Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Optical Micrometer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Temperature-Controlled Reversible Formation and Phase Transformation of 3D Nanocrystal Superlattices Through In Situ Small-Angle X-ray Scattering

For decades, the spontaneous organization of nanocrystals into superlattices has captivated the scientific community. However, achieving direct control over the formation of the superlattice and its phase transformations has proven to be a grand challenge, often resulting in the generation of multiple symmetries under the same experimental conditions. Here, we achieve direct control over the formation of the superlattice and its phase transformations by modulating the thermal energy of a nanocrystal dispersion without relying on solvent evaporation. In this study, we follow the temperature-dependent dynamics of the self-assembly process using synchrotron-based small-angle X-ray scattering. When cooled below –24.5 °C, lead sulfide nanocrystals form micrometer-sized three-dimensional phase-pure body-centered cubic superlattices. When cooled below –35.1 °C, these superlattices undergo a collective diffusionless phase transformation that yields denser body-centered tetragonal phases. These structural changes can be reversed by increasing the temperature of the dispersion and may lead to the direct modulation of the optical properties of these artificial solids.

36 MATERIALS SCIENCE↗

Unusual electronic transport in (1 - x )Cu 2 Se-( x )CuInSe 2 hierarchical composites

The ability to control the relative density of electronic point defects as well as their energy distribution in semiconductors could afford a systematic modulation of their electronic, optical, and optoelectronic properties. Using a model binary hybrid system Cu 2 Se–CuInSe 2 , we have investigated the correlation between phase composition, microstructure, and electronic transport behavior in the synthesized composites. We found that both Cu 2 Se and CuInSe 2 phases coexist at multiple length scales, ranging from sub-ten nanometer to several micrometers, leading to the formation of a hybrid hierarchical microstructure. Astonishingly, the electronic phase diagram of the (1 - x)Cu 2 Se–(x)CuInSe 2 (15% ≤ x ≤ 100%) hierarchical composites remarkably deviates from the trend normally expected for composites between a heavily doped semiconductor (Cu 2 Se) and a poorly conducting phase (CuInSe 2 ). A sudden 3-fold increase in the electrical conductivity and carrier concentration along with a marginal increase in the carrier mobility is observed for composites at the vicinity of equimolar composition (48% ≤ x ≤ 52%). The carrier concentration increases from ~1.5 × 10 20 cm -3 for the composites with x ≤ 45% to 5.0 × 10 20 cm -3 for x = 50%, and remains constant at 4.5 × 10 20 cm -3 with x value in the range of 52% < x ≤ 90%, then quickly drops to 8 × 10 18 cm -3 for pristine CuInSe 2 phase (x = 100%). The atypical electronic behavior was rationalized in the light of the formation of an inter-band (IB) within the band gap, which arises from the hybridization of native electronic point defects from both Cu 2 Se and CuInSe 2 phases in the resulting hierarchical composites. The result points to a new strategy to modulate the electronic structure of semiconductor composites to maximize interaction and coupling between two fundamentally contrasting properties enabling access to electronic hybrid systems with potential applications as interactive and stimuli-responsive multifunctional materials.

36 MATERIALS SCIENCE↗

Sub-micrometer resolution proximity X-ray microscope with digital image registration

A compact laboratory proximity soft X-ray microscope providing submicrometer spatial resolution and digital image registration is described. The microscope consists of a laser-plasma soft X-ray radiation source, a Schwarzschild objective to illuminate the test sample, and a two-coordinate detector for image registration. Radiation, which passes through the sample under study, generates an absorption image on the front surface of the detector. Optical ceramic YAG:Ce was used to convert the X-rays into visible light. An image was transferred from the scintillator to a charge-coupled device camera with a Mitutoyo Plan Apo series lens. The detector’s design allows the use of lenses with numerical apertures of NA = 0.14, 0.28, and 0.55 without changing the dimensions and arrangement of the elements of the device. This design allows one to change the magnification, spatial resolution, and field of view of the X-ray microscope. A spatial resolution better than 0.7 μm and an energy conversion efficiency of the X-ray radiation with a wavelength of 13.5 nm into visible light collected by the detector of 7.2% were achieved with the largest aperture lens.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spectral reflectance of selected aqueous solutions for water quality applications

