Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Multiple Errors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Viscous-inviscid interaction and local grid refinement via truncation error injection

A methodology is presented which makes it possible to decouple a complex problem having multiple disparate length scales into problems of single length scale so that they can be solved more efficiently on a computer. The method is applied to a viscous transonic flow over an airfoil. It is found that accurate prediction of the flow over an airfoil can be obtained by solving the Euler equations on a relatively coarse global grid with viscous effects computed separately on a boundary-layer type grid and injected into the global grid solution as a combination of vorticity and trucation error.

Goble, Brian D.↗

Real-time quantum error correction beyond break-even

The ambition of harnessing the quantum for computation is at odds with the fundamental phenomenon of decoherence. The purpose of quantum error correction (QEC) is to counteract the natural tendency of a complex system to decohere. This cooperative process, which requires participation of multiple quantum and classical components, creates a special type of dissipation that removes the entropy caused by the errors faster than the rate at which these errors corrupt the stored quantum information. Previous experimental attempts to engineer such a process faced an excessive generation of errors that overwhelmed the error-correcting capability of the process itself. Whether it is practically possible to utilize QEC for extending quantum coherence thus remains an open question. We answer it by demonstrating a fully stabilized and error-corrected logical qubit whose quantum coherence is significantly longer than that of all the imperfect quantum components involved in the QEC process, beating the best of them with a coherence gain of G=2.27±0.07. Here we achieve this performance by combining innovations in several domains including the fabrication of superconducting quantum circuits and model-free reinforcement learning.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A study on the criticality safety for the direct disposal of used nuclear fuel in Japan: Application of burnup credit to the criticality safety evaluation for the disposal canister - 14049

Japan has recently started the technical development of the direct disposal of used nuclear fuel (UNF) to prepare various disposal options. Unlike the disposal of radioactive waste from UNF reprocessing, criticality safety is important here because of the presence of a certain amount of fissile nuclides in UNF. This paper provides an outline of the research to be addressed in this field and the relevant studies in Japan. It especially includes the first result of a criticality safety evaluation of a disposal canister model adopting burnup credit. In this evaluation, it was assumed that a steel disposal canister loaded with fuel assemblies was surrounded by a clay buffer material, and the fuel assemblies and the disposal canister were intact. Conditions representative of discharged pressurized-water reactor (PWR) fuel were applied in this study - initial U-235 enrichment of 4.5 wt% and burnup of 45 GWd/t. The isotopic composition of the burnt fuel was evaluated using SWAT3.1 code. In the depletion calculation, conservative parameters were applied within the typical PWR operation range. The effective neutron multiplication factor (k{sub eff}) was then calculated using a continuous-energy Monte Carlo code MVP-2.0, adopting the JENDL-4.0 nuclear data library. Uncertainty in k{sub eff} due to depletion calculation errors was evaluated using the correction factors of isotopic composition, which were obtained via multiple comparisons between the calculated and measured isotopic concentrations of irradiated fuels. In addition, the effects of axial burnup profile and horizontal burnup gradient on k{sub eff} were evaluated using the open burnup distribution database. The k{sub eff} including the uncertainties and conservatism was found to be below 0.95 for both actinide-only and actinide and fission product considerations when the fuel assemblies and the disposal canister were assumed to be intact. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Confronting Weather and Climate Models with Observational Data from Soil Moisture Networks over the United States

Four land surface models in uncoupled and coupled configurations are compared to observations of daily soil moisture from 19 networks in the conterminous United States to determine the viability of such comparisons and explore the characteristics of model and observational data. First, observations are analyzed for error characteristics and representation of spatial and temporal variability. Some networks have multiple stations within an area comparable to model grid boxes; for those it is found that aggregation of stations before calculation of statistics has little effect on estimates of variance, but soil moisture memory is sensitive to aggregation. Statistics for some networks stand out as unlike those of their neighbors, likely because of differences in instrumentation, calibration, and maintenance. Buried sensors appear to have less random error than near-field remote sensing techniques, and heat-dissipation sensors show less temporal variability than other types. Model soil moistures are evaluated using three metrics: standard deviation in time, temporal correlation (memory), and spatial correlation (length scale). Models do relatively well in capturing large-scale variability of metrics across climate regimes, but they poorly reproduce observed patterns at scales of hundreds of kilometers and smaller. Uncoupled land models do no better than coupled model configurations, nor do reanalyses outperform free-running models. Spatial decorrelation scales are found to be difficult to diagnose. Using data for model validation, calibration, or data assimilation from multiple soil moisture networks with different types of sensors and measurement techniques requires great caution. Finally, data from models and observations should be put on the same spatial and temporal scales before comparison.

