Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Optical Detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

The Primordial Inflation Explorer (PIXIE) Mission

The Primordial Inflation Explorer (PIXIE) is an Explorer-class mission to map the absolute intensity and linear polarization of the cosmic microwave background and diffuse astrophysical foregrounds over the full sky from frequencies 30 GHz to 6 THz (I cm to 50 I-tm wavelength). PIXIE uses a polarizing Michelson interferometer with 2.7 K optics to measure the difference spectrum between two orthogonal linear polarizations from two co-aligned beams. Either input can view either the sky or a temperature-controlled absolute reference blackbody calibrator. The multimoded optics and high etendu provide sensitivity comparable to kilo-pixel focal plane arrays, but with greatly expanded frequency coverage while using only 4 detectors total. PIXIE builds on the highly successful COBEIFIRAS design by adding large-area polarization-sensitive detectors whose fully symmetric optics are maintained in thermal equilibrium with the CMB. The highly symmetric nulled design provides redundant rejection of major sources of systematic uncertainty. The principal science goal is the detection and characterization of linear polarization from an inflationary epoch in the early universe, with tensor-to-scalar ratio r much less than 10(exp -3). PIXIE will also return a rich data set constraining physical processes ranging from Big Bang cosmology, reionization, and large-scale structure to the local interstellar medium. Keywords: cosmic microwave background, polarization, FTS, bolometer

Kogut, Alan J.↗

Integrated optics technology study

The materials and processes available for the fabrication of single mode integrated electrooptical components are described. Issues included in the study are: (1) host material and orientation, (2) waveguide formation, (3) optical loss mechanisms, (4) wavelength selection, (5) polarization effects and control, (6) laser to integrated optics coupling,(7) fiber optic waveguides to integrated optics coupling, (8) souces, (9) detectors. The best materials, technology and processes for fabrication of integrated optical components for communications and fiber gyro applications are recommended.

Chen, B.↗

Reduction of the one-dimensional X-ray scattering data on mirror flats at NASA/Marshall Space Flight Center

Data on the scattering of X-rays from various mirror flats obtained from different vendors. The scattering data discussed in this section is obtained by a one dimensional proportional counter at X-ray energies of 8.06, 6.4 and 2.99 keV. X-rays are generated at one end of a 312.4m long tube which is under vacuum. This long tube provides a parallel beam of X-rays which is then collimated by a slit and allowed to scatter from a pair of mirror flats at small grazing angles of incidence. The slit and mirrors assembly is placed 182.4 meters from the other end of the tube where the proportional counter detector is located. The detector is sitting on an optical table which is pivoted so that it can rotate to intercept X-rays at a range of spatial locations. The optical table pivot is located 2.78 meters in front of the detector, and has an operational angular range of 350 arc minutes. Measured from the position of the mirror, this total angular range of the data is (350) (2.78/182.4) = 5.33 arcminutes.

Williams, A. C.↗

Emulating the visual receptive-field properties of MST neurons with a template model of heading estimation

We have proposed previously a computational neural-network model by which the complex patterns of retinal image motion generated during locomotion (optic flow) can be processed by specialized detectors acting as templates for specific instances of self-motion. The detectors in this template model respond to global optic flow by sampling image motion over a large portion of the visual field through networks of local motion sensors with properties similar to those of neurons found in the middle temporal (MT) area of primate extrastriate visual cortex. These detectors, arranged within cortical-like maps, were designed to extract self-translation (heading) and self-rotation, as well as the scene layout (relative distances) ahead of a moving observer. We then postulated that heading from optic flow is directly encoded by individual neurons acting as heading detectors within the medial superior temporal (MST) area. Others have questioned whether individual MST neurons can perform this function because some of their receptive-field properties seem inconsistent with this role. To resolve this issue, we systematically compared MST responses with those of detectors from two different configurations of the model under matched stimulus conditions. We found that the characteristic physiological properties of MST neurons can be explained by the template model. We conclude that MST neurons are well suited to support self-motion estimation via a direct encoding of heading and that the template model provides an explicit set of testable hypotheses that can guide future exploration of MST and adjacent areas within the superior temporal sulcus.

