Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Nuclear science”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Development and experimental evaluation of an acoustic flow meter prototype for measuring air flow

Here, this study outlines the development and testing of a flow meter prototype specifically designed for use in nuclear reactor environments. The meter uses flow-induced vibration to measure flow rates and is designed for remote monitoring in harsh environments where radiation can damage electronics. The device generates a vibration signal produced by a feedback system when fluid flows out of an orifice and interacts with a downstream wedge. The frequency of the vibration signal corresponds directly to flow rate and velocity. The study investigates geometric parameters intrinsic to the prototype, such as orifice height, width, edge distance, and chamber length. Different configurations were also tested, including a bypass loop with variable cross-sections around the device. The investigation results reveal the impact of these geometric parameters on the vibration signal output, providing valuable insights for future design improvements and enhancing the effectiveness of flow metering systems used in nuclear reactor applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An in-situ movable calibration source for cryogenic particle detectors

A prototype device capable of moving a radioactive calibration source to multiple positions was operated at millikelvin temperatures using a modified commercial stepper motor. It was developed as an in-situ calibration strategy for cryogenic dark matter detectors. Data taken by scanning a calibration source across multiple radial positions of a prototype dark matter detector demonstrated its functionality. Construction, heat load, and operation of the device are discussed, as is the effect of the motor on the detector operation. A sample dataset taken over multiple positions of a SuperCDMS detector is presented as an example of the utility of such a device.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Status of the SABRE South experiment at the Stawell underground physics laboratory

The SABRE (Sodium iodide with Active Background REjection) experiments aim to detect an annual rate modulation from dark matter interactions in ultra-high purity NaI(Tl) crystals. The SABRE South experiment is located at the Stawell Underground Physics Laboratory (SUPL), Australia, and is the first deep underground laboratory in the Southern Hemisphere. SABRE South is designed to disentangle seasonal or site-related effects from the dark matter-like modulated signal first observed by DAMA/LIBRA in the Northern Hemisphere using an active veto and muon detection system. It is a partner to the SABRE North effort at the Laboratori Nazionali del Gran Sasso (LNGS). SABRE South is instrumented with ultra-high purity NaI(Tl) crystals immersed in a linear alkyl benzene (LAB) based liquid scintillator veto, further surrounded by passive steel and polyethylene shielding and a plastic scintillator muon veto. Significant work has been undertaken to understand the experimental backgrounds and performance of the crystals. The SABRE South experiment is under construction, and will be commissioned from late 2022 to early 2023. We will present the final design of SABRE South, the status of its construction, its expected background, and its sensitivity to a DAMA/LIBRA like modulation. We will also present recent quenching factor measurements of sodium nuclear recoils in NaI(Tl) crystals measured at the Heavy Ion Accelerator Facility, and a report on the status of SUPL.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

LISE$^{++}_{cute}$, the latest generation of the LISE ++ package, to simulate rare isotope production with fragment-separators

The LISE ++ software for fragment separator simulations has undergone a major update. The package, widely used at rare isotope beam facilities, can be used to predict intensities and purities of rare isotope beams and for planning and running of experiments using in-flight separators. It is especially useful for radioactive beam production as its results can be quickly compared to on-line data. The LISE ++ package has been ported to the Qt-framework in order to support modern compilers and computing methods. The benefits include 64-bit operation and LISE ++ availability on three different platforms: Windows, MacOS and Linux. In addition, the porting provides the ability to take advantage of future computational improvements. The updated package is named LISE$^{++}_{cute}$ to indicate a major step forward from the previous Borland-based versions. In addition to porting to the new platform, new main features and modifications have been added, mostly devoted to improving models and implementing other codes involved in rare isotope production at FRIB. Finally, a summary of modifications completed to improve the functionality of the code are discussed in this work, as well as future plans.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Reduction of ion backflow using a quadruple GEM detector with various gas mixtures

In gaseous tracking detectors with a large gaseous volume, like Time Projection Chambers (TPC), multiple layers of Gas Electron Multipliers (GEM) can be used to block positive ions from flowing back into the active volume, which is detrimental to the tracking performance. TPCs with multilayer GEM readout are used in the recently upgraded ALICE experiment, and in the upcoming sPHENIX experiment. In both cases, suppression of ion backflow (IBF) is important for achieving the desired detector performance. Here, we report on studies of effective gain, IBF, and energy resolution in quadruple GEM detectors, and on strategies for minimizing IBF by optimizing the operating voltages of the individual GEM layers and the potential differences between different layers. These studies are performed as baseline measurements intended to aid in the optimization of the operating conditions of the GEMs of the sPHENIX TPC.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A high-granularity calorimeter insert based on SiPM-on-tile technology at the future Electron-Ion Collider