54 ENVIRONMENTAL SCIENCES↗

Recalculation of the isotropic H functions

The isotropic H functions defined in radiative transfer theory by Chandrasekhar (1960) have been numerically recalculated for a larger number of single scattering albedo (w) values. The obtained H functions should be accurate to five decimal places at least. The H function values become highly nonlinear as w approaches 1, where calculations were performed with many more points than in Chandrasekhar (1960). A simple linear interpolation of Chandrasekhar's H function table could result in as much as 8% error in the H function values and 16% in the H(exp 2) values that appear in multiple scattering terms such as in Hapke (1981). On the other hand, Hapke's approximations (1981, 1993) give H values within 4.1% and 0.8% error, respectively.

Hiroi, Takahiro↗

Studies of x-ray localization and thickness dependence in atomic-scale elemental mapping by STEM energy-dispersive x-ray spectroscopy using single-frame scanning method

The delocalization of x-ray signals limits the spatial resolution in atomic-scale elemental mapping by scanning transmission electron microscopy (STEM) using energy-dispersive x-ray spectroscopy (EDS). In this study, using a SrTiO 3 [001] single crystal, we show that the x-ray localization to atomic columns is strongly dependent on crystal thickness, and a thin crystal is critical for improving the spatial resolution in atomic-scale EDS mapping. A single-frame scanning technique is used in this study instead of the multiple-frame technique to avoid peak broadening due to tracking error. The strong thickness dependence is realized by measuring the full width at half maxima (FWHM) as well as the peak-to-valley (P/V) ratio of the EDS profiles for Ti K and Sr K+L, obtained at several crystal thicknesses. A FWHM of about 0.16 nm and a P/V ratio of greater than 7.0 are obtained for Ti K for a crystal thickness of less than 20 nm. In conclusion, with increasing crystal thickness, the FWHM and P/V ratio increases and decreases, respectively, indicating the advantage of using a thin crystal for high-resolution EDS mapping.

36 MATERIALS SCIENCE↗

Dynamic motion trajectory control with nanoradian accuracy for multi-element X-ray optical systems via laser interferometry

The past decades have witnessed the development of new X-ray beam sources with brightness growing at a rate surpassing Moore’s law. Current and upcoming diffraction limited and fully coherent X-ray beam sources, including multi-bend achromat based synchrotron sources and high repetition rate X-ray free electron lasers, puts increasingly stringent requirements on stability and accuracy of X-ray optics systems. Parasitic motion errors at sub-micro radian scale in beam transport and beam conditioning optics can lead to significant loss of coherence and brightness delivered from source to experiment. To address this challenge, we incorporated optical metrology based on interferometric length and angle sensing and real-time correction as part of the X-ray optics motion control system. A prototype X-ray optics system was constructed following the optical layout of a tunable X-ray cavity. On-line interferometric metrology enabled dynamical feedback to a motion control system to track and compensate for motion errors. The system achieved sub-microradian scale performance, as multiple optical elements are synchronously and continuously adjusted. This first proof of principle measurement demonstrated both the potential and necessity of incorporating optical metrology as part of the motion control architecture for large scale X-ray optical systems such as monochromators, delay lines, and in particular, X-ray cavity systems to enable the next generation cavity-based X-ray free electron lasers.