NASA Discipline Neuroscience↗

Energy Calibration of the Scintillating Optical Fiber Calorimeter Chamber (SOFCAL)

The Scintillating Optical Fiber Calorimeter (SOFCAL) detector is designed to make direct measures of the primary cosmic ray spectrum from -200 GeV/amu - 20 TeV/amu. The primary particles are resolved into groups according to their charge (p, He, CNO, Medium Z, Heavy Z) using both active and passive components integrated into the detector. The principal part of SOFCAL is a thin ionization calorimeter that measures the electromagnetic cascades that result from these energetic particles interacting in the detector. The calorimeter is divided into two sections: a thin passive emulsion/x-ray film calorimeter, and a fiber calorimeter that uses crossing layers of small scintillating optical fibers to sample the energy deposition of the cascades. The energy determination is made by fitting the fiber data to transition curves generated by Monte Carlo simulations. The fiber data must first be calibrated using the electron counts from the emulsion plates in the calorimeter for a small number of events. The technique and results of this calibration will be presented together with samples of the data from a balloon flight.

Christl, M. C.↗

Fiber-optic delay-line stabilization of heterodyne optical signal generator and method using same

The present invention is a laser heterodyne frequency generator system with a stabilizer for use in the microwave and millimeter-wave frequency ranges utilizing a photonic mixer as a photonic phase detector in a stable optical fiber delay-line. Phase and frequency fluctuations of the heterodyne laser signal generators are stabilized at microwave and millimeter wave frequencies by a delay line system operating as a frequency discriminator. The present invention is free from amplifier and mixer 1/.function. noise at microwave and millimeter-wave frequencies that typically limit phase noise performance in electronic cavity stabilized electronic oscillators. Thus, 1/.function. noise due to conventional mixers is eliminated and stable optical heterodyne generation of electrical signals is achieved.

Logan, Ronald T.↗

The prototype MOSAIC detector

The prototype of the MOSAIC (Mosaicked Optical Self-scanned Array Imaging Camera) system, a photon-counting detector designed for use in the far ultraviolet, is described. MOSAIC has a two-dimensional format of 2400 x 2400 pixels, and is easily expandable. Readout is accomplished electronically via charge-coupled devices, making possible remote observations. Preliminary results of computer simulations of the system are presented.

Weistrop, D.↗

Centroid tracking with area array detectors

A computer program (ALGEVAL) has been developed to simulate the position estimating behavior of a centroid estimator algorithm using data typical of optical point spread function data recorded by an area array detector. Typical results are shown of varying detector properties and optical point spread function types. The detector parameters currently available for study include read noise mean value, dark current mean value and spatial variation, charge transfer efficiency and point spread function location, saturation level, signal level and pixel size. The program is capable of calculating any order centroid using an array size from 2 x 2 to 15 x 15 pixels. The output of the program is either a performance map, histogram data or tabluar data. A number of further developments are recommended.

Glavich, T. A.↗

Characterization and Modeling of Indium Gallium Antimonide Avalanche Photodiode and of Indium Gallium Arsenide Two-band Detector

A model of the optical properties of Al(x)Ga(1-x)As(y)Sb(1-y) and In(x)Ga(1-x)As(y)Sb(1-y) is presented, including the refractive, extinction, absorption and reflection coefficients in terms of the optical dielectric function of the materials. Energy levels and model parameters for each binary compound are interpolated to obtain the needed ternaries and quaternaries for various compositions. Bowing parameters are considered in the interpolation scheme to take into account the deviation of the calculated ternary and quaternary values from experimental data due to lattice disorders. The inclusion of temperature effects is currently being considered.

Source record↗

Micro spectrometer for parallel light and method of use

A spectrometer system includes an optical assembly for collimating light, a micro-ring grating assembly having a plurality of coaxially-aligned ring gratings, an aperture device defining an aperture circumscribing a target focal point, and a photon detector. An electro-optical layer of the grating assembly may be electrically connected to an energy supply to change the refractive index of the electro-optical layer. Alternately, the gratings may be electrically connected to the energy supply and energized, e.g., with alternating voltages, to change the refractive index. A data recorder may record the predetermined spectral characteristic. A method of detecting a spectral characteristic of a predetermined wavelength of source light includes generating collimated light using an optical assembly, directing the collimated light onto the micro-ring grating assembly, and selectively energizing the micro-ring grating assembly to diffract the predetermined wavelength onto the target focal point, and detecting the spectral characteristic using a photon detector.

