Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “NEUTRON SPECTRA”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

The spectra of weakly magnetized neutron stars

The continuum spectrum of a rotating equatorial emitting region on the surface of an accreting neutron star is investigated within the Schwarzschild spacetime. It is found that the dominant general relativistic effect is the increase in apparent emission area from the neutron star surface due to gravitational light bending. For typical neutron star parameters, the apparent area of the accretion belt is remarkably independent of the viewing angle and, hence, the contribution for a boundary layer to the total X-ray luminosity is found to depend only weakly on the inclination angle of the binary system. For a blackbody spectrum in the local rest frame of the emitting surface, the distortion of the spectral shape by longitudinal and transverse Doppler shifts is minimal for neutron stars rotating at periods greater than about 2 ms. It is shown that the failure to detect a blackbody component from the weakly magnetized neutron star surface in some X-ray burst sources during their quiescent state may be related to the presence of temperature variations along the vertical extent of the boundary layer.

Fu, Albert↗

Computational characterization and experimental validation of the thermal neutron source for neutron capture therapy research at the University of Missouri

Parameter studies, design calculations and neutronic performance measurements have been completed for a new thermal neutron beamline constructed for neutron capture therapy cell and small-animal radiobiology studies at the University of Missouri Research Reactor. The beamline features the use of single-crystal silicon and bismuth sections for neutron filtering and for reduction of incident gamma radiation. The computational models used for the final beam design and performance evaluation are based on coupled discrete-ordinates and Monte Carlo techniques that permit detailed modeling of the neutron transmission properties of the filtering crystals with very few approximations. Validation protocols based on neutron activation spectrometry measurements and rigorous least-square adjustment techniques show that the beam produces a neutron spectrum that has the anticipated level of thermal neutron flux and a somewhat higher than expected, but radio-biologically insignificant, epithermal neutron flux component. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

Level Density Parameter: A Tool to Study the Particle Spectra

The compound nucleus {sup 76}Kr* is formed in the heavy-ion fusion reactions by an asymmetric entrance channel {sup 12}C+{sup 64}Zn and the symmetric entrance channel {sup 31}P+{sup 45}Sc at the excitation energy of 75 MeV and angular momentum of 39 eta. Neutron energy spectra of the asymmetric system ({sup 12}C+{sup 64}Zn) at different angles are well described by the statistical model predictions using the normal value of the level density parameter a = A/8 MeV{sup -1}. However, in the case of the symmetric system ({sup 31}P+{sup 45}Sc), the statistical model interpretation of the data requires the change in the value of a = A/10 MeV{sup -1}. The delayed evolution of the compound system in case of the symmetric {sup 31}P+{sup 45}Sc system may lead to the formation of a temperature equilibrated dinuclear complex, which may be responsible for the neutron emission at higher temperature, while the protons and alpha particles are evap orated after neutron emission when the system is sufficiently cooled down and the higher lambda-values do not contribute in the formation of the compound nucleus for the symmetric entrance channel in case of charged particle emission.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Proportional counter as neutron detector

A technique to separate out the dose, and lineal energy spectra of neutrons and charged particles is described. It is based on using two proportional counters, one with a wall, and the other with similar characteristics but wall made from a non-hydrogen containing material. Results of a calibration in a neutron field are also shown. c2001 Elsevier Science Ltd. All rights reserved.

NASA Center JSC↗

MONSTER: a TOF Spectrometer for β-delayed Neutron Spectroscopy

β-delayed neutron (DN) data, including emission probabilities, Pn, and energy spectrum, play an important role in our understanding of nuclear structure, nuclear astrophysics and nuclear technologies. A MOdular Neutron time-of-flight SpectromeTER (MONSTER) is being built for the measurement of the neutron energy spectra and branching ratios. The TOF spectrometer will consist of one hundred liquid scintillator cells covering a significant solid angle. The MONSTER design has been optimized by using Monte Carlo (MC) techniques. The response function of the MONSTER cell has been characterized with mono-energetic neutron beams and compared to dedicated MC simulations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

EUCLID Sensitivity Database

This report documents the EUCLID sensitivity database along with its several use-cases. EUCLID computed sensitivities for the following integral responses: Criticality of ICSBEP critical assemblies, LLNL pulsed-sphere neutron-leakage spectra, reaction rates in selected ICBSEP critical assemblies, delayed neutron factions of selected ICSBEP critical assemblies, reactivity coefficients in two ICSBEP critical assemblies, sub-critical assembly responses and Rossi-alpha of selected critical assemblies. It is described for each response what the reported observable constitutes, the method we used to obtain the sensitivities, and which integral experiments were studied. It is also documented briefly in what format these sensitivities are stored. These sensitivities were used for many aspects of the EUCLID project, like ML-supported large-scale nuclear-data validation, or optimization of integral experiments. But these sensitivities can also be applied for more established processes in the nuclear-data application field such as adjustment or assessing the upper sub-critical limit.

