Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PH VALUE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Contamination of the transformer oil of power transformers and shunting reactors by metal-containing colloidal particles

The results of a measurement of the contamination of the oil in 66 transformers by metal-containing colloidal particles, formed as a result of the interaction of the oil with the structural materials (the copper of the windings, the iron of the tank and core etc.), and also the results of measurements of the optical turbidity of the oil in 136 transformers when they were examined at the Power Engineering Research and Development Center Company are presented. Methods of determining the concentration of copper and iron in transformer oil are considered. The limiting values of the optical turbidity factors, the copper and iron content are determined. These can serve as a basis for taking decisions on whether to replace the silica gel of the filters for continuously purifying the oil of power transformers and the shunting reactors in addition to the standardized oil contamination factors, namely, the dielectric loss tangent and the acidity number of the oil.

36 MATERIALS SCIENCE↗

Acidity of biomass fast pyrolysis bio-oils

The use of the TAN method for measuring the acidity of biomass fast pyrolysis bio-oil was evaluated. Suggestions for carrying out the analysis have been made. The TAN method by ASTM D664 or D3339 can be used for measuring the acidity of fast pyrolysis bio-oils and their hydrotreating products. The main difference between the methods is that ASTM D664 is specified for higher TAN values than ASTM D3339. Special focus should be placed on the interpretation of the TAN curves because they differ significantly from those of mineral oils. The curve for bio-oils is so gentle that the automatic detection may not observe the end point properly and derivatization should be used. The acidity of fast pyrolysis bio-oils is mainly derived (60-70%) from volatile acids. Other groups of compounds in fast pyrolysis bio-oils that influence acidity include phenolics, fatty and resin acids, and hydroxy acids.

09 BIOMASS FUELS↗

A Ta/W mixed addenda heteropolyacid with excellent acid catalytic activity and proton-conducting property

A new HPAs H{sub 20}[P{sub 8}W{sub 60}Ta{sub 12}(H{sub 2}O){sub 4}(OH){sub 8}O{sub 236}]·125H{sub 2}O (H-1) which comprises a Ta/W mixed addenda heteropolyanion, 20 protons, and 125 crystalline water molecules has been prepared through ion-exchange method. The structure and properties of H-1 have been explored in detail. AC impedance measurements indicate that H-1 is a good solid state proton conducting material at room temperature with a conductivity value of 7.2×10{sup −3} S cm{sup −1} (25 °C, 30% RH). Cyclic voltammograms of H-1 indicate the electrocatalytic activity towards the reduction of nitrite. Hammett acidity constant H{sub 0} of H-1 in CH{sub 3}CN is −2.91, which is the strongest among the present known HPAs. Relatively, H-1 exhibits excellent catalytic activities toward acetal reaction. - Highlights: • A Ta/W mixed addenda Heteropolyacid (H-1) was isolated. • Hammett acidity constant H{sub 0} of H-1 is the strongest among the present known HPAs. • H-1 exhibits excellent catalytic activities toward acetal reaction. • H-1 is a good solid state proton conducting material at room temperature.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Dissolution of cerium(IV)-lanthanide(III) oxides: Comparative effect of chemical composition, temperature, and acidity

The dissolution of Ce{sub 1-x}Ln{sub x}O{sub 2-x/2} solid solutions was undertaken in various acid media in order to evaluate the effects of several physicochemical parameters such as chemical composition, temperature, and acidity on the reaction kinetics. The normalized dissolution rates (R{sub L,0}) were found to be strongly modified by the trivalent lanthanide incorporation rate, due to the presence of oxygen vacancies decreasing the samples cohesion. Conversely, the nature of the trivalent cation considered only weakly impacted the R{sub L,0} values. The dependence of the normalized dissolution rates on the temperature then appeared to be of the same order of magnitude than that of chemical composition. Moreover, it allowed determining the corresponding activation energy (E{sub A} ≅ 60-85 kJ.mol{sup -1}) which accounts for a dissolution driven by surface-controlled reactions. A similar conclusion was made regarding the acidity of the solution: the partial order related to (H{sub 3}O{sup +}) reaching about 0.7. Finally, the prevailing effect of the incorporation of aliovalent cations in the fluorite-type CeO{sub 2} matrix on the dissolution kinetics precluded the observation of slight effects such as those linked to the complexing agents or to the crystal structure of the samples. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Corrosion Studies Of Raw And Treated Biomass-Derived Pyrolysis Oils

Rapid pyrolysis of biomass generates a liquid with properties that are particularly attractive for production of hydrocarbons that could be substituted for liquid fuels derived from petroleum. However, the high oxygen content of the biomass derived liquids presents a number of problems because of the high water content and the considerable concentration of carboxylic acids. Measurements of total acid number (TAN) of pyrolysis oil (bio-oil) samples show that values in the 90-100 range are fairly common. This level of acidity has been shown to cause corrosion problems that have to be addressed in the selection of structural materials that are used in the production, subsequent processing, storage and transport of the pyrolysis oils. Chemical analyses have been performed and laboratory corrosion studies have been conducted in order to assess the aggressiveness of the raw pyrolysis oil from several sources as well as the corrosion caused by a bio-oil that has been treated to reduce the acid and oxygen content. Components of biomass pyrolyzers have also been fabricated from various candidate alloys, and these components have been exposed for extended periods during operation of the pyrolyzers. This paper will report on results of these analyses and corrosion studies.

