Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Modal Analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

TU-G-303-03: Machine Learning to Improve Human Learning From Longitudinal Image Sets

‘Radiomics’ refers to studies that extract a large amount of quantitative information from medical imaging studies as a basis for characterizing a specific aspect of patient health. Radiomics models can be built to address a wide range of outcome predictions, clinical decisions, basic cancer biology, etc. For example, radiomics models can be built to predict the aggressiveness of an imaged cancer, cancer gene expression characteristics (radiogenomics), radiation therapy treatment response, etc. Technically, radiomics brings together quantitative imaging, computer vision/image processing, and machine learning. In this symposium, speakers will discuss approaches to radiomics investigations, including: longitudinal radiomics, radiomics combined with other biomarkers (‘pan-omics’), radiomics for various imaging modalities (CT, MRI, and PET), and the use of registered multi-modality imaging datasets as a basis for radiomics. There are many challenges to the eventual use of radiomics-derived methods in clinical practice, including: standardization and robustness of selected metrics, accruing the data required, building and validating the resulting models, registering longitudinal data that often involve significant patient changes, reliable automated cancer segmentation tools, etc. Despite the hurdles, results achieved so far indicate the tremendous potential of this general approach to quantifying and using data from medical images. Specific applications of radiomics to be presented in this symposium will include: the longitudinal analysis of patients with low-grade gliomas; automatic detection and assessment of patients with metastatic bone lesions; image-based monitoring of patients with growing lymph nodes; predicting radiotherapy outcomes using multi-modality radiomics; and studies relating radiomics with genomics in lung cancer and glioblastoma. Learning Objectives: Understanding the basic image features that are often used in radiomic models. Understanding requirements for reliable radiomic models, including robustness of metrics, adequate predictive accuracy, and generalizability. Understanding the methodology behind radiomic-genomic (’radiogenomics’) correlations. Research supported by NIH (US), CIHR (Canada), and NSERC (Canada)

60 APPLIED LIFE SCIENCES↗

TU-G-303-04: Radiomics and the Coming Pan-Omics Revolution

‘Radiomics’ refers to studies that extract a large amount of quantitative information from medical imaging studies as a basis for characterizing a specific aspect of patient health. Radiomics models can be built to address a wide range of outcome predictions, clinical decisions, basic cancer biology, etc. For example, radiomics models can be built to predict the aggressiveness of an imaged cancer, cancer gene expression characteristics (radiogenomics), radiation therapy treatment response, etc. Technically, radiomics brings together quantitative imaging, computer vision/image processing, and machine learning. In this symposium, speakers will discuss approaches to radiomics investigations, including: longitudinal radiomics, radiomics combined with other biomarkers (‘pan-omics’), radiomics for various imaging modalities (CT, MRI, and PET), and the use of registered multi-modality imaging datasets as a basis for radiomics. There are many challenges to the eventual use of radiomics-derived methods in clinical practice, including: standardization and robustness of selected metrics, accruing the data required, building and validating the resulting models, registering longitudinal data that often involve significant patient changes, reliable automated cancer segmentation tools, etc. Despite the hurdles, results achieved so far indicate the tremendous potential of this general approach to quantifying and using data from medical images. Specific applications of radiomics to be presented in this symposium will include: the longitudinal analysis of patients with low-grade gliomas; automatic detection and assessment of patients with metastatic bone lesions; image-based monitoring of patients with growing lymph nodes; predicting radiotherapy outcomes using multi-modality radiomics; and studies relating radiomics with genomics in lung cancer and glioblastoma. Learning Objectives: Understanding the basic image features that are often used in radiomic models. Understanding requirements for reliable radiomic models, including robustness of metrics, adequate predictive accuracy, and generalizability. Understanding the methodology behind radiomic-genomic (’radiogenomics’) correlations. Research supported by NIH (US), CIHR (Canada), and NSERC (Canada)

60 APPLIED LIFE SCIENCES↗

Micro-Spectroscopic Imaging and Characterization of Individually Identified Ice Nucleating Particles from a Case Field Study

