Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Occupancy distribution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

In Situ Characterization of CuFe2O4 and Cu/Fe3O4 Water-Gas Shift Catalysts

Mixtures of copper and iron oxides are used as industrial catalysts for the water-gas shift (WGS, CO + H2O f H2 + CO2). In-situ time-resolved X-ray diffraction, X-ray absorption fine structure, and atomic pair distribution function analysis were used to study the reduction of CuFe2O4 with CO and the behavior of CuFe2O4 and Cu/Fe2O3 catalysts under WGS reaction conditions. MetalToxygenTmetal interactions enhance the stability of Cu 2+ and Fe 3+ in the CuFe2O4 lattice, and the mixed-metal oxide is much more difficult to reduce than CuO or Fe2O3. Furthermore, after heating mixtures of CuFe2O4/CuO in the presence of CO or CO/H2O, the cations of CuO migrate into octahedral sites of the CuFe2O4 lattice at temperatures (200-250 C) in which CuO is not stable. Above 250 C, copper leaves the oxide, the occupancy of the octahedral sites in CuFe2O4 decreases, and diffraction lines for metallic Cu appear. From 350 to 450 C, there is a massive reduction of CuFe2O4 with the formation of metallic Cu and Fe3O4. At this point, the sample becomes catalytically active for the production of H2 from the reaction of H2O with CO. Neutral Cu 0 (i.e., no Cu 1+ or Cu 2+ cations) is the active species in the catalysts, but interactions with the oxide support cannot be neglected. These studies illustrate the importance of in situ characterization when dealing with mixed-metal oxide WGS catalysts.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The good, the bad, and the ugly: Data-driven load profile discord identification in a large building portfolio

Reducing the overall energy consumption and associated greenhouse gas emissions in the building sector is essential for meeting our future sustainability goals. Recently, smart energy metering facilities have been deployed to enable monitoring of energy consumption data with hourly or subhourly temporal resolution. This unprecedented data collection has created various opportunities for advanced data analytics involving load profiles (e.g., building energy benchmarking programs, building-to-grid integration, and calibration of urban-scale energy models). These applications often need preprocessing steps to detect daily load profile discords, such as: 1) outliers due to system malfunctions (the bad) and 2) irregular energy consumption patterns, such as those resulting from holidays (the ugly) compared to normal consumption patterns (the good). However, current preprocessing methods predominantly focus on filtering using statistical threshold values, which fail to capture the contextual discords of daily profiles. In addition, discord detection algorithms in building research are often aimed at finding individual building-level discords, which are not suitable at a large scale. Thus, here, we develop a method for automated load profile discord identification (ALDI) in a large portfolio of buildings (more than 100 buildings). Specifically, ALDI 1) uses the matrix profile (MP) method to quantify the similarities of daily subsequences in time series meter data, 2) compares daily MP values with typical-day MP distributions using the Kolmogorov-Smirnov test, and 3) identifies daily load profile discords in a large building portfolio. We evaluate ALDI using the metering data of both an academic campus and a residential neighborhood. Our results demonstrate that ALDI efficiently discovers measurement errors by system malfunctions and low energy consumption days in the academic campus portfolio, and it detects unique load shape patterns likely driven by occupant behavior and extreme weather conditions in the residential neighborhood.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Influence of interstitial Mn on local structure and magnetism in Mn 1 + δ Sb

We report x-ray total scattering and pair distribution function (PDF) studies of the structural relaxation around interstitial manganese (Mn i ) in ferromagnetic Mn 1+δ Sb (0.03 ≤ δ ≤ 0.23) alloys, guided by density functional theory (DFT). Refinements to the experimental PDF using a crystallographically constrained structural model indicate an expansion in the equatorial plane of the Mn i Sb 5 trigonal bipyramidal site, which introduces significant positional disorder in addition to the nominally random occupation of interstitial voids. Observation of a weak diffuse signal near the symmetry-forbidden (001) reflection position is indicative of correlated disorder from the clustering of Mn i . Density functional relaxation of supercells approximating the δ = 0.08, 0.15, and 0.23 compositions provides improved models that accurately describe the short-range structural distortions captured in the PDFs. Furthermore, such structural relaxation increases the DFT calculated moment on Mn i , which aligns antiparallel to the primary Mn moments, but leads to insubstantial changes in the average Mn and Sb moments and moments of Mn and Sb proximal to interstitials, thus providing a more accurate description of the observed bulk magnetic properties.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