The relative specular reflectances of individual aqueous solutions having a particular chemical salt content were measured in the 2 to 20 micrometers region of the infrared component or radiant flux. Distilled water was the reflectance standard. The angle of incidence was 70.03 deg plus or minus 0.23 deg. Absolute reflectances of the solutions for the same polarization and angle of incidence were computed by use of the measured relative reflectances, one of the Fresnel equations, and the optical constants of distilled water. Phase shift and phase difference spectra were obtained by respectively applying a Kramers-Kronig dispersion analysis to the absolute and relative reflectance spectra. The optical constants of the solutions were determined by algorithms commonly associated with the Kramers-Kronig analysis. Spectral signatures that qualitatively and quantitatively characterize the solute and that show structure of the infrared bands of water were noted in the phase difference spectra. The relative and absolute reflectances, the phase shift and phase difference spectra and the optical constants are presented in graphical form. Application of these results to remote sensing of the chemical quality of natural waters is discussed briefly.

Querr, M. R.↗

Cooled infrared telescope development

The feasibility of the design concept for a 1-m-aperture, cryogenically cooled telescope for Spacelab is assessed. The device makes use of double-folded Gregorian reflective optics. The planned cryogen is helium, and beryllium will be used for the 1.2 m primary mirror. Results of studies based on smaller instruments indicate that no new technology will be required to construct a Shuttle Infrared Telescope Facility which will offer improvement over the sensitivity of conventional telescopes by a factor of 1000 at 10 micrometers.

Young, L. S.↗

Damage to the photoreceptor cells of the rabbit retina from 56Fe ions: effect of age at exposure, 1

Optic and proximate tissues of New Zealand white (NZW) rabbits at ages (approximately 3.5 years) near the middle of their median lifespan (5-7 years) were given 0.5-3.5 Gy of 465 MeV u-1 56Fe ions in the Bragg plateau region of energy deposition at a linear energy transfer (LET infinity) of 220 +/- 31 keV micrometer-1. Dose-dependent losses of retinal photoreceptor cells (rods) occurred until 1-2 years after irradiation, the period of this interim report. Similar cumulative losses of photoreceptor cells were seen during the period 1-2 years post-irradiation for rabbits given comparable exposures when young (6-9 weeks old). Since losses of photoreceptor cells at early times had not been determined previously, the current experiment, which was designed to simulate the responses of mature astronauts, redressed that deficiency.

NASA Program NSCORT↗

Highly Saturated Glassy Liquid Crystal Films Having Nano- and Microscale Thicknesses for High-Power Laser Applications

The optical properties of glassy liquid crystals (GLC’s) designed to provide high resistance to laser-induced damage are explored. GLC’s readily enable freezing of the anisotropic ordering of liquid crystals into the glassy state. This solidity avoids issues of fluid leakage while providing mechanical robustness and the promise of single-substrate coatings or stand-alone films of nanometer to micron thicknesses. A series of three increasingly saturated GLC’s was synthesized and tested for their thin-film (hundreds of nanometers to tens of micrometers) high-peak-power laser-damage resistance with nanosecond pulses at 1053 nm, 532 nm, and 351 nm, as well as their durability under continuous-wave, broadband ultraviolet illumination. As a result, the GLC’s with higher degrees of saturation demonstrated high resistance to laser-induced damage, extending from the near infrared to the ultraviolet spectral region.

36 MATERIALS SCIENCE↗

Three-Dimensional Distribution of Ejecta in Supernova 1987A at 10,000 Days

Due to its proximity, SN 1987A offers a unique opportunity to directly observe the geometry of a stellar explosion as it unfolds. Here we present spectral and imaging observations of SN 1987A obtained approximately 10,000 days after the explosion with HST/STIS and VLT/SINFONI at optical and near-infrared wavelengths. These observations allow us to produce the most detailed 3D map of H(alpha) to date, the first 3D maps for [Ca II] lambda lambda 7292, 7324 [O I] lambda lambda 6300, 6364, and Mg II lambda lambda 9218, 9244, as well as new maps for [Si I] + [Fe II] 1.644 micrometers and He I 2.058 micrometers. A comparison with previous observations shows that the [Si I] + [Fe II] flux and morphology have not changed significantly during the past ten years, providing evidence that this line is powered by Ti-44. The time evolution of H(alpha) shows that it is predominantly powered by X-rays from the ring, in agreement with previous findings. All lines that have sufficient signal show a similar large-scale 3D structure, with a north-south asymmetry that resembles a broken dipole. This structure correlates with early observations of asymmetries, showing that there is a global asymmetry that extends from the inner core to the outer envelope. On smaller scales, the two brightest lines, Hα and [Si I]+[Fe II] 1.644 micrometers, show substructures at the level of approximately 200-1000 km s(exp -1) and clear differences in their 3D geometries. We discuss these results in the context of explosion models and the properties of dust in the ejecta.

