Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Monte Carlo method.”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

SU-F-J-201: Validation Study of Proton Radiography Against CT Data for Quantitative Imaging of Anatomical Changes in Head and Neck Patients

Purpose: In clinical pencil-beam-scanned (PBS) proton therapy, the advantage of the characteristic sharp dose fall-off after the Bragg Peak (BP) becomes a disadvantage if the BP positions of a plan’s constituent pencil beams are shifted, eg.due to anatomical changes. Thus, for fractionated PBS proton therapy, accurate knowledge of the water equivalent path length (WEPL) of the traversed anatomy is critical. In this work we investigate the feasibility of using 2D proton range maps (proton radiography, PR) with the active-scanning gantry at PSI. Methods: We simulated our approach using Monte Carlo methods (MC) to simulate proton beam interactions in patients using clinical imaging data. We selected six head and neck cases having significant anatomical changes detected in per-treatment CTs.PRs (two at 0°/90°) were generated from MC simulations of low-dose pencil beams at 230MeV. Each beam’s residual depth-dose was propagated through the patient geometry (from CT) and detected on exiting the patient anatomy in an ideal depth-resolved detector (eg. range telescope). Firstly, to validate the technique, proton radiographs were compared to the ground truth, which was the WEPL from ray-tracing in the patient CT at the pencil beam location. Secondly, WEPL difference maps (per-treatment – planning imaging timepoints) were then generated to locate the anatomical changes, both in the CT (ground truth) and in the PRs. Binomial classification was performed to evaluate the efficacy of the technique relative to CT. Results: Over the projections simulated over all six patients, 70%, 79% and 95% of the grid points agreed with the ground truth proton range to within ±0.5%, ±1%, and ±3% respectively. The sensitivity, specificity, precision and accuracy were high (mean±1σ, 83±8%, 87±13%, 95±10%, 83±7% respectively). Conclusion: We show that proton-based radiographic images can accurately monitor patient positioning and in vivo range verification, while providing equivalent WEPL information to a CT scan, with the advantage of a much lower imaging dose.

60 APPLIED LIFE SCIENCES↗

SU-E-T-270: Diffusion Synthetic Acceleration for Linear Boltzmann Transport Equation

Purpose: Linear Boltzmann transport equation (LBTE) is as accurate as the Monte Carlo method (MC) for dose calculation in photon/particle therapy (LBTE is a deterministic and Eulerian formulation and MC is a statistical and Lagrangian description). An advantage of LBTE is that numerous acceleration techniques can be utilized for acceleration. This work is to explore the acceleration of LBTE via diffusion synthetic acceleration (DSA). Methods: For simplicity, two-dimensional, steady-state, and within-group LBTE is considered with two angular dimensions and two spatial dimensions. The discrete ordinate method is developed for solving this integro-differential equation. The angular variables are discretized using a level-symmetric quadrature set on the unit sphere. The spatial variables are discretized on the structured grid based on the diamond scheme. The source-iteration method (SI) is used to solve the discretized system.Since SI is slow in optically thick and highly scattering regime. DSA is developed to accelerate SI. The motivation for DSA is that diffusion equation (DE) is a good approximation of LBTE in the above regime. However, DE is much cheaper than LBTE computationally since DE only involves spatial variables. Thus, in each DSA iteration, DSA adds to the SI step a computationally-negligible DE step, i.e., to first solve DE with the SI residual as source term, and then compensate the SI solution with DE solution. Results: DSA was benchmarked and compared with SI. The difference between two methods was within 0.12% which verifies the accuracy of DSA, while DSA demonstrated the great advantage in speed, e.g., the reduction of iteration number to 6% and 4% respectively for cases with 100 and 1,000 scattering-absorption ratio that commonly occur in clinical dose calculation. Conclusion: DSA has been developed as one of many possible means for accelerating the numerical solver of LBTE for dose calculation. The authors were partially supported by the NSFC (#11405105), the 973 Program (#2015CB856000) and the Shanghai Pujiang Talent Program (#14PJ1404500)

60 APPLIED LIFE SCIENCES↗

Detector density and small field dosimetry: Integral versus point dose measurement schemes