In-situ Characterization of CuFe2O4 and Cu/Fe3O4 Water-Gas Shift Catalysts

Mixtures of copper and iron oxides are used as industrial catalysts for the water-gas shift (WGS, CO + H2O → H2 + CO2). In-situ time-resolved X-ray diffraction, X-ray absorption fine structure, and atomic pair distribution function analysis were used to study the reduction of CuFe2O4 with CO and the behavior of CuFe2O4 and Cu/Fe2O3 catalysts under WGS reaction conditions. Metal↔oxygen↔metal interactions enhance the stability of Cu2+ and Fe3+ in the CuFe2O4 lattice, and the mixed-metal oxide is much more difficult to reduce than CuO or Fe2O3. Furthermore, after heating mixtures of CuFe2O4/CuO in the presence of CO or CO/H2O, the cations of CuO migrate into octahedral sites of the CuFe2O4 lattice at temperatures (200-250 oC) in which CuO is not stable. Above 250 oC, copper leaves the oxide, the occupancy of the octahedral sites in CuFe2O4 decreases, and diffraction lines for metallic Cu appear. From 350 to 450 oC, there is a massive reduction of CuFe2O4 with the formation of metallic Cu and Fe3O4. At this point, the sample becomes catalytically active for the production of H2 from the reaction of H2O with CO. Neutral Cu0 (i.e. no Cu+1 or Cu+2 cations) is the active species in the catalysts, but interactions with the oxide support are necessary in order to obtain high catalytic activity. These studies illustrate the importance of in-situ characterization when dealing with mixed-metal oxide WGS catalysts.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A synthetic building operation dataset

Abstract This paper presents a synthetic building operation dataset which includes HVAC, lighting, miscellaneous electric loads (MELs) system operating conditions, occupant counts, environmental parameters, end-use and whole-building energy consumptions at 10-minute intervals. The data is created with 1395 annual simulations using the U.S. DOE detailed medium-sized reference office building, and 30 years’ historical weather data in three typical climates including Miami, San Francisco, and Chicago. Three energy efficiency levels of the building and systems are considered. Assumptions regarding occupant movements, occupants’ diverse temperature preferences, lighting, and MELs are adopted to reflect realistic building operations. A semantic building metadata schema - BRICK, is used to store the building metadata. The dataset is saved in a 1.2 TB of compressed HDF5 file. This dataset can be used in various applications, including building energy and load shape benchmarking, energy model calibration, evaluation of occupant and weather variability and their influences on building performance, algorithm development and testing for thermal and energy load prediction, model predictive control, policy development for reinforcement learning based building controls.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Comfort and Safety Metrics to Evaluate Customer Centric Resilience Enhancement Strategies

As the coincident events of extreme weather and major power outages continue to rise there is an increased need to implement resilience solutions. Many of these solutions are customer-centric, requiring the flexibility of demand, and many of the standard economic evaluations of these solutions do not include the benefits of resilience that are not easily quantified and monetized. Indoor air temperature has a large impact on the comfort and safety of building occupants during an extreme weather event. This work proposes metrics that can be used to compare the performance of resilience solutions in the context of comfort and safety.

Cost benefit analysis, Demand Side Management, Pow↗

Energy Conservation Projects to Benefit the Railroad Industry

The Energy Conservation Projects to benefit the railroad industry using the Norfolk Southern Company as a model for the railroad industry has five unique tasks which are in areas of importance within the rail industry, and specifically in the area of energy conservation. The NIU Engineering and Technology research team looked at five significant areas in which research and development work can provide unique solutions to the railroad industry in energy the conservation. (1) Alternate Fuels - An examination of various blends of bio-based diesel fuels for the railroad industry, using Norfolk Southern as a model for the industry. The team determined that bio-diesel fuel is a suitable alternative to using straight diesel fuel, however, the cost and availability across the country varies to a great extent. (2) Utilization of fuel cells for locomotive power systems - While the application of the fuel cell has been successfully demonstrated in the passenger car, this is a very advanced topic for the railroad industry. There are many safety and power issues that the research team examined. (3) Thermal and emission reduction for current large scale diesel engines - The current locomotive system generates large amount of heat through engine cooling and heat dissipation when the traction motors are used to decelerate the train. The research team evaluated thermal management systems to efficiently deal with large thermal loads developed by the operating engines. (4) Use of Composite and Exotic Replacement Materials - Research team redesigned various components using new materials, coatings, and processes to provide the needed protection. Through design, analysis, and testing, new parts that can withstand the hostile environments were developed. (5) Tribology Applications - Identification of tribology issues in the Railroad industry which play a significant role in the improvement of energy usage. Research team analyzed and developed solutions which resulted in friction modification to improve energy efficiency.