Delayed Neutron Fraction↗

Assessment of Multi-Step CADIS Parameter Sensitivity to Neutron Flux Spectrum in Shutdown Dose Rate Calculations

Shutdown dose rate (SDDR) analysis requires (a) a neutron transport calculation to estimate neutron flux fields, (b) an activation calculation to compute radionuclide inventories and associated photon sources, and (c) a photon transport calculation to estimate final dose rate. In some applications, accurate full-scale Monte Carlo (MC) SDDR simulations are needed for very large systems with massive amounts of shielding materials. For example, SDDR assessments are required throughout the biological shield (bio-shield) of the ITER experimental facility to evaluate the required waiting period after the shutdown of ITER and to identify the locations where human accessibility should be prohibited. The bio-shield is a large cylindrical concrete structure (30 m tall and 34 m in diameter) surrounding the very complex tokamak machine. Determining the effects on SDDR of important factors, such as the cross talk (interactions) between the different ports of ITER, is possible only through full-scale simulations that involve all the complex inner details of the ITER tokamak machine. These simulations are impractical because calculation of space- and energy-dependent neutron fluxes throughout the structural materials is needed to estimate the distribution of radioisotopes causing the SDDR. Determining a good importance function that can be used in biasing a neutron MC calculation for SDDR is complicated because it is difficult to explicitly express the SDDR response function, which depends on subsequent computational steps. The Multi-Step Consistent Adjoint Driven Importance Sampling (MS-CADIS) hybrid MC/deterministic method was developed to speed up the SDDR MC neutron transport calculation using an importance function that represents the neutron importance to the final SDDR. The MS-CADIS method uses the CADIS method, which has been Notice: This manuscript has been authored by UT-Battelle, LLC, under Contract No. DE-AC0500OR22725 with the U.S. Department of Energy. The United States Government retains and the publisher, by accepting the article for publication, acknowledges that the United States Government retains a non-exclusive, paid-up, irrevocable, world-wide license to publish or reproduce the published form of this manuscript, or allow others to do so, for the United States Government purposes. The Department of Energy will provide public access to these results of federally sponsored research in accordance with the DOE Public Access Plan (http://energy.gov/downloads/doe-public-access-plan). successfully used for more than a decade in radiation shielding applications to generate consistent source biasing and weight window (WW) variance reduction parameters to accelerate continuous-energy MC simulations. However, because MS-CADIS focuses on multi-step shielding calculations such as SDDR calculations, it develops an importance function for the initial radiation transport calculation (e.g., the neutron calculations in SDDR simulations) that represents the importance of particles to the final response of the overall simulation. To develop this importance function, the MS-CADIS method uses an adjoint calculation with a specific neutron adjoint source that represents the neutron's contribution to the final SDDR. Brute force calculation of the MS-CADIS neutron adjoint source requires a deterministic neutron transport calculation coupled with activation calculations in each element of the deterministic mesh. These calculations are needed to determine the MS-CADIS parameter for the neutron interactions that produce radioisotopes contributing to the SDDR. The MS-CADIS parameter is the microscopic cross section of the radioisotope-producing interaction, multiplied by the mass of this radioisotope existing at the end of the irradiation and decay scenario, and divided by the steady-state rate of the interaction. Because the activation calculations are performed for each radionuclide in each mesh element, implementation of the MS-CADIS method can be computationally expensive. However, these neutron transport and activation calculations are not needed if we assume that the radioisotopes are created due to single neutron interactions and their concentrations do not change as a result of burnup by neutron irradiation. The use of this approximation, which renders the MS-CADIS parameter independent of the neutron flux, seems reasonable in calculating the MS-CADIS importance function because this function is needed only to speed up the MC calculation, not to calculate the final SDDR. In this work, we investigate the validity of this approximation by investigating the behavior of the MS-CADIS parameter as a function of the neutron flux spectra in the Fusion Evaluated Nuclear Data Library (FENDL) Neutronics and Shielding Benchmark problem that contains representative isotopes and flux environments of fusion energy systems. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

Localization and spectral isolation of special nuclear material using stochastic image reconstruction