Purpose: TheAlfonso et al. [Med. Phys.35, 5179–5186 (2008)] formalism for small field dosimetry proposes a set of correction factors (k{sub Q{sub c{sub l{sub i{sub n,Q{sub m{sub s{sub r}{sup f{sub c}{sub l}{sub i}{sub n},f{sub m}{sub s}{sub r}}}}}}}}}) which account for differences between the detector response in nonstandard (clinical) and machine-specific-reference fields. In this study, the Monte Carlo method was used to investigate the viability of such small field correction factors for four different detectors irradiated under a variety of conditions. Because k{sub Q{sub c{sub l{sub i{sub n,Q{sub m{sub s{sub r}{sup f{sub c}{sub l}{sub i}{sub n},f{sub m}{sub s}{sub r}}}}}}}}} values for single detector position measurements are influenced by several factors, a new theoretical formalism for integrated-detector-position [dose area product (DAP)] measurements is also presented and was tested using Monte Carlo simulations. Methods: A BEAMnrc linac model was built and validated for a Varian Clinac iX accelerator. Using the egs++ geometry package, detailed virtual models were built for four different detectors: a PTW 60012 unshielded diode, a PTW 60003 Diamond detector, a PTW 31006 PinPoint (ionization chamber), and a PTW 31018 MicroLion (liquid-filled ionization chamber). The egs-chamber code was used to investigate the variation ofk{sub Q{sub c{sub l{sub i{sub n,Q{sub m{sub s{sub r}{sup f{sub c}{sub l}{sub i}{sub n},f{sub m}{sub s}{sub r}}}}}}}}} with detector type, detector construction, field size, off-axis position, and the azimuthal angle between the detector and beam axis. Simulations were also used to consider the DAP obtained by each detector: virtual detectors and water voxels were scanned through high resolution grids of positions extending far beyond the boundaries of the fields under consideration. Results: For each detector, the correction factor (k{sub Q{sub c{sub l{sub i{sub n,Q{sub m{sub s{sub r}{sup f{sub c}{sub l}{sub i}{sub n},f{sub m}{sub s}{sub r}}}}}}}}}) was shown to depend strongly on detector off-axis position and detector azimuthal angle in addition to field size. In line with previous studies, substantial interdetector variation was also observed. However, it was demonstrated that by considering DAPs rather than single-detector-position dose measurements the high level of interdetector variation could be eliminated. Under small field conditions, mass density was found to be the principal determinant of water equivalence. Additionally, the mass densities of components outside the sensitive volumes were found to influence the detector response. Conclusions: k{sub Q{sub c{sub l{sub i{sub n,Q{sub m{sub s{sub r}{sup f{sub c}{sub l}{sub i}{sub n},f{sub m}{sub s}{sub r}}}}}}}}} values for existing detector designs depend on a host of variables and their calculation typically relies on the use of time-intensive Monte Carlo methods. Future moves toward density-compensated detector designs or DAP based protocols may simplify the methodology of small field dosimetry.

07 ISOTOPE AND RADIATION SOURCES↗

A Monte Carlo study of photochemical model uncertainties affecting the calculation of subsonic perturbations in the upper troposphere

Monte Carlo methods are frequently applied to the evaluation of uncertainties in models with multiple inputs that themselves have associated imprecisions. In the case of photochemical models used to evaluate changes in O3 or OH, inputs analyzed include rate coefficients measured in the laboratory, and chemical and physical constituents measured in the atmosphere. The Monte Carlo method was used with the 1-dimensional GSFC tropospheric photochemical model to examine uncertainty propagation to calculation of NO(x) and the major oxidants (O3, OH) in the upper troposphere. In all cases chemical kinetics inputs are varied and the NO(x) perturbation of a subsonic fleet is simulated. A series of model runs is used to explore sensitivities of model-computed parameters to other parameters: heterogeneous processes, the uncertainty in upper tropospheric H2O vapor measurements, aircraft emissions at different latitudes.