24 POWER TRANSMISSION AND DISTRIBUTION↗

How Well Does the Latest Anthropomorphic Test Device Mimic Human Impact Responses?

One of the goals of the NASA Occupant Protection Group is to understand the human tolerance to dynamic loading. This knowledge has to come through indirect approaches such as existing human response databases, anthropometric test devices (ATD), animal testing, post‐mortem human subjects, and models. This study investigated the biofidelity of the National Highway Traffic Safety Administration's ATD named the THOR (test device for human occupant restraint). If THOR responds comparably to humans, then it could potentially be used as a human surrogate to help validate space vehicle requirements for occupant protection. The THOR responses to frontal and spinal impacts (ranging from 8 to 12 G with rise times of 40, 70, and 100 ms) were measured and compared to human volunteer responses (95 trials in frontal and 58 in spinal) previously collected by the U. S. Air Force on the same horizontal impact accelerator. The impact acceleration profiles tested are within the expected range of multi‐purpose crew vehicle (MPCV) landing dynamics. A correlation score was calculated for each THOR to human comparison using CORA (CORrelation and Analysis) software. A two‐parameter beta distribution model fit was obtained for each dependent variable using maximum likelihood estimation. For frontal impacts, the THOR head x‐acceleration peak response correlated with the human response at 8 and 10‐G 100 ms but not 10‐G 70 ms. The phase lagged the human response. Head z‐acceleration was not correlated. Chest x‐acceleration was in phase, had a higher peak response, and was well correlated with lighter subjects (Cora = 0.8 for 46 kg vs. Cora = 0.4 for 126 kg). Head x‐displacement had a leading phase. Several subjects responded with the same peak displacement but the mean of the group was lower. The shoulder x‐displacement was in phase but had higher peaks than the human response. For spinal impacts, the THOR head x‐acceleration was not well correlated. Head and chest z‐acceleration was in phase but had a higher peak response. Chest z‐acceleration was highly correlated with heavier subjects at lower G pulses (Cora = 0.86 for 125 kg at 8 G). The human response was variable in shoulder z‐displacement but the THOR was in phase and was comparable to the mean peak response. Head xand z‐displacement was in phase but had higher peaks. Seat pan forces were well correlated, were in phase, but had a larger peak response than most subjects. The THOR does not respond to frontal and spinal impacts exactly the same way that a human does. Some responses are well matched and others are not. Understanding the strengths and weaknesses of this ATD is an important first step in determining its usefulness in occupant protection at NASA

Newby, N.↗

How Well Does the Latest Anthropomorphic Test Device Mimic Human Impact Responses?