Here, in this work we present a technique for isolating the gamma-ray and neutron energy spectra from multiple radioactive sources localized in an image. Image reconstruction algorithms for radiation scatter cameras typically focus on improving image quality. However, with scatter cameras being developed for non-proliferation applications, there is a need for not only source localization but also source identification. This work outlines a modified stochastic origin ensembles algorithm that provides localized spectra for all pixels in the image. We demonstrated the technique by performing three experiments with a dual-particle imager that measured various gamma-ray and neutron sources simultaneously. We showed that we could isolate the peaks from 22 Na and 137 Cs and that the energy resolution is maintained in the isolated spectra. To evaluate the spectral isolation of neutrons, a 252 Cf source and a PuBe source were measured simultaneously and the reconstruction showed that the isolated PuBe spectrum had a higher average energy and a greater fraction of neutrons at higher energies than the 252 Cf. Finally, spectrum isolation was used for an experiment with weapons grade plutonium, 252 Cf, and AmBe. The resulting neutron and gamma-ray spectra showed the expected characteristics that could then be used to identify the sources.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measurement of the 238U neutron-capture cross section and gamma-emission spectra from 10 eV to 100 keV using the DANCE detector at LANSCE

A careful new measurement of the {sup 238}U(n,{gamma}) cross section from 10 eV to 100 keV has been made using the DANCE detector at LANSCE. DANCE is a 4{pi} calorimetric scintillator array consisting of 160 BaF{sub 2} crystals. Measurements were made on a 48 mg/cm{sup 2} depleted uranium target. The cross sections are in general good agreement with previous measurements. The gamma-ray emission spectra, as a function of gamma multiplicity, were also measured and compared to model calculations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Design and experimental tests of a novel neutron spin analyzer for wide angle spin echo spectrometers

This paper describes the design and experimental tests of a novel neutron spin analyzer optimized for wide angle spin echo spectrometers. The new design is based on nonremanent magnetic supermirrors, which are magnetized by vertical magnetic fields created by NdFeB high field permanent magnets. The solution presented here gives stable performance at moderate costs in contrast to designs invoking remanent supermirrors. In the experimental part of this paper we demonstrate that the new design performs well in terms of polarization, transmission, and that high quality neutron spin echo spectra can be measured.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Progress on Nuclear Data Covariances: AFCI-1.2 Covariance Library

Improved neutron cross section covariances were produced for 110 materials including 12 light nuclei (coolants and moderators), 78 structural materials and fission products, and 20 actinides. Improved covariances were organized into AFCI-1.2 covariance library in 33-energy groups, from 10{sup -5} eV to 19.6 MeV. BNL contributed improved covariance data for the following materials: {sup 23}Na and {sup 55}Mn where more detailed evaluation was done; improvements in major structural materials {sup 52}Cr, {sup 56}Fe and {sup 58}Ni; improved estimates for remaining structural materials and fission products; improved covariances for 14 minor actinides, and estimates of mubar covariances for {sup 23}Na and {sup 56}Fe. LANL contributed improved covariance data for {sup 235}U and {sup 239}Pu including prompt neutron fission spectra and completely new evaluation for {sup 240}Pu. New R-matrix evaluation for {sup 16}O including mubar covariances is under completion. BNL assembled the library and performed basic testing using improved procedures including inspection of uncertainty and correlation plots for each material. The AFCI-1.2 library was released to ANL and INL in August 2009.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

HZETRN: neutron and proton production in quasi-elastic scattering of GCR heavy-ions

The development of transport models for radiation shielding design and evaluation has provided a series of deterministic computer codes that describe galactic cosmic radiation (GCR), solar particle events, and experimental beams at particle accelerators. These codes continue to be modified to accommodate new theory and improvements to the particle interaction database (Cucinotta et al., 1994, NASA Technical Paper 3472, US Government Printing Office, Washington DC). The solution employed by the heavy-ion transport code HZETRN was derived with the assumption that nuclear fragments are emitted with the same velocity as the incident ion through velocity conserving nuclear interactions. This paper presents a version of the HZETRN transport code that provides a more realistic distribution of the energy of protons and neutrons emitted from GCR interactions in shields. This study shows that the expected GCR dose equivalent is lower than previously calculated for water shields that are less than 110 g cm-2 thick. Calculations of neutron energy spectra in low Earth orbit indicate substantial contributions from relativistic neutrons. c2001 Elsevier Science Ltd. All rights reseved.

NASA Center LaRC↗

New work on updating and extending the nuclear data standards

An International Atomic Energy Agency (IAEA) Data Development Project was initiated to provide a mechanism for allowing new experimental data and improvements in evaluation procedures to be incorporated into new evaluations of the standards. The work on this project is ongoing. In the past very long periods sometimes occurred between evaluations of the standards. Through the use of this Project, such long periods should not occur. Work on the cross section standards through this Project has included an update of the experimental data to be used in the cross section standards evaluations, a study of the uncertainties obtained in the international standards evaluation, and improvements in the smoothing procedure for capture cross sections. It was decided that this Project should have a broader range of activities than just the cross section standards and thus encompass standards related activities. The following are being investigated: improvements in the gold cross section at energies below where it is considered a standard and work on certain cross sections that are not as well known as the cross section standards but could be very useful as reference cross sections relative to which certain types of cross section measurements can be made. This work includes prompt gamma-ray production in fast neutron-induced reactions, and work on the {sup 252}Cf spontaneous fission neutron spectrum and the {sup 235}U thermal neutron fission spectrum. Most of the data investigated through this Project are used in dosimetry applications. (authors)