Thompson, Anne M.↗

Investigating the crust of neutron stars with neural-network quantum states

An accurate description of low-density nuclear matter is crucial for explaining the physics of neutron star crusts. In the density range between approximately 0.01 fm −3 and 0.1 fm −3 , matter transitions from neutron-rich nuclei to various higher-density pasta shapes, before ultimately reaching a uniform liquid. In this work, we introduce a variational Monte Carlo method based on a neural Pfaffian-Jastrow quantum state, which allows us to model the transition from the liquid phase to neutron-rich nuclei microscopically. At low densities, nuclear clusters dynamically emerge from the microscopic interactions among protons and neutrons, which we model based on pionless effective field theory. Our variational Monte Carlo approach represents a significant improvement over the state-of-the-art auxiliary-field diffusion Monte Carlo method, which is severely hindered by the fermion-sign problem in this low-density regime and cannot capture the onset of clusters. In addition to computing the energy per particle of symmetric nuclear matter and pure neutron matter, we analyze an intermediate isospin-asymmetry configuration to elucidate the formation of nuclear clusters. We also provide evidence that the presence of such nuclear clusters influences the amount of protons in the crust compared to protons in beta-equilibrated, neutrino-transparent matter.

Nuclear astrophysics↗

Three-dimensional radiative exchange factors for nongray, nondiffuse surfaces

A computer program using a variation of the Monte Carlo method was developed to predict radiative exchange factors in three-dimensional configurations with curved surfaces. The model allows for arbitrary emission, absorption, and reflection characteristics and for radiation exchange between surfaces as well as external irradiation through openings. It was shown that exchange factors can be determined efficiently by using the normal Monte Carlo method for closed configurations and/or high surface emissivities, while energy partitioning is vastly superior in the case of open configurations and/or low surface emissivities. Comparison with some experiments performed on the Space Shuttle heat rejection system demonstrates the model's accuracy as well as its superiority over a simplified diffuse-surface analysis, which requires similar amounts of computer time.

Modest, M. F.↗

Novel extrapolation method in the Monte Carlo shell model

We propose an extrapolation method utilizing energy variance in the Monte Carlo shell model to estimate the energy eigenvalue and observables accurately. We derive a formula for the energy variance with deformed Slater determinants, which enables us to calculate the energy variance efficiently. The feasibility of the method is demonstrated for the full pf-shell calculation of {sup 56}Ni, and the applicability of the method to a system beyond the current limit of exact diagonalization is shown for the pf+g{sub 9/2}-shell calculation of {sup 64}Ge.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Diffusion of self-point defects in body-centered cubic iron crystal containing dislocations

The energetic, crystallographic, and diffusion characteristics of self-point defects (SPDs) (vacancies and self-interstitial atoms (SIAs)) in body-centered cubic (bcc) iron crystal in the absence of stress fields have been obtained by the molecular statics and molecular dynamics methods. The effect of elastic stress fields of dislocations on the characteristics of SPDs (elastic dipoles) has been calculated by the methods of the anisotropic linear theory of elasticity. The SPD diffusion in the elastic fields of edge and screw dislocations (with Burgers vectors 1/2 <111> and <100>) at 293 K has been studied by the kinetic Monte Carlo method. The values of the SPD sink strength of dislocations of different types are obtained. Dislocations are more effective sinks for SIAs than for vacancies. The difference in the sink strengths for SIAs and vacancies in the case of edge dislocations is larger than the screw dislocations.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Emulators for Scarce and Noisy Data: Application to Auxiliary-Field Diffusion Monte Carlo for Neutron Matter

Understanding the equation of state (EOS) of pure neutron matter is necessary for interpreting multimessenger observations of neutron stars. Reliable data analyses of these observations require well-quantified uncertainties for the EOS input, ideally propagating uncertainties from nuclear interactions directly to the EOS. This, however, requires calculations of the EOS for a prohibitively larger number of nuclear Hamiltonians, solving the nuclear many-body problem for each one. Quantum Monte Carlo methods, such as auxiliary-field diffusion Monte Carlo (AFDMC), provide precise and accurate results for the neutron matter EOS, but they are very computationally expensive, making them unsuitable for the fast evaluations necessary for uncertainty propagation. Here, we employ parametric matrix models to develop fast emulators for AFDMC calculations of neutron matter and use them to directly propagate uncertainties of coupling constants in the Hamiltonian to the EOS. As these uncertainties include estimates of the effective field theory truncation uncertainty, this approach provides robust uncertainty estimates for use in astrophysical data analyses. In conclusion, this Letter will enable novel applications such as using astrophysical observations to put constraints on coupling constants for nuclear interactions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Solution of the Burnett equations for hypersonic flows near the continuum limit