One of the goals of the NASA Occupant Protection Group is to understand the human tolerance to dynamic loading. This knowledge has to come through indirect approaches such as existing human response databases, anthropometric test devices (ATD), animal testing, post-­‐mortem human subjects, and models. This study investigated the biofidelity of the National Highway Traffic Safety Administration's ATD named the THOR (test device for human occupant restraint). If THOR responds comparably to humans, then it could potentially be used as a human surrogate to help validate space vehicle requirements for occupant protection. The THOR responses to frontal and spinal impacts (ranging from 8 to 12 G with rise times of 40, 70, and 100 ms) were measured and compared to human volunteer responses (95 trials in frontal and 58 in spinal) previously collected by the U. S. Air Force on the same horizontal impact accelerator. The impact acceleration profiles tested are within the expected range of multi-­‐purpose crew vehicle (MPCV) landing dynamics. A correlation score was calculated for each THOR to human comparison using CORA (CORrelation and Analysis) software. A two-­‐parameter beta distribution model fit was obtained for each dependent variable using maximum likelihood estimation. For frontal impacts, the THOR head x-­‐acceleration peak response correlated with the human response at 8 and 10-­‐G 100 ms but not 10-­‐G 70 ms. The phase lagged the human response. Head z-­‐acceleration was not correlated. Chest x-­‐acceleration was in phase, had a higher peak response, and was well correlated with lighter subjects (Cora = 0.8 for 46 kg vs. Cora = 0.4 for 126 kg). Head x-­‐displacement had a leading phase. Several subjects responded with the same peak displacement but the mean of the group was lower. The shoulder x-­‐displacement was in phase but had higher peaks than the human response. For spinal impacts, the THOR head x-­‐acceleration was not well correlated. Head and chest z-­‐acceleration was in phase but had a higher peak response. Chest z-­‐acceleration was highly correlated with heavier subjects at lower G pulses (Cora = 0.86 for 125 kg at 8 G). The human response was variable in shoulder z-­‐displacement but the THOR was in phase and was comparable to the mean peak response. Head x-­‐ and z-­‐displacement was in phase but had higher peaks. Seat pan forces were well correlated, were in phase, but had a larger peak response than most subjects. The THOR does not respond to frontal and spinal impacts exactly the same way that a human does. Some responses are well matched and others are not. Understanding the strengths and weaknesses of this ATD is an important first step in determining its usefulness in occupant protection at NASA

Newby, Nate↗

The effect of classical and quantum dynamics on vibrational frequency shifts of H{sub 2} in clathrate hydrates

Vibrational frequency shifts of H{sub 2} in clathrate hydrates are important to understand the properties and elucidate details of the clathrate structure. Experimental spectra of H{sub 2} in clathrate hydrates have been measured for different clathrate compositions, temperatures, and pressures. In order to establish reliable relationships between the clathrate structure, dynamics, and observed frequencies, calculations of vibrational frequency shifts in different clathrate environments are required. In this study, a combination of classical molecular dynamics simulations, electronic structure calculations, and quantum dynamical simulation is used to calculate relative vibrational frequencies of H{sub 2} in clathrate hydrates. This approach allows us to assess dynamical effects and simulate the change of vibrational frequencies with temperature and pressure. The frequency distributions of the H{sub 2} vibrations in the different clathrate cage types agree favorably with experiment. Also, the simulations demonstrate that H{sub 2} in the 5{sup 12} cage is more sensitive to the details of the environment and to quantum dynamical effects, in particular when the cage is doubly occupied. We show that for the 5{sup 12} cage quantum effects lead to frequency increases and double occupation is unlikely. This is different for the 5{sup 12}6{sup 4} cages for which higher occupation numbers than one H{sub 2} per cage are likely.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Secure mmWave Spectrum Sharing with Autonomous Beam Scheduling for 5G and Beyond

Spectrum Sharing (SS) has seen a renewed set of initiatives in 5G with the availability of shared and unlicensed spectrum bands that can be used by multiple cellular service providers and private cellular networks. Beam based transmission, instead of the traditional sector based transmission in conjunction with the spectrum agility of the 5G New Radio (NR) has brought new opportunities to optimized sharing of spectrum. Currently in the U.S., a centralized Spectrum Access Server (SAS) is used to co-ordinate spectrum sharing among networks sharing the same spectrum band. However, SAS becomes a focal point for security attacks and a performance bottleneck. In addition, SAS relies on an Environmental Sensor Network (ESN), separate from the 5G network. Without trusted spectral occupancy information, false reporting of spectrum sensing data can create sub-optimal and unfair spectrum usage. This paper summarizes our recent research findings in using a decentralized scheme for multiple networks to securely share spectrum with autonomous beam scheduling : 1) A new stochastic network framework based on Lyapunov Optimization approach is developed to optimize scheduling at the base stations; 2) Game theoretic (GT) approach is used to formulate the distributed scheduler; 3) Another distributed scheduler with Q-learning is presented that utilizes the Reinforcement Learning (RL) approach; 4) The performance and convergence rate of these distributed solutions to use shared and unlicensed spectrum are compared with existing solutions. Conditions under which the performance of these schedulers approach the theoretical upper bound, which is the performance possible with no interference among the operators sharing the spectrum, are presented; 5) The ability of a base station to use its own user equipment as sensors, for optimal spectrum sharing with base stations in other operator networks, is demonstrated to be an effective approach.