47 OTHER INSTRUMENTATION↗

Flash radiography with 24 GeV/c protons

The accuracy of density measurements and position resolution in flash (40 ns) radiography of thick objects with 24 Gev/c protons is investigated. A global model fit to step wedge data is shown to give a good description spanning the periodic table. The parameters obtained from the step wedge data are used to predict transmission through the French Test Object (FTO), a test object of nested spheres, to a precision better than 1%. Multiple trials have been used to show that the systematic errors are less than 2%. Absolute agreement between the average radiographic measurements of the density and the known density is 1%. Spatial resolution has been measured to be 200 {mu}m at the center of the FTO. These data verify expectations of the benefits provided by high energy hadron radiography for thick objects.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Nuclear Science for the Manhattan Project and Comparison to Today’s ENDF Data

Nuclear physics advances in the United States and Britain from 1939 to 1945 are described. The Manhattan Project’s work led to an explosion in our knowledge of nuclear science. A conference in April 1943 at Los Alamos provided a simple formula used to compute critical masses and laid out the research program needed to determine the key nuclear constants. In short order, four university accelerators were disassembled and reassembled at Los Alamos, and methods were established to make measurements on extremely small samples owing to the initial lack of availability of enriched 235U and plutonium. I trace the program that measured fission cross sections, fission-emitted neutron multiplicities and their energy spectra, and transport cross sections, comparing the measurements with our best understanding today as embodied in the Evaluated Nuclear Data File ENDF/B-VIII.0. The large nuclear data uncertainties at the beginning of the project, which often exceeded 25% to 50%, were reduced by 1945 often to less than 5% to 10%. Uranium-235 and plutonium-239 fission cross-section assessments in the fast mega-electron-volt range were reduced following more accurate measurements, and the neutron multiplicity $\overline{v}$ increased. By a lucky coincidence of canceling errors, the initial critical mass estimates were close to the final estimated masses. Some images from historical documents from our Los Alamos archives are shown. Many of the original measurements from these early years have not previously been widely available. Through this work, these data have now been archived in the international experimental nuclear reaction data library (EXFOR) in a collaboration with the International Atomic Energy Agency and Brookhaven National Laboratory.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A New Methodology for Calculating The Energy Performance of Manufacturing Facilities

Total energy comparison (TEC), classic energy intensity (CEI), and linear regression models (LRM) are the three most common approaches used to track the energy performance of manufacturing facilities. TEC simply compares the total energy consumption from utility bills. TEC is rarely used because it does not consider the variation of any factors that may affect energy consumption. One step better, CEI considers the variation of production rates by using the ratio of annual total energy consumption over annual total production. However, CEI fundamentally assumes that energy consumption is zero if the production rate is zero. This is almost never true and can cause significant errors. Using linear regression models, LRM considers the impact of multiple variables and, therefore, most accurately tracks energy performance. Unfortunately, because of the lack of either required data or technical expertise, some facilities cannot create valid linear regression models. For these cases, CEI is the only option. Here, the goal of this article is to develop a new methodology, modified energy intensity (MEI), which is more accurate than CEI, but requires much less data and is easier to implement than LRM. Using the underlying principle of LRM, this article first outlines the mathematical derivation of the equations for MEI, then explains them from an engineering perspective. Finally, the implementation of MEI is discussed.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

POSSIBLE DETECTION OF AN EMISSION CYCLOTRON RESONANCE SCATTERING FEATURE FROM THE ACCRETION-POWERED PULSAR 4U 1626-67

We present analysis of 4U 1626-67, a 7.7 s pulsar in a low-mass X-ray binary system, observed with the hard X-ray detector of the Japanese X-ray satellite Suzaku in 2006 March for a net exposure of {approx}88 ks. The source was detected at an average 10-60 keV flux of {approx}4 Multiplication-Sign 10{sup -10} erg cm{sup -2} s{sup -1}. The phase-averaged spectrum is reproduced well by combining a negative and positive power-law times exponential cutoff (NPEX) model modified at {approx}37 keV by a cyclotron resonance scattering feature (CRSF). The phase-resolved analysis shows that the spectra at the bright phases are well fit by the NPEX with CRSF model. On the other hand, the spectrum in the dim phase lacks the NPEX high-energy cutoff component, and the CRSF can be reproduced by either an emission or an absorption profile. When fitting the dim phase spectrum with the NPEX plus Gaussian model, we find that the feature is better described in terms of an emission rather than an absorption profile. The statistical significance of this result, evaluated by means of an F test, is between 2.91 Multiplication-Sign 10{sup -3} and 1.53 Multiplication-Sign 10{sup -5}, taking into account the systematic errors in the background evaluation of HXD-PIN. We find that the emission profile is more feasible than the absorption one for comparing the physical parameters in other phases. Therefore, we have possibly detected an emission line at the cyclotron resonance energy in the dim phase.