02 PETROLEUM↗

Toward Molecular Catalysts by Computer

Rational design of molecular catalysts requires a systematic approach to designing ligands with specific functionality and precisely tailored electronic and steric properties. It then becomes possible to devise computer protocols to predict accurately the required properties and ultimately to design catalysts by computer. In this account we first review how thermodynamic properties such as oxidation-reduction potentials (E0), acidities (pKa), and hydride donor abilities (ΔGH-) form the basis for a systematic design of molecular catalysts for reactions that are critical for a secure energy future (hydrogen evolution and oxidation, oxygen and nitrogen reduction, and carbon dioxide reduction). We highlight how density functional theory allows us to determine and predict these properties within “chemical” accuracy (~ 0.06 eV for redox potentials, ~ 1 pKa unit for pKa values, and ~ 1.5 kcal/mol for hydricities). These quantities determine free energy maps and profiles associated with catalytic cycles, i.e. the relative energies of intermediates, and help us distinguish between desirable and high-energy pathways and mechanisms. Good catalysts have flat profiles that avoid high activation barriers due to low and high energy intermediates. We illustrate how the criterion of a flat energy profile lends itself to the prediction of design points by computer for optimum catalysts. This research was carried out in the Center for Molecular Electro-catalysis, an Energy Frontier Research Center funded by the U.S. Department of Energy (DOE), Office of Science, Office of Basic Energy Sciences. Pacific Northwest National Laboratory (PNNL) is operated for the DOE by Battelle.

acidity↗

Acid-base properties of the Fe(CN){sub 6}{sup 3-}/Fe(CN){sub 6}{sup 4-} redox couple in the presence of various background mineral acids and salts

The acid-base behavior of Fe(CN){sub 6}{sup 4-} was investigated by measuring the formal potentials of the Fe(CN){sub 6}{sup 3-}/Fe(CN){sub 6}{sup 4-} couple over a wide range of acidic and neutral solution compositions. The experimental data were fitted to a model taking into account the protonated forms of Fe(CN){sub 6}{sup 4-} and using values of the activities of species in solution, calculated with a simple solution model and a series of binary data available in the literature. The fitting needed to take account of the protonated species HFe(CN){sub 6}{sup 3-} and H{sub 2}Fe(CN){sub 6}{sup 2-}, already described in the literature, but also the species H{sub 3}Fe(CN){sub 6}{sup -} (associated with the acid-base equilibrium H{sub 3}Fe(CN){sub 6}{sup -} ↔ H{sub 2}Fe(CN){sub 6}{sup 2-} + H{sup +}). The acidic dissociation constants of HFe(CN){sub 6}{sup 3-}, H{sub 2}Fe(CN){sub 6}{sup 2-} and H{sub 3}Fe(CN){sub 6}{sup -} were found to be pK(1)(II) = 3.9 ± 0.1, pK(2)(II) = 2.0 ± 0.1, and pK(3)(II) = 0.0 ± 0.1, respectively. These constants were determined by taking into account that the activities of the species are independent of the ionic strength. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Third Row Transition Metal Hexafluorides, Extraordinary Oxidizers, and Lewis Acids: Electron Affinities, Fluoride Affinities, and Heats of Formation of WF₆, ReF₆, OsF₆, IrF₆, PtF₆, and AuF₆

High level electronic structure calculations were used to evaluate reliable, self-consistent thermochemical data sets for the third row transitionmetal hexafluorides. The electron affinities, heats of formation, first (MF₆ → MF₅ + F) and average M-F bond dissociation energies, and fluoride affinities of MF₆ (MF₆ + F⁻→ MF₇ ⁻) and MF₅ (MF₅ + F⁻→ MF₆ ⁻) were calculated. The electron affinities which are a direct measure for the oxidizer strength increase monotonically from WF₆ to AuF₆, with PtF₆ and AuF₆ being extremely powerful oxidizers. The inclusion of spin orbit corrections is necessary to obtain the correct qualitative order for the electron affinities. The calculated electron affinities increase with increasing atomic number, are in good agreement with the available experimental values, and are as follows: WF₆ (3.15 eV), ReF₆ (4.58 eV), OsF₆ (5.92 eV), IrF₆ (5.99 eV), PtF₆ (7.09 eV), and AuF₆ (8.20 eV). A wide range of density functional theory exchange-correlation functionals were also evaluated, and only three gave satisfactory results. The corresponding pentafluorides are extremely strong Lewis acids, with OsF₅, IrF₅, PtF₅, and AuF₅ significantly exceeding the acidity of SbF₅. The optimized geometries of the corresponding MF₇⁻ anions for W through Ir are classical MF₇⁻ anions with M-F bonds; however, for PtF₇⁻ and AuF₇⁻ non-classical anions were found with a very weak external F-F bond between an MF₆⁻ fragment and a fluorine atom. These two anions are text book examples for “superhalogens” and can serve as F atom sources under very mild conditions, explaining the ability of PtF₆ to convert NF₃ to NF₄⁺, ClF₅ to ClF₆⁺, and Xe to XeF⁺ and why Bartlett failed to observe XePtF₆ as the reaction product of the PtF₆/Xe reaction.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