Larsson, J.↗

A high-speed photographic system for flow visualization in a steam turbine

A photographic system was designed to visualize the moisture flow in a steam turbine. Good performance of the system was verified using dry turbine mockups in which an aerosol spray simulated, in a rough way, the moisture flow in the turbine. Borescopes and fiber-optic light tubes were selected as the general instrumentation approach. High speed motion-picture photographs of the liquid flow over the stator blade surfaces were taken using stroboscopic lighting. Good visualization of the liquid flow was obtained. Still photographs of drops in flight were made using short duration flash sources. Drops with diameters as small as 30 micrometers (0.0012 in.) could be resolved. In addition, motion pictures of a spray of water simulating the spray off the rotor blades and shrouds were taken at normal framing rates. Specially constructed light tubes containing small tungsten-halogen lamps were used. Sixteen millimeter photography was used in all cases. Two potential problems resulting from the two-phase turbine flow (attenuation and scattering of light by the fog present and liquid accumulation on the borescope mirrors) were taken into account in the photographic system design but not evaluated experimentally.

Barna, G. J.↗

Experiment K305: Quantitative analysis of selected bone parameters. Supplement 3A: Trabecular spacing and orientation in the long bones

Values of mean trabecular spacing computed from optical diffraction patterns of 1:1 X-ray micrographs of tibial metaphysis and those obtained by standard image digitization techniques show excellent agreement. Upper limits on values of mean trabecular orientation deduced from diffraction patterns and the images are also in excellent agreement. Values of the ratio of mean trabecular spatial density in a region of 300 micrometers distal to the downwardly directed convexity in the cartilage growth plate to the value adjacent to the plate determined for flight animals sacrificed at recovery were significantly smaller than values for vivarium control animals. No significant differences were found in proximal regions. No significant differences in mean trabecular orientation were detected. Decreased values of trabecular spatial density and of both obsteoblastic activity and trabecular cross-sectional area noted in collateral researches suggest decreased modeling activity under weightlessness.

Judy, M. M.↗

Measurements of thermal infrared spectral reflectance of frost, snow, and ice

Because much of Earth's surface is covered by frost, snow, and ice, the spectral emissivities of these materials are a significant input to radiation balance calculations in global atmospheric circulation and climate change models. Until now, however, spectral emissivities of frost and snow have been calculated from the optical constants of ice. We have measured directional hemispherical reflectance spectra of frost, snow, and ice from which emissivities can be predicted using Kirchhoff's law (e = 1-R). These measured spectra show that contrary to conclusions about the emissivity of snow drawn from previously calculated spectra, snow emissivity departs significantly from blackbody behavior in the 8-14 micrometer region of the spectrum; snow emissivity decreases with both increasing particle size and increasing density due to packing or grain welding; while snow emissivity increases due to the presence of meltwater.

Salisbury, John W.↗

Thermal transport across nanoscale damage profile in sapphire irradiated by swift heavy ions

In this work, we studied the degradation of thermal conductivity in single crystal sapphire (α-Al 2 O 3 ) irradiated by 167 MeV Xe swift heavy ions (SHIs) over the multiple fluences in the range of 10 12 –10 14 ions/cm 2 . Thermal conductivity was measured primarily in the cross-plane direction using a noncontact ultrafast optical pump-probe technique called picosecond time domain thermoreflectance (TDTR). Multiple samples with variable ion fluences allowed us to probe distinct regions resulting from different regimes of microstructure evolution caused by electronic energy loss. By tuning the penetration depth of the thermal waves using different modulation frequencies, two regions with distinct conductivities were identified and the values of which were found to be consistent with phonon-mediated thermal transport models while the microstructure was confirmed by electron microscopy characterization. These damaged regions were determined to be a several micrometer thick ion track region and several tens of nanometer-thick amorphous layer present only above 5.0 × 10 13 ions/cm 2 . These results demonstrate the applicability of TDTR to resolve thermal transport behavior in SHI irradiated oxides having nonhomogeneous damage profile on a nanometer scale. The presented approach facilitates future studies aiming at resolving the impact of distinct damage resulting from electronic and nuclear stopping regimes under irradiation.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