Park, Yeonjoon↗

The Scintillating Optical Fiber Isotope Experiment

This paper describes the Scintillating Optical Fiber Isotope Experiment (SOFIE) which is being developed by Washington University and the University of New Hampshire to study the abundances of cosmic ray isotopes in the iron charge region. This detector system is a Cerenkov-Range-dE/dx experiment and utilizes range and trajectory detectors made of scintillating optical fibers, a fused silica Cerenkov counter, and plastic scintillator dE/dx counters to determine the charge and mass of cosmic ray nuclei. A brief description of the balloon flight instrument presently being developed will be given followed by initial results of an engineering model calibration at the LBL Bevalac heavy ion accelerator. In addition a brief discussion of the potential of scintillating fiber trajectory detectors for use in experiments requiring precise trajectory determination such as those being planned for the NASA Particle Astrophysics Magnet Facility (Astromag) program is presented.

Binns, W. Robert↗

Faint-object spectrograph for Space Telescope

The paper presents the Faint Object Spectrograph (FOS) for the Space Telescope to provide a digitized spectra of faint astronomical objects over the 115 to 700 nm wavelength range at resolving powers of 1000 and 100. A variety of concave gratings and prisms is employed to form nearly stigmatic spectra on one of the two Digicon photon counting detectors which are optimized for two different but overlapping ranges. The scientific goals associated with quasars, active galaxies, and objects within our solar system are discussed, and the FOS optical design features, including detectors, electronics, signal processing, power supplies, and data handling are examined. The FOS structural system, mechanism, and controls are described, along with the predicted performance capabilities in the spectral and spectropolarimetry modes. Finally, system performance parameters, including spatial resolution, time resolution, noise, and efficiency are discussed.

Harms, r. J.↗

Ambient and Cryogenic Alignment Verification and Performance of the Infrared Multi-Object Spectrometer

The Infrared Multi-Object Spectrometer (IRMOS) is a facility instrument for the Kitt Peak National Observatory 4 and 2.1 meter telescopes. IRMOS is a near-IR (0.8 - 2.5 micron) spectrometer with low- to mid-resolving power (R = 300 - 3000). IRMOS produces simultaneous spectra of approximately 100 objects in its 2.8 x 2.0 arc-min field of view using a commercial Micro Electro-Mechanical Systems (MEMS) Digital Micro-mirror Device (DMD) from Texas Instruments. The IRMOS optical design consists of two imaging subsystems. The focal reducer images the focal plane of the telescope onto the DMD field stop, and the spectrograph images the DMD onto the detector. We describe ambient breadboard subsystem alignment and imaging performance of each stage independently, and the ambient and cryogenic imaging performance of the fully assembled instrument. Interferometric measurements of subsystem wavefront error serve to venfy alignment, and are accomplished using a commercial, modified Twyman-Green laser unequal path interferometer. Image testing provides further verification of the optomechanical alignment method and a measurement of near-angle scattered light due to mirror small-scale surface error. Image testing is performed at multiple field points. A mercury-argon pencil lamp provides spectral lines at 546.1 nm and 1550 nm, and a CCD camera and IR camera are used as detectors. We use commercial optical modeling software to predict the point-spread function and its effect on instrument slit transmission and resolution. Our breadboard test results validate this prediction. We conclude with an instrument performance prediction for first light.

Connelly, Joseph A.↗

Alignment and Performance of the Infrared Multi-Object Spectrometer

The Infrared Multi-Object Spectrometer (IRMOS) is a principle investigator class instrument for the Kitt Peak National Observatory 4 and 2.1 meter telescopes. IRMOS is a near-IR (0.8 - 2.5 micron) spectrometer with low-to mid-resolving power (R = 300 - 3000). IRMOS produces simultaneous spectra of approximately 100 objects in its 2.8 x 2.0 arc-min field of view (4 m telescope) using a commercial Micro Electro-Mechanical Systems (MEMS) micro-mirror array (MMA) from Texas Instruments. The IRMOS optical design consists of two imaging subsystems. The focal reducer images the focal plane of the telescope onto the MMA field stop, and the spectrograph images the MMA onto the detector. We describe ambient breadboard subsystem alignment and imaging performance of each stage independently, and ambient imaging performance of the fully assembled instrument. Interferometric measurements of subsystem wavefront error serve as a qualitative alignment guide, and are accomplished using a commercial, modified Twyman-Green laser unequal path interferometer. Image testing provides verification of the optomechanical alignment method and a measurement of near-angle scattered light due to mirror small-scale surface error. Image testing is performed at multiple field points. A mercury-argon pencil lamp provides a spectral line at 546.1 nanometers, a blackbody source provides a line at 1550 nanometers, and a CCD camera and IR camera are used as detectors. We use commercial optical modeling software to predict the point-spread function and its effect on instrument slit transmission and resolution. Our breadboard and instrument level test results validate this prediction. We conclude with an instrument performance prediction for cryogenic operation and first light in late 2003.