5G↗

WHISPER: Wireless Home Identification and Sensing Platform for Energy Reduction

Many regions of the world benefit from heating, ventilating, and air-conditioning (HVAC) systems to provide productive, comfortable, and healthy indoor environments, which are enabled by automatic building controls. Due to climate change, population growth, and industrialization, HVAC use is globally on the rise. Unfortunately, these systems often operate in a continuous fashion without regard to actual human presence, leading to unnecessary energy consumption. As a result, the heating, ventilation, and cooling of unoccupied building spaces makes a substantial contribution to the harmful environmental impacts associated with carbon-based electric power generation, which is important to remedy. For our modern electric power system, transitioning to low-carbon renewable energy is facilitated by integration with distributed energy resources. Automatic engagement between the grid and consumers will be necessary to enable a clean yet stable electric grid, when integrating these variable and uncertain renewable energy sources. We present the WHISPER (Wireless Home Identification and Sensing Platform for Energy Reduction) system to address the energy and power demand triggered by human presence in homes. The presented system includes a maintenance-free and privacy-preserving human occupancy detection system wherein a local wireless network of battery-free environmental, acoustic energy, and image sensors are deployed to monitor homes, record empirical data for a range of monitored modalities, and transmit it to a base station. Several machine learning algorithms are implemented at the base station to infer human presence based on the received data, harnessing a hierarchical sensor fusion algorithm. Results from the prototype system demonstrate an accuracy in human presence detection in excess of 95%; ongoing commercialization efforts suggest approximately 99% accuracy. Using machine learning, WHISPER enables various applications based on its binary occupancy prediction, allowing situation-specific controls targeted at both personalized smart home and electric grid modernization opportunities.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Results of an Investigation of the 0.003-scale Space Shuttle External Tank MSFC Model 460 in the NASA/MSFC 14 x 14-inch Trisonic Wind Tunnel to Determine Static Pressure Distributions During Reentry (TA2F), Volume 1

Objectives of the test were to obtain static pressure distributions for the ET at reentry conditions. Basic configuration of the model was the MCR 0200 ET modified to include a rectangular crossbar at the aft ET/orbiter attach point. Mach numbers were 1.96, 3.48, and 4.96. Reynolds number per foot at these Mach numbers were 6.95 million, 6.42 million, and 4.95 million, respectively. Angle of attack range was -8 to 100 degrees and roll angle was 0 to 315 degrees. Occupancy hours were 104.

Ramsey, P. E.↗

Inverted Attic Bulkhead for HVAC Ductwork: Roseville, California (Fact Sheet)

K. Hovnanian Homes constructed a 2,253-ft single-story slab-on-grade ranch house for an occupied test house (new construction) in Roseville, California. One year of monitoring and analysis focused on the effectiveness of the space conditioning system at maintaining acceptable temperature and relative humidity levels in several rooms of the home, as well as room-to-room differences and the actual measured energy consumption by the space conditioning system. In this home, the air handler unit (AHU) and ducts were relocated to inside the thermal boundary. The AHU was relocated from the attic to a mechanical closet, and the ductwork was located inside an insulated and air-sealed bulkhead in the attic. To describe the performance and comfort in the home, the research team selected representative design days and extreme days from the annual data for analysis. To ensure that temperature differences were within reasonable occupant expectations, the team followed Air Conditioning Contractors of America guidance. At the end of the monitoring period, the occupant of the home had no comfort complaints in the home. Any variance between the modeled heating and cooling energy and the actual amounts used can be attributed to the variance in temperatures at the thermostat versus the modeled inputs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Reinforcement Learning to Enhance Optimal Operation of Resilient Community Energy Systems

This paper presents a novel model-free multi-agent Reinforcement Learning (RL) control method to enhance the resilience of community energy systems in island mode, which coordinates multiple objectives without the necessity of identifying system models that require expert knowledge. Specifically, a community-level coordinator agent is designed to allocate renewable energy resources among different buildings, and multiple building-level agents are developed to optimize load schedules based on limited energy resources and requirements of building loads and occupants’ comfort. In a two-day evaluation, our RL approach demonstrated a similar performance against MPC without requiring system models and formulation of optimization problems as required in MPC.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