The effect of anthropogenic and biogenic organic particles on atmospheric glaciation processes is poorly understood. We use an optical microscopy (OM) setup to identify the location of ice nuclei (IN) active in immersion freezing and deposition ice nucleation for temperatures of 200-273 K within a large population of particles sampled from an ambient environment. Applying multi-modal micro-spectroscopy methods we characterize the physicochemical properties of individual IN in particle populations collected in central California. Chemical composition and mixing state analysis of particle populations are performed to identify characteristic particle-type classes. All particle-types contained organic material. Particles in these samples take up water at subsaturated conditions, induce immersion freezing at subsaturated and saturated conditions above 226 K, and act as deposition IN below 226 K. The identified IN belong to the most common particle-type classes observed in the field samples: organic coated sea salt, Na-rich, and secondary and refractory carbonaceous particles. Based on these observations, we suggest that the IN are not always particles with unique chemical composition and exceptional ice nucleation propensity; rather, they are common particles in the ambient particle population. Thus, particle composition and morphology alone are insufficient to assess their potential to act as IN. The results suggest that particle-type abundance is also a crucial factor in determining the ice nucleation efficiency of specific IN types. These findings emphasize that ubiquitous organic particles can induce ice nucleation under atmospherically relevant conditions and that they may play an important role in atmospheric glaciation processes.

Environmental Molecular Sciences Laboratory↗

Sputter-Deposited Mo Thin Films: Multimodal Characterization of Structure, Surface Morphology, Density, Residual Stress, Electrical Resistivity, and Mechanical Response

Multimodal datasets of materials are rich sources of information which can be leveraged for expedited discovery of process–structure–property relationships and for designing materials with targeted structures and/or properties. For this data descriptor article, we provide a multimodal dataset of magnetron sputter-deposited molybdenum (Mo) thin films, which are used in a variety of industries including high temperature coatings, photovoltaics, and microelectronics. In this dataset we explored a process space consisting of 27 unique combinations of sputter power and Ar deposition pressure. Here, the phase, structure, surface morphology, and composition of the Mo thin films were characterized by x-ray diffraction, scanning electron microscopy, atomic force microscopy, and Rutherford backscattering spectrometry. Physical properties—namely, thickness, film stress and sheet resistance—were also measured to provide additional film characteristics and behaviors. Additionally, nanoindentation was utilized to obtain mechanical load-displacement data. The entire dataset consists of 2072 measurements including scalar values (e.g., film stress values), 2D linescans (e.g., x-ray diffractograms), and 3D imagery (e.g., atomic force microscopy images). An additional 1889 quantities, including film hardness, modulus, electrical resistivity, density, and surface roughness, were derived from the experimental datasets using traditional methods. Minimal analysis and discussion of the results are provided in this data descriptor article to limit the authors’ preconceived interpretations of the data. Overall, the data modalities are consistent with previous reports of refractory metal thin films, ensuring that a high-quality dataset was generated. The entirety of this data is committed to a public repository in the Materials Data Facility.

36 MATERIALS SCIENCE↗

Surface evolution of synthetic bilgewater emulsion

Bilgewater is oil-in-water emulsion emitted from shipboard and it is a source of pollution to the ocean. Wastewater treatment needs fundamental knowledge of the bilgewater surface changes; however, limited information is available. We have reported the first surface characterization of synthetic bilgewater emulsion using time-of-flight secondary ion mass spectrometry (ToF-SIMS) coupled with optical microscopy. A NAVY synthetic bilgewater emulsion consisting of three oils and a detergent mixture is used as the synthetic bilgewater model. Both fresh and aged emulsion samples are analyzed to determine their droplet size distributions (DSDs) and surface chemical compositions. Our results show that fresh emulsions are largely mono-modal with hydrocarbon fragments as the main surface composition. Aged emulsions are also monomodal with slightly larger size. Both SIMS spectral comparison and Principal Component Analysis (PCA) show that some surfactant components appear on the fresh emulsion surface immediately while larger molecular weight components appear at the aged bilge droplet surface. Our results indicate that the oil-water interface evolves after emulsion droplet forms. More importantly, surface evolution not only changes the bilgewater DSD but also surface chemical composition and reactivity.