TH-A-207B-00: Shear-Wave Imaging and a QIBA US Biomarker Update

Imaging of tissue elastic properties is a relatively new and powerful approach to one of the oldest and most important diagnostic tools. Imaging of shear wave speed with ultrasound is has been added to most high-end ultrasound systems. Understanding this exciting imaging mode aiding its most effective use in medicine can be a rewarding effort for medical physicists and other medical imaging and treatment professionals. Assuring consistent, quantitative measurements across the many ultrasound systems in a typical imaging department will constitute a major step toward realizing the great potential of this technique and other quantitative imaging. This session will target these two goals with two presentations. A. Basics and Current Implementations of Ultrasound Imaging of Shear Wave Speed and Elasticity - Shigao Chen, Ph.D. Learning objectives-To understand: Introduction: Importance of tissue elasticity measurement Strain vs. shear wave elastography (SWE), beneficial features of SWE The link between shear wave speed and material properties, influence of viscosity Generation of shear waves External vibration (Fibroscan) ultrasound radiation force Point push Supersonic push (Aixplorer) Comb push (GE Logiq E9) Detection of shear waves Motion detection from pulse-echo ultrasound Importance of frame rate for shear wave imaging Plane wave imaging detection How to achieve high effective frame rate using line-by-line scanners Shear wave speed calculation Time to peak Random sample consensus (RANSAC) Cross correlation Sources of bias and variation in SWE Tissue viscosity Transducer compression or internal pressure of organ Reflection of shear waves at boundaries B. Elasticity Imaging System Biomarker Qualification and User Testing of Systems – Brian Garra, M.D. Learning objectives-To understand: Goals Review the need for quantitative medical imaging Provide examples of quantitative imaging biomarkers Acquaint the participant with the purpose of the RSNA Quantitative Imaging Biomarker Alliance and the need for such an organization Review the QIBA process for creating a quantitative biomarker Summarize steps needed to verify adherence of site, operators, and imaging systems to a QIBA profile Underlying Premise and Assumptions Objective, quantifiable results are needed to enhance the value of diagnostic imaging in clinical practice Reasons for quantification Evidence based medicine requires objective, not subjective observer data Computerized decision support tools (eg CAD) generally require quantitative input. Quantitative, reproducible measures are more easily used to develop personalized molecular medical diagnostic and treatment systems What is quantitative imaging? Definition from Imaging Metrology Workshop The Quantitative Imaging Biomarker Alliance Formation 2008 Mission Structure Example Imaging Biomarkers Being Explored Biomarker Selection Groundwork Draft Protocol for imaging and data evaluation QIBA Profile Drafting Equipment and Site Validation Technical Clinical Site and Equipment QA and Compliance Checking Ultrasound Elasticity Estimation Biomarker US Elasticity Estimation Background Current Status and Problems Biomarker Selection-process and outcome US SWS for Liver Fibrosis Biomarker Work Groundwork Literature search and analysis results Phase I phantom testing-Elastic phantoms Phase II phantom testing-Viscoelastic phantoms Digital Simulated Data Protocol and Profile Drafting Protocol: based on UPICT and existing literature and standards bodies protocols Profile-Current claims, Manufacturer specific appendices What comes after the profile Profile Validation Technical validation Clinical validation QA and Compliance Possible approaches Site Operator testing Site protocol re-evaluation Imaging system Manufacturer testing and attestation User acceptance testing and periodic QA Phantom Tests Digital Phantom Based Testing Standard QA Testing Remediation Schemes Profile Evolution Towards additional applications Towards higher accuracy and precision Supported in part by NIH contract HHSN268201300071C from NIBIB. Collaboration with GE Global Research, no personal support.; S. Chen, Some technologies described in this presentation have been licensed. Mayo Clinic and Dr. Chen have financial interests these technologies.

60 APPLIED LIFE SCIENCES↗

TH-A-207B-02: QIBA Ultrasound Elasticity Imaging System Biomarker Qualification and User Testing of Systems