The INCA code, a three-dimensional Navier-Stokes code for analysis of hypersonic flowfields, was modified to analyze the lower reaches of the continuum transition regime, where the Navier-Stokes equations become inaccurate and Monte Carlo methods become too computationally expensive. The two-dimensional Burnett equations and the three-dimensional rotational energy transport equation were added to the code and one- and two-dimensional calculations were performed. For the structure of normal shock waves, the Burnett equations give consistently better results than Navier-Stokes equations and compare reasonably well with Monte Carlo methods. For two-dimensional flow of Nitrogen past a circular cylinder the Burnett equations predict the total drag reasonably well. Care must be taken, however, not to exceed the range of validity of the Burnett equations.

Imlay, Scott T.↗

Floating Block Method for Quantum Monte Carlo Simulations

Quantum Monte Carlo simulations are powerful and versatile tools for the quantum many-body problem. In addition to the usual calculations of energies and eigenstate observables, quantum Monte Carlo simulations can in principle be used to build fast and accurate many-body emulators using eigenvector continuation or design time-dependent Hamiltonians for adiabatic quantum computing. Furthermore, these new applications require something that is missing from the published literature, an efficient quantum Monte Carlo scheme for computing the inner product of ground state eigenvectors corresponding to different Hamiltonians. In this work, we introduce an algorithm called the floating block method, which solves the problem by performing Euclidean time evolution with two different Hamiltonians and interleaving the corresponding time blocks. We use the floating block method and nuclear lattice simulations to build eigenvector continuation emulators for energies of 4 He, 8 Be, 12 C, and 16 O nuclei over a range of local and nonlocal interaction couplings. From the emulator data, we identify the quantum phase transition line from a Bose gas of alpha particles to a nuclear liquid.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Transport of energetic electrons in a fully ionized hydrogen plasma

A Monte Carlo method for calculating energetic electron transport in a plasma is presented. The energy loss and angular deflection due to Coulomb collisions as a function of travel distance and energy are derived for energetic electrons in a fully ionized plasma with a uniform magnetic field. Formulas which include the effect of nonuniform B fields on the angular deflection are derived. The Monte Carlo method is applied to the thick-target beam model in which the energetic electrons are injected vertically downward.

Bai, T.↗

Poster - 15: Air kerma rate measurements using a cylindrical free-air ionization chamber on the 05B1-1 beamline at the Canadian Light Source

Purpose: The BioMedical Imaging and Therapy (BMIT) beamlines at the Canadian Light Source offer the opportunity for investigating novel imaging and therapy applications of synchrotron radiation. A necessary component in advancing this research, and in progressing toward clinical applications, is the availability of accurate dosimetry that is traceable to a standards institution. However, dosimetry in this setting is challenging. These beams are typically small, non-uniform, and highly intense. This work describes air kerma rate measurements on a BMIT beamline using a free-air ionization chamber (FAC). Methods: The measurements were taken at the 05B1-1 beamline (∼8 – 100 keV) for several beam qualities with mean energies between 20.0 and 84.0 keV. The Victoreen Model 480 cylindrical FAC, with a specially fabricated 0.52 mm diameter aperture, was used to measure air kerma rates. The required correction factors were determined using a variety of methods: tabulated data, measurements, theoretical calculations and Monte Carlo simulations (EGSnrc user code egs-fac). Results: The experimental air kerma rates measured between 0.270 ± 13.6% and 312 ± 2.7% Gy/min. At lower energies (low filtration), the most impactful correction factors were those for ion recombination and for x-ray attenuation. Conclusions: These measurements marked the first absolute dosimetry performed at the BMIT beamlines. The experimental and Monte Carlo methods developed will allow air kerma rates to be measured under other experimental conditions, provide a benchmark to which other dosimeters will be compared, and provide a reference for imaging and therapy research programs on this beamline.