Herein we present a design for a high-granularity calorimeter insert for future experiments at the Electron-Ion Collider (EIC). The sampling-calorimeter design uses scintillator tiles read out with silicon photomultipliers. It maximizes coverage close to the beampipe, while solving challenges arising from the beam-crossing angle and mechanical integration. It yields a compensated response that is linear over the energy range of interest for the EIC. Its energy resolution meets the requirements set in the EIC Yellow Report even with a basic reconstruction algorithm. Moreover, this detector will provide 5D shower data (position, energy, and time), which can be exploited with machine-learning techniques. This detector concept has the potential to unleash the power of imaging calorimetry at the EIC to enable measurements at extreme kinematics in electron–proton and electron–nucleus collisions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Generalized method for the optimization of pulse shape discrimination parameters

Organic scintillators exhibit fast timing, high detection efficiency for fast neutrons and pulse shape discrimination (PSD) capability. PSD is essential in mixed radiation fields, where different types of radiation need to be detected and discriminated. In neutron measurements for nuclear security and non proliferation effective PSD is crucial, because a weak neutron signature needs to be detected in the presence of a strong gamma-ray background. Here, the most commonly used deterministic PSD technique is charge integration (CI). This method requires the optimization of specific parameters to obtain the best gamma-neutron separation. These parameters depend on the scintillating material and light readout device and typically require a lengthy optimization process and a calibration reference measurement with a mixed source. In this paper, we propose a new method based on the scintillation fluorescence physics that enables to find the optimum PSD integration gates using only a gamma-ray emitter. We demonstrate our method using three organic scintillation detectors: deuterated trans-stilbene, small-molecule organic glass, and EJ-309. In all the investigated cases, our method allowed finding the optimum PSD CI parameters without the need of iterative optimization.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Systematic evaluation of fast neutron sensing with Cesium Hafnium Chloride

Cesium Hafnium Chloride (CHC) is a promising new scintillator for dual mode sensing of both neutrons and gamma-rays. The high chlorine content allows for both 35 Cl(n,p) 35 S and 35 Cl(n,α) 32 P reaction channels leading to reliable detection of fast neutrons. By utilizing pulse shape discrimination (PSD), these neutron interactions may be reliably separated from gamma-ray signals with a high figure-of-merit (FOM) after optimization of the PSD algorithm. Here, in this study, the PSD algorithm settings for CHC were systematically investigated using a bare 252 Cf and a lead shielded plutonium beryllium neutron source. It was found that the PSD algorithm settings affects both the FOM and the neutron detection efficiency, but a FOM as high as 4.5 for alpha particles was observed in one data processing scenario. Further, an intrinsic 5 parts per million alpha emitting contamination was observed in the sample, which we attribute to natural uranium.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

RPC background studies at CMS experiment

During Run2 the high instantaneous luminosity, up to 2.2 · 10 34 cm -2 s -1 , lead to a substantial hit rate in the Compact Muon Solenoid experiment’s muon chambers due to multiple background sources to physics processes sought for at LHC. In this article we will describe the analysis method devised to measure and identify the contributions to such background in the Resistive Plate Chambers. Thorough understanding of the background rates provides the base for the upgrade of the muon detectors for the High-Luminosity LHC.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Determination of energy-dependent neutron backgrounds using shadow bars

Understanding the neutron background is essential for determining the neutron yield from nuclear reactions. Here, the neutron backgrounds were determined for heavy-ion collision experiment using the shadow-bar method, where beams of 40,48 Ca at 56, 140 MeV/u impinged on targets of 58,64 Ni and 112,124 Sn. In the analysis presented here, brass shadow bars are placed in front of organic liquid scintillator neutron detectors to determine the energy-dependent neutron background fractions. The measurement of neutron spectra with and without shadow bars is important to determine the neutron background more accurately. The neutron background, along with its sources and systematic uncertainties, are explored with a focus on the impact of background models and their dependence on neutron energy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

TexAT detector upgrade for 14 O($α$, $p$) 17 F cross section measurement

A direct cross-section measurement of the 14 O($α$, $p$) 17 F reaction is important to understand the light curves of x-ray bursts. The measurement will be performed using the Texas Active Target TPC version 2 (TexAT_v2). The TexAT_v2 aims at measuring lower energy protons from the reaction than the original TexAT. Newly developed silicon and CsI(Tl) detector arrays are added at the left, right and bottom of a modified field cage to increase its detection efficiency. Furthermore, this paper describes the overall specifications and two commissioning experiments performed at Texas A&M University.