Imaging of tissue elastic properties is a relatively new and powerful approach to one of the oldest and most important diagnostic tools. Imaging of shear wave speed with ultrasound is has been added to most high-end ultrasound systems. Understanding this exciting imaging mode aiding its most effective use in medicine can be a rewarding effort for medical physicists and other medical imaging and treatment professionals. Assuring consistent, quantitative measurements across the many ultrasound systems in a typical imaging department will constitute a major step toward realizing the great potential of this technique and other quantitative imaging. This session will target these two goals with two presentations. A. Basics and Current Implementations of Ultrasound Imaging of Shear Wave Speed and Elasticity - Shigao Chen, Ph.D. Learning objectives-To understand: Introduction: Importance of tissue elasticity measurement Strain vs. shear wave elastography (SWE), beneficial features of SWE The link between shear wave speed and material properties, influence of viscosity Generation of shear waves External vibration (Fibroscan) ultrasound radiation force Point push Supersonic push (Aixplorer) Comb push (GE Logiq E9) Detection of shear waves Motion detection from pulse-echo ultrasound Importance of frame rate for shear wave imaging Plane wave imaging detection How to achieve high effective frame rate using line-by-line scanners Shear wave speed calculation Time to peak Random sample consensus (RANSAC) Cross correlation Sources of bias and variation in SWE Tissue viscosity Transducer compression or internal pressure of organ Reflection of shear waves at boundaries B. Elasticity Imaging System Biomarker Qualification and User Testing of Systems – Brian Garra, M.D. Learning objectives-To understand: Goals Review the need for quantitative medical imaging Provide examples of quantitative imaging biomarkers Acquaint the participant with the purpose of the RSNA Quantitative Imaging Biomarker Alliance and the need for such an organization Review the QIBA process for creating a quantitative biomarker Summarize steps needed to verify adherence of site, operators, and imaging systems to a QIBA profile Underlying Premise and Assumptions Objective, quantifiable results are needed to enhance the value of diagnostic imaging in clinical practice Reasons for quantification Evidence based medicine requires objective, not subjective observer data Computerized decision support tools (eg CAD) generally require quantitative input. Quantitative, reproducible measures are more easily used to develop personalized molecular medical diagnostic and treatment systems What is quantitative imaging? Definition from Imaging Metrology Workshop The Quantitative Imaging Biomarker Alliance Formation 2008 Mission Structure Example Imaging Biomarkers Being Explored Biomarker Selection Groundwork Draft Protocol for imaging and data evaluation QIBA Profile Drafting Equipment and Site Validation Technical Clinical Site and Equipment QA and Compliance Checking Ultrasound Elasticity Estimation Biomarker US Elasticity Estimation Background Current Status and Problems Biomarker Selection-process and outcome US SWS for Liver Fibrosis Biomarker Work Groundwork Literature search and analysis results Phase I phantom testing-Elastic phantoms Phase II phantom testing-Viscoelastic phantoms Digital Simulated Data Protocol and Profile Drafting Protocol: based on UPICT and existing literature and standards bodies protocols Profile-Current claims, Manufacturer specific appendices What comes after the profile Profile Validation Technical validation Clinical validation QA and Compliance Possible approaches Site Operator testing Site protocol re-evaluation Imaging system Manufacturer testing and attestation User acceptance testing and periodic QA Phantom Tests Digital Phantom Based Testing Standard QA Testing Remediation Schemes Profile Evolution Towards additional applications Towards higher accuracy and precision Supported in part by NIH contract HHSN268201300071C from NIBIB. Collaboration with GE Global Research, no personal support.; S. Chen, Some technologies described in this presentation have been licensed. Mayo Clinic and Dr. Chen have financial interests these technologies.

60 APPLIED LIFE SCIENCES↗

TH-A-207B-01: Basics and Current Implementations of Ultrasound Imaging of Shear Wave Speed and Elasticity

Imaging of tissue elastic properties is a relatively new and powerful approach to one of the oldest and most important diagnostic tools. Imaging of shear wave speed with ultrasound is has been added to most high-end ultrasound systems. Understanding this exciting imaging mode aiding its most effective use in medicine can be a rewarding effort for medical physicists and other medical imaging and treatment professionals. Assuring consistent, quantitative measurements across the many ultrasound systems in a typical imaging department will constitute a major step toward realizing the great potential of this technique and other quantitative imaging. This session will target these two goals with two presentations. A. Basics and Current Implementations of Ultrasound Imaging of Shear Wave Speed and Elasticity - Shigao Chen, Ph.D. Learning objectives-To understand: Introduction: Importance of tissue elasticity measurement Strain vs. shear wave elastography (SWE), beneficial features of SWE The link between shear wave speed and material properties, influence of viscosity Generation of shear waves External vibration (Fibroscan) ultrasound radiation force Point push Supersonic push (Aixplorer) Comb push (GE Logiq E9) Detection of shear waves Motion detection from pulse-echo ultrasound Importance of frame rate for shear wave imaging Plane wave imaging detection How to achieve high effective frame rate using line-by-line scanners Shear wave speed calculation Time to peak Random sample consensus (RANSAC) Cross correlation Sources of bias and variation in SWE Tissue viscosity Transducer compression or internal pressure of organ Reflection of shear waves at boundaries B. Elasticity Imaging System Biomarker Qualification and User Testing of Systems – Brian Garra, M.D. Learning objectives-To understand: Goals Review the need for quantitative medical imaging Provide examples of quantitative imaging biomarkers Acquaint the participant with the purpose of the RSNA Quantitative Imaging Biomarker Alliance and the need for such an organization Review the QIBA process for creating a quantitative biomarker Summarize steps needed to verify adherence of site, operators, and imaging systems to a QIBA profile Underlying Premise and Assumptions Objective, quantifiable results are needed to enhance the value of diagnostic imaging in clinical practice Reasons for quantification Evidence based medicine requires objective, not subjective observer data Computerized decision support tools (eg CAD) generally require quantitative input. Quantitative, reproducible measures are more easily used to develop personalized molecular medical diagnostic and treatment systems What is quantitative imaging? Definition from Imaging Metrology Workshop The Quantitative Imaging Biomarker Alliance Formation 2008 Mission Structure Example Imaging Biomarkers Being Explored Biomarker Selection Groundwork Draft Protocol for imaging and data evaluation QIBA Profile Drafting Equipment and Site Validation Technical Clinical Site and Equipment QA and Compliance Checking Ultrasound Elasticity Estimation Biomarker US Elasticity Estimation Background Current Status and Problems Biomarker Selection-process and outcome US SWS for Liver Fibrosis Biomarker Work Groundwork Literature search and analysis results Phase I phantom testing-Elastic phantoms Phase II phantom testing-Viscoelastic phantoms Digital Simulated Data Protocol and Profile Drafting Protocol: based on UPICT and existing literature and standards bodies protocols Profile-Current claims, Manufacturer specific appendices What comes after the profile Profile Validation Technical validation Clinical validation QA and Compliance Possible approaches Site Operator testing Site protocol re-evaluation Imaging system Manufacturer testing and attestation User acceptance testing and periodic QA Phantom Tests Digital Phantom Based Testing Standard QA Testing Remediation Schemes Profile Evolution Towards additional applications Towards higher accuracy and precision Supported in part by NIH contract HHSN268201300071C from NIBIB. Collaboration with GE Global Research, no personal support.; S. Chen, Some technologies described in this presentation have been licensed. Mayo Clinic and Dr. Chen have financial interests these technologies.