60 APPLIED LIFE SCIENCES↗

Stochastic, real-space, imaginary-time evaluation of third-order Feynman–Goldstone diagrams

A new, alternative set of interpretation rules of Feynman–Goldstone diagrams for many-body perturbation theory is proposed, which translates diagrams into algebraic expressions suitable for direct Monte Carlo integrations. A vertex of a diagram is associated with a Coulomb interaction (rather than a two-electron integral) and an edge with the trace of a Green's function in real space and imaginary time. With these, 12 diagrams of third-order many-body perturbation (MP3) theory are converted into 20-dimensional integrals, which are then evaluated by a Monte Carlo method. It uses redundant walkers for convergence acceleration and a weight function for importance sampling in conjunction with the Metropolis algorithm. The resulting Monte Carlo MP3 method has low-rank polynomial size dependence of the operation cost, a negligible memory cost, and a naturally parallel computational kernel, while reproducing the correct correlation energies of small molecules within a few mE{sub h} after 10{sup 6} Monte Carlo steps.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Electromagnetic and neutral-weak response functions of 4 He and 12 C

A major goal of nuclear theory is to understand the strong interaction in nuclei as it manifests itself in terms of two- and many-body forces among the nuclear constituents, the protons and neutrons, and the interactions of these constituents with external electroweak probes via one- and many-body currents. The objective of the present work is to calculate the quasielastic electroweak response functions in light nuclei within the realistic dynamical framework outlined above. These response functions determine the inclusive cross section as function of the lepton momentum and energy transfers. Their ab initio calculation is a very challenging quantum many-body problem, since it requires summation over the entire excitation spectrum of the nucleus and inclusion in the electroweak currents of one- and many-body terms. Green's functions Monte Carlo methods allow one to circumvent both difficulties by computing the response in imaginary time (the so-called Euclidean response) and hence summing implicitly over the bound and continuum states of the nucleus, and by implementing specific algorithms designed to deal with the complicated spin-isospin structure of nuclear many-body operators. Theoretical predictions for 4 He and 12 C, confirmed by experiment in the electromagnetic case, show that two-body currents generate excess transverse strength from threshold to the quasielastic to the dip region and beyond. In conclusion, these results challenge the conventional picture of quasielastic inclusive scattering as being largely dominated by single-nucleon knockout processes.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Preparatory Verification of a New Monte Carlo Code cosRMC based on VERA Core Physics Benchmark

To promote nuclear power plant system design and simulation software self-reliance development, DOE of China approved a R and D key project to develop an integrated engine for pressurized water reactor core and system design and analysis, referred as COSINE hereafter. The scope of this code package includes reactor physics, thermal hydraulics, safety analysis, severe accidents, probability safety assessment and etc. Many universities, research institutes and nuclear related corporations in China are involved in the code development, among which the State Nuclear Power Software Development Center (SNPSDC) plays the leading role. With the requirement of accurate three-dimensional modeling of the advanced, special or new complex core in reactor neutronics and shielding analysis, Monte Carlo method is becoming a more powerful tool for reactor analysis. Thus, a new Monte Carlo transport code named cosRMC (abbreviation for COSINE Reactor Monte Carlo) has been developed jointly by SNPSDC and Department of Engineering Physics, Tsinghua University, the main developer of RMC code. The cosRMC now has many functions as criticality calculation, fixed-source calculation, burnup calculation, and etc. Some techniques for geometry treatment, new burnup algorithm, source convergence acceleration, massive tally and parallel calculation have been implemented in cosRMC to improve the efficiency. In order to ensure its reliability, several types of V and V work have been and are being carried out for cosRMC. In this paper, some preparatory verification results based on VERA Core Physics Benchmark are presented. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Monte Carlo study of a model of diffusion-controlled reactions

The Monte Carlo method is used to perform averages over sink configurations in the present study of diffusion-controlled reactions occurring between solute particles and immobile spherical sinks. In order to determine the average steady state solute concentration profile in a locally perturbed solution for sink volume fractions phi of less than 0.3, the diffusion equation in the monopolar plus dipolar approximation of diffusive couplings between the sinks is solved numerically. The Monte Carlo method is shown to be the most accurate and efficient in the phi = 0.001-0.1 region, where a system of only 25 sinks suffices and the monopolar approximation alone is sufficiently accurate.

Beenakker, C. W. J.↗