14O(α, p)17F↗

Structure characterization and steam oxidation performance of U 3 Si 2 with Zr alloying additions

Research and development of high uranium density fuels supports the on-going effort to enhance reactor technology, safety, performance, and economics. Among high uranium density fuels, U 3 Si 2 is a favored fuel candidate due to its higher uranium density and improved thermal conductivity when compared to traditional UO 2 . While U 3 Si 2 demonstrates an improved fuel economy, it suffers from rapid degradation when exposed to water at T > 300°C. In order for U 3 Si 2 to be implemented in water cooled reactors, the water reaction must be understood and mitigated. Reported here is the performance of Zr alloying additions to U 3 Si 2 exposed to high temperature steam oxidation environments. Here, the investigation shows that homogenization heat treatment contributes to a delayed onset of oxidation and an improved homogeneity throughout the arc-melt fabricated alloyed compositions. Of the pre- and post-annealed samples, the post-annealed 7 vol% Zr addition exhibited the highest onset temperature of oxidation. A preliminary computational investigation to complement the experimental analysis assesses the solubility of Zr in U 3 Si 2 and its incorporation in the crystal lattice.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Charge collection study with the ATLAS ITk prototype silicon strip sensors ATLAS17LS

The inner tracker of the ATLAS detector is scheduled to be replaced by a completely new silicon-based inner tracker (ITk) for the Phase-II of the CERN LHC (HL-LHC). The silicon strip detector covers the volume 40 < R < 100 cm in the radial and | z | < 300 cm in the longitudinal directions. The silicon sensors for the detector will be fabricated using the n + -on-p 6-inch wafer technology, for a total of 22,000 wafers. Here, intensive studies were carried out on the final prototype sensors ATLAS17LS fabricated by Hamamatsu Photonics (HPK). The charge collection properties were examined using penetrating 90 Sr β -rays and the ALIBAVA fast readout system for the miniature sensors of 1 cm × 1 cm in area. The samples were irradiated by protons in the 27 MeV Birmingham Cyclotron, the 70 MeV CYRIC at Tohoku University, and the 24 GeV CERN-PS, and by neutrons at Ljubljana TRIGA reactor for fluence values up to 2 × 10 15 n eq /cm 2 . The change in the charge collection with fluence was found to be similar to the previous prototype ATLAS12, and acceptable for the ITk. Sensors with two active thicknesses, 300 μ m (standard) and 240 μ m (thin), were compared and the difference in the charge collection was observed to be small for bias voltages up to 500 V. Some samples were also irradiated with gamma radiation up to 2 MGy, and the full depletion voltage was found to decrease with the dose. This was caused by the Compton electrons due to the 60 Co gamma radiation. To summarize, the design of the ATLAS17LS and technology for its fabrication have been verified for implementation in the ITk. We are in the stage of sensor pre-production with the first sensors already delivered in January of 2020.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Simulation studies for beam commissioning at FRIB Advanced Rare Isotope Separator

The Facility for Rare Isotope Beams (FRIB) includes a powerful superconducting driver accelerator and an Advanced Rare Isotope Separator (ARIS). The ARIS collects and purifies the rare isotope fragments of interest for experiments in nuclear physics, nuclear astrophysics, fundamental symmetries, etc. ARIS consists of a vertical pre-separator and downstream horizontal separator section (C-Bend). Each section can provide a high-resolution separation alternatively. The resolution reduction due to the emittance induced by momentum compression can be avoided by isotope separation in different dispersive planes. Beam commissioning of ARIS for the first experiments was completed and demonstrated particle identification of fragments. The beam tuning in ARIS largely relies on numerical simulations since the limited space for diagnostics. Here, we report the result of the beam trajectory correction, transverse matching, and beam-based misalignment studies at ARIS.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

2021 ATR Strategic Plan

Collaborative development of nuclear energy science and technology by three major sectors—academia, the commercial nuclear power industry, and the federal government—is key to meeting the challenges of nuclear energy. All three share a common need for experimental capabilities, whether for basic science investigations, applied research in nuclear fuels and materials, or validation of data. The Advanced Test Reactor (ATR) provides the unique irradiation capabilities to support the need.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