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Tomographic analysis of neutron and gamma pulse shape distributions from liquid scintillation detectors at Joint European Torus

The Joint European Torus (JET, Culham, UK) is the largest tokamak in the world devoted to nuclear fusion experiments of magnetic confined Deuterium (D)/Deuterium-Tritium (DT) plasmas. Neutrons produced in these plasmas are measured using various types of neutron detectors and spectrometers. Two of these instruments on JET make use of organic liquid scintillator detectors. The neutron emission profile monitor implements 19 liquid scintillation counters to detect the 2.45 MeV neutron emission from D plasmas. A new compact neutron spectrometer is operational at JET since 2010 to measure the neutron energy spectra from both D and DT plasmas. Liquid scintillation detectors are sensitive to both neutron and gamma radiation but give light responses of different decay time such that pulse shape discrimination techniques can be applied to identify the neutron contribution of interest from the data. The most common technique consists of integrating the radiation pulse shapes within different ranges of their rising and/or trailing edges. In this article, a step forward in this type of analysis is presented. The method applies a tomographic analysis of the 3-dimensional neutron and gamma pulse shape and pulse height distribution data obtained from liquid scintillation detectors such that n/γ discrimination can be improved to lower energies and additional information can be gained on neutron contributions to the gamma events and vice versa.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Derivation of at-birth neutron energy distribution of americium-beryllium source based on ISO8529 spectral data

In many practical applications, the accuracy of neutron transport calculations depends on an estimate of the energy distribution provided in the source definition. While the energy distribution of neutrons emitted by spontaneous fission sources is well-defined, the spectra of neutrons produced in (α,n) reactions in compound mixtures, such as americium-beryllium (AmBe), depend on the microstructural properties of the source material, which may vary. Although the energy of neutrons produced in nuclear reactions can be calculated from first principles, such computations require detailed knowledge of the key characteristics of the source material, which are often unknown. Here, this study focuses on deriving the at-birth neutron energy distribution for an AmBe source by applying reverse transport calculations to the externally measured high-precision spectrum recommended in the latest revision of the international standard. The derived at-birth spectrum was validated through indirect energy-sensitive neutron emission rate measurements of AmBe sources calibrated at national primary metrology institutions. The resulting at-birth neutron energy distribution serves as essential input data for radiation transport modeling, providing a validated spectrum for broader experimental and computational applications.

AmBe↗

Radiation characterization summary of the NETL beam port 1/5 free-field environment at the 128-inch core centerline adjacent location

The characterization of the neutron, prompt gamma-ray, and delayed gamma-ray radiation fields in the University of Texas at Austin Nuclear Engineering Teaching Laboratory (NETL) TRIGA reactor for the beam port (BP) 1/5 free-field environment at the 128-inch location adjacent to the core centerline has been accomplished. NETL is being explored as an auxiliary neutron test facility for the Sandia National Laboratories radiation effects sciences research and development campaigns. The NETL reactor is a TRIGA Mark-II pulse and steady-state, above-ground pool-type reactor. NETL is intended as a university research reactor typically used to perform irradiation experiments for students and customers, radioisotope production, as well as a training reactor. Initial criticality of the NETL TRIGA reactor was achieved on March 12, 1992, making it one of the newest test reactor facilities in the US. The neutron energy spectra, uncertainties, and covariance matrices are presented as well as a neutron fluence map of the experiment area of the cavity. For an unmoderated condition, the neutron fluence at the center of BP 1/5, at the adjacent core axial centerline, is about 8.2×10 12 n/cm 2 per MJ of reactor energy. About 67% of the neutron fluence is below 1 keV and 22% above 100 keV. The 1-MeV Damage-Equivalent Silicon (DES) fluence is roughly 1.6×10 12 n/cm 2 per MJ of reactor energy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Investigation of giant-dipole-resonance decay in the ({gamma}, n) reactions on {sup 52}Cr and {sup 51}V nuclei

The cross sections for the emission of fast neutrons ({epsilon}{sub n} > 3.7 MeV) in the reactions {sup 52}Cr({gamma}, n){sup 51}Cr and {sup 51}V({gamma}, n){sup 50}V at incident-photon energies in the range between 16.0 and 25.8 MeV were studied. The neutron energy spectra were measured at the bremsstrahlung-photon endpoint energies of 18.5, 21.0, and 23.0 MeV for the {sup 52}Cr and {sup 51}V nuclei and at the bremsstrahlung-photon energy of 25.5 MeV for the {sup 51}V nucleus. Special features of giant-dipole-resonance decay that are associated with the existence of a structure in photoneutron cross sections and spectra are discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