industrial processing, manufacture of integrated circuits, and in temperature stabilization of electronics.

Source record↗

Cryogenic heat pipe experiment - Flight performance onboard a sounding rocket

Flight data from a 15.8 mm OD, 760 mm long, axial-groove, methane cryogenic heat pipe verified successful priming and operation during six min of zero-g time. The nominal power applied to the evaporator was 60-w for the first 60 sec of zero-g time, 14 w for the next 270 sec, and 25 w for the last 20 sec of flight. The heat pipe condenser was mounted into an aluminum heat sink which was cooled to 103 K at launch and increased in temperature to 128 K by the end of the flight. Ground test data obtained for the flight heat pipe, together with theoretical predictions, indicate a zero-g heat transport capability of 3500 to 4000 w-cm in the 100-125 K temperature range.

Harwell, W.↗

Transverse header heat pipe

A novel variable-conductance heat-pipe approach has been developed that delivers high-capacity loads, while eliminating the problem of artery gas blockage present in conventional designs. The unit, known as a transverse header, uses ammonia as the working fluid and nitrogen as the control gas. Its overall cylindrical shape is 5.1 cm in diameter by 0.61 m long. Under test with a fluid heat source, the maximum load achieved as a VCHP was 3,600W. As with conventional gas-loaded pipes, good temperature control was also obtained. An application of this device as a VCHP header for a heat-pipe radiator is described.-

Edelstein, F.↗

Arterial gas occlusions in operating heat pipes

The effect of noncondensable gases on high performance arterial heat pipes has been investigated both analytically and experimentally. Models have been generated which characterize the dissolution of gases in condensate and the diffusional loss of dissolved gases from condensate in arterial flow. These processes, and others, have been used to postulate stability criteria for arterial heat pipes. Experimental observations of gas occlusions were made using a stainless steel heat pipe equipped with viewing ports, and the working fluids methanol and ammonia with the gas additives helium, argon, and xenon. Observations were related to gas transport models.

Saaski, E. W.↗

A 2.2 sq m /24 sq ft/ self-controlled deployable heat pipe radiator - Design and test

An all heat pipe, deployable radiator has been developed which can effectively control pumped fluid loop temperatures under varying loads using variable conductance panel heat pipes. The 2.2 sq m (24 sq ft) aluminum panel can be coupled to either a fluid header or a flexible heat pipe header capable of transporting 850 watts in a 90-deg bent configuration. Test results support the feasibility of using this system to passively control Freon-21 loop temperatures.

Edelstein, F.↗

Preliminary evaluation of a heat pipe heat exchanger on a regenerative turbofan

A preliminary evaluation was made of a regenerative turbofan engine using a heat pipe heat exchanger. The heat exchanger had an effectiveness of 0.70, a pressure drop of 3 percent on each side, and used sodium for the working fluid in the stainless steel heat pipes. The engine was compared to a reference turbofan engine originally designed for service in 1979. Both engines had a bypass ratio of 4.5 and a fan pressure ratio of 2.0. The design thrust of the engines was in the 4000 N range at a cruise condition of Mach 0.98 and 11.6 km. It is shown that heat pipe heat exchangers of this type cause a large weight and size problem for the engine. The penalties were too severe to be overcome by the small uninstalled fuel consumption advantage. The type of heat exchanger should only be considered for small airflow engines in flight applications. Ground applications might prove more suitable and flexible.

Kraft, G. A.↗

Application of axial grooves to cryogenic variable conductance heat pipe technology

Tests results obtained with an ATS axial groove aluminum extrusion adapted for use as a cryogenic thermal diode and/or a variable conductance heat pipe are presented. Ethane at a nominal operating temperature of 185 C was used as working fluid. In addition to both active and passive gas control, diode designs utilizing gas blockage or liquid trap were investigated. Specific requirements and performance parameters such as transient behavior, reservoir sizes, shutdown energy, etc., were evaluated. Results are also presented for tests where the liquid trap was used as a secondary heat pipe to demonstrate thermal switching with simultaneous heat pipe operation and diode shutdown.

Brennan, P. J.↗

Development and test of two flexible cryogenic heat pipes

Results are presented for a comprehensive test program directed toward determining the physical and thermal performance of two flexible cryogenic heat pipes that can provide a highly efficient thermal link between a detector and a space radiator or other cooling system in spacecraft applications. A 100-200 K high-power heat pipe is tested with methane at 100-140 K while a 15-100 K low-temperature pipe is designed for operation with nitrogen and oxygen and is optimized for oxygen in the range 75-90 K. Parametric performance and design tradeoff studies are carried out to determine the optimum geometry and materials for the container and wicking systems. A spiral multiwrap wick in conjunction with braided bellows appears to be a workable solution to the problem of developing highly flexible heat transport devices for cryogenic applications.

Wright, J. P.↗

Deployable heat-pipe radiator

Loop temperatures are controlled effectively under varying load conditions. Radiator has four separate pieces of hardware: heat-pipe panel, flexible heat-pipe leader, heat exchanger, fluid header. Single-fluid transport capacities of about 850 watts, corresponding to 51,000 watt-inches, have been achieved in 90 degree bend orientation of heat-pipe header.

Edelstein, F.↗