bilgewater, droplet size distribution, ToF-SIMS, s↗

Influence of geometric and material properties on artifacts generated by interventional MRI devices: Relevance to PRF-shift thermometry

Purpose: Magnetic resonance imaging (MRI) is capable of providing valuable real-time feedback during medical procedures, partly due to the excellent soft-tissue contrast available. Several technical hurdles still exist to seamless integration of medical devices with MRI due to incompatibility of most conventional devices with this imaging modality. In this study, the effect of local perturbations in the magnetic field caused by the magnetization of medical devices was examined using finite element analysis modeling. As an example, the influence of the geometric and material characteristics of a transurethral high-intensity ultrasound applicator on temperature measurements using proton resonance frequency (PRF)-shift thermometry was investigated. Methods: The effect of local perturbations in the magnetic field, caused by the magnetization of medical device components, was examined using finite element analysis modeling. The thermometry artifact generated by a transurethral ultrasound applicator was simulated, and these results were validated against analytic models and scans of an applicator in a phantom. Several parameters were then varied to identify which most strongly impacted the level of simulated thermometry artifact, which varies as the applicator moves over the course of an ablative high-intensity ultrasound treatment. Results: Key design parameters identified as having a strong influence on the magnitude of thermometry artifact included the susceptibility of materials and their volume. The location of components was also important, particularly when positioned to maximize symmetry of the device. Finally, the location of component edges and the inclination of the device relative to the magnetic field were also found to be important factors. Conclusions: Previous design strategies to minimize thermometry artifact were validated, and novel design strategies were identified that substantially reduce PRF-shift thermometry artifacts for a variety of device orientations. These new strategies are being incorporated into the next generation of applicators. The general strategy described in this study can be applied to the design of other interventional devices intended for use with MRI.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-D-BRA-03: Analysis of Systematic Errors with 2D/3D Image Registration for Target Localization and Treatment Delivery in Stereotactic Radiosurgery

Purpose: Determine systematic deviations between 2D/3D and 3D/3D image registrations with six degrees of freedom (6DOF) for various imaging modalities and registration algorithms on the Varian Edge Linac. Methods: The 6DOF systematic errors were assessed by comparing automated 2D/3D (kV/MV vs. CT) with 3D/3D (CBCT vs. CT) image registrations from different imaging pairs, CT slice thicknesses, couch angles, similarity measures, etc., using a Rando head and a pelvic phantom. The 2D/3D image registration accuracy was evaluated at different treatment sites (intra-cranial and extra-cranial) by statistically analyzing 2D/3D pre-treatment verification against 3D/3D localization of 192 Stereotactic Radiosurgery/Stereotactic Body Radiation Therapy treatment fractions for 88 patients. Results: The systematic errors of 2D/3D image registration using kV-kV, MV-kV and MV-MV image pairs using 0.8 mm slice thickness CT images were within 0.3 mm and 0.3° for translations and rotations with a 95% confidence interval (CI). No significant difference between 2D/3D and 3D/3D image registrations (P>0.05) was observed for target localization at various CT slice thicknesses ranging from 0.8 to 3 mm. Couch angles (30, 45, 60 degree) did not impact the accuracy of 2D/3D image registration. Using pattern intensity with content image filtering was recommended for 2D/3D image registration to achieve the best accuracy. For the patient study, translational error was within 2 mm and rotational error was within 0.6 degrees in terms of 95% CI for 2D/3D image registration. For intra-cranial sites, means and std. deviations of translational errors were −0.2±0.7, 0.04±0.5, 0.1±0.4 mm for LNG, LAT, VRT directions, respectively. For extra-cranial sites, means and std. deviations of translational errors were - 0.04±1, 0.2±1, 0.1±1 mm for LNG, LAT, VRT directions, respectively. 2D/3D image registration uncertainties for intra-cranial and extra-cranial sites were comparable. Conclusion: The Varian Edge radiosurgery 6DOF-based system, can perform 2D/3D image registration with high accuracy for target localization in image-guided stereotactic radiosurgery. The work was supported by a Research Scholar Grant, RSG-15-137-01-CCE from the American Cancer Society.