79 ASTRONOMY AND ASTROPHYSICS↗

Red Dragon: a redshift-evolving Gaussian mixture model for galaxies

ABSTRACT Precision-era optical cluster cosmology calls for a precise definition of the red sequence (RS), consistent across redshift. To this end, we present the Red Dragon algorithm: an error-corrected multivariate Gaussian mixture model (GMM). Simultaneous use of multiple colours and smooth evolution of GMM parameters result in a continuous RS and blue cloud (BC) characterization across redshift, avoiding the discontinuities of red fraction inherent in swapping RS selection colours. Based on a mid-redshift spectroscopic sample of SDSS galaxies, an RS defined by Red Dragon selects quiescent galaxies (low specific star formation rate) with a balanced accuracy of over $90{{\ \rm per\ cent}}$. This approach to galaxy population assignment gives more natural separations between RS and BC galaxies than hard cuts in colour–magnitude or colour–colour spaces. The Red Dragon algorithm is publicly available at bitbucket.org/wkblack/red-dragon-gamma/.

79 ASTRONOMY AND ASTROPHYSICS↗

Lanczos algorithm for lattice QCD matrix elements

Recent work [M. L. Wagman, Lanczos, the transfer matrix, and the signal-to-noise problem, .] found that an analysis formalism based on the Lanczos algorithm allows energy levels to be extracted from Euclidean correlation functions with faster ground-state convergence than effective masses, convergent estimators for multiple states from a single correlator, and two-sided error bounds. After filtering out spurious eigenvalues and using outlier-robust estimators within a nested bootstrap framework, Lanczos estimators behave more like multistate fit results than effective masses—but without involving statistical fitting. We extend this formalism to the determination of matrix elements from three-point correlation functions and provide a physical picture of “spurious-state filtering” involving restriction to a Hermitian subspace. We demonstrate similar advantages for matrix elements as for spectroscopy through example applications to noiseless mock-data and (bare) forward matrix elements of the strange scalar current between both ground and excited states with the quantum numbers of the nucleon.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Neumann Series Based Voltage Sensitivity Analysis for Three Phase Distribution System

In this letter, a simplified voltage sensitivity analysis technique that can provide accurate estimates of voltage change across the network for a given change in bus power injections in a three-phase unbalanced distribution network is proposed. This technique is derived from the first-order approximation of the Neumann series, which allows maintaining the accuracy of the solution while the computational effort is reduced. Here, the proposed technique is tested on a 559-bus unbalanced distribution system with multiple distributed generation resources. The results show that the average error in the voltage estimates with the proposed method is not more than 0.3% with the execution time of similar order relative to the state-of-the-art sensitivity analysis methods.

42 ENGINEERING↗

BrachyView, a novel in-body imaging system for HDR prostate brachytherapy: Experimental evaluation

Purpose: This paper presents initial experimental results from a prototype of high dose rate (HDR) BrachyView, a novel in-body source tracking system for HDR brachytherapy based on a multipinhole tungsten collimator and a high resolution pixellated silicon detector array. The probe and its associated position estimation algorithms are validated and a comprehensive evaluation of the accuracy of its position estimation capabilities is presented. Methods: The HDR brachytherapy source is moved through a sequence of positions in a prostate phantom, for various displacements in x, y, and z. For each position, multiple image acquisitions are performed, and source positions are reconstructed. Error estimates in each dimension are calculated at each source position and combined to calculate overall positioning errors. Gafchromic film is used to validate the accuracy of source placement within the phantom. Results: More than 90% of evaluated source positions were estimated with an error of less than one millimeter, with the worst-case error being 1.3 mm. Experimental results were in close agreement with previously published Monte Carlo simulation results. Conclusions: The prototype of HDR BrachyView demonstrates a satisfactory level of accuracy in its source position estimation, and additional improvements are achievable with further refinement of HDR BrachyView’s image processing algorithms.