60 APPLIED LIFE SCIENCES↗

Molecular Structures, Acid-Base Properties, and Formation of Group 6 Transition Metal Hydroxides

Density functional theory (DFT) and coupled cluster theory (CCSD(T)) were used to study the group 6 metal (M = Cr, Mo, W) hydroxides: MO3-m(OH)2m (m = 1-3), M2O6-m(OH)2m (m = 1-5), M3O9-m(OH)2m (m = 1, 2), and M4O11(OH)2. The calculations were done up to the complete basis set (CBS) limit for the CCSD(T) method. Molecular structures of many low-energy conformers/isomers were located. Brønsted acidities in the gas phase and pKa values in aqueous solution were predicted for MO3-m(OH)2m (m = 1-3) and MnO3n-1(OH)2 (n = 2-4). In addition, Brønsted basicities and Lewis acidities (fluoride affinities) were predicted for MO3-m(OH)2m (m = 1-3) as well as the metal oxide clusters MnO3n (n = 1-3). The metal hydroxides were predicted to be strong Brønsted acids and weak to modest Brønsted bases and Lewis acids. The pKa values can have values as negative as -31. Potential energy surfaces for the hydrolysis of the MnO3n (n = 1-4) clusters were calculated. Heats of formation of the metal hydroxides were predicted from the calculated reaction energies, and the agreement with the limited available experimental data is good. The first hydrolysis step leading to the formation of MnO3n-1(OH)2 was predicted to be exothermic, with the exothermicity becoming less negative as n increases and essentially converged at n = 3. Reaction rate constants for the hydrogen transfer steps were calculated using transition state theory and RRKM theory. Further hydrolysis of MnO3n-1(OH)2 tends to be endothermic especially for M = Cr. Fifty-five DFT exchange-correlation functionals were benchmarked for the calculations of the reaction energies, complexation energies, and reaction barriers by comparing to our CCSD(T) results. Overall, the DFT results for the potential energy surfaces are semiquantitatively correct, but no single functional works for all processes and all three metals. Among the functionals benchmarked, the wB97, wB97X, B1B95, B97-1, mPW1LYP, and X3LYP functionals have the best performance. Linear correlations between the calculated reaction barrier and reaction energy for hydrogen transfer reactions to the terminal =O atom and to the bridge O atom were found to be quite different, indicating their different reaction properties. The calculated Lewis acidity (fluoride affinity) was found to best correlate with the calculated adsorption energy, the dissociative adsorption energy, and the reaction barrier for hydrogen transfer reactions to the terminal =O atom.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