60 APPLIED LIFE SCIENCES↗

Nonlinear Interface Reduction for Time-Domain Analysis of Hurty/Craig-Bampton Superelements with Frictional Contact

Virtual prototyping in engineering design relies today on modern numerical models of contacting structures with accurate resolution of interface mechanics, which strongly affect the system-level stiffness and energy dissipation due to frictional losses. High-fidelity modeling within the localized interfaces is required to resolve local quantities of interest that may drive design decisions. The high-resolution finite element meshes necessary to resolve inter-component stresses tend to be computationally expensive, particularly when the analyst is interested in response time histories. The Hurty/Craig-Bampton (HCB) transformation is a widely used method in structural dynamics for reducing the interior portion of a finite element model while having the ability to retain all nonlinear contact degrees of freedom (DOF) in physical coordinates. These models may still require many DOF to adequately resolve the kinematics of the interface, leading to inadequate reduction and computational savings. This study proposes a novel interface reduction method to overcome these challenges by means of system-level characteristic constraint (SCC) modes and properly orthogonal interface modal derivatives (POIMDs) for transient dynamic analyses. Both SCC modes and POIMDs are computed using the reduced HCB mass and stiffness matrices, which can be directly computed from many commercial finite element analysis software. Comparison of time history responses to an impulse-type load in a mechanical beam assembly indicate that the interface-reduced model correlates well with the HCB truth model. Localized features like slip and contact area are well-represented in the time domain when the beam assembly is loaded with a broadband excitation. The proposed method also yields reduced-order models with greater critical timestep lengths for explicit integration schemes.

42 ENGINEERING↗

Interim PET After Two ABVD Cycles in Early-Stage Hodgkin Lymphoma: Outcomes Following the Continuation of Chemotherapy Plus Radiotherapy

Purpose: This multicenter retrospective study was designed to evaluate the prognostic role of interim fluorodeoxyglucose-labeled positron emission tomography (i-FDG-PET) in a cohort of patients affected with early-stage Hodgkin lymphoma (HL) treated initially with adriamycin, bleomycin, vinblastine, dacarbazine (ABVD) chemotherapy followed by radiation therapy, and to assess the role of chemotherapy continuation plus radiation therapy for i-FDG-PET-positive patients. Methods and Materials: Data from 257 patients were retrieved from 4 hematology and radiation oncology departments. Inclusion criteria were stage I to IIAB HL, “intention-to-treat” AVBD plus radiation therapy, and FDG-PET at diagnosis and after the first 2 ABVD cycles. All i-FDG-PET scans underwent blinded local review by using the Deauville 5-point scoring system; patients were stratified as negative or positive using 2 Deauville score cutoff values, ≥3 or ≥4. Results: Median follow-up time was 56 months (range: 9-163 months); 5-year overall survival (OS) and disease-specific survival (DSS) for the whole cohort were 97.5% and 98.3%, respectively. Five-year progression-free survival (PFS) was 95.6%. After i-FDG-PET revision, 43 of 257 patients (16.7%) had a positive i-FDG-PET (Deauville scores: 3-5). Five-year PFS rates for i-FDG-PET-negative and i-FDG-PET-positive patients were 98.1% and 83.7%, respectively, if using a Deauville score cutoff of 3, and 97.7% and 78.6%, respectively, if using a cutoff of 4 (P=.0001). Five-year OS for i-FDG-PET-negative and i-FDG-PET-positive patients was 98.5% and 93.0%, respectively, if using a cutoff of 3, and 98.6% and 89.3%, respectively, if using a cutoff of 4 (P=.029 and P=.002). At univariate regression analysis, i-FDG-PET positivity was associated with worse OS and PFS. At multivariate analysis, performed only for PFS, i-FDG-PET positivity confirmed its negative impact (P=.002). Conclusions: i-FDG-PET is prognostic for PFS and OS in early-stage HL patients treated with combined modality therapy; the continuation of chemotherapy followed by radiation therapy is able to obtain durable, complete remission in most i-FDG-PET-positive patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Synergistic data analytics for electromechanical oscillation in electric power systems