Benzo[a]pyrene (BaP) metabolites predominant in human plasma following escalating oral micro-dosing with [ 14 C]-BaP

Benzo[a]pyrene (BaP) is formed by incomplete combustion of organic materials (petroleum, coal, tobacco, etc.). BaP is designated by the International Agency for Research on Cancer as a group 1 known human carcinogen; a classification supported by numerous studies in preclinical models and epidemiology studies of exposed populations. Risk assessment relies on toxicokinetic and cancer studies in rodents at doses 5–6 orders of magnitude greater than average human uptake. Using a dose–response design at environmentally relevant concentrations, this study follows uptake, metabolism, and elimination of [ 14 C]-BaP in human plasma by employing UPLC - accelerator mass spectrometry (UPLC-AMS). Volunteers were administered 25, 50, 100, and 250 ng (2.7–27 nCi) of [ 14 C]-BaP (with interceding minimum 3-week washout periods) with quantification of parent [ 14 C]-BaP and metabolites in plasma measured over 48 h. [ 14 C]-BaP median T max was 30 min with C max and area under the curve (AUC) approximating dose-dependency. Marked inter-individual variability in plasma pharmacokinetics following a 250 ng dose was seen with 7 volunteers as measured by the C max (8.99 ± 7.08 ng × mL -1 ) and AUC0-48hr (68.6 ± 64.0 fg × hr -1 × mL -1 ). Approximately 3–6% of the [ 14 C] recovered (AUC 0-48 hr ) was parent compound, demonstrating extensive metabolism following oral dosing. Metabolite profiles showed that, even at the earliest time-point (30 min), a substantial percentage of [ 14 C] in plasma was polar BaP metabolites. The best fit modeling approach identified non-compartmental apparent volume of distribution of BaP as significantly increasing as a function of dose (p = 0.004). Bay region tetrols and dihydrodiols predominated, suggesting not only was there extensive first pass metabolism but also potentially bioactivation. AMS enables the study of environmental carcinogens in humans with de minimus risk, allowing for important testing and validation of physiologically based pharmacokinetic models derived from animal data, risk assessment, and the interpretation of data from high-risk occupationally exposed populations.

59 BASIC BIOLOGICAL SCIENCES↗

220 Rn (Thoron) Geohazard in Room Air of Earthen Dwellings in Vietnam

Thoron’s ( 220 Rn) contribution to α -radiation exposure is usually considered negligible compared to that of 222 Rn (radon). Despite its short half-life of 55.6 seconds, thoron can be exhaled from porous surface layers of building materials into indoor air where people subsequently inhale radioisotopes, including metallic radioactive progeny. Bare surfaces of dry porous soil with relatively high 232 Th content can pose a thoron radiation hazard in indoor air. On northern Vietnam’s Dong Van karst plateau, the spatial distribution of thoron was determined in indoor air of traditional earthen and other types of dwellings using portable RAD7 and SARAD® RTM 2200 detectors. “Mud houses” are constructed with local compacted soil and typically do not have any floor or wall coverings (i.e., no plaster, wallpaper, or paint). Detailed measurements in a mud house revealed levels of thoron in room air averaging >500 Bq m -3 . The spatial distribution of α -radiation from thoron in indoor air at a distance of about 1 m from interior walls was fairly homogeneous and averaged ~200 Bq m -3 . Most concerning, from a human health perspective, were the high thoron concentrations of up to 884 Bq m -3 in sleeping areas near mud walls. The average annual thoron radiation dose to inhabitants of mud houses was estimated based on 13 hours of daily occupancy, including daily activities and sleeping. The estimated average thoron inhalation dose of 27.1 mSv a -1 during sleeping hours near mud surfaces accounts for nearly 75% of the total estimated radon and thoron inhalation dose of 37.4 mSv a -1 from indoor mud house air. Our conservative annual radiation dose estimates do not include subsequent radiation from inhaled metallic progeny of thoron. Our data demonstrate a significant human health risk from radiation exposure and a critical need for remediation in traditional northern Vietnamese mud house dwellings.

58 GEOSCIENCES↗