First-Principles Study of Casimir Repulsion in Metamaterials

We examine theoretically the Casimir effect between a metallic plate and several types of magnetic metamaterials in pursuit of Casimir repulsion, by employing a rigorous multiple-scattering theory for the Casimir effect. We first examine metamaterials in the form of two-dimensional lattices of inherently nonmagnetic spheres such as spheres made from materials possessing phonon-polariton and exciton-polariton resonances. Although such systems are magnetically active in infrared and optical regimes, the force between finite slabs of these materials and metallic slabs is plainly attractive since the effective electric permittivity is larger than the magnetic permeability for the studied spectrum. When lattices of magnetic spheres made from superparamagnetic composites are employed, we achieve not only Casimir repulsion but almost total suppression of the Casimir effect itself in the micrometer scale.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Coherent optical noise suppression device

The present work describes a scheme for a noise suppression system to be used with an afocal coherent optical data processor. The noise averaging scheme is based on the simple principle of moving input and output film planes together during exposure; the noise pattern remains stationary while the desired (filtered) image moves through it. The noise suppression system consists of a drive motor, right-angle gear box, reversing gear assemblage, right-angle gear drive, and micrometer adjusting translation tables. The device was tested by using a Sayce target containing fundamental spatial frequencies from 5 lines/mm to 100 lines/mm as the input signal. The output was photographed on Pan-X 35-mm film with and without the noise suppression system in operation. Microdensitometer scans of the exposed output film show that without noise averaging, resolution is good to about 80 lines/mm, while with noise averaging, it is good to about 35 lines/mm. A brief analysis of errors in the mechanical parts of the system reponsible for the upper limit of resolution is presented.

Horner, J. L.↗

Long Focal Length Large Mirror Fabrication System

The goals of this ambitious program are (1) to develop systems to make large superpolished optical mirrors, (2) to develop low scatter polishing techniques using centrifugal elutriation, (3) to develop a means of measuring scatter at any point on the mirror, (4) to polish a Hindle sphere to measure the optical figure of a one meter diameter convex mandrel, and (5) to fabricate low scatter, large adaptive optic graphite filled, cyanate ester replica transfer mirrors using these mandrels. Deliverables are a 30 cm diameter superpolished composite AO mirror. We fabricated a 1/3rd meter superpolished zerodur flat mandrel and with the support of our major subcontractor, Composite Mirror Applications Inc (CMA) we have demonstrated a 30 cm lightweight cyanate ester mirror with an rms microroughness between 0.6 and 0.8 nm and 8 faceplate influence function of 5 cm. The influence function was chosen to be comparable to the atmospheric correlation coefficient r(sub 0) which is about 5 cm at sea level. There was no print-thru of the graphite fibers in the cyanate ester surface (the bane of many previous efforts to use cyanate ester mirrors). Our subcontractor has devised a means for developing a 30-50 nm thick layer of graphite free pure ester resin on the surface of the mirrors. This graphite fiber filled material has a thermal expansion coefficient in the 10(exp -8) centimeter per Kelvin range (the same range of expansion coefficient as Zerodur and ULE glasses) and does not take up water and swell, so it is a nearly ideal mirror material in these areas. Unfortunately for these 0.8mm thick faceplates, the number of plies is not enough to result in isometric coverage. Isolated figure irregularities can appear, making it necessary to go to thicker faceplates. The influence function will then only approximate the length of r(sub 0), at higher altitudes or longer wavelengths. The influence function goes as the cube of the thickness, so we are now making a faceplate optimized for an infrared wavelength, possibly that used for the AO system of the Keck telescope, instead of 0.63 microns. We have polished a 55 cm diameter mandrel to better than 1/20th wave optical figure in the visible using centrifugal elutriation. CMA has just told us that it needs to retool to get optimum mirror faceplate quality in this size, so implementing the 55 cm AO mirror may be delayed somewhat. We expect to complete our 1/3 rd meter AO mirror on time using novel piezoelectric actuators with a throw of one micrometer per volt, as compared to 0.005 micrometers per volt for conventional piezoelectric actuators. We will then demonstrate its AO performance interferometrically.