Accurate real-time estimation of the four electromechanical oscillation properties, i.e., dominant oscillation modes, mode shapes, participation factors, and coherent groups, is of great importance to assess and mitigate potential electromechanical oscillations in interconnected power systems. While eigenvalue analysis can realize such estimation, it requires precise linearized dynamic models and accurate parameters, which are highly difficult to obtain in practice. Data fusion-based modal estimation methods can extract the properties of electromechanical oscillations from measurement data without the power system model and parameters, but most of the time only one or two property assessments can be accomplished each time. To overcome this challenge, this paper presents a synergistic data analytics solution to characterize the dynamic behaviors of electromechanical oscillations from real-time measurement data. Here, the proposed method uses optimized variable projection, and it is capable of estimating all four electromechanical oscillation behavior properties from measured responses. Case studies are performed using the simulated measurement data of a 16-generator 68-bus test system and the field measurements collected by the PMUs deployed in the Yunnan Power Grid. The results demonstrate that the proposed synergistic data analytics solution can achieve satisfactory performance in capturing the properties of electromechanical oscillations from measurement data and exhibit strong robustness against measurement noise when compared with existing measurement-based methods.

42 ENGINEERING↗

Monte Carlo-based simulation of dynamic jaws tomotherapy

Purpose: Original TomoTherapy systems may involve a trade-off between conformity and treatment speed, the user being limited to three slice widths (1.0, 2.5, and 5.0 cm). This could be overcome by allowing the jaws to define arbitrary fields, including very small slice widths (<1 cm), which are challenging for a beam model. The aim of this work was to incorporate the dynamic jaws feature into a Monte Carlo (MC) model called TomoPen, based on the MC code PENELOPE, previously validated for the original TomoTherapy system. Methods: To keep the general structure of TomoPen and its efficiency, the simulation strategy introduces several techniques: (1) weight modifiers to account for any jaw settings using only the 5 cm phase-space file; (2) a simplified MC based model called FastStatic to compute the modifiers faster than pure MC; (3) actual simulation of dynamic jaws. Weight modifiers computed with both FastStatic and pure MC were compared. Dynamic jaws simulations were compared with the convolution/superposition (C/S) of TomoTherapy in the ''cheese'' phantom for a plan with two targets longitudinally separated by a gap of 3 cm. Optimization was performed in two modes: asymmetric jaws-constant couch speed (''running start stop,'' RSS) and symmetric jaws-variable couch speed (''symmetric running start stop,'' SRSS). Measurements with EDR2 films were also performed for RSS for the formal validation of TomoPen with dynamic jaws. Results: Weight modifiers computed with FastStatic were equivalent to pure MC within statistical uncertainties (0.5% for three standard deviations). Excellent agreement was achieved between TomoPen and C/S for both asymmetric jaw opening/constant couch speed and symmetric jaw opening/variable couch speed, with deviations well within 2%/2 mm. For RSS procedure, agreement between C/S and measurements was within 2%/2 mm for 95% of the points and 3%/3 mm for 98% of the points, where dose is greater than 30% of the prescription dose (gamma analysis). Dose profiles acquired in transverse and longitudinal directions through the center of the phantom were also compared with excellent agreement (2%/2 mm) between all modalities. Conclusions: The combination of weights modifiers and interpolation allowed implementing efficiently dynamic jaws and dynamic couch features into TomoPen at a minimal cost in terms of efficiency (simulation around 8 h on a single CPU).