WE-G-213-01: Roentgen and the Birth of Modern Medical Physics

Roentgen and the Birth of Modern Medical Physics – Perry Sprawls Wilhelm Roentgen is well known for his discovery of x-radiation. What is less known and appreciated is his intensive research following the discovery to determine the characteristics of the “new kind of radiation” and demonstrate its great value for medical purposes. In this presentation we will imagine ourselves in Roentgen’s mind and follow his thinking, including questions and doubts, as he designs and conducts a series of innovative experiments that provided the foundation for the rapid growth of medical physics. Learning Objectives: Become familiar with the personal characteristics and work of Prof. Roentgen that establishes him as an inspiring model for the medical physics profession. Observe the thought process and experiments that determined and demonstrated the comprehensive characteristics of x-radiation. The AAPM Award Eponyms: William D. Coolidge, Edith H. Quimby, and Marvin M.D. Williams - Who were they and what did they do? – Lawrence N. Rothenberg William David Coolidge (1873–1975) William Coolidge was born in Hudson, NY in 1873. He obtained his BS at the Massacusetts Institute of Technology in 1896. Coolidge then went to the University of Leipzig, Germany for graduate study with physicists Paul Drude and Gustave Wiedemann and received a Ph.D. in 1899. While in Germany he met Wilhelm Roentgen. Coolidge returned to the US to teach at MIT where he was associated with Arthur A. Noyes of the Chemistry Department, working on the electrical conductivity of aqueous solutions. Willis R. Whitney, under whom Coolidge had worked before going to Germany, became head of the newly formed General Electric Research Laboratory and he invited Coolidge to work with him. In 1905, Coolidge joined the staff of the GE laboratory and was associated with it for the remainder of his life. He developed ductile tungsten filaments to replace fragile carbon filaments as the material for electric light bulb filaments. Until that innovation light bulbs had a notoriously short life. He later incorporated the ductile tungsten as a filament material for a hot cathode, fully evacuated x-ray tube, first described in 1912, which allowed higher current and x-ray output, and greater reliability than had previously been possible. These “Coolidge x-ray tubes” were far superior to the cold cathode, partial pressure gas x-ray tubes that had been in use since Roentgen’s discovery of x-rays in 1895. The Coolidge tube with incremental developments is now the key component for x-ray production in all of our modern x-ray imaging devices, such as CT scanners, interventional radiology systems, and mammography units. Coolidge was also involved in the development of sectional x-ray tubes for research and treatment that were initially designed to reach 800 kV. Additional improvements led to 1 MV and 2 MV devices. In 1932 Coolidge became director of the General Electric Research Laboratory, and in 1940, was made Vice-President and Director of Research. In 1945 he retired and was named Director Emeritus of the laboratory. Coolidge held 83 patents and was recognized for these and many other achievements by election to the National Academy of Engineers, a place in the Engineering Hall of Fame and the National Inventor’s Hall of Fame. The AAPM’s highest honor, the Coolidge Award, was named after him. He accepted Honorary Membership in the AAPM and was the first recipient of the AAPM Coolidge Award, which was presented to him in a special ceremony in Schenectady, NY in 1972 when he was 100 years old. Edith Hinckley Quimby (1891–1982) Edith Quimby was born in Rockford, IL in 1891. She graduated from Whitman College in Walla Walla, WA with a B.S. in 1913, and then obtained a masters degree from the University of California at Berkeley. Later in her career, after many significant achievements, Quimby was awarded honorary doctorates by Whitman College and Rutgers University. Edith Quimby was hired by Giacchino Failla as a radiation physicist at Memorial Hospital for Cancer in New York City. Failla had studied with Madame Curie and obtained his doctoral degree in her laboratory. After many groundbreaking medical physics studies from 1919 until 1942, they both moved to Columbia University. Dr. Quimby developed a widely employed dosimetry system for single plane implants with radium and radon seeds, and a dosimetry methodology for internal radionuclides. She was author of more than 75 scientific publications, and of significant textbooks including the first comprehensive physics textbook for radiologists “Physical Foundations of Radiology”, which was co-authored with Otto Glasser, Lauriston Taylor and James Weatherwax in the first edition, with Russell Morgan added for the second edition and Paul Goodwin for the fourth edition. With Sergei Feitelberg, M.D. she published two editions of “Radioactive Isotopes in Medicine and Biology: Basic Physics and Instrumentation”. Quimby became a renowned examiner for the American Board of Radiology when the third ABR examination, given in 1936, added physics. She served as President of the American Radium Society, received the RSNA Gold Medal, and also numerous prestigious awards given to women in science. Edith Quimby was a Charter Member of AAPM. The AAPM Lifetime Achievement Award was renamed the Edith H. Quimby Lifetime Achievement Award in her honor in 2011. Marvin Martin Dixon Williams (1902–1981) Marvin Williams was born in Walla Walla, WA in 1902, and attended the same college as Edith Quimby, graduating from Whitman College in 1926. He was greatly influenced to go into medical physics by her accomplishments. During his early career, Williams worked with James Weatherwax in Philadelphia while he was working toward an M.S. from the University of Pennsylvania. In 1931 Williams was awarded a Ph.D. in Biophysics from the University of Minnesota, with the work actually performed at the Mayo Clinic Graduate School of the University. While completing his Ph.D. studies, Marvin met Dr. Paul Hodges who had returned from the Peiping Union Medical College in Peiping (now Beijing), China. Hodges suggested that a physicist be sent to Peiping to install x-ray therapy equipment and a radon plant. Williams accepted the position and, in 1931, he and his wife Orpha left for China. Before going to China, Williams had spent time with the physics group at Memorial Hospital to learn about the operation of a radon plant. In China, he constructed the radon plant, employing 0.25 g of radium, and also installed the x-ray therapy unit. Williams and his wife returned to the US in 1935, and he accepted a research position at the Mayo Clinic. In 1950, he became Professor of Biophysics at Mayo, where he taught physics and biophysics until his retirement in 1967. Williams was also very active in the American Board of Radiology where, from 1944 through 1977, he examined over 3000 radiologists and 250 physicists. Marvin Williams was a Charter member of AAPM, served as the fourth President of AAPM in 1963, and was the fourth recipient the AAPM Coolidge Award in 1975. The Marvin Williams Award was originally established as the highest award of the American College of Medical Physics. When various functions of the ACMP were absorbed into the AAPM in 2012, the Marvin M D Williams Professional Achievement Award became one of the AAPM’s highest honors. Learning Objectives: Become familiar with the persons in whose honor the three major AAPM Award are named Learn about the achievements and activities which influenced the AAPM to name these awards in their honor.