60 APPLIED LIFE SCIENCES↗

TH-EF-BRA-08: A Novel Technique for Estimating Volumetric Cine MRI (VC-MRI) From Multi-Slice Sparsely Sampled Cine Images Using Motion Modeling and Free Form Deformation

Purpose: To develop a technique to estimate on-board VC-MRI using multi-slice sparsely-sampled cine images, patient prior 4D-MRI, motion-modeling and free-form deformation for real-time 3D target verification of lung radiotherapy. Methods: A previous method has been developed to generate on-board VC-MRI by deforming prior MRI images based on a motion model(MM) extracted from prior 4D-MRI and a single-slice on-board 2D-cine image. In this study, free-form deformation(FD) was introduced to correct for errors in the MM when large anatomical changes exist. Multiple-slice sparsely-sampled on-board 2D-cine images located within the target are used to improve both the estimation accuracy and temporal resolution of VC-MRI. The on-board 2D-cine MRIs are acquired at 20–30frames/s by sampling only 10% of the k-space on Cartesian grid, with 85% of that taken at the central k-space. The method was evaluated using XCAT(computerized patient model) simulation of lung cancer patients with various anatomical and respirational changes from prior 4D-MRI to onboard volume. The accuracy was evaluated using Volume-Percent-Difference(VPD) and Center-of-Mass-Shift(COMS) of the estimated tumor volume. Effects of region-of-interest(ROI) selection, 2D-cine slice orientation, slice number and slice location on the estimation accuracy were evaluated. Results: VCMRI estimated using 10 sparsely-sampled sagittal 2D-cine MRIs achieved VPD/COMS of 9.07±3.54%/0.45±0.53mm among all scenarios based on estimation with ROI-MM-ROI-FD. The FD optimization improved estimation significantly for scenarios with anatomical changes. Using ROI-FD achieved better estimation than global-FD. Changing the multi-slice orientation to axial, coronal, and axial/sagittal orthogonal reduced the accuracy of VCMRI to VPD/COMS of 19.47±15.74%/1.57±2.54mm, 20.70±9.97%/2.34±0.92mm, and 16.02±13.79%/0.60±0.82mm, respectively. Reducing the number of cines to 8 enhanced temporal resolution of VC-MRI by 25% while maintaining the estimation accuracy. Estimation using slices sampled uniformly through the tumor achieved better accuracy than slices sampled non-uniformly. Conclusions: Preliminary studies showed that it is feasible to generate VC-MRI from multi-slice sparsely-sampled 2D-cine images for real-time 3D-target verification. This work was supported by the National Institutes of Health under Grant No. R01-CA184173 and a research grant from Varian Medical Systems.

60 APPLIED LIFE SCIENCES↗

FPChecker

CUDA is the programming model used to program NVIDIA GPUs, which are widely used in DOE supercomputers. FPChecker allows programmers to detect and fix hidden exceptions in the floating-point computations that CUDA executes. When a floating-point exception occurs (e.g., division by zero), GPUs cannot catch these errors. FPChecker intercepts each floating-point operations (addition, subtraction, multiplication and division) and reports to users where exceptions occur (file and line of code).

Laguna Peralta, Ignacio↗

Ramping and Uncertainty Prediction Tool - Analysis and Visualization of Wind Generation Impact on Electrical Grid

RUT software is designed for use by the Balancing Authorities to predict and display additional requirements caused by the variability and uncertainty in load and generation. The prediction is made for the next operating hours as well as for the next day. The tool predicts possible deficiencies in generation capability and ramping capability. This deficiency of balancing resources can cause serious risks to power system stability and also impact real-time market energy prices. The tool dynamically and adaptively correlates changing system conditions with the additional balancing needs triggered by the interplay between forecasted and actual load and output of variable resources. The assessment is performed using a specially developed probabilistic algorithm incorporating multiple sources of uncertainty including wind, solar and load forecast errors. The tool evaluates required generation for a worst case scenario, with a user-specified confidence level.

Etingov, Pavel↗