Connelly, Joseph A.↗

TESS Lens-Bezel Assembly Modal Testing

The Transiting Exoplanet Survey Satellite (TESS) program, led by the Kavli Institute for Astrophysics and Space Research at the Massachusetts Institute of Technology (MIT) will be the first-ever spaceborne all-sky transit survey. MIT Lincoln Laboratory is responsible for the cameras, including the lens assemblies, detector assemblies, lens hoods, and camera mounts. TESS is scheduled to be launched in August of 2017 with the primary goal to detect small planets with bright host starts in the solar neighborhood, so that detailed characterizations of the planets and their atmospheres can be performed. The TESS payload consists of four identical cameras and a data handling unit. Each camera consists of a lens assembly with seven optical elements and a detector assembly with four charge-coupled devices (CCDs) including their associated electronics. The optical prescription requires that several of the lenses are in close proximity to a neighboring element. A finite element model (FEM) was developed to estimate the relative deflections between each lens-bezel assembly under launch loads to predict that there are adequate clearances preventing the lenses from making contact. Modal tests using non-contact response measurements were conducted to experimentally estimate the modal parameters of the lens-bezel assembly, and used to validate the initial FEM assumptions. Key Words Non-contact measurements, modal analysis, model validation

Modal Testing↗

Emulating the Visual Receptive Field Properties of MST Neurons with a Template Model of Heading Estimation

We have previously proposed a computational neural-network model by which the complex patterns of retinal image motion generated during locomotion (optic flow) can be processed by specialized detectors acting as templates for specific instances of self-motion. The detectors in this template model respond to global optic flow by sampling image motion over a large portion of the visual field through networks of local motion sensors with properties similar to neurons found in the middle temporal (MT) area of primate extrastriate visual cortex. The model detectors were designed to extract self-translation (heading), self-rotation, as well as the scene layout (relative distances) ahead of a moving observer, and are arranged in cortical-like heading maps to perform this function. Heading estimation from optic flow has been postulated by some to be implemented within the medial superior temporal (MST) area. Others have questioned whether MST neurons can fulfill this role because some of their receptive-field properties appear inconsistent with a role in heading estimation. To resolve this issue, we systematically compared MST single-unit responses with the outputs of model detectors under matched stimulus conditions. We found that the basic physiological properties of MST neurons can be explained by the template model. We conclude that MST neurons are well suited to support heading estimation and that the template model provides an explicit set of testable hypotheses which can guide future exploration of MST and adjacent areas within the primate superior temporal sulcus.

Perrone, John A.↗

Fiber optic sensors

A survey of the developments in the field of fiber optics sensor technology is presented along with a discussion of the advantages of optical measuring instruments as compared with electronic sensors. The two primary types of fiber optics sensors, specifically those with multiwave fibers and those with monowave fibers, are described. Examples of each major sensor type are presented and discussed. Multiwave detectors include external and internal fiber optics sensors. Among the monowave detectors are Mach-Zender interferometers, Michelson interferometers, Sagnac interferometers (optical gyroscopes), waveguide resonators, and polarimeter sensors. Integrated optical sensors and their application in spectroscopy are briefly discussed.

Hesse, J.↗

Efficient Mirrorlet Array Based Integral Field Spectrometer (IFS) for HWO

Habitable World Observatory (HWO) is a NASA strategic mission recommended by 2020 astronomical decadal survey. Integral field spectrometers play an important role to verify if the observed exoplanet is habitable. The traditional lenslet array based IFS has the advantage of simplicity and compactness. However, it does not use detector pixels efficiently in order to prevent wavelength crosstalk among adjacent spectra. The efficient lenslet/mirrorlet IFS combines the advantages from both lenslet based and imager slicer based IFSes—keeping lenslet IFS’s simplicity and compactness, and adding slicer IFS’s detector efficiency. This paper discusses the principle of efficient lenslet/mirrorlet IFS, design philosophy, and efficient spectral trace layout ideals. It uses HWO NIR IFS requirement as an example to provide an efficiency mirrorlet IFS optical design. The high detector efficiency not only reduces needed detector pixel numbers, but also reduces the high communication rate demanding for such a large multiple instrument mission.

Qian Gong↗