60 APPLIED LIFE SCIENCES↗

WE-G-213-02: The AAPM Award Eponyms: William D. Coolidge, Edith H. Quimby, and Marvin M.D. Williams - Who Were They and What Did They Do?

Roentgen and the Birth of Modern Medical Physics – Perry Sprawls Wilhelm Roentgen is well known for his discovery of x-radiation. What is less known and appreciated is his intensive research following the discovery to determine the characteristics of the “new kind of radiation” and demonstrate its great value for medical purposes. In this presentation we will imagine ourselves in Roentgen’s mind and follow his thinking, including questions and doubts, as he designs and conducts a series of innovative experiments that provided the foundation for the rapid growth of medical physics. Learning Objectives: Become familiar with the personal characteristics and work of Prof. Roentgen that establishes him as an inspiring model for the medical physics profession. Observe the thought process and experiments that determined and demonstrated the comprehensive characteristics of x-radiation. The AAPM Award Eponyms: William D. Coolidge, Edith H. Quimby, and Marvin M.D. Williams - Who were they and what did they do? – Lawrence N. Rothenberg William David Coolidge (1873–1975) William Coolidge was born in Hudson, NY in 1873. He obtained his BS at the Massacusetts Institute of Technology in 1896. Coolidge then went to the University of Leipzig, Germany for graduate study with physicists Paul Drude and Gustave Wiedemann and received a Ph.D. in 1899. While in Germany he met Wilhelm Roentgen. Coolidge returned to the US to teach at MIT where he was associated with Arthur A. Noyes of the Chemistry Department, working on the electrical conductivity of aqueous solutions. Willis R. Whitney, under whom Coolidge had worked before going to Germany, became head of the newly formed General Electric Research Laboratory and he invited Coolidge to work with him. In 1905, Coolidge joined the staff of the GE laboratory and was associated with it for the remainder of his life. He developed ductile tungsten filaments to replace fragile carbon filaments as the material for electric light bulb filaments. Until that innovation light bulbs had a notoriously short life. He later incorporated the ductile tungsten as a filament material for a hot cathode, fully evacuated x-ray tube, first described in 1912, which allowed higher current and x-ray output, and greater reliability than had previously been possible. These “Coolidge x-ray tubes” were far superior to the cold cathode, partial pressure gas x-ray tubes that had been in use since Roentgen’s discovery of x-rays in 1895. The Coolidge tube with incremental developments is now the key component for x-ray production in all of our modern x-ray imaging devices, such as CT scanners, interventional radiology systems, and mammography units. Coolidge was also involved in the development of sectional x-ray tubes for research and treatment that were initially designed to reach 800 kV. Additional improvements led to 1 MV and 2 MV devices. In 1932 Coolidge became director of the General Electric Research Laboratory, and in 1940, was made Vice-President and Director of Research. In 1945 he retired and was named Director Emeritus of the laboratory. Coolidge held 83 patents and was recognized for these and many other achievements by election to the National Academy of Engineers, a place in the Engineering Hall of Fame and the National Inventor’s Hall of Fame. The AAPM’s highest honor, the Coolidge Award, was named after him. He accepted Honorary Membership in the AAPM and was the first recipient of the AAPM Coolidge Award, which was presented to him in a special ceremony in Schenectady, NY in 1972 when he was 100 years old. Edith Hinckley Quimby (1891–1982) Edith Quimby was born in Rockford, IL in 1891. She graduated from Whitman College in Walla Walla, WA with a B.S. in 1913, and then obtained a masters degree from the University of California at Berkeley. Later in her career, after many significant achievements, Quimby was awarded honorary doctorates by Whitman College and Rutgers University. Edith Quimby was hired by Giacchino Failla as a radiation physicist at Memorial Hospital for Cancer in New York City. Failla had studied with Madame Curie and obtained his doctoral degree in her laboratory. After many groundbreaking medical physics studies from 1919 until 1942, they both moved to Columbia University. Dr. Quimby developed a widely employed dosimetry system for single plane implants with radium and radon seeds, and a dosimetry methodology for internal radionuclides. She was author of more than 75 scientific publications, and of significant textbooks including the first comprehensive physics textbook for radiologists “Physical Foundations of Radiology”, which was co-authored with Otto Glasser, Lauriston Taylor and James Weatherwax in the first edition, with Russell Morgan added for the second edition and Paul Goodwin for the fourth edition. With Sergei Feitelberg, M.D. she published two editions of “Radioactive Isotopes in Medicine and Biology: Basic Physics and Instrumentation”. Quimby became a renowned examiner for the American Board of Radiology when the third ABR examination, given in 1936, added physics. She served as President of the American Radium Society, received the RSNA Gold Medal, and also numerous prestigious awards given to women in science. Edith Quimby was a Charter Member of AAPM. The AAPM Lifetime Achievement Award was renamed the Edith H. Quimby Lifetime Achievement Award in her honor in 2011. Marvin Martin Dixon Williams (1902–1981) Marvin Williams was born in Walla Walla, WA in 1902, and attended the same college as Edith Quimby, graduating from Whitman College in 1926. He was greatly influenced to go into medical physics by her accomplishments. During his early career, Williams worked with James Weatherwax in Philadelphia while he was working toward an M.S. from the University of Pennsylvania. In 1931 Williams was awarded a Ph.D. in Biophysics from the University of Minnesota, with the work actually performed at the Mayo Clinic Graduate School of the University. While completing his Ph.D. studies, Marvin met Dr. Paul Hodges who had returned from the Peiping Union Medical College in Peiping (now Beijing), China. Hodges suggested that a physicist be sent to Peiping to install x-ray therapy equipment and a radon plant. Williams accepted the position and, in 1931, he and his wife Orpha left for China. Before going to China, Williams had spent time with the physics group at Memorial Hospital to learn about the operation of a radon plant. In China, he constructed the radon plant, employing 0.25 g of radium, and also installed the x-ray therapy unit. Williams and his wife returned to the US in 1935, and he accepted a research position at the Mayo Clinic. In 1950, he became Professor of Biophysics at Mayo, where he taught physics and biophysics until his retirement in 1967. Williams was also very active in the American Board of Radiology where, from 1944 through 1977, he examined over 3000 radiologists and 250 physicists. Marvin Williams was a Charter member of AAPM, served as the fourth President of AAPM in 1963, and was the fourth recipient the AAPM Coolidge Award in 1975. The Marvin Williams Award was originally established as the highest award of the American College of Medical Physics. When various functions of the ACMP were absorbed into the AAPM in 2012, the Marvin M D Williams Professional Achievement Award became one of the AAPM’s highest honors. Learning Objectives: Become familiar with the persons in whose honor the three major AAPM Award are named Learn about the achievements and activities which influenced the AAPM to name these awards in their honor.