Bennett, H. E.↗

Large active-area superconducting microwire detector array with single-photon sensitivity in the near-infrared

Superconducting nanowire single photon detectors (SNSPDs) are the highest-performing technology for time-resolved single-photon counting from the UV to the near-infrared. The recent discovery of single-photon sensitivity in micrometer-scale superconducting wires is a promising pathway to explore for large active area devices with application to dark matter searches and fundamental physics experiments. We present 8-pixel $1 mm^2$ superconducting microwire single photon detectors (SMSPDs) with $1\,\mathrm{\mu m}$-wide wires fabricated from WSi and MoSi films of various stoichiometries using electron-beam and optical lithography. Devices made from all materials and fabrication techniques show saturated internal detection efficiency at 1064 nm in at least one pixel, and the best performing device made from silicon-rich WSi shows single-photon sensitivity in all 8 pixels and saturated internal detection efficiency in 6/8 pixels. This detector is the largest reported active-area SMSPD or SNSPD with near-IR sensitivity published to date, and the first report of an SMSPD array. By further optimizing the photolithography techniques presented in this work, a viable pathway exists to realize larger devices with $cm^2$-scale active area and beyond.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Near-global survey of effective droplet radii in liquid water clouds using ISCCP data

A global survey of cloud particle size variations can provide crucial constraints on how cloud processes determine cloud liquid water contents and their variation with temperature, and further, may indicate the magnitude of aerosol effects on clouds. A method, based on a complete radiative transfer model for Advanced Very High Resolution Radiometer (AVHRR)-measured radiances, is described for retrieving cloud particle radii in liquid water clouds from satellite data currently available from the International Satellite Cloud Climatology Project. Results of sensitivity tests and validation studies provide error estimates. AVHRR data from NOAA-9 and NOAA-10 have been analyzed for January, April, July and October in 1987 and 1988. The results of this first survey reveal systematic continental and maritime differences and hemispheric contrasts that are indicative of the effects of associated aerosol concentration differences: cloud droplet radii in continental water clouds are about 2-3 micrometers smaller than in marine clouds, and droplet radii are about 1 micrometer smaller in marine clouds of the Northern Hemisphere than in the Southern Hemisphere. The height dependencies of cloud droplet radii in continental and marine clouds are also consistent with differences in the vertical profiles of aerosol concentration. Significant seasonal and diurnal variations of effective droplet radii are also observed, particularly at lower latitudes. Variations of the relationship between cloud optical thickness and droplet radii may indicate variations in cloud microphysical regimes.

Han, Qingyan↗

Growth of Homoepitaxial ZnO Semiconducting Films

As a high temperature semiconductor, ZnO has been used for many applications such as wave-guide, solar cells, and surface acoustic wave devices. Since the ZnO material has an energy gap of 3.3 eV at room temperature and an excitonic binding energy (60 meV) that is possible to make excitonic lasering at room temperature a recent surge of interest is to synthesize ZnO films for electro-optical devices. These applications require films with a smooth surface, good crystal quality, and low defect density. Homoepitaxial films have been studied in terms of morphology, crystal structure, and electrical and optical properties. ZnO single crystals are grown by the hydrothermal method. Substrates are mechanically polished and annealed in air for four hours before deposited films. The annealing temperature-dependence of ZnO substrates is studied. Films are synthesized by the off-axis reactive sputtering deposition. The films have very smooth surface with a roughness </= 5 nm on a 5 micrometers x 5 micrometers area. The full width at half maximum of film theta rocking curves measured by the x-ray diffraction is slightly larger than the crystal substrate. The film quality is determined by measuring the film resistivity, the Hall mobility, carrier densities and the energy band gap. The properties of ZnO films grown of (0001) ZnO and (0001) sapphire substrates will be also compared and discussed in the presentation.

Zhu, Shen↗