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Probabilistic data fusion and physics-informed machine learning: A new paradigm for modeling under uncertainty, and its application to accelerating the discovery of new materials

In this report we summarize the work conducted by PI Perdikaris and his group under this Early Career project DE–SC0019116 during the period of 09/01/2018 – 08/31/2023. The central aim of the work was to introduce a new paradigm for scientific data analysis that can seamlessly synthesize rigorous mathematical modeling with data of variable fidelity (e.g., measurements at multiple scales/resolutions or predictions of variable fidelity models) and multiple modalities (e.g., images, time–series, or scattered measurements). The setting we are interested in involves complex systems that are partially observed and whose dynamical behavior could be hard to model or totally unknown. The inherent uncertainty associated with this setting necessitates a departure from the classical deterministic realm of modeling and scientific computation, and, consequently, our main building blocks can no longer be crisp deterministic numbers and governing laws, but instead we must operate with probabilistic models.

97 MATHEMATICS AND COMPUTING↗

A Dynamic Hierarchical Attention Framework for Multimodal Malware Detection

The increasing use of Android in the worldwide mobile ecosystem has come along with a significant increase in advanced malware, highlighting the critical necessity for efficient, scalable, and adaptable detection systems. Despite recent advancements in machine learning improving malware detection, the majority of current solutions are limited to one, two, or three data modalities, hence neglecting the comprehensive behavioral spectrum of contemporary multi-vector threats. This thesis presents the first comprehensive multimodal framework for Android malware detection, which combines textual, time-series (temporal), graph-based (structural), and visual information using an innovative hierarchical attention mechanism and Dynamic Fusion Controller (DFC). Our methodology consistently classifies and processes modalities as either sequential or structural, facilitating content-adaptive weighting and resilient cross-modal representation learning. We advance the implementation of cutting-edge time series techniques, such as MiniRocket, for malware detection, hence creating new opportunities for temporal analysis in cybersecurity. Comprehensive experimental assessment shows that our framework performs exceptionally well, with 99.46% classification accuracy and 97.15% detection accuracy, significantly outperforming existing approaches through effective multimodal integration and hierarchical attention mechanisms.

Nazmin, Tamanna↗

Spectro-Microscopic Analysis of Soot Particle Composition and Source Attribution

Ambient soot particles significantly impact Earth’s radiative balance, human health, and atmospheric visibility. Their microstructural properties depend on formation and aging mechanisms, which vary by emission source and atmospheric processes. Hence, accurately identifying sources of soot enhances our understanding of their physicochemical properties and atmospheric implications. This study used a multi-modal approach to characterize and attribute sources of submicron soot particles collected in Israel during new particle formation events, biomass burning episodes, and background atmospheric conditions. Synchrotron-based X-ray microscopy was used to map soot (elemental carbon), organic carbon, and inorganic species. Implemented atomic force microscopy showed highly diverse phase states, with soot consistently exhibiting a solid-like phase. Automated µ-Raman analysis was subsequently performed on ~690 particles, identifying three soot classes based on spectral features corresponding to the "Defect" (D) and "Graphite" (G) bands of soot. We applied two-peak and five-peak fitting approaches to deconvolute the “Defect” peaks (D1, D2, D3, and D4) and G band from average Raman, revealing varying degrees of graphitic order. The degree of graphitic order was determined from metrics such as the D3 peak area, often observed when soot was internally mixed with organic material. Raman spectral features, along with temporal variations in particle classes contributions, suggest that Particle Type 1 corresponds to traffic related soot and Particle Type 2 to less graphitic soot from biomass burning, while Particle Type 3 is associated with more heterogeneous particulate representative of soot-OC mixtures emitted during new particle formation and biomass burning episodes.

Rivera-Adorno, Felipe (ORCID:0000000273557999)↗

A guided wave sensor enabling simultaneous wavenumber-frequency analysis for both lamb and shear-horizontal waves

Guided waves in plate-like structures have been widely investigated for structural health monitoring. Lamb waves and shear horizontal (SH) waves, two commonly used types of waves in plates, provide different benefits for the detection of various types of defects and material degradation. However, there are few sensors that can detect both Lamb and SH waves and also resolve their modal content, namely the wavenumber-frequency spectrum. A sensor that can detect both waves is desirable to take full advantage of both types of waves in order to improve sensitivity to different discontinuity geometries. As a result, we demonstrate that polyvinylidene difluoride (PVDF) film provides the basis for a multi-element array sensor that detects both Lamb and SH waves and also measures their modal content, i.e., the wavenumber-frequency spectrum.