60 APPLIED LIFE SCIENCES↗

A Voltammetric Sensor Based on MgFe2O4 Decorated on Reduced Graphene Oxide-modified Electrode for Sensitive and Simultaneous Determination of Catechol and Hydroquinone

In this work facile one step synthesis of magnesium ferrite (MgFe2O4) nanoparticles decorated on reduced graphene oxide (MgFe@RGO) using a microwave assisted hydrothermal procedure is reported. The synthesized material was characterized with help of several techniques and applied for the modification of glassy carbon electrode. Such prepared electrode was utilized for successive simultaneous detection of structurally similar compounds, 1,2- and 1,4-dihydroxibenzenes (catechol (CC) and hydroquinone (HQ)), using differential pulse voltammetry technique. It was found that oxidation current increases linearly with the concentrations of both investigated compounds. Detection limits for both species are ≤0.31 μM. The best analytical response in the presence of both CC and HQ, taking into account peak shape and peak current, was obtained at pH 5.6 utilizing acetate buffer solution. The often-presented species in the surface waters as well as gallic acid and caffeine do not interfere with determination of CC and HQ, while ascorbic acid shows high interference. The method is successfully applied for detection of catechol and hydroquinone in real samples analyses. © 2018 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Covalent Triazine-Based Frameworks with Ru-tda Based Catalyst Anchored via Coordination Bond for Photoinduced Water Oxidation

Light-induced water splitting (hν-WS) for the production of hydrogen as a solar fuel is considered a promising sustainable strategy for the replacement of fossil fuels. An efficient system for hν-WS involves a photoactive material that, upon shining light, is capable of separating and transferring charges to catalysts for the hydrogen and oxygen evolution processes. Covalent triazine-based frameworks (CTFs) represent an interesting class of 2D organic light-absorbing materials that have recently emerged thanks to their tunable structural, optical and morphological properties. Typically, catalysts (Cat) are metallic nanoparticles generated in situ after photoelectroreduction of metal precursors or directly drop-casted on top of the CTF material to generate Cat-CTF assemblies. Here, in this work, the synthesis, characterization and photocatalytic performance of a novel hybrid material, Ru-CTF, is reported, based on a CTF structure featuring dangling pyridyl groups that allow the Ru-tda (tda is [2,2':6',2'“-terpyridine]-6,6'”-dicarboxylic acid) water oxidation catalyst (WOC) unit to coordinate via covalent bond. The Ru-CTF molecular hybrid material can carry out the light-induced water oxidation reaction efficiently at neutral pH, reaching values of maximum TOF of 17 h -1 and TONs in the range of 220 using sodium persulfate as a sacrificial electron acceptor.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The Effect of Environmental Factors on Total Arsenic Accumulation in Sarcodia suiae, Rhodophyta

Little is known about the effects of environmental factors on total arsenic (TAs) accumulation in marine Rhodophyta. The effects of five environmental factors (temperature, light intensity, pH, exposure duration, and phosphate) at various As(III) concentrations were investigated in Sarcodia suiae. The highest TAs accumulations were recorded at 25°C, a luminance of 80 µmol photons m{sup −2} s{sup −1}, and a pH of 8. TAs uptake increased significantly over time. However, a higher phosphate concentration reduced TAs accumulation. These data show that the extent of TAs accumulation depends on various environmental factors. Hence, our results suggest a potential in arsenic recovery process in wastewater treatments. S. suiae may provide a new means of reducing levels of arsenic in contaminated water and may be used as a potential Rhodophyta model for investigating other types of heavy metal pollution in future.

54 ENVIRONMENTAL SCIENCES↗