36 MATERIALS SCIENCE↗

A Prospective Comparison of the Effects of Interfractional Variations on Proton Therapy and Intensity Modulated Radiation Therapy for Prostate Cancer

Purpose: To quantify and compare the impact of interfractional setup and anatomic variations on proton therapy (PT) and intensity modulated radiation therapy (IMRT) for prostate cancer. Methods and Materials: Twenty patients with low-risk or intermediate-risk prostate cancer randomized to receive passive-scattering PT (n=10) and IMRT (n=10) were selected. For both modalities, clinical treatment plans included 50.4 Gy(RBE) to prostate and proximal seminal vesicles, and prostate-only boost to 79.2 Gy(RBE) in 1.8 Gy(RBE) per fraction. Implanted fiducials were used for prostate localization and endorectal balloons were used for immobilization. Patients in PT and IMRT arms received weekly computed tomography (CT) and cone beam CT (CBCT) scans, respectively. The planned dose was recalculated on each weekly image, scaled, and mapped onto the planning CT using deformable registration. The resulting accumulated dose distribution over the entire treatment course was compared with the planned dose using dose-volume histogram (DVH) and γ analysis. Results: The target conformity index remained acceptable after accumulation. The largest decrease in the average prostate D{sub 98} was 2.2 and 0.7 Gy for PT and IMRT, respectively. On average, the mean dose to bladder increased by 3.26 ± 7.51 Gy and 1.97 ± 6.84 Gy for PT and IMRT, respectively. These values were 0.74 ± 2.37 and 0.56 ± 1.90 for rectum. Differences between changes in DVH indices were not statistically significant between modalities. All volume indices remained within the protocol tolerances after accumulation. The average pass rate for the γ analysis, assuming tolerances of 3 mm and 3%, for clinical target volume, bladder, rectum, and whole patient for PT/IMRT were 100/100, 92.6/99, 99.2/100, and 97.2/99.4, respectively. Conclusion: The differences in target coverage and organs at risk dose deviations for PT and IMRT were not statistically significant under the guidelines of this protocol.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Early Significant Tumor Volume Reduction After Radiosurgery in Brain Metastases From Renal Cell Carcinoma Results in Long-Term Survival

Purpose: To retrospectively evaluate survival of patients with brain metastasis from renal cell carcinoma (RCC) after radiosurgery. Patients and Methods: Between 1998 and 2010, 46 patients were treated with radiosurgery, and the total number of lesions was 99. The mean age was 58.9 years (range, 33-78 years). Twenty-six patients (56.5%) had a single brain metastasis. The mean tumor volume was 3.0 cm{sup 3} (range, 0.01-35.1 cm{sup 3}), and the mean marginal dose prescribed was 20.8 Gy (range, 12-25 Gy) at the 50% isodose line. A patient was classified into the good-response group when the sum of the volume of the brain metastases decreased to less than 75% of the original volume at a 1-month follow-up evaluation using MRI. Results: As of December 28, 2010, 39 patients (84.8%) had died, and 7 (15.2%) survived. The overall median survival time was 10.0 {+-} 0.4 months (95% confidence interval, 9.1-10.8). After treatment, local tumor control was achieved in 72 (84.7%) of the 85 tumors assessed using MRI after radiosurgery. The good-response group survived significantly longer than the poor-response group (median survival times of 18.0 and 9.0 months, respectively; p = 0.025). In a multivariate analysis, classification in the good-response group was the only independent prognostic factor for longer survival (p = 0.037; hazard ratio = 0.447; 95% confidence interval, 0.209-0.953). Conclusions: Radiosurgery seems to be an effective treatment modality for patients with brain metastases from RCC. The early significant tumor volume reduction observed after radiosurgery seems to result in long-term survival in RCC patients with brain metastases.

62 RADIOLOGY AND NUCLEAR MEDICINE↗